首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
《Analytical letters》2012,45(10):1430-1443
Abstract

Consecutive polymerase chain reaction (PCR) product electrophoretic separation was done using a high-ionic-strength solution on poly(methyl methacrylate) (PMMA) micofluidic devices. Microchannels were modified with an enhanced static adsorptive coating method using 3% hydroxyethyl cellulose. The relative standard deviations of migration time and fluorescence intensity for the amplified cytosine deaminase PCR product of 258 bp (without pretreatments in 16 consecutive and rapid runs) on the PMMA chip were 0.88% and 3.5%, with a separation efficiency of 6.0 × 105/m. PCR products were repeatedly separated on the modified chip without rinsing the channels with water and refilling the channels with the sieving matrix between runs.  相似文献   

2.
利用基于激光诱导荧光(LIF)检测的芯片毛细管电泳平台,批量制作了低成本聚甲基丙烯酸甲酯(PMMA)芯片,通过修饰管道,优化有效分离距离、分离介质等条件,可在90s内完成DNA片段的分离检测,实现单碱基分离,并在此平台上成功地对遗传性耳聋三个常见突变位点实现分型检测,为这种低成本的PMMA芯片应用于分型相关的临床诊断领域奠定了基础。  相似文献   

3.
This paper deals with dynamic coating of the microchannels fabricated on poly(methyl methacrylate) (PMMA) chips and DNA separation by microchip electrophoresis (MCE). After testing a number of polymers, including 2-hydroxyethyl cellulose, hydroxypropylmethyl cellulose, different sizes of poly(ethylene oxide) (PEO), and poly(vinyl pyrrolidone) (PVP), we found that coating of the PMMA microchannels with PEO(Mr = 6.0 x 10(5) g/mol) on the first layer is essential to minimize the interaction of DNA with PMMA surface. To achieve high efficiency, multilayer coating of PMMA chips with PEO, PVP, and PEO containing gold nanoparticles [PEO(GNP)] is important. A 2-(PEO-PVP)-PEO(GNP) PMMA chip, which was repeatedly coated with 1.0% PEO and 5.0% PVP twice, and then coated with 0.75% PEO(GNP) each for 30 min, provided a high efficiency (up to 1.7 x 10(6) plates/m) for the separation of DNA markers V (pBR 322/HaeIII digest) and VI (pBR 328/BgiI digest and pBR 328/HinfI digest) when using 0.75% PEO(GNP). With such a high efficiency, we demonstrated the separation of hsp65 gene fragments of Mycobacterium HaeIII digests by MCE within 90 s. The advantages of this approach to DNA analysis include ease of filling the microchannel with 0.75% PEO(GNP), rapidity, and reproducibility.  相似文献   

4.
The development of rapid and simple wall coating strategies for high-efficiency electrophoretic separation of DNA is of crucial importance for the successful implementation of miniaturized polymeric DNA analysis systems. In this report, we characterize and compare different methods for the chemical modification of poly(methyl methacrylate) (PMMA) surfaces for the application of wall coating polymers. PMMA surfaces coated with 40 mol% diethylacrylamide and 60 mol% dimethylacrylamide are compared to the PMMA surfaces first oxidized and then coated with hydroxypropylmethyl-cellulose or poly(vinyl alcohol) (PVA). PMMA oxidation was accomplished with UV/ozone or an aqueous solution of HNO(3) to yield hydrogen-bond donors for the spontaneous adsorption of the coating polymers. Contact angle measurements of UV/ozone exposed PMMA surfaces indicate increase in hydrophilicity, and polymer coated surfaces show a strong dependence on the coating polymer and the oxidation method. Fast and repeatable electrophoretic separations of a 10-base and 20-base DNA ladder were performed in PMMA micro CE devices. All analyses were completed in less than 10 min, resulting in the number of theoretical plates as high as 583 000 in a 7.7 cm long separation channel. The duration of UV/ozone treatment was found to have a considerable impact on separation performance. The microchips irradiated with UV for 10 min and coated with PVA as well as the microchips treated with HNO(3) and coated with HPMC were found to have the best separation performance. These results demonstrate facile and robust methods for the surface modification of PMMA enabling low-cost single use devices for electrophoretic DNA separations.  相似文献   

