1.
Liu S 《Electrophoresis》2003,24(21):3755-3761
We have created a hybrid device of a microfabricated round-channel twin-T injector incorporated with a separation capillary in order to extend the straight separation distance for high speed and long readlength DNA sequencing. Semicircular grooves on glass wafers are obtained using a photomask with a narrow line-width and a standard isotropic photolithographic etching process. Round channels are made when two etched wafers are face-to-face aligned and bonded. A two-mask fabrication process has been developed to make channels of two different diameters. The twin-T injector is formed by the smaller channels whose diameter matches the bore of the separation capillary, and the "usual" separation channel, now called the connection channel, is formed by the larger ones whose diameter matches the outer diameter of the separation capillary. The separation capillary is inserted through the connection channel all the way to the twin-T injector to allow the capillary bore flush with the twin-T injector channels. The total dead-volume of the connection is estimated to be approximately 5 pL. To demonstrate the efficiency of this hybrid device, we have performed four-color DNA sequencing on it. Using a 200 microm twin-T injector coupled with a separation capillary of 20 cm effective separation distance, we have obtained readlengths of 800 plus bases at an accuracy of 98.5% in 56 min, compared to about 650 bases in 100 min on a conventional 40 cm long capillary sequencing machine under similar conditions. At an increased separation field strength and using a diluted sieving matrix, the separation time has been reduced to 20 min with a readlength of 700 bases at 98.5% base-calling accuracy.  相似文献   

2.
We demonstrate a versatile microfabricated electrophoresis platform, incorporating arrays of integrated on-chip electrodes, heaters, and temperature sensors. This design allows a range of different sieving gels to be used within the same device to perform separations involving both single- and double-stranded DNA over distances on the order of 1 cm. We use this device to compare linear and cross-linked polyacrylamide, agarose, and thermo-reversible Pluronic-F127 gels on the basis of gel casting ease, reusability, and overall separation performance using a 100 base pair double-stranded DNA ladder as a standard sample. While cross-linked polyacrylamide matrices provide consistently high-quality separations in our system over a wide range of DNA fragment sizes, Pluronic gels also offer compelling advantages in terms of the ability to remove and reload the gel. Agarose gels offer good separation performance, however, additional care must be exercised to ensure consistent gel properties as a consequence of the need for elevated gel loading temperatures. We also demonstrate the use of denaturing cross-linked polyacrylamide gels at concentrations up to 19% to separate single-stranded DNA fragments ranging in size from 18 to 400 bases in length. Primers differing by 4 bases at a read length of 30 bases can be separated with a resolution of 0.9-1.0 in under 20 min. This level of performance is sufficient to conduct a variety of genotyping assays including the rapid detection of single nucleotide polymorphisms (SNPs) in a microfabricated platform. The ability to use a single microelectrophoresis system to satisfy a wide range of separation applications offers molecular biologists an unprecedented level of flexibility in a portable and inexpensive format.  相似文献   

3.
Miniaturization of separation columns implies equally reduced vol- umes of injectors, detectors, and the connecting channels. Planar chip technology provides a powerful means for the fabrication of micron-sized structures such as channels. This is demonstrated by two examples. An optical absorbance detector chip exhibits the expected behavior of a 1 mm optical path length cell despite its volume of 1 nL. A capillary electrophoresis device allows integrated injections of 100 pL samples, efficiencies of 70,000 to 160,000 theoretical plates in 10 to 20 seconds, and external laser-induced fluorescence detection at any capillary length of choice between 5 and 50 mm.  相似文献   

4.
Miniaturization of separation columns implies equally reduced volumes of injectors, detectors and the connecting channels. Planar chip technology provides a powerful means for the fabrication of micron sized structures such as channels. This is demonstrated with three examples. An optical absorbance detector chip exhibits the expected behavior of a 1 mm optical pathlength cell despite its volume of 4 nL. A capillary electrophoresis device allows for integrated injections of 100 pL samples, for efficiencies of 70 000 to 160 000 theoretical plates in 10 to 20 seconds, and for external laser-induced fluorescence detection at any capillary length of choice between 5 and 50 mm. A system for synchronized cyclic capillary electrophoresis is also presented in which plate numbers per volt can be dramatically increased.  相似文献   

