首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
Liu Y  Heyden YV  Mangelings D 《Electrophoresis》2012,33(11):1613-1623
Chiral monolithic silica capillary columns were prepared by immobilization of amylose-3,5-dimethylphenylcarbamate (ADMPC) bearing a small fraction of 3-(triethoxysilyl)propyl residues through intermolecular polycondensation of the triethoxysilyl groups. The obtained columns were used for chiral separations in capillary electrochromatography (CEC). The effects of the silica monolith nature and the used chiral selector concentration on the resulting enantiomeric separations were investigated. Fifteen chiral compounds, including acidic, neutral, and basic substances were evaluated and twelve showed partial or baseline separation at some of the different conditions tested. These results demonstrated the promising applicability of ADMPC-immobilized monolithic silica columns in CEC enantioseparations, but also revealed the need for further improvements on the level of baseline separations and efficiencies.  相似文献   

2.
Amylose tris(5-chloro-2-methylphenylcarbamate) was coated onto native and aminopropylsilanized silica in order to prepare chiral stationary phases (CSP) for enantioseparations using nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC). The effect of the nature of silica, the particle size and pore diameter, the chiral selector loading onto silica, the mobile phase composition and pH, as well as separation variables such as a linear flow rate of the mobile phase, applied voltage in CEC, etc. on the separation of enantiomers was studied. It was found that CSPs based on amylose tris(5-chloro-2-methylphenylcarbamate) can be used for preparation of stable capillary columns for enantioseparations by nano-LC and CEC in combination with polar organic and aqueous–organic mobile phases. Higher peak efficiency was observed in CEC than in nano-LC.  相似文献   

3.
Dong X  Dong J  Ou J  Zhu Y  Zou H 《Electrophoresis》2007,28(15):2606-2612
Enantiomeric separations in CEC with the macrocyclic antibiotic vancomycin immobilized silica monolith as a chiral stationary phase are presented. The monolithic silica capillary columns were prepared by a sol-gel process in fused-silica capillaries with an inner diameter of 50 mum and subsequently in situ immobilization of vancomycin as a chiral selector by reductive amination. Enantioselectivity was obtained for eight pairs of enantiomers in nonaqueous polar organic or aqueous mobile phases and most of them were baseline-separated with high column efficiencies. It was observed that the organic modifier ratio (MeOH/ACN) in the polar organic mobile phase played a significant role in controlling the resolution and efficiency of the enantiomers. In enantiomeric separation of propranolol, repeatability for column efficiency and resolution in the nonaqueous mobile phase was given in terms of RSD values at 1.1 and 2.3% (n = 5) for run-to-run injections and 7.2 and 9.6% (n = 5) for column-to-column testing while repeatability for the separation of thalidomide in the aqueous mobile phase was given in terms of RSD values at 1.5, 2.8% and 6.1, 10.5%, respectively.  相似文献   

4.
The effect of the amount of the chiral selector, cellulose tris(3,5-dichlorophenylcarbamate) (CDCPC) on the separation characteristics of enantiomers of some charged and neutral analytes was studied in capillary electrochromatography (CEC). For better understanding of the effect of the loading of the chiral selector on the particles and pore size of the packing material, laser-beam particle size analyzer and scanning electron microscopy (SEM) were used. As shown in this study, CDCPC can be used for CEC enantioseparations of a wide range of chiral charged and neutral analytes with high efficiency. The loading of the polysaccharide derivative on the surface of silica materials even in high amounts does not markedly affect the particle size and porous structure of the packing material. The separation characteristics are strongly affected by the loading of CDCPC onto silica gel in both CEC and capillary liquid chromatography (CLC).  相似文献   

5.
Polysaccharide derivatives have been extensively used as chromatographic chiral selectors in chiral stationary phases (CSPs) for the separation of enantiomers by HPLC. When coated onto a silica matrix, they represent nowadays one of the most popular type of CSPs. However, they are only compatible with a limited choice of solvents. The main drawback of these CSPs is related to the solubility of the chiral selector in a number of solvents, which limits their applicability. The different attempts which have been described up to now to overcome this problem by covalently fixing the chiral selector to a matrix are reviewed in this paper.  相似文献   

6.
Monolithic capillary columns containing native silica gel were modified with cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) and used for enantioseparations in capillary liquid chromatography. The method adopted for in situ enantioselective modification of monolithic fused silica capillary columns by coating with CDPMC appears to be fairly simple and fast. High efficiency enantioseparations of test racemic compounds and s(everal chiral drugs were achieved in a short time. It was possible to increase the amount of chiral selector present by multiple coating of monoliths with CDMPC. The baseline enantioseparation of 2,2,2-trifluoro-1-(9-anthryl)ethanol was achieved in an analysis time less than 30 s with this capillary column. In addition, reproducible enantioseparations were obtained when the chiral selector was removed from the monolithic column by flushing it with appropriate solvent and the column recoated.  相似文献   

