首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
溶胶凝胶溴离子选择电极的研制与应用   总被引:3,自引:0,他引:3  
报道了一种以溶胶凝胶为载体的溴离子选择电极。电极信号响应线性范围为1 .0× 1 0 - 1~ 1 .0× 1 0 - 5mol/L,斜率为 5 7m V/pc;检出限为 2 .5× 1 0 - 6 mol/L。该电极响应快 ,体积小 ,稳定性和重现性好。电极用作测定溴离子浓度 ,结果令人满意  相似文献   

2.
基于甲醇自由基还原波的甲醇极谱测定   总被引:1,自引:0,他引:1  
利用过硫酸根在电极上还原产生的硫酸根自由基SO4· - 将甲醇氧化成甲醇自由基HC·HOH ,该自由基还原产生极谱还原波 ,拟定了极谱测定甲醇的新方法。在 0 .0 33mol/LKH2 PO4+Na2 HPO4(pH 6.1± 0 .1 ) + 1 .6× 1 0 - 2 mol/LK2 S2 O8介质中 ,甲醇自由基还原波峰电流与甲醇浓度在 3.1 5× 1 0 - 4 mol/L~ 9 46× 1 0 - 3mol/L范围呈线性关系。用该方法测定了甲醇生产车间空气中的甲醇含量  相似文献   

3.
钠型蒙脱石修饰碳糊电极测定微量的铜离子   总被引:3,自引:0,他引:3  
报道了一种高灵敏度 ,快速测定水体中铜离子的化学修饰碳糊电极。详细研究了测定铜离子的条件。该修饰电极测定铜离子的线性范围为 1× 1 0 - 9~ 1 .5× 1 0 - 7mol/L ,富集 6min后的检出限为 3× 1 0 - 10 mol/L。该方法简便、快速、灵敏。用该修饰电极测定了实际水样中的铜离子 ,平均回收率为 1 0 0 .8%。  相似文献   

4.
双硫腙修饰玻碳电极阳极溶出伏安法测定痕量镉和铅   总被引:24,自引:0,他引:24  
黄文胜  杨春海  张升辉 《分析化学》2002,30(11):1367-1370
报道了双硫腙修饰玻碳电极同时测定痕量镉和铅的电分析方法。镉和铅离子通过与电极表面的双硫腙发生螯合作用而富集在电极表面 ,同时在 -1 .2 0V(vs.SCE)还原成零价镉和铅 ,当电极电势从 -1 .2 0V向 -0 .3 0V扫描时 ,被还原的镉和铅从电极表面溶出 ,分别于 -0 .78V和 -0 .4 8V左右形成灵敏的阳极溶出峰。优化了支持电解质及pH值、双硫腙用量、富集电位及时间等实验参数。利用该修饰电极测定镉、铅的线性范围分别为 1 .0×1 0 - 8~ 2 .5× 1 0 - 6 mol L和 5 .0× 1 0 - 9~ 2 .5× 1 0 - 6 mol L。检测限分别为 5 .0× 1 0 - 9mol L和7.0× 1 0 - 1 0 mol L。该法用于实际水样中镉和铅的测定 ,平均回收率分别为 99.3 0 %和 99.5 4 %。  相似文献   

5.
PVC-丁二酮肟膜修饰玻碳电极及其在钯的分析中的应用   总被引:1,自引:0,他引:1  
制备了 PVC-丁二酮肟修饰电极 ,研究了膜电极的响应过程和钯在此电极表面的伏安特性。用微分脉冲伏安法测定 ,钯在 4.76× 1 0 -9mol/ L~ 9.53×1 0 -8mol/ L 的浓度范围内 ,电流与浓度的对数成线性关系 ,检出限为 1 .52×1 0 -9mol/ L。此法可用于矿样中钯的测定。  相似文献   

6.
聚吖啶橙修饰电极伏安法测定黄嘌呤   总被引:2,自引:0,他引:2  
报道了聚吖啶橙 (POAO)修饰电极多阶半微分伏安法测定黄嘌呤 (Xa)。在pH 5 .3的磷酸盐缓冲溶液中 ,Xa在POAO电极上于 0 .8V处产生一灵敏的氧化峰 ,峰电流与其浓度在 7.8× 1 0 - 8~ 1 .1× 1 0 - 6mol/L和 1 .1× 1 0 - 6~ 1 .0×1 0 - 5mol/L范围内呈良好的线性关系 ,检出限为 7.8× 1 0 - 9mol/L。方法可用于人尿中Xa的测定  相似文献   

7.
乳酸氧化酶共价交联于蛋膜上制备乳酸传感器   总被引:1,自引:0,他引:1  
以牛血清白蛋白 戊二醛为交联剂 ,将乳酸氧化酶固定于鸡蛋膜上 ,氧电极作电化学敏感元件 ,制成乳酸氧化酶电极。传感器的线性响应范围为 5 .0×1 0 - 5~ 2 .5× 1 0 - 2 mol/L ,检测限为 2 .0× 1 0 - 5mol/L ,RSD为 1 .4% (n =1 1 ) ,回收率为 97.5 %~ 1 0 4 .0 %。该传感器可用于临床乳酸的测定。  相似文献   