5.
Polyimide HPLC‐Chip devices containing poly(methylstyrene‐bis‐p‐vinylphenyl)ethane (MS/BVPE) stationary phase within the device channels and with wall attachment were prepared by thermally initiated free radical polymerization. The microfluidic devices were coupled to both UV and MS detectors. The potential of the MS/BVPE monolith as an alternative separation media within chip devices was investigated by side‐by‐side comparisons to particulate media within commercial devices. The chromatographic behavior of this stationary phase was comparable to particulate media for separations of proteins as the average peak width at half‐height was equal (6.2 s) for a separation within 8 min under gradient elution conditions. The ability to control the porosity characteristics of the MS/BVPE monolith with changes in polymerization time also extended its utility into small analyte (< 500 Da) applications, although more optimization is needed to match conventional RP media for these applications. The good mechanical stability of the MS/BVPE monolith within the microdevices enabled excellent run‐to‐run repeatability (%RSD retention time (? 0.16) and chip‐to‐chip reproducibility (%RSD retention time (1.4). The use of this material within enrichment channels also shows its potential value in more complex work flows.  相似文献   

6.
We report the development of a microfabricated gas chromatography system suitable for the separation of volatile organic compounds (VOCs) and compatible with use as a portable measurement device. Hydrofluoric acid etching of 95 × 95 mm Schott B270 wafers has been used to give symmetrical hemi-spherical channels within a glass substrate. Two matching glass plates were subsequently cold bonded with the channels aligned; the flatness of the glass surfaces resulted in strong bonding through van der Waals forces. The device comprised gas fluidic interconnections, injection zone and 7.5 and 1.4 m long, 320 μm internal diameter capillaries. Optical microscopy confirmed the capillaries to have fully circular channel profiles. Direct column heating and cooling could be achieved using a combination of resistive heaters and Peltier devices. The low thermal conductivity of glass allowed for multiple uniform temperature zones to be achieved within a single glass chip. Temperature control over the range 10–200 °C was achieved with peak power demand of approximately 25 W. The 7.5 m capillary column was static coated with a 2 μm film of non-polar dimethylpolysiloxane stationary phase. A standard FID and a modified lightweight 100 mW photoionization detector (PID) were coupled to the column and performance tested with gas mixtures of monoaromatic and monoterpene species at the parts per million concentration level. The low power GC-PID device showed good performance for a small set of VOCs and sub ng detection sensitivity to monoaromatics.  相似文献   

7.
Takeda M  Shiku H  Ino K  Matsue T 《The Analyst》2011,136(23):4991-4996
An electrochemical platform for parallel monitoring of secreted alkaline phosphatase (SEAP) has been microfabricated on a device with a mammalian-cell array chip. A 4 × 4 ring-ring electrode array was designed at the rim of the round cellular pattern with a diameter of 270 μm. Electrochemical characterization was carried out, and it was found that the collection efficiency was about 50% in dual mode when the inner-ring and the outer-ring electrodes were selected as the collector and generator electrodes, respectively. The current amplification ratio for the dual mode normal to single mode was 2.84. SEAP expressing from the cells was parallelly monitored by using a multiplexer switching system at the 16 round cellular spots. The reduction current for HeLa cells transfected with plasmid encoding SEAP observed at the collector outer ring electrode was found to be significantly higher than that for wild-type HeLa. Finally, the top of the microwell with the round cellular pattern was covered with a poly(dimethylsiloxane) block for 5 min to accumulate the secreted enzyme and the product of the enzyme reaction so that further signal enhancement could be observed.  相似文献   

8.
Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis   总被引:2,自引:0,他引:2  
A fully integrated genomic analysis microsystem including microfabricated heaters, temperature sensors, and PCR chambers directly connected to capillary electrophoretic separation channels has been constructed. Valves and hydrophobic vents provide controlled and sensorless sample positioning and immobilization into 200 nL PCR chambers. The use of microfabricated heating and temperature sensing elements improves the heating and cooling rates for the PCR reaction to 20 degree C s(-1). The amplified PCR product, labeled on-column with an intercalating fluorescent dye, is injected into the gel-filled capillary for electrophoretic analysis. Successful sex determination using a multiplex PCR reaction from human genomic DNA is demonstrated in less than 15 min. This device is an important step toward a microfabricated genomic microprocessor for use in forensics and point-of-care molecular medical diagnostics.  相似文献   

