首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The application of functionally graded material (FGM) concept to piezoelectric transducers allows the design of composite transducers without interfaces, due to the continuous change of property values. Thus, large improvements can be achieved, as reduction of stress concentration, increasing of bonding strength, and bandwidth. This work proposes to design and to model FGM piezoelectric transducers and to compare their performance with non-FGM ones. Analytical and finite element (FE) modeling of FGM piezoelectric transducers radiating a plane pressure wave in fluid medium are developed and their results are compared. The ANSYS software is used for the FE modeling. The analytical model is based on FGM-equivalent acoustic transmission-line model, which is implemented using MATLAB software. Two cases are considered: (i) the transducer emits a pressure wave in water and it is composed of a graded piezoceramic disk, and backing and matching layers made of homogeneous materials; (ii) the transducer has no backing and matching layer; in this case, no external load is simulated. Time and frequency pressure responses are obtained through a transient analysis. The material properties are graded along thickness direction. Linear and exponential gradation functions are implemented to illustrate the influence of gradation on the transducer pressure response, electrical impedance, and resonance frequencies.  相似文献   

2.
Evans MJ  Webster JR  Cawley P 《Ultrasonics》2000,37(8):589-594
The use of conical piezoelectric transducers as point acoustic sources has been investigated. It has been shown that transducers based on a design originally developed at the National Institute for Standards and Technology in the USA can be used as point transmitters over the frequency range of interest in acoustic emission measurements (100 kHz to around 1 MHz). They should, therefore, be suitable for use in experiments to calibrate structures so that acoustic emission source strengths can be determined. It has also been shown that measurements of the response of the transmitting transducer backing can be used to assess the coupling efficiency, and hence to remove concerns about inconsistent coupling affecting the calibration measurements. The results indicate that the variation of the backing response with coupling is due to a shift in the resonance frequencies of the transducer with the mechanical load impedance. If other transducers can be shown to behave in a similar fashion this effect could be used to measure coupling in standard acoustic emission and ultrasonic transducers.  相似文献   

3.
厚度模压电超声换能器作为超声波发射、接收以及电信号间转换的载体,是超声成像与检测系统的核心器件,一般由压电层、匹配层和背衬层3部分组成。超声换能器的性能一定程度上决定着整体超声设备的性能,影响了其在工业、医学、军事等领域的应用。该换能器的关键性能指标(带宽、灵敏度)除了受到压电层的影响,还与匹配层、背衬层等无源声学材料的设计密切相关。该文综述了近年来厚度模压电超声换能器无源声学材料(匹配层、背衬层和声透镜)的研究进展,提出了当前该类材料面临的难题和解决途径,并对其未来发展方向进行了展望。  相似文献   

4.
超声可用于测量一些非声学特性。在这些应用中,需要准确测量超声波的渡越时间。为此,不应漏测接收信号到达时的前一两个波,这要求首波的幅度等于或大于次波的幅度。本文分析了发射和接收换能器的瞬态特性,包括双探头的和单探头的,从而证明,如果增加换能器背衬的声阻率,首次波幅度比可以从小于1加大到1或大于1。这是对轻负载讲的。如果负载相当重,首次波幅度比自动地比较大。 关键词:  相似文献   

5.
A general equation is derived that describes the behavior of a piezoelectric transducer with a nonuniform distribution of piezoelectric coefficient within its bulk, when submitted to an arbitrary distribution of acoustic pressure. Based on this equation, an expression for the receiving transfer function of the transducer is calculated. The results demonstrate the dependence of the transfer function on the distribution of piezoelectric coefficient, and that it is possible to benefit from a nonuniform distribution to optimize the transfer function. The general equation also describes the influence of the external electric circuit loading the transducer, which leads to another independent means of optimizing the transfer function. The proposed model combines effects of piezoelectric material characteristics, acoustic backing, and electric loading, without resorting to Mason or other equivalent circuits for the transducer.  相似文献   

