首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The common sweeteners aspartame, cyclamate, saccharin and acesulfame K were determined by capillary electrophoresis with contactless conductivity detection. In order to obtain the best compromise between separation efficiency and analysis time hydrodynamic pumping was imposed during the electrophoresis run employing a sequential injection manifold based on a syringe pump. Band broadening was avoided by using capillaries of a narrow 10 μm internal diameter. The analyses were carried out in an aqueous running buffer consisting of 150 mM 2-(cyclohexylamino)ethanesulfonic acid and 400 mM tris(hydroxymethyl)aminomethane at pH 9.1 in order to render all analytes in the fully deprotonated anionic form. The use of surface modification to eliminate or reverse the electroosmotic flow was not necessary due to the superimposed bulk flow. The use of hydrodynamic pumping allowed easy optimization, either for fast separations (80 s) or low detection limits (6.5 μmol L−1, 5.0 μmol L−1, 4.0 μmol L−1 and 3.8 μmol L−1 for aspartame, cyclamate, saccharin and acesulfame K respectively, at a separation time of 190 s). The conditions for fast separations not only led to higher limits of detection but also to a narrower dynamic range. However, the settings can be changed readily between separations if needed. The four compounds were determined successfully in food samples.  相似文献   

2.
Contactless conductivity detection is successfully demonstrated for the enantiomeric separation of basic drugs and amino acids in capillary electrophoresis (CE). Derivatization of the compounds or the addition of a visualization agent as for indirect optical detection schemes were not needed. Non-charged chiral selectors were employed, hydroxypropylated cyclodextrin (CD) for the more lipophilic basic drugs and 18-crown-6-tetracarboxylic acid (18C6H4) for the amino acids. Acidic buffer solutions based on lactic or citric acid were used. The detection limits were determined as 0.3 microM for pseudoephedrine as an example of a basic drug and were in the range from 2.5 to 20 microM for the amino acids.  相似文献   

3.
A purpose-made set-up featuring an automated fast injector allowed the easy optimization of the injected amount and the adjustment of the separation length of conventional capillaries from a minimum of 5 cm upward. It was found that a compromise in capillary length for separation efficiency and analysis time also has to take into account the injected amount, which in turn affects the sensitivity and hence the detection limit. The versatility of the system was demonstrated by the analysis of the major cations and anions in natural water samples in less than 1 min, the concurrent determination of a mixture of amino acids and carbohydrates in 160 s, and of three active ingredients in a pharmaceutical preparation in 40 s. Plate numbers were typically around 50,000 and detection limits down to 1 M could be achieved.  相似文献   

4.
The sensitivity of contactless conductivity detection to amino acids, peptides and proteins in CE was studied for BGE solutions of different pH values. The LOD and analytical characteristics were compared for acidic and basic conditions and better results were in most cases found for buffers of low pH values. Linear dynamic ranges varied between two orders of magnitude for amino acids and peptides and three orders of magnitude for larger proteins. The concentration detection limits were found to be between 1.2 and 7.5 microM for the amino acids tested and for the larger molecules they varied between 2.6 microM for leucine enkephalin and 0.2 microM for HSA when using a buffer at pH 2.1.  相似文献   

5.
Gong XY  Hauser PC 《Electrophoresis》2006,27(2):468-473
The use of contactless conductivity detection for the determination of different organic amines in CE was successfully demonstrated. Aliphatic non UV-absorbing species could be determined along absorbing compounds by measuring the conductivity of their protonated forms. The species tested included short-chained aliphatic primary, secondary and tertiary amines, branched aliphatic amines, diamines, hydroxyl-substituted amines as well as species incorporating aromatic and non-aromatic cyclic moieties. Highest sensitivity was obtained with BGE solutions containing solely acetic acid. A concentration of 0.5 M at a pH value of 2.5 was used. Detection limits were in the order of 1 microM. Complete separation of cis- and trans-1,2-diaminocyclohexane could be achieved by adding 18-crown-6 as modifier to the electrolyte solution.  相似文献   

6.
Xu Y  Li SF 《Electrophoresis》2006,27(20):4025-4028
It was demonstrated that separation of DNA fragments by a CE-contactless conductivity detection system (CE-CCD) could be enhanced with multiple-wall carbon nanotubes (MWCNs) as buffer additive. For HaeIII digest of PhiX174 DNA, optimized MWCN concentration was obtained when the MWCN was above its threshold concentration, at which MWCN could form a network in the buffer as pseudostationary phase to provide additional interaction sites. In the case of larger DNA, MWCN near or below its threshold concentration was enough to provide great improvement of the resolution, which was shown by the separation of the 2-Log DNA ladder. Furthermore, the buffer containing MWCN could provide a more stable baseline in the CE-CCD system, owing to less fluctuation of its conductivity. Compared with CE-UV, CE-CCD with MWCN could provide lower LODs as well as better resolution.  相似文献   

