首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel method for paralytic shellfish poisoning (PSP) toxins which is based on the chromatographic separation of the toxins using a zwitterionic (ZIC) hydrophilic interaction chromatography (HILIC) column is presented. Efficient retention of the polar PSP toxins on the ZIC-HILIC column allowed their selective and sensitive determination by the application of mass spectrometric (MS/MS) detection or as derivatives after oxidation prior to fluorescence detection (FD). Low buffer concentrations and the omission of ion-pair reagents decreased the limits of detection (LODs) by MS/MS analysis and showed a good linearity for both methods of detection. This method can be applied for the qualitative and quantitative determination of PSP toxins in various types of phytoplankton, and for the routine analysis of seafood.  相似文献   

2.
Systemin is an important group of plant peptide hormones participating in the regulation of plant defensive responses. An improved method, based on dynamic pH junction and capillary electrophoresis‐quadrupole time‐of‐flight mass spectrometry, was developed for online enrichment and sensitive determination of trace systemins in plants. After optimization, the online enrichment factors for six target systemins ranged from 90‐ to 127‐fold. The detection limits reached lower than 0.5 nM, which were comparable with the sensitivity of LC‐MS method. Satisfactory quantitative results were obtained in terms of linearity (R2 ≥ 0.993), dynamic range (3–120 ng/mL), and reproducibility (≤6.7%). For the analysis of real plant samples, a rapid sample preparation method was developed, using two steps of SPE purification with different retention and separation mechanisms. Finally, this method realized the successful detection of tomato systemin and tobacco hydroxyproline‐rich systemin I from plant leaves with shorter analysis time.  相似文献   

3.
A flow injection analysis coupled with electrochemical detection at an activated barrel plating nickel electrode (Ni-BPE) was developed as a sensitive, simple, and low-cost formaldehyde sensor. The mechanism of Ni-BPE toward the electrocatalytic oxidation of formaldehyde in alkaline medium at ambient temperature was proposed to be based on the electrocatalytic oxidation of formaldehyde by Ni(III)O(OH) species. Under the optimized conditions (flow rate = 1.2 mL/min; detection potential = +0.5 V versus Ag/AgCl), a good linearity in the window of 0.037 to 10 microg/mL formaldehyde was observed, and the LOD of 0.23 microg/L was calculated. The RSDs of intraday (n = 10) and interday (n = 6) replicate measurements of 0.185-5 microg/mL formaldehyde ranged from 1.45 to 3.60%, indicating good reproducibility of the proposed method. The proposed method was successfully applied to the determination of formaldehyde in commercial nail polish samples and a drinking water sample.  相似文献   

4.
Alwarthan AA  A Aly F 《Talanta》1998,45(6):1131-1138
A chemiluminescent method using flow injection is described for the determination of pyridoxine hydrochloride. Its detection limit, linearity and reproducibility were examined. The method is based on the enhancing effect of pyridoxine hydrochloride on the chemiluminescence generated by the oxidation of luminol with hydrogen peroxide in aqueous potassium hydroxide and sodium oxalate. The proposed method is simple and inexpensive. The chemiluminescence intensity is a linear function of pyridoxine hydrochloride concentration over the range 10–250 μg ml−1 with a detection limit of 6 μg ml−1. The applicability of the method was demonstrated by the determination of pyridoxine hydrochloride in different tablet formulations and some dietary sources.  相似文献   