5.
Replica microchips for capillary array electrophoresis containing 10 separation channels (50 microm width, 50 microm depth and 100 microm pitch) and a network of sacrificial channels (100 microm width and 50 microm depth) were successfully fabricated on a poly(methyl methacrylate) (PMMA) substrate by injection molding. The strategy involved development of moving mask deep X-ray lithography to fabricate an array of channels with inclined channel sidewalls. A slight inclination of channel sidewalls, which can not be fabricated by conventional deep X-ray lithography, is highly required to ensure the release of replicated polymer chips from a mold. Moreover, the sealing of molded PMMA multichannel chips with a PMMA cover film was achieved by a novel bonding technique involving adhesive printing and a network of sacrificial channels. An adhesive printing process enables us to precisely control the thickness of an adhesive layer, and a network of sacrificial channels makes it possible to remove air bubbles and an excess adhesive, which are crucial to achieving perfect sealing of replica PMMA chips with well-defined channel and injection structures. A CCD camera equipped with an image intensifier was used to simultaneously monitor electrophoretic separations in ten micro-channels with laser-induced fluorescence detection. High-speed and high-throughput separations of a 100 bp DNA ladder and phi X174 Hae III DNA restriction fragments have been demonstrated using a 10-channel PMMA chip. The current work establishes the feasibility of mass production of PMMA multichannel chips at a cost-effective basis.  相似文献   

6.
Nagata H  Tabuchi M  Hirano K  Baba Y 《Electrophoresis》2005,26(14):2687-2691
In this paper, we describe a method for size-based electrophoretic separation of sodium dodecyl sulfate (SDS)-protein complexes on a polymethyl methacrylate (PMMA) microchip, using a separation buffer solution containing SDS and linear polyacrylamide as a sieving matrix. We developed optimum conditions under which protein separations can be performed, using polyethylene glycol (PEG)-coated polymer microchips and electrokinetic sample injection. We studied the performance of protein separations on the PEG-coated PMMA microchip. The electrophoretic separation of proteins (21.5-116.0 kDa) was completed with separation lengths of 3 mm, achieved within 8 s on the PEG-coated microchip. This high-speed method may be applied to protein separations over a large range of molecular weight, making the PEG-coated microchip approach applicable to high-speed proteome analysis systems.  相似文献   

7.
Belder D  Deege A  Kohler F  Ludwig M 《Electrophoresis》2002,23(20):3567-3573
The channels of microfluidic glass chips have been coated with poly(vinyl alcohol) (PVA). Applied for microchip electrophoresis, the coated devices exhibited a suppressed electroosmotic flow and improved separation performance. The superior performance of PVA-coated channels could be demonstrated by electrophoretic separations of labeled amines and by video microscopy. While a distorted sample zone is injected using uncoated channels the application of PVA-coated channels results in an improved shape of the sample zone with less band broadening. Applying PVA-coated microchips for the separation of amines labeled with Alexa Fluor 350 even sub-second separations, utilizing a separation length of only 650 microm, could be obtained, while this was not possible using uncoated devices. By using PVA-coated devices rather than an uncoated chip a threefold increase in separation efficiencies could be observed. As the electroosmotic flow (EOF) was suppressed, the anionic compounds were detected at the anode whereas the dominant EOF in uncoated devices resulted in an effective mobility to the cathode. Besides improved separation performance another important feature of the PVA-coated channels was the suppressed adsorption of fluorescent compounds in repetitive runs which results in an improved robustness and detection sensitivity. Applying PVA-coated channels, rinsing or etching steps could be omitted while this was necessary for a reliable operation of uncoated devices.  相似文献   