9.
Li Z  Sun K  Sunayama M  Araki R  Ueno K  Abe M  Misawa H 《Electrophoresis》2011,32(23):3392-3398
Fraction collection of selected components from a complex mixture plays a critical role in biomedical research, environmental analysis, and biotechnology. Here, we introduce a novel electrophoretic chip device based on a signal processing theorem that allows simultaneous space sampling for fractionation of ssDNA target fragments. Ten parallel extraction channels, which covered 1.5-mm-long sampling ranges, were used to facilitate the capturing of fast-moving fragments. Furthermore, the space sampling extraction made it possible to acquire pure collection, even from partly overlapping fragments that had been insufficiently separated after a short electrophoretic run. Fragments of 180, 181, and 182 bases were simultaneously collected, and then the recovered DNA was PCR amplified and assessed by CE analysis. The 181-base target was shown to be isolated in a 70-mm-long separation length within 10 min, in contrast to the >50 min required for the 300-mm-long separation channel in our previous study. This method provides effective combination of time and space, which is a breakthrough in the traditional concept of fraction collection on a chip.  相似文献   

10.
Copolymers of acrylamide (AM) and N,N-dimethylacrylamide (DMA) with AM to DMA molar ratios of 3:1, 2:1 and 1:1 and molecular weights of about 2.2 MDa were synthesized. The polymers were tested as separation media in DNA sequencing analysis by capillary electrophoresis (CE). The dynamic coating ability of polydimethylacrylamide (PDMA) and the hydrophilicity of polyacrylamide (PAM) have been successfully combined in these random copolymers. A separation efficiency of over 10 million theoretical plates per meter has been reached by using the bare capillaries without the additional polymer coating step. Under optimized separation conditions for longer read length DNA sequencing, the separation ability of the copolymers decreased with decreasing AM to DMA molar ratio from 3:1, 2:1 and 1:1. In comparison with PAM, the copolymer with a 3:1 AM:DMA ratio showed a higher separation efficiency. By using a 2.5% w/v copolymer with 3:1 AM:DMA ratio, one base resolution of 0.55 up to 699 bases and 0.30 up to 963 bases have been achieved in about 80 min at ambient temperatures.  相似文献   

11.
Microfluidic device for capillary electrochromatography-mass spectrometry   总被引:2,自引:0,他引:2  
Lazar IM  Li L  Yang Y  Karger BL 《Electrophoresis》2003,24(21):3655-3662
A novel microfabricated device that integrates a monolithic polymeric separation channel, an injector, and an interface for electrospray ionization-mass spectrometry detection (ESI-MS) was devised. Microfluidic propulsion was accomplished using electrically driven fluid flows. The methacrylate-based monolithic separation medium was prepared by photopolymerization and had a positively derivatized surface to ensure electroosmotic flow (EOF) generation for separation of analytes in a capillary electrochromatography (CEC) format. The injector operation was optimized to perform under conditions of nonuniform EOF within the microfluidic channels. The ESI interface allowed hours of stable operation at the flow rates generated by the monolithic column. The dimensions of one processing line were sufficiently small to enable the integration of 4-8 channel multiplexed structures on a single substrate. Standard protein digests were utilized to evaluate the performance of this microfluidic chip. Low- or sub-fmol amounts were injected and detected with this arrangement.  相似文献   

12.
In this paper we present the development of a DNA analysis system using a microfabricated channel device and a novel transmission imaging spectrograph which can be efficiently incorporated into a high throughput genomics facility for both sizing and sequencing of DNA fragments. The device contains 48 channels etched on a glass substrate. The channels are sealed with a flat glass plate which also provides a series of apertures for sample loading and contact with buffer reservoirs. Samples can be easily loaded in volumes up to 640 nL without band broadening because of an efficient electrokinetic stacking at the electrophoresis channel entrance. The system uses a dual laser excitation source and a highly sensitive charge-coupled device (CCD) detector allowing for simultaneous detection of many fluorescent dyes. The sieving matrices for the separation of single-stranded DNA fragments are polymerized in situ in denaturing buffer systems. Examples of separation of single-stranded DNA fragments up to 500 bases in length are shown, including accurate sizing of GeneCalling fragments, and sequencing samples prepared with a reduced amount of dye terminators. An increase in sample throughput has been achieved by color multiplexing.  相似文献   