5.
The feasibility of a microfluidic-based liquid chromatography-electrospray ionization/mass spectrometric system (HPLC-Chip/ESI/MS) was studied and compared to a conventional narrow-bore liquid chromatography-electrospray ionization/mass spectrometric (LC-ESI/MS) system for the analysis of steroids. The limits of detection (LODs) for oxime derivatized steroids, expressed as concentrations, were slightly higher with the HPLC-Chip/MS system (50–300 pM) using an injection volume of 0.5 μL than with the conventional LC-ESI/MS (10–150 pM) using an injection volume of 40 μL. However, when the LODs are expressed as injected amounts, the sensitivity of the HPLC-Chip/MS system was about 50 times higher than with the conventional LC-ESI/MS system. The results indicate that the use of HPLC-Chip/MS system is clearly advantageous only in the analysis of low-volume samples. Both methods showed good linearity and good quantitative and chromatographic repeatability. In addition to the instrument comparisons with oxime derivatized steroids, the feasibility of the HPLC-Chip/MS system in the analysis of non-derivatized and oxime derivatized steroids was compared. The HPLC-Chip/MS method developed for non-derivatized steroids was also applied to the quantitative analysis of 15 mouse plasma samples.  相似文献   

6.
Anabolic androgenic steroids (AAS) are metabolized extensively in the human body, resulting mainly in the formation of glucuronide conjugates. Current detection methods for AAS are based on gas chromatographic/mass spectrometric (GC/MS) analysis of the hydrolyzed steroid aglycones. These analyses require laborious sample preparation steps and are therefore time consuming. Our interest was to develop a rapid and straightforward method for intact steroid glucuronides in biological samples, using liquid-phase microextraction (LPME) sample clean-up and concentration method combined with liquid chromatographic/tandem mass spectrometric (LC/MS/MS) analysis. The applicability of LPME was optimized for 13 steroid glucuronides, and compared with conventional liquid-liquid extraction (LLE) and solid-phase extraction (SPE) procedures. An LC/MS/MS method was developed for the quantitative detection of AAS glucuronides, using a deuterium-labeled steroid glucuronide as the internal standard. LPME, owing to its high specificity, was shown to be better suited than conventional LLE and SPE for the clean-up of urinary AAS glucuronides. The LPME/LC/MS/MS method was fast and reliable, offering acceptable reproducibility and linearity with detection limits in the range 2-20 ng ml(-1) for most of the selected AAS glucuronides. The method was successfully applied to in vitro metabolic studies, and also tested with an authentic forensic urine sample. For a urine matrix the method still has some unsolved problems with specificity, which should be overcome before the method can be reliably used for doping analysis, but still offering additional and complementary data for current GC/MS analyses.  相似文献   

7.
Two methods were developed for the quantitative analysis of phenolic acids in herb extracts. The methods were based on liquid chromatography–time-of-flight mass spectrometry (LC–TOFMS) and gas chromatography–mass spectrometry (GC–MS). The methods were compared in terms of their linearity, repeatability, selectivity, sensitivity and the speed of the analysis. The sensitivity was good for both methods, with limits of detection of <80 ng/ml for most of the compounds. The relative standard deviations (RSD) of the peak areas were on average 7.2% for the LC–TOFMS method and 1.4% for the GC–MS method. Both methods were found to be suitable for the determination of the target analytes, although GC–MS was better suited to the quantitative determination of compounds present at low concentrations.  相似文献   

8.
Rabeprazole sodium is a proton pump inhibitor that covalently binds and inactivates the gastric parietal cell proton pump (H+/K+ ATPase). Little has been published about the quantitative determination of this drug. The aim of this research was to develop a new liquid chromatographic method for quantitative determination of rabeprazole in coated tablets. The system consisted of a Hypersil Keystone Betabasic C8 column (250 x 4.6 mm, 5 microm particle size), an isocratic acetonitrile-water (35 + 65) mobile phase at a flow rate of 1.0 mL/min, and a diode array detector set at 282 nm. The following validation parameters were evaluated: linearity, precision, accuracy, specificity, detection and quantitation limits, and robustness. The method showed good linearity in the concentration range of 10-70 microg/mL. The quantitation limit was 2.43 microg/mL, and the detection limit was 0.80 microg/mL. The intra- and interday precision data showed that the method has good reproducibility (relative standard deviation = 1.03). Accuracy and robustness were also evaluated, and the results were satisfactory. The mean recovery was 101.61%. The analysis of a placebo mixture demonstrated the method is also specific.  相似文献   