6.
A novel method for the measurement of acoustic speed   总被引:1,自引:0,他引:1  
Traditional methods for measuring acoustic speed require knowledge of either the specimen thickness or the distances between the transducers and the specimen. In general, the accuracy in measuring these quantities determines the accuracy of the experimental technique for measuring speed. This problem is particularly acute in measuring sound speed in biological specimens. A new method for measuring acoustic speed of materials, which eliminates the need for determining these quantities, has been developed. The technique, which necessitates the use of only one transducer, requires measurement of four times of flight of a sound pulse and the knowledge of the speed of sound in a reference fluid medium in which the specimen is placed. Ultrasonic speed in stainless steel and Plexiglas was measured using this method to verify its validity. Results on measurements on porcine liver, myocardium, and soft fat are also reported.  相似文献   

7.
An analytical technique previously developed to study tissue displacement due to acoustic radiation force is extended to analyze temperature rise in tissue for exposure times that are comparable to, or longer than, the tissue perfusion time. A focused transducer with Gaussian amplitude shading is assumed to radiate into a perfused tissue medium with constant thermal and acoustic properties. A simple closed-form expression is derived for the steady-state temperature rise, and a transient correction term is constructed that allows for computation of the equilibrium time of the medium. Comparisons with temperature calculations for non-Gaussian transducers show that the model may be applied to more general intensity profiles.  相似文献   

8.
Acoustic impedance matching of medical ultrasound transducers   总被引:1,自引:0,他引:1  
Ultrasonic transducers for pulse-echo systems are studied both theoretically and experimentally. For the theoretical calculations the Mason model for thickness-mode disc transducers with and without backing and matching layers is used. By building several of the theoretically investigated transducer configurations it is shown that theory and experiment agree well. Thus the properties of a transducer can be predicted to a good approximation before its experimental realization. To find transducers with good sensitivity and short pulses, the pulse shape and frequency response for the following classes of transducers were studied both theoretically and experimentally: transducers with backing only, transducers with heavy backing and front matching layers, and air-backed transducers with front matching layers.  相似文献   

9.
匹配层和背衬层是换能器的重要组成部分,对换能器特性有重要影响。针对发射型换能器,基于有/无匹配层和空气/树脂背衬两种条件组合,该文研究了匹配层与背衬层对换能器辐射特性的影响。结果表明,负载材料为水时,空气背衬换能器相较于树脂背衬换能器声能辐射效率更高;匹配层可以提高换能器的主瓣能量,抑制旁瓣能量及旁瓣数量。因此,针对发射型换能器的设计,背衬材料的选择应遵循与压电材料的阻抗差异越大越优的原则;匹配层的合理设计不仅可以提高超声换能器的声能辐射效率,还可以提高主瓣旁瓣峰值比,使声能更集中。  相似文献   

10.
Transducers for acoustic beacons which can produce outgoing signals with wave fronts whose horizontal cross sections are circular or spiral are studied experimentally. A remote hydrophone is used to determine its aspect relative to the transducers by comparing the phase of the circular signal to the phase of the spiral signal. The transducers for a "physical-spiral" beacon are made by forming a strip of 1-3 piezocomposite transducer material around either a circular or spiral backing. A "phased-spiral" beacon is made from an array of transducer elements which can be driven either in phase or staggered out of phase so as to produce signals with either a circular or spiral wave front. Measurements are made to study outgoing signals and their usefulness in determining aspect angle. Vertical beam width is also examined and phase corrections applied when the hydrophone is out of the horizontal plane of the beacon. While numerical simulations indicate that the discontinuity in the physical-spiral beacon introduces errors into the measured phase, damping observed at the ends of the piezocomposite material is a more significant source of error. This damping is also reflected in laser Doppler vibrometer measurements of the transducer's surface velocity.  相似文献   

