首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
An indirect catalytic method for the separate microdetermination of oxalate, citrate, and fluoride ions is described. The method is based on the inhibition action of oxalate, citrate, and fluoride ions on the catalytic oxidation reaction of 2,4-diaminophenol-hydrogen peroxide by iron(III).Procedures for the determination of 1.76 × 10−2 to 17.6 × 10−2 μg/ml for oxalate ion, 3.78 × 10−2 to 30.24 × 10−2 μg/ml for citrate ion, and 0.38 to 4.18 μg/ml for fluoride ion are given.Quantities of 1.76 × 10−2 to 17.6 × 10−2 μg/ml for oxalate ion, 3.78 × 10−2 to 30.24 × 10−2 μg/ml for citrate ion, and 0.38 to 4.18 μg/ml for fluoride ion could be determinated with a relative error of about 1–3.5% for oxalate and citrate ions and 1–2% for fluoride ion.  相似文献   

2.
In this study a PVC membrane electrode for determination of ketotifen fumarate is reported, where ketotifen tetraphenylborate (Keto-TPB) was used as ion exchanger. The electrode has linear range of 5.6 × 10− 6–1.0 × 10− 2 and 1.0 × 10− 5–1.0 × 10− 2 mol/L, with detection limits 2.37 × 10− 6and 4.60 × 10− 6 mol/L in batch and flow injection analysis (FIA), respectively. The electrodes show a Nernstian slope value (58.40 and 61.50 mV/decade in batch and FIA, respectively), and the response time is very short (≤ 10 s). The potential is nearly stable over the pH range 2.0–8.0. Selectivity coefficient values towards different inorganic cations, sugars and amino acids reflect high selectivity of the prepared electrodes. These are used for determination of Ketotifen using potentiometric titration and standard addition methods in pure samples and its pharmaceutical preparations (Zaditen tablets and syrup). The average recovery values are 99.5 and 99.2% with RSD 1.4 and 1.2% for potentiometric titrations and standard addition methods, respectively. The electrode response at different temperatures was also studied.  相似文献   

3.
A novel rapid flow injection method with chemiluminescence (CL) detection was established for the determination of ciprofloxacin (CPLX), which is an antibiotic commonly used. The method is based on CL of Ce(IV)–SO32− sensitized by Tb3+–CPLX, and showed the intensive bands characteristic of Tb3+ (5D47F5). The optimum conditions for CL emission were investigated. The linear relationship between the relative CL intensity and the concentration of CPLX is in the range of 9.0×10−9–1.0×10−6 mol/l with a detection limit of 3.1×10−10 mol/l. The relative standard deviation is 2.8% (n=11) for a level of 5.0×10−8 mol/l. The method was applied to the analysis of CPLX in human serum and urine samples with satisfactory results. The possible mechanism for this sensitized CL reaction is also discussed.  相似文献   

4.
The spectral features of the squarylium near-infrared (NIR) dye NN525 in different solutions and its complexation with several metal ions were investigated. The absorbance maximum of the dye is λ=663 nm in methanol. This value matches the output of a commercially available laser diode (650 nm), thus making use of such a source practical for excitation. The emission wavelength of the dye in methanol is λem=670 nm. The addition of either Fe(III) ion or Co(II) ion resulted in fluorescence quenching of the dye. The Stern–Volmer quenching constant, KSV, was calculated from the Stern–Volmer plot to be KSV=2.70×107 M−1 for Co(II) ion. The KSV value for Fe(III) ion could not be established due to the non-linearity of the Stern–Volmer plot and the modified Stern–Volmer plot for this ion. The detection limit is 6.24×10−8 M for Fe(III) ion and 1.55×10−5 M for Co(III) ion. The molar ratio of the metal to the dye was established to be 1:1 for both metal ions. The stability constant, KS, of the metal–dye complex was calculated to be 3.14×106 M−1 for the Fe–dye complex and 2.64×105 M−1 for the Co–dye complex.  相似文献   