13.
Parallel analysis of biomolecules on a microfabricated capillary array chip   总被引:2,自引:0,他引:2  
Shen Z  Liu X  Long Z  Liu D  Ye N  Qin J  Dai Z  Lin B 《Electrophoresis》2006,27(5-6):1084-1092
This paper focused on a self-developed microfluidic array system with microfabricated capillary array electrophoresis (mu-CAE) chip for parallel chip electrophoresis of biomolecules. The microfluidic array layout consists of two common reservoirs coupled to four separation channels connected to sample injection channel on the soda-lime glass substrate. The excitation scheme for distributing a 20 mW laser beam to separation channels in an array is achieved. Under the control of program, the sample injection and separation in multichannel can be achieved through six high-voltage modules' output. A CCD camera was used to monitor electrophoretic separations simultaneously in four channels with LIF detection, and the electropherograms can be plotted directly without reconstruction by additional software. Parallel multichannel electrophoresis of series biomolecules including amino acids, proteins, and nucleic acids was performed on this system and the results showed fine reproducibility.  相似文献   

14.
Chiral separations of fluorescamine-labeled amino acids are characterized and optimized on a microfabricated capillary electrophoresis (CE) device. A standard mixture of acidic and neutral amino acids is labeled with fluorescamine in less than 5 min and the hydroxypropyl-beta-cyclodextrin (HPbetaCD) concentration, temperature, and pH are optimized (15 mM HPbetaCD, 6 degrees C, pH < 9) to achieve high-quality and low background chiral separations in less than 200 s. All four stereoisomers formed in the labeling reaction of the chiral dye with the chiral amino acids are typically resolved. At pH > 9, isomerization of the dye chiral center is observed that occurs on the time scale of the chip separation. Typical limits of detection are approximately 50 nM. These results demonstrate the feasibility of combining fluorescamine labeling of amino acids with microfabricated CE devices to develop low-volume, high-sensitivity apparatus and methods for extraterrestrial exploration.  相似文献   

15.
Ueda M  Kiba Y  Abe H  Arai A  Nakanishi H  Baba Y 《Electrophoresis》2000,21(1):176-180
A laser-induced fluorescence detection system coupled with a highly sensitive silicon-intensified target (SIT) camera is successfully applied to the imaging of a band for DNA fragment labeling by fluorescence dye in a microchannel, and to the visualizing of the separation process on a microfabricated chip. We demonstrated that an only 6 mm separation channel is sufficient for the separation of triplet repeat DNA fragment and DNA molecular marker within only 12 s. The separation using the microfabricated capillary electrophoresis device is confirmed to be at least 18 times faster than the same separation carried out by conventional capillary electrophoresis with 24.5 cm effective length. The use of a short capillary with 8.5 cm effective length is also efficient for fast separation of DNA; however, the microchip technology is even faster than capillary electrophoresis using a short capillary.  相似文献   

16.
Read length in DNA sequencing by capillary electrophoresis at elevated temperatures is shown to be greatly affected by the extent of hydrophobicity of the polymer separation matrix. At column temperatures of up to 80 degrees C, hydrophilic linear polyacrylamide (LPA) provides superior read length and separation speed compared to poly(N,N-dimethylacrylamide) (PDMA) and a 70:30 copolymer of N,N-dimethylacrylamide and N,N-diethylacrylamide (PDEA30). DNA-polymer and polymer intramolecular interactions are presumed to be a major cause of band broadening and the subsequent loss of separation efficiency with the more hydrophobic polymers at higher column temperatures. With LPA, these interactions were reduced, and a read length of 1000 bases at an optimum temperature of 70 degrees -75 degrees C was achieved in less than 59 min. By comparison, PDMA produced a read length of roughly 800 bases at 50 degrees C, which was close to the read length attained in LPA at the same temperature; however, the migration time was approximately 20% longer, mainly because of the higher polymer concentration required. At 60 degrees C, the maximum read length was 850 bases for PDMA, while at higher temperatures, read lengths for this polymer were substantially lower. With the copolymer DEA30, read length was 650 bases at the optimum temperature of 50 degrees C. Molecular masses of these polymers were determined by tandem gel permeation chromatography-multiangle laser light scattering method (GPC-MALLS). The results indicate that for long read, rapid DNA sequencing and analysis, hydrophilic polymers such as LPA provide the best overall performance.  相似文献   