11.
This paper describes fabrication and comparison of PMN-PT single crystal, PZT, and PZT-based 1-3 composite ultrasonic transducers for NDE applications. As a front matching layer between test material (Austenite stainless steel, SUS316) and piezoelectric materials, alumina ceramics was selected. The appropriate acoustic impedance of the backing materials for each transducer was determined based on the results of KLM model simulation. Prototype ultrasonic transducers with the center frequencies of approximately 2.25 and 5 MHz for contact measurement were fabricated and compared to each other. The PMN-PT single crystal ultrasonic transducer shows considerably improved performance in sensitivity over the PZT and PZT-based 1-3 composite ultrasonic transducers.  相似文献   

12.
For non-destructive testing applications it is often necessary to limit the number of cycles in a pulse produced by ultrasonic transducers. Usually a backing with a high ultrasonic attenuation and with an acoustic impedance chosen to match that of the piezoelectric active element of the transducer is employed. The acoustic properties of the commonly used tungsten/Araldite backings are compared theoretically with those of composites made by pressing tungsten powder with a powder of a plastic metal. The change in ultrasonic velocity and attenuation due to scattering by the tungsten particles is investigated and the dependence on frequency is determined.  相似文献   

13.
This paper describes the application of an acousto-optic method to the measurement of airborne ultrasound. The method consists of a heterodyne interferometric probing of the pressure emitted by the transducer combined with a tomographic algorithm. The heterodyne interferometer measures the optical phase shift of the probe laser beam, proportional to the acoustic pressure integrated along the light path. A number of projections of the sound field, e.g. a set of ray integrals obtained along parallel paths, are made in moving the transducer to be tested. The main advantage of the method is its very high sensitivity in air (2 x 10(-4) Pa Hz-1/2), combined with a large bandwidth. Using the same principle as X-ray tomography the ultrasonic pressure in a plane perpendicular to the transducer axis can be reconstructed. Several ultrasonic fields emitted by wide-band home made electrostatic transducers, with operating frequencies between 200 and 700 kHz, have been measured. The sensitivities compared favorably with those of commercial airborne transducers.  相似文献   

14.
Hollow piezoelectric cylindrical shell transducers may be made directional for underwater acoustic applications by the use of suitable acoustical baffles and the operational bandwidth may be extended by using multiple resonant modes. A theoretical and experimental investigation was performed for circumferentially baffled piezoelectric cylindrical shell transducers operating in the zero and one modes of extensional vibration. The frequency responses and directivity patterns were analyzed under various conditions of energizing separate halves of electrodes. It was found that the broadest frequency response with nearly constant beamwidth can be obtained when the two halves of the piezoelectric ring are electromechanically excited 90 deg out-of-phase. The experimental results obtained with a proof-of-concept transducer were in good agreement with the theoretical predictions.  相似文献   

15.
Zhou QF  Cannata J  Kirk Shung K 《Ultrasonics》2006,44(Z1):e607-e611
Using inversion domain engineering controlled by heating temperature, the LiNbO(3) (LNO) piezoelectric plate with both odd and even-order thickness-extensional modes can be excited simultaneously. Therefore, the inversion layer ultrasound transducer is expected to be capable of operating over a wider frequency range. In this paper, the electrical impedance and the acoustic characteristics of LiNbO(3) (LNO) inversion layer transducer have been studied by finite element modeling (FEM). The transducer designed for this study uses a 36 degrees rotated Y-cut LiNbO(3) thin plate with an active element thickness of approximately 100 microm. First the electrical and elastic properties of the 36 degrees rotated Y-cut LNO were obtained by transforming a basic piezoelectric matrix for Z-cut LNO. In order to validate the FEM using the transformed properties several pieces of pure and 50% inversion layer LNO were tested on the electrical impedance analyzer. The modeled impedance characteristics were consistent with the measured data. Next the model was used to design 50-60 MHz transducers using pure and 30% inversion LNO. Two lambda/4 matching layers and a Tungsten loaded epoxy backing were used in these designs. The modeled results show that an over 90% bandwidth transducer can be made with proper matching and 30% inversion layer.  相似文献   