5.
Semiautomatic methods are described for the catalytic titrimetric determination of microamounts of silver and mercury(II) using a chloramine-T-selective electrode as monitor. The methods are based on the inhibitory effect of Ag(I) and Hg(II) on the iodide-catalyzed chloramine-T-arsenite and chloramine-T-H2O2 reactions. Microamounts of silver in the range 0.2–200 μg (1 × 10−7−1 × 10−4 M) and of mercury(II) in the range 0.1–200 μg (2.5 × 10−8−5 × 10−5 M) were determined using the chloramine-T-As(III) indicator reaction. Mercury(II) in the range 4–2000 μg (1 × 10−6−5 × 10−4 M) was also determined using the chloramine-T-H2O2 indicator reaction. The accuracy and precision were in the range 0.1–1%.  相似文献   

6.
Yu F  Ding Y  Gao Y  Zheng S  Chen F 《Analytica chimica acta》2008,625(2):195-200
A new spectrofluorimetric method was developed for the determination of trace amounts of DNA using the calcein as a fluorescent probe. In the presence of appropriate amounts of the cationic surfactant cetyl trimethyl ammonium bromide (CTAB), the anionic dye calcein dimerizes. The weak fluorescence intensity of the dimer was enhanced by adding DNA at pH 6–7. The interaction between calcein–CTAB and DNA was studied on the basis of this behavior and a new method was developed for determining DNA. Under the optimal conditions, the enhanced fluorescence intensity was in proportion to the concentration of DNA in the range of 4.0 × 10−6 to 8.0 × 10−5 g L−1 for fsDNA and thermally denatured ctDNA (4.5 × 10−6 to 9.0 × 10−5 g L−1). The detection limits (S/N = 3) were 2.0 × 10−6 and 2.2 × 10−6 g L−1, respectively. This method was used for determining the concentration of DNA in synthetic samples with satisfactory results.  相似文献   

7.
Ionophoric, extraction, acidic and hydrophobic properties of 3-(4-tolylazo)phenylboronic acid (TAPBA) were studied. Determined Kd value equals to 36±2, pKa equals to 8.6±0.5. TAPBA extracts dobutamine from water into chloroform and transports it across a bulk chloroform membrane. The recovery is 83% (pH=7.5), the transport rate – (6.5±0.5)×10−7 mol/h. 1H and 13C NMR data confirm the formation of an 1:1 complex between arylboronic acid and catecholamine. TAPBA was used as electrode-active component of plasticized membrane electrodes with cationic and anionic responses to catecholamines and phenolic acids, respectively. For the diethyl sebacate-plasticized membrane, a slope of electrode function to dobutamine is 56±2 mV/decade; the detection limit is 1.3×10−5 mol/l; the linear range – 5×10−5–1×10−2 mol/l; the working pH-range – 4.8–7.6; the response time – 5–10 s. ISE gives incomplete cationic function to less lipophilic catecholamines. The membrane with cationic additive shows an anionic response to caffeic acid in wide pH range.  相似文献   

8.
At pH 9.75, the resonance light scattering (RLS) intensity of OA–Eu3+ system is greatly enhanced by nucleic acid. Based on this phenomenon, a new quantitative method for nucleic acid in aqueous solution has been developed. Under the optimum condition, the enhanced RLS is proportional to the concentration of nucleic acid in the range of 1.0 × 10−9 to 1.0 × 10−6 g/ml for herring sperm DNA, 8.0 × 10−10 to 1.0 × 10−6 g/ml for calf thymus DNA and 1.0 × 10−9 to 1.0 × 10−6 g/ml for yeast RNA, and their detection limits are 0.020, 0.011 and 0.010 ng/ml, respectively. Synthetic samples and actual samples were satisfactorily determined. In addition, the interaction mechanism between nucleic acid and OA–Eu3+ is also investigated.  相似文献   

9.
A rapid, simple and sensitive spectrofluorimetric method for determination of trace amount of bromazepam is developed. In phosphate buffer of pH 7.4. The bromazepam enhance the luminescence intensity of the Eu3+ ion in Eu3+–bromazepam complex at λex = 390 nm. The produced luminescence intensity of Eu3+–bromazepam complex is in proportion to the concentration of bromazepam. The working range for the determination of bromazepam is 2.3 × 10−8 to 6.2 × 10−7 M with detection limit (LoD) and quantitative detection limit (LoQ) of 3 × 10−9 and 1.2 × 10−8 M, respectively. While, the working range, detection limit (LoD) and quantitative detection limit (LoQ) in case of the quantum yield calculations are 3.7 × 10−8 to 3.4 × 10−7 M with of 3.4 × 10−9 and 9.2 × 10−8 M, respectively. The enhancement mechanism of the luminescence intensity in the Eu3+–bromazepam system has been also explained.  相似文献   