7.
《Electrophoresis》2018,39(8):1086-1095
The chiral organic‐inorganic hybrid materials can exhibit a high loading, and the chiral selector nanoparticles can create efficient stationary phases for open‐tubular capillary electrochromatography (OT‐CEC). Hence, a novel protocol for the preparation of an OT column coated with nano‐amylose‐2,3‐bis(3,5‐dimethylphenylcarbamate) (nano‐ABDMPC)‐silica hybrid sol through in situ layer‐by‐layer self‐assembly method was developed for CEC enantioseparation. By controlling the assembly cycle number of nano‐ABDMPC‐silica hybrid sol, a homogeneous, dense and stable coating was successfully prepared, which was confirmed by SEM and elemental analysis. As the main parameter influencing the chiral separating effect, the nano‐ABDMPC bearing 3‐(triethoxysilyl)propyl residues concentration was investigated. The experimental results showed that 10.0 mg/mL nano‐ABDMPC bearing 3‐(triethoxysilyl)propyl residues coated OT capillary column possessed chiral recognition ability toward the six enantiomers (phenylalanine, tyrosine, tryptophan, phenethyl alcohol, 1‐phenyl‐2‐propanol, and Tröger's base) at some of the different conditions tested. Additionally, the coated OT column revealed adequate repeatability concerning run‐to‐run, day‐to‐day and column‐to‐column. These results demonstrated the promising applicability of nano‐ABDMPC‐silica hybrid sol coated OT column in CEC enantioseparations.  相似文献   

8.
In this work a new type of chiral monolith silica column was developed for the chiral separation by micro high-performance liquid chromatography (micro-HPLC). The chiral monolith column with a continuous skeleton and a large through-pore structure was prepared inside a capillary of 100 microm I.D. by a sol-gel process, and chemically modified with chiral selectors, such as L-phenylalaninamide, L-alaninamide and L-prolinamide, on the surface of the monolithic silica column. Based on the principle of ligand exchange, these chiral monolithic columns were successfully used for the separation of dansyl amino acid enantiomers, as well as hydroxy acid enantiomers by micro-HPLC. The chromatographic conditions, the enantioselectivity and the performance of columns are discussed.  相似文献   

9.
Metal organic frameworks have received great attention as the chiral stationary phase for racemic drug separation because of their fascinating structures and properties. However, the most homochiral metal organic frameworks were constructed by rare and precious chiral organic ligands. In this work, an achiral metal organic framework, together with a natural chiral selector carboxymethyl β-cyclodextrin built a synergistic separation system in the open tubular capillary electrochromatography. The novel coated columns were developed by inducing metal organic framework nanoparticles to grow on the imidazolyl functional capillary inner wall. The baseline separations of hydroxychloroquine, ofloxacin, and atenolol were achieved in the synergistic separation system. The effects of the concentration of chiral selector, pH, voltage, and the concentration of organic additives were studied. Compared with chiral selector auxiliary bare capillary, the resolutions of three drugs were remarkably improved. The relative standard deviations for the retention time of intraday (n = 6), interday (n = 6), and column-to-column were less than 2.1, 2.6, and 5.2%, respectively. These results demonstrate that affordable synergistic separation systems are prospective for racemic drug enantioseparation in capillary electrochromatography.  相似文献   

10.
Chen X  Qin F  Liu Y  Kong L  Zou H 《Electrophoresis》2004,25(16):2817-2824
A positively charged chiral stationary phase (CSP) was prepared by chemically immobilizing cellulose 3,5-dimethylphenylcarbamate onto methacryloyldiethylenetriaminopropylated silica (MCDEAPS) via a radical copolymerization reaction. The prepared CSP was evaluated for enantiomer separation in nonaqueous capillary electrochromatography (CEC). Electroosmotic flow (EOF) generated on the prepared CSP could be significantly improved with introduction of positive charges into the CSP, and separation of enantiomers in CEC has been achieved with mobile phases of ethanol and hexane-ethanol, respectively. In addition, we investigated the solvent versatility of the immobilized CSP on enantioseparations in CEC and capillary liquid chromatography (CLC) due to the elimination of dissolution of chiral selector in a number of solvents. Chiral resolution of some enantiomers was improved by adopting tetrahydrofuran (THF) and chloroform as mobile-phase modifiers, respectively.  相似文献   