7.
A capillary electrophoresis method with contactless conductivity detection was evaluated as a new approach for quantification of creatine and phosphocreatine in human quadriceps femoris biopsy samples. The running buffers employed consisted of 1 M acetic acid at a pH of 2.3 for the determination of creatine and 50 mM 3-(N-morpholino)propanesulfonic acid/30 mM histidine at a pH of 6.4 for the determination of phosphocreatine in the centrifuged muscle extracts. The limits of detection for creatine and phosphocreatine were found to be 2.5 and 1.0 μM, respectively. Creatine and phosphocreatine were determined in six human muscle biopsy samples and the results were found comparable to those of a standard enzymatic assay. The procedures developed for creatine and phosphocreatine also allow the determination of creatinine as well as adenosine diphosphate and adenosine triphosphate.  相似文献   

8.
CE-C4D methods for the analysis of amino acids (AAs) are presented. Combining the results from two methods with acetic acid and cyclodextrin-based BGEs, 20 proteinogenic AAs could be analyzed using CE. CE-C4D was also, for the first time, applied to analyze free AAs in samples of mammalian cell culture supernatant. After dilution as only sample preparation, combining the results of the two CE methods allowed monitoring the concentration changes of 17 AAs in samples taken during the cultivation of CHO cells.  相似文献   

9.
A portable capillary electrophoretic system with contactless conductivity detection was used for fingerprint analysis of postblast explosive residues from commercial organic and improvised inorganic explosives on various surfaces (sand, concrete, metal witness plates). Simple extraction methods were developed for each of the surfaces for subsequent simultaneous capillary electrophoretic analysis of anions and cations. Dual‐opposite end injection principle was used for fast (<4 min) separation of 10 common anions and cations from postblast residues using an optimized separation electrolyte composed of 20 mM MES, 20 mM l ‐histidine, 30 μM CTAB and 2 mM 18‐crown‐6. The concentrations of all ions obtained from the electropherograms were subjected to principal component analysis to classify the tested explosives on all tested surfaces, resulting in distinct cluster formations that could be used to verify (each) type of the explosive.  相似文献   

10.
A method for the determination of tartaric acid enantiomers using CE with contactless conductivity detection has been developed. Cu(II) as a central metal ion together with l ‐hydroxyproline were used as a chiral selector, the BGE was composed of 7 mM CuCl2, 14 mM trans‐4‐hydroxy‐l ‐proline, and 100 mM ε‐aminocaproic acid; the pH was adjusted to 5 by hydrochloric acid. Separation with a resolution of 1.9 was achieved in 9 min in a polyacrylamide‐coated capillary to suppress the EOF. Various counterions of the BGE were studied, and migration order reversal was achieved when switching from ε‐aminocaproic acid to l ‐histidine. With detection limits of about 20 μM, the method was applied to the analysis of wine and grape samples; only l ‐tartaric acid was found.  相似文献   

11.
An integrated detection circuitry based on a lock-in amplifier was designed for contactless conductivity determination of heavy metals. Combined with a simple-structure electrophoresis microchip, the detection system is successfully utilized for the separation and determination of various heavy metals. The influences of the running buffer and detection conditions on the response of the detector have been investigated. Six millimole 2-morpholinoethanesulfonic acid + histidine were selected as buffer for its stable baseline and high sensitivity. The best signals were recorded with a frequency of 38 kHz and 20 V(pp). The results showed that Mn(2+), Cd(2+), Co(2+), and Cu(2+) can be successfully separated and detected within 100 s by our system. The detection limits for five heavy metals (Mn(2+), Pb(2+), Cd(2+), Co(2+), and Cu(2+)) were determined to range from about 0.7 to 5.4 μM. This microchip system performs a crucial step toward the realization of a simple, inexpensive, and portable analytical device for metal analysis.  相似文献   

12.
A simple microchip CE method integrated with contactless conductivity detection was developed for the direct determination of partition coefficients of selected pharmaceuticals after phase distribution equilibrium. The equilibrium of distribution between two phases for four pharmaceuticals was performed using a 1‐octanol/water system and 1‐octanol/buffer system. During the concentration determination, several major factors affecting detection were investigated in detail for each pharmaceutical to optimize the detection sensitivity. In the optimal conditions, sufficient electrophoretic separation and sensitive detection for each target analyte can be achieved within 40 s. The two systems showed a pH‐dependent partition behavior. Moreover, the measured values showed excellent agreement with those obtained by the traditional shake‐flask method with HPLC–UV detection and literature reports, respectively. The developed method can be successfully applied to measure partition coefficient values of pharmaceuticals and requires much shorter analytical time compared to traditional methods.  相似文献   