10.
The mediated oxidation of N-acetyl cysteine (NAC) and glutathione (GL) at the palladized aluminum electrode modified by Prussian blue film (PB/Pd–Al) is described. The catalytic activity of PB/Pd–Al was explored in terms of FeIII[FeIII(CN)6]/FeIII[FeII(CN)6]1− system by taking advantage of the metallic palladium layer inserted between PB film and Al, as an electron-transfer bridge. The best mediated oxidation of NAC and GL on the PB/Pd–Al electrode was achieved in 0.5 M KNO3 + 0.2 M potassium acetate of pH 2. The mechanism and kinetics of the catalytic oxidation reactions of the both compounds were monitored by cyclic voltammetry and chronoamperometry. The charge transfer-rate limiting step as well as overall oxidation reaction of NAC or GL is found to be a one-electron abstraction. The values of transfer coefficients α, catalytic rate constant k and diffusion coefficient D are 0.5, 3.2 × 102 M−1 s−1 and 2.45 × 10−5 cm2 s−1 for NAC and 0.5, 2.1 × 102 M−1 s−1 and 3.7 × 10−5 cm2 s−1 for GL, respectively. The modifying layers on the Pd–Al substrate have reproducible behavior and a high level of stability in the electrolyte solutions. The modified electrode is exploited for hydrodynamic amperometry of NAC and GL. The amperometric calibration graph is linear in concentration ranges 2 × 10−6–40 × 10−6 for NAC and 5 × 10−7–18 × 10−6 M for GL and the detection limits are 5.4 × 10−7 and 4.6 × 10−7 M, respectively.  相似文献   

11.
The voltammetric behavior of the LMF-Mg(II) complex with DNA at a mercury electrode is reported for the first time. In NH3–NH4Cl buffer (pH=9.10), the adsorption phenomena of the LMF–Mg(II) complex were observed by linear sweep voltammetry. The mechanism of the electrode reaction was found to be a reduction of LMF in the complex, and the composition of the LMF–Mg(II) complex is 2:1. In the presence of calf thymus DNA (ctDNA), the peak current of LMF–Mg(II) complex decreased considerably, and a new well-defined adsorptive reduction peak appeared at −1.63 V (vs. SCE). The electrochemical kinetic parameters and the binding number of LMF–Mg(II) with ctDNA were also obtained. Moreover, the new peak currents of LMF–Mg(II)–DNA system increased linearly correlated to the concentration of DNA in the 4.00×10−7–2.60×10−6 g ml−1 range when the concentrations of LMF–Mg(II) complex was fixed at 5.00×10−6 mol l−1, with the detection limits of 2.33×10−7 g ml−1. An electrostatic interaction was suggested by electrochemical method.  相似文献   

12.
The characteristics, performance, and application of an electrode, namely, Pt|Hg|Hg2(IBP)2|Graphite, where IBP stands for ibuprofenate ion, are described. This electrode responds to IBP with sensitivity of (58.6 ± 0.9) mV decade 1 over the range 5.0 × 10 5–1.0 × 10 1 mol L 1 at pH 6.0–9.0 and a detection limit of 3.8 × 10 5 mol L 1. The electrode is easily constructed at a relatively low cost with fast response time (within 15–30 s) and can be used for a period of 5 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for ibuprofen in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used for the direct assay of ibuprofen in commercial tablets by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedure.  相似文献   