9.
厉欣  江新宁  邹汉法 《色谱》2008,26(2):189-194
建立了一种基于毛细管反相液相色谱-串联质谱联用技术和质谱峰强度数据处理的肽段鉴定和相对定量分析方法。该方法无需对样品中的肽进行化学标记,在对样品进行反相色谱分离和串联质谱分析后,将二级质谱扫描数据进行蛋白质数据库搜索,获得所鉴定肽段的序列、保留时间、质荷比、带电荷数等定性信息;再以此为定位依据,在全扫描质谱数据中提取该肽段对应的离子峰并以该离子峰的峰强度作为定量信息,从而实现对不同样品中的共有肽段进行差异比较分析。以标准蛋白酶解混合肽段为实验对象,以肽段相对强度的相对标准偏差为指标,考察了该方法用于肽段相对定量分析的重现性、检测动态范围以及浓度标准曲线等,为将该方法用于生物样品中内源性肽的差异分析奠定了基础。  相似文献   

10.
The present work describes the development and validation of an analytical method based on liquid chromatography (LC), coupled with tandem mass spectrometry (MS/MS) that allows the determination and confirmation of several endocrine-disrupting chemicals (EDCs) in honey. The EDCs studied were nine phenols of different nature: chlorophenols (2,4-dichlorophenol, 2,4,5-trichlorophenol, and pentachlorophenol), alkylphenols (4-tert-butylphenol, 4-tert-octylphenol, and 4-n-octylphenol) bisphenols (bisphenol-A and bisphenol-F), and 4-tert-butylbenzoic acid. The method incorporates a restricted-access material (RAM), coupled on-line to the LC-MS/MS system, which allows direct injection of the matrix into the RAM-LC-MS/MS system. The optimized method developed, RAM-LC-MS/MS, was applied to fortified honey samples, affording detection limits in the 0.6–7.2 ng g−1 range, calculated for a signal-to-noise ratio of 3. In addition, the method was validated as a quantitative confirmatory method according to European Union Decision 2002/657/EC. The validation criteria evaluated were linearity, repeatability, reproducibility, recovery, decision limits, detection capabilities, specificity, and ruggedness. Repeatability and within-laboratory reproducibility were evaluated at two concentration levels, being ±11% or below at 20 ng g−1. The decision limits (CCα) and detection capabilities (CCβ) were in the 1.7–12.6 and 2.8–21.6 ng g−1 range, respectively.  相似文献   

11.
活性碳纤维固相微萃取/气相-质谱联用测定水中苯系物   总被引:17,自引:0,他引:17  
贾金平  冯雪  方能虎  黄加量 《色谱》2002,20(1):63-65
 对直接进样、二硫化碳萃取和活性碳纤维固相微萃取 (ACF SPME)分别与气相 质谱联用测定水中的苯系物的方法进行了比较研究。对 3种方法的线性、重复性、最小检出限等进行了试验测定。测定结果表明 ,固相微萃取在灵敏度方面优于其他方法 ,但在重复性方面还有待提高。利用固相微萃取方法进行了实际废水样的检测及回收率试验 ,结果令人较为满意。  相似文献   

12.
A capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) method was developed to facilitate identification and determination of eleven low-molecular-mass (LMW) organic acids (i.e. oxalic, lactic, malonic, maleic, citric, tartaric, adipic, glutaric, gluconic, isosaccharinic and succinic acid) in different sample matrices. This CZE method was adapted to suit MS conditions. Sheath liquid, sheath flow and MS parameters were optimized to achieve high mass spectrometric sensitivity. The CZE-ESI-MS procedure showed good sensitivity (limit of detection of < 0.05-0.7 mg/l for all acids), linearity (r2 = 0.9925-0.9998) and reproducibility (2.09-5.34% RSD). The applicability of the CZE-ESI-MS was demonstrated on LMW organic acids in an ale sample. In addition the (here presented) method also provided quantification of fumaric, galacturonic and 2-ketoglutaric acid with high sensitivity.  相似文献   