13.
The suitability of capillary electrophoresis (CE) with capacitively coupled contactless conductivity detection (C4D) for the direct determination of uric acid in human plasma and urine was investigated. It was found that a careful optimization of the buffer composition and pH was necessary to achieve selective determination in the complex sample matrices. An electrolyte solution consisting of 10 mM 2-morpholinoethanesulfonic acid (MES), 10 mM histidine and 0.1 mM hexadecyltrimethylammonium bromide (CTAB), pH 6.0, was finally found suitable for use as running buffer for both sample matrices. The limit of detection (3 S/N) was determined as 3.3 μM. The linearity of the response was tested for the range between 10 and 500 μM and a correlation coefficient of 0.9996 was obtained. Intra- and inter-day variabilities were <10%. Quantitative analysis of urine and plasma samples showed a good correlation with the routine enzymatic method currently used at the University Hospital of Basel.  相似文献   

14.
In the present study, field-amplified sample stacking injection using the electroosmotic flow pump (FAEP) was developed for the capillary electrophoretic separation of the four nerve agent degradation products methylphosphonic acid (MPA), ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA) and cyclohexyl methylphosphonic acid (CMPA). Coupled to contactless conductivity detection, direct quantification of these non-UV active compounds could be achieved. Sensitivity enhancement of up to 500 to 750-fold could be obtained. The newly established approach was applied to the determination of the analytes in river water and aqueous extracts of soil. Detection limits of 0.5, 0.7, 1.4 and 2.7 ng/mL were obtained for MPA, EMPA, IMPA and CMPA, respectively, in river water and 0.09, 0.14, 0.44 and 0.22 μg/g, respectively, in soil.  相似文献   

15.
In this article, optimization of BGE for simultaneous separation of inorganic ions, organic acids, and glutathione using dual C4D‐LIF detection in capillary electrophoresis is presented. The optimized BGE consisted of 30 mM 2‐[4‐(2‐hydroxyethyl)piperazin‐1‐yl]ethanesulfonic acid, 15 mM 2‐amino‐2‐hydroxymethyl‐propane‐1,3‐diol, and 2 mM 18‐crown‐6 at pH 7.2 and allowed simultaneous separation of ten inorganic anions and cations, three organic acids and glutathione in 20 min. The samples were injected hydrodynamically from both capillary ends using the double‐opposite end injection principle. Sensitive detection of anions, cations, and organic acids with micromolar LODs using C4D and simultaneously glutathione with nanomolar LODs using LIF was achieved in a single run. The developed BGE may be useful in analyses of biological samples containing analytes with differing concentrations of several orders of magnitude that is not possible with single detection mode.  相似文献   

16.
A dynamic supported liquid membrane tip extraction (SLMTE) procedure for the effective extraction and preconcentration of glyphosate (GLYP) and its metabolite aminomethylphosphonic acid (AMPA) in water has been investigated. The SLMTE procedure was performed in a semi-automated dynamic mode and demonstrated a greater performance against a static extraction. Several important extraction parameters such as donor phase pH, cationic carrier concentration, type of membrane solvent, type of acceptor stripping phase, agitation and extraction time were comprehensively optimized. A solution of Aliquat-336, a cationic carrier, in dihexyl ether was selected as the supported liquid incorporated into the membrane phase. Quantification of GLYP and AMPA was carried out using capillary electrophoresis with contactless conductivity detection. An electrolyte solution consisting of 12 mM histidine (His), 8 mM 2-(N-morpholino)ethanesulfonic acid (MES), 75 μM cetyltrimethylammonium bromide (CTAB), 3% methanol, pH 6.3, was used as running buffer. Under the optimum extraction conditions, the method showed good linearity in the range of 0.01–200 μg/L (GLYP) and 0.1–400 μg/L (AMPA), acceptable reproducibility (RSD 5–7%, n = 5), low limits of detection of 0.005 μg/L for GLYP and 0.06 μg/L for AMPA, and satisfactory relative recoveries (90–94%). Due to the low cost, the SLMTE device was disposed after each run which additionally eliminated the possibility of carry-over between runs. The validated method was tested for the analysis of both analytes in spiked tap water and river water with good success.  相似文献   