8.
A poly(methylmethacrylate) chip, provided with two separation channels in the column-coupling (CC) arrangement and on-column conductivity detection sensors and intended, mainly, to isotachophoresis (ITP) and ITP-capillary zone electrophoresis (CZE) separations was developed recently. The present work was aimed at assessing its performance relevant to the detection and quantitation of the ITP analytes. Hydrodynamic (HDF) and electroosmotic (EOF) flows of the solution in the separation compartment of the CC chip were suppressed and electrophoresis was a dominant transport process in the ITP separations with model analytes carried out in this context. When the surfaces of the detection electrodes of the conductivity sensors on the chip were appropriately cleaned qualitative indices of the test analytes [relative step heights (RSHs)], provided by a particular detection sensor, agreed within 1% (expressed via RSDs of the RSH values). Their long-term reproducibilities for one sensor, as estimated from 70 ITP runs repeated in 5 days, were 2% or less. Sensor-to-sensor and chip-to-chip fluctuations of the RSH values for the test analytes were 2.5% or less. In addition, experimentally obtained RSH values agreed well with those predicted by the calculations based on the ITP steady-state model. Reproducibilities of the migration velocities attainable on the CC chips with suppressed EOF and HDF, assessed from the migration time measurements of the ITP boundary between well-defined positions on the separation channels of the chips (140 repeated runs on three chips), ranged from 1.4 to 3.3% for the migration times in the range of 100-200 s. Within-day repeatabilities of the time-based zone lengths for the test analytes characterized 2% RSDs, while their day-to-day repeatabilities were less than 5%. Chip-to-chip reproducibilities of the zone lengths, assessed from the data obtained on three chips for 100 ITP runs, were 5-8%.  相似文献   

9.
微流控芯片技术因具有微量、快速、高效和高通量等特点,已成为分析化学领域中的研究热点之一.在微流控芯片中,最常见的可用作芯片的材料为玻璃、石英和各种塑料.玻璃和石英有很好的电渗性和光学性质,可采用标准的刻蚀工艺加工和用化学方法进行表面改性,但加工成本较高,封接难度较大.  相似文献   

10.
Huang FC  Chen YF  Lee GB 《Electrophoresis》2007,28(7):1130-1137
This study presents a new packaging method using a polyethylene/thermoplastic elastomer (PE/TPE) film to seal an injection-molded CE chip made of either poly(methyl methacrylate) (PMMA) or polycarbonate (PC) materials. The packaging is performed at atmospheric pressure and at room temperature, which is a fast, easy, and reliable bonding method to form a sealed CE chip for chemical analysis and biomedical applications. The fabrication of PMMA and PC microfluidic channels is accomplished by using an injection-molding process, which could be mass-produced for commercial applications. In addition to microfluidic CE channels, 3-D reservoirs for storing biosamples, and CE buffers are also formed during this injection-molding process. With this approach, a commercial CE chip can be of low cost and disposable. Finally, the functionality of the mass-produced CE chip is demonstrated through its successful separation of phiX174 DNA/HaeIII markers. Experimental data show that the S/N for the CE chips using the PE/TPE film has a value of 5.34, when utilizing DNA markers with a concentration of 2 ng/microL and a CE buffer of 2% hydroxypropyl-methylcellulose (HPMC) in Tris-borate-EDTA (TBE) with 1% YO-PRO-1 fluorescent dye. Thus, the detection limit of the developed chips is improved. Lastly, the developed CE chips are used for the separation and detection of PCR products. A mixture of an amplified antibiotic gene for Streptococcus pneumoniae and phiX174 DNA/HaeIII markers was successfully separated and detected by using the proposed CE chips. Experimental data show that these DNA samples were separated within 2 min. The study proposed a promising method for the development of mass-produced CE chips.  相似文献   