13.
A model K+ sensor using Prussian blue nanotubes is fabricated by electrochemical deposition of Prussian blue (PB) within the nanochannels of a porous metal-coated membrane with partially covered pore openings. The PB nanotube sensor exhibits excellent stability giving reproducible peak potentials up to 500 measurement cycles, a very low detection limit of 2.0 × 10−8 M and extremely wide logarithmic linear ranges between 5.0 × 10−8–7.0 × 10−4 M and 7.0 × 10−4–1.0 M. Negligible interferences by Na+, Mg2+ and Ca2+ are observed and a rapid analysis time of 30 s is readily achieved. The ease of electrodeposition, high stability of PB nanotubes and outstanding analytical performance which surpasses conventional PB voltammetric and potentiometric sensors demonstrates potential sensing applications including ion sensors and biosensors using PB and other metal hexacyanoferrate nanotubes.  相似文献   

14.
A column method has been established for the preconcentration of aluminum and copper(II) with Alizarin Red S and a cetyltrimethylammonium-perchlorate ion pair supported on naphthalene, using a simple glass-tipped tube. Aluminum and copper(II) react with Alizarin Red S to form water-soluble colored chelate anions. These chelate anions form water-insoluble ternary complexes with the adsorbent on the inactive surface of naphthalene packed into a column. They are quantitatively retained in the pH ranges of 4.7-5.2 for aluminum and 5.0-10.0 for copper. The solid mass is dissolved out from the column with 5 ml of dimethylformamide (DMF) for aluminum and 5 ml of ethanol for copper and the absorbance was measured with a spectrometer at 525 nm for aluminum and at 529 nm for copper. The calibration curves were linear over the concentration ranges of 0.25-5.0 μg of aluminum in 5 ml of DMF solution and 0.50-12.0 μg of copper in 5 ml of ethanol solution. The molar absorptivities and Sandell′s sensitivities were respectively calculated to be 2.8 × 104 liter · mol−1 · cm−1 and 9.62 × 10−4 μg · cm−2 for aluminum and 2.5 × 104 liter · mol−1 · cm−1 and 2.5 × 10−3 μg · cm−2 for copper. Seven replicate determinations of sample solutions containing 2.5 μg of aluminum and 6.0 μg of copper gave mean absorbances of 0.520 and 0.480 with relative standard deviations of 1.67 and 0.33%, respectively. Interference due to various foreign ions has been studied and the method has been applied to the determination of aluminum in standard alloys, tea leaves, vehicle particulates, copper in coal fly ash, and commercial salt samples.  相似文献   

15.
Four short- and long-alkyl-multiamine ligands L1–L4 have been synthesized and characterized. The catalytic efficiency of complex CuL1 and functional metallomicelles CuL2–CuL4 were comparatively investigated for the hydrolysis of bis(p-nitrophenyl) phosphate (BNPP) in buffered solution at 30 °C. The ternary kinetic model for metallomicellar catalysis was suggested to analyze the experimental data. The kinetic and thermodynamic parameters kN, KT and pKa were obtained. The results indicated that the complexes with 1:1 ratio of ligands L2–L4 to copper(II) ion were the kinetic active catalysts, and the deprotonized Cu(II) complex formed by activated water molecule was the real active species for BNPP catalytic hydrolysis. The real rate constant of the reaction catalyzed by CuL1–CuL4 was 4.00 × 10−6, 7.44 × 10−5, 1.42 × 10−4 and 4.10 × 10−4 s−1, respectively. The effects of ligand and microenvironment on the hydrolytic reaction of BNPP have been discussed in detail.  相似文献   

16.
A novel method for fabricating a nanoarray electrode combining the template technique with the self-assembled approach was developed. The glassy carbon electrode was modified with the Au nanoarray using micropores of aluminum anodic film as template. Then, the Au nanoarray electrode was self-assembled with L-cysteine (L-Cys) and gold colloid, respectively. In order to evaluate the electrochemical characteristics of L-Cys–Au colloid self-assembled nanoarray electrode, was chosen as molecule probe and cyclic voltammetry was used. In addition, the functional nanoarray electrode was applied to measuring dopamine (DA). The resulting L-Cys–Au colloid self-assembled nanoarray electrode demonstrated that the linear calibration range extended over three orders of magnitude of DA concentrations (1.0 × 10−9–1.0 × 10−6 mol/L) and the detection limit was 5.0 × 10−10 mol/L.  相似文献   