16.
Conventional ultrasound transducers used for medical diagnosis generally consist of linearly aligned rectangular apertures with elements that are focused in one plane. While traditional beamforming is easily accomplished with such transducers, the development of quantitative, physics-based imaging methods, such as tomography, requires an accurate, and computationally efficient, model of the field radiated by the transducer. The field can be expressed in terms of the Helmholtz-Kirchhoff integral; however, its direct numerical evaluation is a computationally intensive task. Here, a fast semianalytical method based on Stepanishen's spatial impulse response formulation [J. Acoust. Soc. Am. 49, 1627-1638 (1971)] is developed to compute the acoustic field of a rectangular element of cylindrically concave transducers in a homogeneous medium. The pressure field, for, lossless and attenuating media, is expressed as a superposition of Bessel functions, which can be evaluated rapidly. In particular, the coefficients of the Bessel series are frequency independent and need only be evaluated once for a given transducer. A speed up of two orders of magnitude is obtained compared to an optimized direct numerical integration. The numerical results are compared with Field II and the Fresnel approximation.  相似文献   

17.
This paper investigates the use of micro-stereolithography, a rapid prototyping technique, in the manufacture of transducers. It is illustrated for the production of electromagnetic acoustic transducer (EMATs) coils in both meander-line and spiral configurations. A synthetic aperture focussing technique (SAFT) has been applied to the ultrasonic signals from these devices to reconstruct images in metallic objects.  相似文献   

18.
超声检测用压电换能器瞬态特性可控可调   总被引:2,自引:0,他引:2       下载免费PDF全文
李明轩 《应用声学》2008,27(5):338-344
超声检测用压电换能器瞬态特性主要包括瞬态空间响应和瞬态时间响应。本文通过调整控制换能器和激励源,实现瞬态空间响应和瞬态时间响应的某些特性的可控可调。其中包括在空间响应方面消除边缘波以获得平行声束和消除平面波以获得聚焦绳声束;在时间响应方面,调整换能器的背衬阻抗以获得可调首次波幅比和调整换能器结构和激励电信号以获得任意检测信号等。  相似文献   

19.
Lee YC  Lin Z 《Ultrasonics》2006,44(Z1):e693-e697
This paper reports a new type miniature-conical transducer for acoustic emission measurements. The transducer follows the basic idea and structure of a conventional NBS conical transducer, but is much compact in size and easier to use. The improvements are made possible by introducing an excimer laser micromachining method for fabricating smaller PZT conical elements, which play a key role in the transducer. Conical PZT elements with contact size less then 300 microm are laser-machined and the miniature-conical transducers are constructed. Standard quantitative acoustic emission testing is performed on a plate using the fabricated transducers and good results are observed. The transducers can be very useful in many applications involving quantitative measurements of transient elastic waves.  相似文献   

20.
Ultrasonic transducers made with 1-3 connectivity piezocomposites are frequently used in Medical applications and nondestructive testing. When the transducer is used for special applications as, for instance air-coupled transmission, it is necessary to compensate for the high difference of acoustic impedance between transducer and medium using high amplitude pulses to generate high acoustic signal. Thus, the nonlinear behavior of the transducer must be taken into account in similar application conditions. The newly developed method, which performs the nonlinear characterization with burst signal excitation near the thickness resonance frequency, is based on the measure of the current as well as the vibration velocity of the piezocomposite transducer. The current of the stationary response is measured before the end of the burst signal excitation. Burst excitation enables us to measure the nonlinear characterization without producing overheating in the transducers. The amplitude level dependence of mechanical losses tandelta(m) and the stiffness increases |Deltac/c(0)| have been studied, as well as the velocity dependence of a point of the transducer, measured with a laser vibrometer. In this method, the power level applied to the transducers can be higher than other nonlinear measurement methods, providing measurements of high accuracy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