17.
Separating DNA sequencing fragments without a sieving matrix.   总被引:1,自引:0,他引:1  
The possibility of separating appropriately labeled DNA fragments using free-flow capillary electrophoresis was predicted a few years ago based on simple theoretical arguments. Free-flow separation of double-stranded DNA (dsDNA) fragments in the 100-1000 base range was later demonstrated using a streptavidin label. In this article, we now report that end-labeled free-flow electrophoresis (ELFSE) can also be used to sequence single-stranded DNA (ssDNA). The first 100 bases of a DNA sequencing reaction were read without any sieving matrix when fractionated streptavidin was added to the 5'-end of the ssDNA fragments. These separations required only 18 min and did not require coated capillaries. An analysis of the results indicates that sample injection, analyte-wall interactions and thermal diffusion are the limiting factors at this time. Extrapolating from our data, we predict that several hundred bases could be sequenced in less than 30 min with the proper conditions. ELFSE thus offers an attractive potential alternative to polymer solutions for DNA sequencing in capillaries and microchips.  相似文献   

18.
Microchip electrophoresis has become a powerful tool for DNA separation, offering all of the advantages typically associated with miniaturized techniques: high speed, high resolution, ease of automation, and great versatility for both routine and research applications. Various substrate materials have been used to produce microchips for DNA separations, including conventional (glass, silicon, and quartz) and alternative (polymers) platforms. In this study, we perform DNA separation in a simple and low-cost polyester-toner (PeT)-based electrophoresis microchip. PeT devices were fabricated by a direct-printing process using a 600 dpi-resolution laser printer. DNA separations were performed on PeT chip with channels filled with polymer solutions (0.5% m/v hydroxyethylcellulose or hydroxypropylcellulose) at electric fields ranging from 100 to 300 V cm(-1). Separation of DNA fragments between 100 and 1000 bp, with good correlation of the size of DNA fragments and mobility, was achieved in this system. Although the mobility increased with increasing electric field, separations showed the same profile regardless of the electric field. The system provided good separation efficiency (215,000 plates per m for the 500 bp fragment) and the separation was completed in 4 min for 1000 bp fragment ladder. The cost of a given chip is approximately $0.15 and it takes less than 10 minutes to prepare a single device.  相似文献   

19.
A microfabricated thin glass chip for contactless conductivity detection in chip capillary electrophoresis is presented in this contribution. Injection and separation channels were photolithographed and chemically etched on the surface of substrate glass, which was bonded with a thin cover glass (100 μm) to construct a new microchip. The chip was placed over an independent contactless electrode plate. Owing to the thinness between channel and electrodes, comparatively low excitation voltage (20–110 V in Vp–p) and frequency (40–65 kHz) were suitable, and favorable signal could be obtained. This microchip capillary electrophoresis device was used in separation and detection of inorganic ions, amino acids and alkaloids in amoorcorn tree bark and golden thread in different buffer solutions. The detection limit of potassium ion was down to 10 μmol/L. The advantages of this microchip system exist in the relative independence between the microchip and the detection electrodes. It is convenient to the replacement of chip and other operations. Detection in different position of the channel would also be available.  相似文献   

20.
Kotler L  He H  Miller AW  Karger BL 《Electrophoresis》2002,23(17):3062-3070
The goal of this work was to reduce the capillary electrophoresis (CE) separation time of DNA sequencing fragments with linear polyacrylamide solutions while maintaining the previously achieved long read lengths of 1000 bases. Separation speed can be increased while maintaining long read lengths by reducing the separation matrix viscosity and/or raising the column temperature. As urea is a major contributor to the separation buffer viscosity, reducing its concentration is desirable both for increase in the separation speed and easier solution replacement from the capillary. However, at urea concentrations below 6 M, the denaturing capacity of the separation buffer is not sufficient for accurate base-calling. To restore the denaturing properties of the buffer, a small amount of an organic solvent was added to the formulation. We found that a mixture of 2 M urea with 5% v/w of dimethyl sulfoxide (DMSO) resulted in 975 bases being sequenced at 70 degrees C in 40 min with 98.5% accuracy. To achieve this result, the software was modified to perform base-calling at a peak resolution as low as 0.24. It is also demonstrated that the products of thermal decomposition of urea had a deleterious effect on the separation performance at temperatures above 70 degrees C. With total replacement of urea with DMSO, at a concentration of 5% v/w in the same linear polyacrylamide (LPA)-containing buffer, it was possible to increase the column temperature up to 90 degrees C. At this temperature, up to 951 bases with 98.5% accuracy could be read in only 32 min of separation. However, with DMSO alone, some groups of C-terminated peaks remained compressed, and column temperature at this level cannot at present be utilized with existing commercial instrumentation.  相似文献   