17.
Mono-/bi-layer Au nanoparticle films with large areas were prepared by the assembly of Au nanoparticles in aqueous colloid at toluene/water interfaces, which can be transferred onto the hydrophilic solid surface and adhere strongly to the substrate without any binding agent. The transferred Au nanoparticle films exhibited satisfactory catalytic performance for electro-oxidizing nitric oxide (NO) in solution, and had a low detection limit (2.7 × 10−8 mol/L), a rapid response time (less than 0.5 s) and a wide linear range (5.0 × 10−8–1.0 × 10−5 mol/L) for the detection of NO in solution. UV–vis spectra, cyclic voltammetry and chronoamperometry were conducted to characterize the prepared Au nanoparticle films.  相似文献   

18.
The voltammetric responses observed for carbohydrates and polyalcohols at 0.60 V in 0.10 M NaOH are significantly larger at preanodized CuMn (95:5) electrodes as compared to preanodized pure Cu electrodes. Apparent values for the number of electrons transferred (napp) and the corresponding values of heterogeneous rate constants (kapp) are estimated for selected reactants from the slopes and intercepts, respectively, of Koutecký–Levich plots of background-corrected voltammetric currents obtained at CuMn and Cu rotated disk electrodes (RDEs). Values of napp (and kapp) for sorbitol and glucose are 11.8 (9.2×10−3 cm s−1) and 11.7 (8.0×10−3 cm s−1), respectively, at a CuMn RDE. These are compared to the values 10.4 (1.8×10−3 cm s−1) and 9.6 (2.0×10−3 cm s−1) for sorbitol and glucose, respectively, at a Cu RDE. The larger sensitivities observed at the CuMn RDE in comparison to the Cu RDE are concluded to be the beneficial result of larger kapp values at the alloy electrode. Furthermore, the larger kapp values are speculated to result from enhanced preadsorption of the reactant species at Mn(IV) sites in the preanodized CuMn surface. In flow-injection measurements, the peak signals obtained for successive injections of glucose using a CuMn electrode (0.60 V vs. SCE) were quite stable with a standard deviation of 1.5%. However, large day-to-day variations (±15%) observed in the average peak signals are attributed to the temperature sensitivities of the kapp value and the diffusion coefficient for glucose.  相似文献   

19.
CuS nanotubes (NTs) made up of nanoparticles were successfully prepared in large quantities in an O/W microemulsion system under low temperature. Based on the characteristics of synchronous fluorescence spectroscopy (SFS), a new method with high sensitivity and selectivity was developed for rapid determination of silver ion with functional copper sulphide (CuS) nanotubes as a fluorescence probe. Under optimal conditions, functional copper sulphide displayed a calibration response for silver ion over a wide concentration range from 1.0 × 10−10 to 1.0 × 10−8 mol L−1. The limit of detection was 0.5 × 10−10 mol L−1 and the relative standard deviation of eight replicate measurements for the highest concentration (1 × 10−8 mol L−1) was 3%. Compared with several fluorescence methods, the proposed method had a wider linear range and improved the sensitivity. Furthermore, the concentration dependence of the synchronous fluorescence intensity is effectively described by a Langmuir-type binding isotherm.  相似文献   

20.
The adsorption of bovine serum albumin (BSA) on fused silica at pH 4.7 was studied at the single molecules level by total-internal-reflection fluorescence microscopy. This pH value was the isoelectric point of BSA. At low [BSA] of 20 pM, protein molecules adsorbed as monomers. At intermediate [BSA] of 500 pM, protein molecules adsorbed as clusters of about five monomers on average. Both monomers and clusters had adsorption rate coefficients of the order 10−7 m s−1 and desorption rate coefficients of about 2 × 10−2 s−1. The respective steady-state coverage was about 10× higher than that at neutral pH, presumably because of the more favorable BSA–silica electrostatics. At pH 4.7 and with [BSA] higher than 100 nM, adsorption begot further adsorption to produce nonlinear isotherms. The coverage at 1 μM BSA was 2.5× that of the linearly extrapolated coverage. This suggests that at pH 4.7, solute–adsorbate affinity was the dominant factor that explains the enhanced adsorption observed in ensemble measurements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号