8.
研究了丁二酮肟 氨 氯化铵 柠檬酸钠 明胶 抗坏血酸体系中Cu(Ⅱ )、Cd(Ⅱ )、Ni(Ⅱ )和Co(Ⅱ )的络合物吸附波 ,建立了同时、快速测定锌电解溶液中这些痕量元素的新方法。Cu(Ⅱ )、Cd(Ⅱ )、Ni(Ⅱ )和Co(Ⅱ )分别在 - 0 44V、- 0 76V、- 1 0 7V和 - 1 2 4V左右产生灵敏的络合物吸附波。信噪比为 3时 ,其检测限分别为 1 0× 1 0 - 8mol/L、1 3× 1 0 - 8mol/L、2 9× 1 0 - 1 0 mol/L和 3 6×1 0 - 1 1 mol/L。铜、镉、镍和钴的浓度分别为 2 0× 1 0 - 8mol/L~ 2 0× 1 0 - 5 mol/L、3 0× 1 0 - 8mol/L~ 3 0× 1 0 - 5mol/L、5 4× 1 0 - 1 0 mol/L~ 5 4× 1 0 - 7mol/L和 6 8× 1 0 - 1 1 mol/L~ 6 8× 1 0 - 8mol/L时 ,与相应峰电流之间有良好的线性关系。方法已用于锌电解液中铜、镉、镍和钴的快速同时测定 ,相对标准偏差分别小于或等于 4 7%、5 1 %、4 9%和 5 3 %。  相似文献   

9.
槲皮素化学修饰碳糊电极吸附溶出伏安法测定痕量铅   总被引:14,自引:0,他引:14  
建立了用槲皮素修饰碳糊电极测定痕量铅的新方法 ,在 0 .1 0mol L甲酸盐缓冲液 (pH 4.3 )中 ,于 -0 .1 0V(vs.SCE)搅拌富集 ,再在 -0 .70V静止还原 40s后 ,阳极化扫描 ,于 -0 .42V左右获得一灵敏的铅阳极溶出峰。在最佳条件下 ,富集不同时间 ,其二次导数峰电流与Pb2 + 在 1 .0× 1 0 - 8~ 8.0× 1 0 - 7mol L和 2 .0× 1 0 - 9~ 6.0× 1 0 - 8mol L两个范围内呈线性关系 ,检出限为 8.0× 1 0 - 1 0 mol L(S N =3 )。同时初步探讨了电极反应机理。  相似文献   

10.
曾云龙  唐春然 《分析化学》2001,29(7):799-801
以溴化S 十六烷基双硫腙载体制备了碳酸氢根离子选择性电极 ,选择性次序为 :ClO-4 >SCN->I-~HCO-3 >ClO-3 ~NO-3 >Ac->NO-2 >Cl->H2 PO-4 >SO2 -4 。膜配比 (质量百分比 )为溴化S 十六烷基双硫腙 (SHDTZ)·HCO-3 ∶邻苯二甲酸二异辛酯∶PVC =2 .5∶65.0∶32 .5电极性能最佳。 32℃时 ,在pH 8 30 .1mol/L三乙醇胺 硫酸缓冲溶液中 ,HCO-3 离子浓度在 1 .0× 1 0 -2 ~ 1× 1 0 -5mol/L范围与电极电位呈线性响应 ,检测限为 5.0× 1 0 -6mol/L;斜率为 54± 2mV/decade。研究了HCO-3 离子与载体的作用机理。用该法测定了人体血清中HCO-3 ,结果与滴定法一致。  相似文献   

11.
The potential response of a symmetrical configuration in which the LaF3-membrance is placed between two solutions is discussed. The electrode body provides contact with the inner surface of the fluoride membrane, with a solution containing Fe(CN) 6 3– -Fe(CN) 6 4– redox couple and a Pt wire as internal reference electrode. The electrode was examined in terms of potentialconcentration curves and potential-time response and shown to behave similarly to the commencal Orion fluoride electrode. The advantage of the proposed redox reference system is that the electrode has minimal drift immediately after assembly.  相似文献   

12.
Karami H  Mousavi MF 《Talanta》2004,63(3):743-749
A new dodecyl benzene sulfonate (DBS) ion-selective electrode based on polyaniline is reported. The films of polyaniline doped with DBS were prepared electrochemically on platinum electrodes in the solution containing 1.0×10−3 M aniline and 7.0×10−3 M DBS. The optimum potentiometric response was obtained for prepared polymeric film by passing electricity of 7.5 C cm−2. The electrode exhibits an excellent Nernstian slope of −59.1±0.3 mV per decade for DBS ion over a wide concentration range (5.0×10−6 to 4.1×10−3 M) with a low detection limit (1.0×10−6 M). The proposed electrode revealed good sensitivities for DBS ion over a wide variety of other anions and can be used in the wide pH range of 5-10. It shows good stability, good reproducibility, wide range of pH independency and fast response (<20 s) without using internal solution. This electrode could be used for the determination of DBS in the real samples.  相似文献   