13.
A highly sensitive reversed‐phase liquid chromatographic (HPLC) method was investigated to analyze a range of positron emission tomography (PET) radiopharmaceuticals using electrogenerated chemiluminescence (ECL) detection. ECL is based on the reaction of PET molecules with tris(2,2′‐bipyridyl)ruthenium(III) [Ru(bpy)33+], which is generated through the on‐line electro‐oxidation of Ru(bpy)32+. In 21 different radiopharmaceuticals studied, 18 compounds could be detected with detection limits (signal‐to‐noise ratio = 3) of 0.12–72 ng/mL per 20 μL injection. Sufficient reproducibility and linearity were obtained for the quantitative determination of PET molecules in pharmaceutical fluid. This method could be successfully applied to quality control tests of PET radiopharmaceuticals with ultra‐high specific radioactivity. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
A liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory method for the simultaneous determination of nine corticosteroids in liver, including the four MRL compounds listed in Council Regulation 37/2010, was developed. After an enzymatic deconjugation and a solvent extraction of the liver tissue, the resulting solution was cleaned up through an SPE Oasis HLB cartridge. The analytes were then detected by liquid chromatography-negative-ion electrospray tandem mass spectrometry, using deuterium-labelled internal standards. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results showed that the method was suitable for statutory residue testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. All the corticosteroids can be detected at a concentration around 1 μg kg(-1); the recoveries were above 62% for all the analytes. Repeatability and reproducibility (within-laboratory reproducibility) for all the analytes were below 7.65% and 15.5%, respectively.  相似文献   

15.
A boron‐doped diamond (BDD) electrode coupled to flow injection analysis (FIA) was firstly developed for determination of N‐acetyl‐L ‐cysteine (NAC) in drug formulations. The effects of experimental parameters including pH, applied potential and scan rate on the response were investigated. FIA amperometry was applied as an automatic method for the quantitative detection of trace amounts of NAC. A wide linear range of 0.5–50 µmol/L and a low detection limit of 10 nmol/L were obtained. The results of amperometric determinations show a very good reproducibility, and the RSD for the measurement based on 10 measurements was <3.7 % and <4.1 % for intra‐ and inter‐day, respectively. The benefits of the proposed method are fast, simple, sensitive and no requirement of complicated operational steps.  相似文献   

16.
A novel fast high-performance liquid chromatography (HPLC) method coupled with diode array detection (DAD) and time-of-flight mass spectrometry (TOF/MS) was developed for qualitative and quantitative analysis of Radix Astragali products. The potential of fast HPLC on 1.8-microm particles was compared with the performance of HPLC on conventional 5-microm particles columns. Significant advantages of fast HPLC include high-speed chromatographic separation, four times faster than HPLC with conventional columns, and great enhancement in sensitivity with limits of detection low to 0.001 ng. With dynamic adjustment of fragmentor voltage in TOF/MS, an efficient transmission of the ions was achieved to obtain the best sensitivity and abundant fragmentation. By accurate mass measurements within 5 ppm error for each molecular ion and subsequent fragment ions, a reliable identification and differentiation of six major saponins including two groups of isomers and twelve main isoflavonoids was described here for the first time. For quantitative analysis by fast HPLC-TOF/MS, linearity of response over two orders of magnitude was demonstrated (r(2)>0.99) for all analytes. Intra-day reproducibility was below 3% RSD and inter-day values were below 5% RSD. A good correlation (slope=1.1108, r(2)=0.9853) was observed for accuracy test. It is concluded that the fast and sensitive HPLC-DAD-TOF/MS is powerful in qualitative and quantitative analysis of complex herbal medicines in terms of time savings, sensitivity, selectivity, precision, accuracy as well as increasing sample throughout and lowering solvent consumption.  相似文献   