11.
L Song  D Fang  R K Kobos  S J Pace  B Chu 《Electrophoresis》1999,20(14):2847-2855
The separation of double-stranded DNA (dsDNA) fragments in polymethylmethacrylate (PMMA) capillary electrophoresis (CE) chips by using E99P69E99 as a separation medium has been demonstrated. The PMMA CE chips were simply manufactured by micromachining and adhesive tape sealing. To make the separation channel compatible with the separation medium, a dynamic nonionic surfactant coating procedure was developed, which made the plastic separation channel sufficiently hydrophilic to allow the separation medium to fill the channel by capillary action. Subsequent separation of DNA fragments was successful with a separation efficiency of the order of 10(4) theoretical plates over an effective separation distance of 1.5 cm. By using an applied electric field strength of 200 V/cm, the separation of low DNA mass ladder was completed within 5 min. The simple coating procedure, together with the self-assembled viscosity-adjustable separation medium, should be useful to meet some of the essential requirements for developing single-use disposable CE chips. Coating the channels with polymer blends of PMMA and the separation medium also showed promise.  相似文献   

12.
Ma R  Crabtree HJ  Backhouse CJ 《Electrophoresis》2005,26(14):2692-2700
As microfluidic chips come to integrate the higher levels of functionality required for the implementation of advanced bioanalytical protocols, a crucial factor is that of cost. Although glass chips provide advantages in multilayer integrations, their cost is far higher than that of polymer chips. However, a simple and effective rejuvenation protocol for glass microchips may enable higher levels of integration and functionality on glass microchips. Here we present a method to rejuvenate glass microchips that had been used for capillary electrophoresis to the extent that their performance was degraded. This degradation was due to one of the two mechanisms: (i) a deterioration of the polymer coating on the inner surface of the microchannel or (ii) an aging of the glass substrate. Using the method presented here, we have rejuvenated more than 50 such "aged" microchips. The performance of these microchips was fully restored after the rejuvenation and lasted for hundreds of DNA separation runs. Our experiments indicate that the loss of resolution in microchip separations was not associated with glass aging, but was due to the degradation of the polymer coating on the inner surface of microchannels. This suggests that it is possible to extend the microchip lifetime "forever" using the rejuvenation protocol and that the exploration of higher levels of integration and functionality on glass microchips (or of hybrid structures involving materials capable of withstanding the reagents and elevated temperatures used) is feasible.  相似文献   

13.
We have evaluated double-stranded DNA separations in microfluidic devices which were designed to couple a sample preconcentration step based on isotachophoresis (ITP) with a zone electrophoretic (ZE) separation step as a method to increase the concentration limit of detection in microfluidic devices. Developed at ACLARA BioSciences, these LabCard trade mark devices are plastic 32 channel chips, designed with a long sample injection channel segment to increase the sample loading. These chips were designed to allow stacking of the sample into a narrow band using discontinuous ITP buffers, and subsequent separation in the ZE mode in sieving polymer solutions. Compared to chip ZE, the sensitivity was increased by 40-fold and we showed baseline resolution of all fragments in the PhiX174/HaeIII DNA digest. The total analysis time was 3 min/sample, or less than 100 min per LabCard device. The resolution for multiplexed PCR samples was the same as obtained in chip ZE. The limit of detection was 9 fg/microL of DNA in 0.1xpolymerase chain reaction (PCR) buffers using confocal fluorescence detection following 488 nm laser excitation with thiazole orange as the fluorescent intercalating dye.  相似文献   

14.
Xu F  Jabasini M  Baba Y 《Electrophoresis》2002,23(20):3608-3614
Low-viscosity polymer solutions have potential for double-stranded (ds) DNA separations in micrototal analysis systems (micro-TAS). In this paper, we report dilute, low-viscosity hydroxypropylmethylcellulose-50 (HPMC-50, 11.5 kDa) solutions containing polyhydroxy additives as separation media. Predominant operational variables, such as applied electric field strength, fluorescent intercalator (YOPro-1) concentration, polymer concentration, and additive concentration, are thoroughly investigated. Fast (within 170 s) and excellent separation of DNA restriction fragments ranging in size from 72 to 1353 base pairs (bp) is achieved in a 30 mm length channel of polymethylmethacrylate (PMMA) microchips at an electric field strength of 300 V/cm, by introducing 8% mannitol, 8% glucose or 10% glycerol additives into a 2% HPMC-50/1 x Tris-borate-EDTA (TBE) solution. The low-viscosity (40 cP) matrix formulation provides both coating of the microchannels and separation of DNA in one step. The performance in the solution surpasses that in highly concentrated HPMC-50 solution. In addition, separation using 1xTris-EDTA buffer in the 2% HPMC-50 matrix containing polyhydroxy additives also exhibits a notably increased performance. This is presumably due to formation of hydrogen-bonding interactions of polyhydroxy additives with HPMC-50 matrix and DNA so as to increase the coupling interactions between matrix and DNA molecules during electrophoresis. The result reflects that boric acid is not a prerequisite in polyhydroxy-enhanced HPMC-50 solution for separation.  相似文献   