11.
Enantioseparations of chiral compounds with different structures were studied in non-aqueous capillary electrochromatography (NAQ CEC). Three different polysaccharide derivatives, cellulose tris(3,5-dimethylphenylcarbamate) (Chiralcel OD), amylose tris(3,5-dimethylphenylcarbamate) (Chiralpak AD) and cellulose tris(4-methylbenzoate) (Chiralcel OJ) were used as chiral stationary phases (CSPs). Methanolic or ethanolic ammonium acetate solutions served as a mobile phase. The effect of the type of the CSP, the loading of the chiral selector on wide-pore aminopropyl derivatized silica gel and operational parameters such as apparent pH, applied voltage, etc. on the EOF and chromatographic characteristics (alpha, N, Rs) were studied. NAQ CEC represents a valuable alternative and an extension to chiral separations by HPLC with common-size columns as well as to capillary LC and CEC in aqueous buffers.  相似文献   

12.
毛细管区带电泳法研究肾上腺素类药物的手性分离   总被引:9,自引:1,他引:8  
使用β-环糊精(β-CD)及β-CD-羧甲基(CM-β-CD)作为手性选择剂,采用毛细管区带电泳法(CZE)对去甲肾上腺素、肾上腺素和异丙肾上腺素的手性分离进行了研究。对影响这类药物手性分离的主要因素〔手性选择剂、背景电解质(BGE)、分离体系的酸度和温度〕进行了讨论,并对手性识别机理进行了探讨。  相似文献   

13.
In this study, diamino moiety functionalized silica nanoparticles with the size of 118 ± 12 nm were successfully synthesized and directly introduced into a chiral capillary electrophoresis system to improve the enantioseparation of 9‐fluorenyl methoxycarbonyl derivatized amino acids using norvancomycin as chiral selector. Under acidic background electrolyte conditions, functional silica nanoparticles can be readily adsorbed onto the inner surface of bare silica capillary column through electrostatic interaction to form a dynamic coating, resulting in a reversed anodic electro‐osmotic flow (i.e. from cathode to anode). As expected, chiral amino acid derivatives (usually negatively charged) can be rapidly separated under co‐electro‐osmotic flow conditions in the current separation system. Furthermore, the column performance and detection sensitivity for the enantioseparation were also obviously improved because the adsorption of chiral selector of norvancomycin to the capillary wall was greatly suppressed. Some important factors influencing the separation, such as the coating thickness, background electrolyte concentration, functional silica nanoparticles concentration, and the organic modifier were also investigated and the optimized separation conditions were obtained.  相似文献   

14.
Cellulose 3,5-dimethylphenylcarbamate was successfully immobilized onto bare silica gel for HPLC through the intermolecular polycondensation of triethoxysilyl groups, which were introduced onto the cellulose derivative via epoxide ring-opening reaction under acidic conditions. The immobilized-type chiral packing material (CPM) exhibited high chiral recognition ability and could be used with various eluents, which are incompatible with the conventional CPMs prepared by coating the derivative onto silica gel.  相似文献   

15.
Chen X  Jin W  Qin F  Liu Y  Zou H  Guo B 《Electrophoresis》2003,24(15):2559-2566
Positively charged chiral stationary phases (CSPs) were prepared for capillary electrochromatography (CEC) separation of enantiomers by chemically immobilizing cellulose derivatives onto diethylenetriaminopropylated silica (DEAPS) with tolylene-2,4-diisocyanate (TDI) as a spacer reagent. Anodic electroosmotic mobility was observed in both nonaqueous and aqueous mobile phases due to the positively charged amines on the surface of the prepared CSPs. For comparison, the traditionally used 3-aminopropyl silica (APS) was also adopted as the base material instead of DEAPS to prepare CSP. It was observed that the EOF on the DEAPS-based CSP was 18%-60% higher than that on the APS-based CSP under nonaqueous mobile phase conditions. Separation of enantiomers in CEC was performed on the positively charged CSPs with the nonaqueous mobile phases of pure ethanol or mixture of hexane-alcohol and the aqueous phases of acetonitrile-water or 95% ethanol. Fast separation of enantiomers was achieved on the newly prepared CSPs.  相似文献   