13.
Apte VP  Dhaneshwar RG 《Talanta》1966,13(11):1595-1598
The platinum wire electrode behaves as a good pH electrode in the titration of 1.0 and 0.1N sulphuric or hydrochloric acid with the equivalent concentration of sodium hydroxide. The efficiency is greater when sulphuric acid is used. The end-points obtained are very close to those obtained with a glass-calomel system.  相似文献   

14.
An amperometric enzyme electrode for L-aspartate determination was developed. The probe consisted of a platinum electrode which senses hydrogen peroxide produced from the reactions catalyzed by two enzymes co-immobilized on a preactivated polymeric membrane, α-Ketoglutarate in the presence of L-aspartate was transaminated to L-glutamate by aspartate aminotransferase and the glutamate produced was oxidized by glutamate oxidase, with concomitant production of hydrogen peroxide. Additional protective membranes eliminated interferences from glutamate and most electroactive compounds. The response curve of the probe was linear over the concentration range 1.0 × 10?6 M to 2.0 × 10?4 M aspartate and was useful for at least two months. Aspartic acid in some pharmaceutical products was determined and the results correlated well with a liquid chromatographic reference method and the manufacturer's specification.  相似文献   

15.
Stable, yellow anodic films of parathiocyanogen (SCN) x were formed on a platinum electrode from 2.8 M KSCN in methanol at 45 °C at a constant current of 20–40 mA cm−2 for 15–30 min. Loosely bound orange crystals of a more amorphous character were removed by rinsing to leave an adherent yellow film with sharp Raman bands under 647.1 nm laser excitation at 627 cm−1 (vCS), 1152 cm−1 and 1236–1261 cm−1 (vNN and vCN). The lack of electroactivity and short-lived photocurrents pointed to an insulating film at potentials up to 1.0 V (SHE). At more positive potentials, longer-lasting photocurrents were obtained, consistent with breakdown of the insulating film. XPS scans confirmed N:C:S ratios close to 1:1:1, with a deficiency of S of some 10% due to S lost as sulfate at the film surface. Oxidation of SeCN in neutral aqueous solution led to the formation of a less-stable orange paraselenocyanogen film with a Raman band at 1256–1267 cm−1, which decomposed within a day to grey selenium. Received: 12 December 1997 / Accepted: 23 March 1998  相似文献   

16.
Four-component Ag2S:PbS:PbHPO4: Ag2HPO4 and three-component Ag2S:PbS:PbHPO4 formulations have been prepared and evaluated for sensitivity to monohydrogenphosphate. The 3:1:1 composition is superior in terms of ease of preparation, stability, rapidity of response and reproducibility. Testing was done over the range 10-1–10-5 M HPO42- in buffer at pH 8.44 with constant ionic strength. Response times to 64% of final values varied between 60 and 300 s depending upon concentration, and potential changes with concentration varied between 25 and 31.5 mV/decade in the 10-1–10-3 M range, depending upon electrode configuration. Many common ions interfere.  相似文献   

17.
Golan S  Elata D  Orenstein M  Dinnar U 《Electrophoresis》2006,27(24):4919-4926
In practice, dielectrophoresis (DEP) devices are based on micropatterned electrodes. When subjected to applied voltages, the electrodes generate nonuniform electric fields that are necessary for the DEP manipulation of particles. In this study, electrically floating electrodes are used in DEP devices. It is demonstrated that effective DEP forces can be achieved by using floating electrodes. Additionally, DEP forces generated by floating electrodes are different from DEP forces generated by excited electrodes. The floating electrodes' capabilities are explained theoretically by calculating the electric field gradients and demonstrated experimentally by using test-devices. The test-devices show that floating electrodes can be used to collect erythrocytes (red blood cells). DEP devices which contain many floating electrodes ought to have fewer connections to external signal sources. Therefore, the use of floating electrodes may considerably facilitate the fabrication and operation of DEP devices. It can also reduce device dimensions. However, the key point is that DEP devices can integrate excited electrodes fabricated by microtechnology processes and floating electrodes fabricated by nanotechnology processes. Such integration is expected to promote the use of DEP devices in the manipulation of nanoparticles.  相似文献   

18.
19.
20.
Pickett CJ  Ibrahim SK  Hughes DL 《Faraday discussions》2000,(116):235-44; discussion 257-68
Electrochemical oxidation of the hydrosulfide cluster [Fe4S4(SH)4]2- on gold, platinum or vitreous carbon in a methyl cyanide electrolyte leads to the growth of a conducting film. Spectroscopic and other evidence suggests that the film has cubane centres, predominately in the [4Fe4S]3+ oxidation state, which are linked by disulfide ligands to give an anionic array of [Fe4S4(S approximately)4]n- units. X-ray data suggests some long-range order in the electrode material. The polyferredoxin binds redox active cations consistent with an anionic array.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号