15.
A coating procedure based on the physical adsorption of hydroxypropyl cellulose onto the wall of a capillary column has been successfully used for the separation of DNA fragments up to 500 bp. The method uses a running Tris-phosphate-EDTA buffer containing 2-hydroxyethyl cellulose as sieving polymer. The separation procedure shows good reproducibility (measured as RSD%) for consecutive runs (<0.64), for different days (< 1.15) and capillaries (<2.15), short analysis times, and a long coating lifetime. Good reproducibility and efficiency are even achieved by performing the separation in the presence of additives such as ethidium bromide and mannitol. The method is applied to the detection of GMOs in soybean and maize meals with an accurate evaluation of the length of DNA sequences, previously amplified by polymerase chain reaction.  相似文献   

16.
Belder D  Kohler F  Ludwig M  Tolba K  Piehl N 《Electrophoresis》2006,27(16):3277-3283
Channels in microfluidic glass chips manufactured with the alternative powder blasting technology were permanently coated with poly(vinyl alcohol) (PVA) in order to improve the performance in microchip electrophoresis. The performance of coated and uncoated powder-blasted (pb) devices as well as coated and uncoated wet chemical etched (wc) chips was compared in electrophoretic separations of fluorescently labeled test compounds. The limited electrophoretic resolution obtained in pb-chips could significantly be improved by coating the channels with PVA. The resolution of test compounds in such coated pb-devices was even higher than in uncoated wc-chips. PVA-coated pb-chips could also successfully be applied in chiral separations. While in an uncoated pb-chip using a cyclodextrins buffer only one broad signal was obtained, two well-resolved signals were obtained in a coated device.  相似文献   

17.
Yang R  Shi R  Peng S  Zhou D  Liu H  Wang Y 《Electrophoresis》2008,29(7):1460-1466
We present cationized hydroxyethylcellulose (cat-HEC) synthesized in our laboratory as a novel physically adsorbed coating for CE. This capillary coating is simple and easy to obtain as it only requires flushing the capillary with polymer aqueous solution. A comparative study with and without polymers was performed. The adsorbed cat-HEC coating exhibited minimal interactions with basic proteins, providing efficient basic protein separations with excellent reproducibility. Under broad pHs, the amine groups are the main charged groups bringing about a global positive charge on the capillary wall. As a consequence, the cat-HEC coating produced an anodal EOF performance. A comparative study on the use of hydroxyethylcellulose (HEC) and cat-HEC as physically adsorbed coatings for CE are also presented. The separation efficiency and analysis reproducibility proved that the cat-HEC polymer was efficient in suppressing the adsorption of basic proteins onto the silica capillary wall. The long-term stability of the cat-HEC coating in consecutive protein separation runs has demonstrated the suitability of the coating for high-throughput electrophoretic protein separations.  相似文献   