16.
Capillary electrophoresis (CE) with carboxymethylated beta- or gamma-cyclodextrins was used to achieve the rapid enantiomeric separation of a set of basic drugs. The enantiomers of 12 chiral amino-containing pharmaceutical compounds belonging to various therapeutic categories were analyzed by CE using an uncoated 60 cm x 75 microm I.D. silica capillary. Several experimental parameters such as the nature, concentration and pH of the buffer, nature and concentration of the anionic cyclodextrin and temperature were studied in order to optimize the enantiomeric separation. The variation of the solute partition coefficient for the chiral selector, the enantioselectivity and resolution factors are used to assess the quality of the chiral separation. It is shown that the solute affinity for the chiral selector is not related to its enantioresolution factor. None of the two cyclodextrin selectors used was able to separate the whole set of basic drugs.  相似文献   

17.
The chiral selector 6-azido-2, 3-di(p-chlorophenylcarbamoylated) cellulose was synthesized and further chemically immobilized onto 5-μm amino functionalized spherical porous silica gel. It was used as chiral stationary phase in high-performance liquid chromatography. Thirty racemates were successfully separated into enantiomers in either normal phase mode or reversed-phase mode. Good reproducibility and stability of the chiral stationary phase have been demonstrated.  相似文献   

18.
A new enantioselective open-tubular capillary electrochromatography was developed employing poly(glycidyl methacrylate) nanoparticles/β-cyclodextrin covalent organic frameworks chemically immobilized on the inner wall of the capillary as a stationary phase. A pretreated silica-fused capillary reacted with 3-aminopropyl-trimethoxysilane followed by poly(glycidyl methacrylate) nanoparticles and β-cyclodextrin covalent organic frameworks through a ring-opening reaction. The resulting coating layer on the capillary was characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. The electroosmotic flow was studied to evaluate the variation of the immobilized columns. The chiral separation performance of the fabricated capillary columns was validated by the analysis of the four racemic proton pump inhibitors including lansoprazole, pantoprazole, tenatoprazole, and omeprazole. The influences of bonding concentration, bonding time, bonding temperature, buffer type and concentration, buffer pH, and applied voltage on the enantioseparation of four proton pump inhibitors were investigated. Good enantioseparation efficiencies were achieved for all enantiomers. In the optimum conditions, the enantiomers of four proton pump inhibitors were fully resolved within 10 min with high resolutions of 9.5–13.9. The column-to-column and inter- to intra-day repeatability of the fabricated capillary columns through relative standard deviation were found better than 9.54%, exhibiting satisfactory stability and repeatability of the fabricated capillary columns.  相似文献   

19.
Nonlinear effects caused by molecular association of enantiomers in non-racemic mixtures can cause unexpected effects in chiroptics, NMR spectroscopy, homogeneous catalysis, and chromatography. Herein we present a theoretical model to simulate and verify unusual elution orders of enantiomers on an achiral stationary phase doped with a small amount of a chiral selector or achiral columns coupled with columns doped with a chiral selector. Scenarios with strong, medium, and weak associations of enantiomers, different separation efficiencies typical for flash chromatography and liquid chromatography, and the influence of the enantioselectivity of the chiral selector on the complex equilibria have been investigated. The findings presented here are of importance for the validation of the determination of enantiomeric ratios in not fully separated elution zones as well as for the preparative separation of non-racemic enantiomeric mixtures on chiral stationary phases bonded to achiral matrices.  相似文献   

20.
Dong X  Wu R  Dong J  Wu M  Zhu Y  Zou H 《Electrophoresis》2008,29(18):3933-3940
An approach of immobilizing mobile crystalline material (MCM)-41 mesoporous silica nanoparticles on the inner wall of an open-tubular (OT) capillary as the support for coating chiral selector of cellulose tris(3,5-dimethylphenyl-carbamate) (CDMPC) was carried out. By taking advantage of the improved phase ratio of OT capillary with the immobilization of MCM-41 mesoporous material, the cellulose derivative of CDMPC as the chiral selector was simply coated on the MCM-41 nanoparticle layer via the hydrogen-bonding interaction, and the enantioseparation was successively carried out. Eight pairs of acidic, neutral and basic enantiomers were resolved in capillary electrochromatography or capillary liquid chromatography mode. The concentration of CDMPC for coating was systematically investigated to obtain the optimized chromatographic properties on enantioseparation by controlling the supposed film thickness of CDMPC on MCM-41 nanoparticle layer. Comparing with a bare fused silica capillary column coated with CDMPC under the same coating procedure as MCM-41-modified capillary did, the MCM-41-modified capillary column offered much higher enantioselectivity. This result indicated the significance of using the mesoporous nanoparticles as the electrochromatographic support to enhance the phase ratio of OT capillary column in capillary electrochromatography and capillary liquid chromatography. For investigating the effect of experimental conditions on the enantioseparation with this prepared OT capillary column, the content of organic modifier acetonitrile in the mobile phase was thus extensively evaluated to achieve a better chiral separation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号