17.
A sensitive capillary electrophoretic separation method with contactless conductivity detection (C4D) for analysis of five priority haloacetic acids (HAA5) is presented. The analytes were baseline separated in an electrolyte composed of 20 mM 2-(N-Morpholino) ethanesulfonic acid (MES), 20 mM L-histidine (HIS), and 30 μM cetyltrimethylammonium bromide (CTAB) at pH 6.0 in less than 4 min. A simplified solid-phase extraction (SPE) preconcentration procedure on highly cross-linked polystyrene-divinylbenzene (PS-DVB) type sorbent was developed and optimized with respect to short preconcentration time. HAA5 from a 25-mL sample aliquot of tap and swimming pool water could be preconcentrated in less than 5 min using an in-house made SPE column with recoveries ranging from 23 to 98%. Combining the SPE preconcentration procedure with capillary electrophoretic analysis, the attained limits of detection were between 6.1 and 12.2 μg/L with total analysis time of less than 10 min.  相似文献   

18.
Kubán P  Kubán P  Kubán V 《Electrophoresis》2003,24(9):1397-1403
A sensitive, rapid and inexpensive capillary electrophoretic method for the determination of Cr(III) and Cr(VI) species is presented. The method is based on the dual opposite end injection principle and contactless conductometric detection. The sample containing cationic and anionic species is injected into the opposite ends of the separation capillary and after the high voltage is applied, the analytes migrate towards the capillary center, where the cell of a contactless conductivity detector is placed. The method does not require any sample pretreatment, except dilution with deionized water. The separation of Cr(III), Cr(VI) and other common inorganic anions and cations is achieved in less than 4 min. The parameters of the separation electrolyte solution, such as pH and concentration of L-histidine, were optimized. Best results were achieved with electrolyte solution consisting of 4.5 mM L-histidine, adjusted to pH 3.40 with acetic acid. The detection limits achieved for Cr(III) and Cr(VI) were 10 and 39 microg.L(-1), respectively. The repeatability of migration times and peak areas was better than 0.3% and 2.8%, respectively. The developed method was applied to the analyses of rinse water samples from the galvanic industry. The results for the determination of Cr(III) and Cr(VI) were in good agreement with the results obtained by certified differential spectrophotometric method using diphenylcarbazide (CN 83 0520-40) and with the results for the total chromium concentrations determined by electrothermal atomic absorbance spectrometry (ET-AAS) and inductively coupled plasma-mass spectrometry (ICP-MS).  相似文献   

19.
《Electrophoresis》2018,39(19):2425-2430
Determination of natural preservatives using electrophoretic or chromatographic techniques in fermented milk products is a complex task due to the following reasons: (i) the concentrations of the analytes can be below the detection limits, (ii) complex matrix and comigrating/coeluting compounds in the sample can interfere with the analytes of the interest, (iii) low recovery of the analytes, and (iv) the necessity of complex sample preparation. The aim of this study was to apply capillary zone electrophoresis coupled with contactless conductivity detection for the separation and determination of nisin in fermented milk products. In this work, separation and determination of natural preservative–nisin in fermented milk products is described. Optimized conditions using capillary zone electrophoresis coupled with capacitance‐to‐digital technology based contactless conductivity detector and data conditioning, which filter the noise of the electropherogram adaptively to the peak migration time, allowed precise, accurate, sensitive (limit of quantification: 0.02 μg/mL), and most importantly requiring very minute sample preparation, determination of nisin. Sample preparation includes following steps: (i) extraction/dilution and (ii) centrifugation. This method was applied for the determination of nisin in real samples, i.e. fermented milk products. The values of different nisin forms were ranging from 0.056 ± 0.003 μg/mL to 9.307 ± 0.437 μg/g.  相似文献   

20.
Branched chain amino acids (BCAAs), alanine and glutamine are determined in human plasma by capillary electrophoresis with contactless conductivity detection (CE/C4D). The baseline separation of five amino acids from other plasma components is achieved on the short capillary effective length of 18 cm in 3.2 mol/L acetic acid with addition of 13% v/v methanol as background electrolyte. Migration times range from 2.01 min for valine to 2.84 min for glutamine, and LODs for untreated plasma are in the interval 0.7–0.9 μmol/L. Sample treatment is based on the addition of acetonitrile to only 15 μL of plasma and supernatant is directly subjected to CE/C4D. Circulating amino acids are measured in patients with pancreatic cancer and cancer cachexia during oral glucose tolerance test. It is shown that patients with pancreatic cancer and cancer cachexia syndrome exhibit low basal circulating BCAAs and glutamine levels and loss of their insulin-dependent suppression.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号