18.
Injection molded poly(methylmethacrylate) (IM-PMMA), chips were evaluated as potential candidates for capillary electrophoresis disposable chip applications. Mass production and usage of plastic microchips depends on chip-to-chip reproducibility and on analysis accuracy. Several important properties of IM-PMMA chips were considered: fabrication quality evaluated by environmental scanning electron microscope imaging, surface quality measurements, selected thermal/electrical properties as indicated by measurement of the current versus applied voltage (I-V) characteristic and the influence of channel surface treatments. Electroosmotic flow was also evaluated for untreated and O2 reactive ion etching (RIE) treated surface microchips. The performance characteristics of single lane plastic microchip capillary electrophoresis (MCE) separations were evaluated using a mixture of two dyes-fluorescein (FL) and fluorescein isothiocyanate (FITC). To overcome non-wettability of the native IM-PMMA surface, a modifier, polyethylene oxide was added to the buffer as a dynamic coating. Chip performance reproducibility was studied for chips with and without surface modification via the process of RIE with O2 and by varying the hole position for the reservoir in the cover plate or on the pattern side of the chip. Additionally, the importance of reconditioning steps to achieve optimal performance reproducibility was also examined. It was found that more reproducible quantitative results were obtained when normalized values of migration time, peak area and peak height of FL and FITC were used instead of actual measured parameters.  相似文献   

19.
Du M  Flanagan JH  Lin B  Ma Y 《Electrophoresis》2003,24(18):3147-3153
The detection of point and other simple mutations in DNA is important for cancer research and diagnosis and other biological studies. Capillary electrophoresis has been successfully used for separating DNA fragments. However, a low-viscosity polymer sieving buffer for DNA separation with on-line coating has never been reported. In this paper, a new method using capillary electrophoresis with on-line coating and laser-induced fluorescence detection (CE-LIF) for screening for point or simple DNA mutations has been demonstrated. The method uses an on-line dynamic coating technique that increases capillary lifetime and analysis reproducibility, and employs a low-viscosity polymer solution, which allows the user to rinse the capillary rapidly and refill with polymer solution easily. Experiments proved that the additives in the separation buffer for on-line capillary coating do not affect the separation efficiency of the running buffer, and do not interfere with the formation of hydrogen-bonded network between boric acid, mannitol and hydroxypropylmethylcellulose polymers. The stability of the dynamically coated capillary was quantitatively studied; the capillary lifetime was increased 6- to 7-fold compared with that of permanently coated CE columns. Standard DNA fragments containing mutations, with sizes of 209, 219, and 338 bps, were successfully separated and detected with this system, after the mutated DNA fragments were cleaved by CEL-I endonuclease. The technique is very sensitive for the size-separation of low-range, middle-range, and high-range DNA fragments. Results were compared with the HPLC methods developed by Transgenomic, Inc. and were in good agreement. The method should be applicable to mutation detection for all relevant biological and clinical studies. The factors influencing separations and the stability of dynamic capillary coatings are also discussed in the paper.  相似文献   

20.
We present the polymer poly-N-hydroxyethylacrylamide (PHEA) (polyDuramide) as a novel, hydrophilic, adsorbed capillary coating for electrophoretic protein analysis. Preparation of the PHEA coating requires a simple and fast (30 min) protocol that can be easily automated in capillary electrophoresis instruments. Over the pH range of 3-8.4, the PHEA coating is shown to reduce electroosmotic flow (EOF) by about 2 orders of magnitude compared to the bare silica capillary. In a systematic comparative study, the adsorbed PHEA coating exhibited minimal interactions with both acidic and basic proteins, providing efficient protein separations with excellent reproducibility on par with a covalent polyacrylamide coating. Hydrophobic interactions between proteins and a relatively hydrophobic poly-N,N-dimethylacrylamide (PDMA) adsorbed coating, on the other hand, adversely affected separation reproducibility and efficiency. Under both acidic and basic buffer conditions, the adsorbed PHEA coating produced an EOF suppression performance comparable to that of covalent polyacrylamide coating and superior to that of adsorbed PDMA coating. The protein separation performance in PHEA-coated capillaries was retained for 275 consecutive protein separation runs at pH 8.4, and for more than 800 runs at pH 4.4. The unique and novel combination of hydrophilicity and adsorptive coating ability of PHEA makes it a suitable wall coating for automated microscale analysis of proteins by capillary array systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号