17.
A sensitive, accurate and precise liquid chromatography/tandem mass spectrometry (LC/MS(2)) method was developed for the quantification of salmeterol in the urine of horses. The method consists of a liquid-liquid extraction with tert-butylmethyl ether and isopropanol at pH 12 after enzymatic hydrolysis. The extracts are analysed using an LC/MS system equipped with an electrospray ionisation (ESI) probe. Method validation showed excellent linearity, specificity, accuracy, precision and intra-laboratory repeatability and reproducibility. The limit of quantitative detection was 0.25 ng/mL and the limit of detection was 0.125 ng/mL. The excretion profile was determined after administration of 500 microg salmeterol (Serevent) to four standard-bred mares via a metered dose inhaler (MDI) with an Equinehaler adapter. Salmeterol was detected from 1 h until 12 h post-administration. Maximum urinary concentrations varied between 2.3 and 14.9 ng/mL.  相似文献   

18.
Tsikas D  Sandmann J  Beckmann B 《The Analyst》2011,136(2):407-10; discussion 411
Recently, Shen et al. (Analyst, 2010, 135, 302) reported on a flow injection analysis (FIA) ESI-MS/MS approach for the determination of the short-lived gaseous nitric oxide (NO) in biological samples. This method is based on the reaction of NO, and presumably of other NO-derived oxides such as N(2)O(3), with the vicinal amino groups of methylpiperazinobenzendiamine to form a benzotriazole derivative. Under MS/MS conditions, the protonated derivative loses molecular nitrogen (N(2)) from the triazole ring and the product ion formed is utilized for quantitative analyses. This seems to be the first ESI-MS/MS method for authentic NO detection and quantification. However, the ESI-MS/MS method reported by Shen et al. deserves some critical discussion.  相似文献   

19.
A comparison of two methods for the identification and determination of peanut allergens based on europium (Eu)-tagged inductively coupled plasma mass spectrometry (ICP-MS) immunoassay and on liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) with a triple quadrupole mass analyzer was carried out on a complex food matrix like a chocolate rice crispy-based snack. The LC/MS/MS method was based on the determination of four different peptide biomarkers selective for the Ara h2 and Ara h3/4 peanut proteins. The performance of this method was compared with that of a non-competitive sandwich enzyme-linked immunosorbent assay (ELISA) method with ICP-MS detection of the metal used to tag the antibody for the quantitative peanut protein analysis in food. The limit of detection (LOD) and quantitation of the ICP-MS immunoassay were 2.2 and 5 microg peanuts g(-1) matrix, respectively, the recovery ranged from 86 +/- 18% to 110 +/- 4% and linearity was proved in the 5-50 microg g(-1) range. The LC/MS/MS method allowed us to obtain LODs of 1 and 5 microg protein g(-1) matrix for Ara h3/4 and Ara h2, respectively, thus obtaining significantly higher values with respect to the ELISA ICP-MS method, taking into account the different expression for concentrations. Linearity was established in the 10-200 microg g(-1) range of peanut proteins in the food matrix investigated and good precision (RSD <10%) was demonstrated. Both the two approaches, used for screening or confirmative purposes, showed the power of mass spectrometry when used as a very selective detector in difficult matrices even if some limitations still exist, i.e. matrix suppression in the LC/ESI-MS/MS procedure and the change of the Ag/Ab binding with matrix in the ICP-MS method.  相似文献   

20.
Protein N-Glycan analysis is traditionally performed by high pH anion exchange chromatography (HPAEC), reversed phase liquid chromatography (RPLC), or hydrophilic interaction liquid chromatography (HILIC) on fluorescence-labeled glycans enzymatically released from the glycoprotein. These methods require time-consuming sample preparations and do not provide site-specific glycosylation information. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) peptide mapping is frequently used for protein structural characterization and, as a bonus, can potentially provide glycan profile on each individual glycosylation site. In this work, a recently developed glycopeptide fragmentation model was used for automated identification, based on their MS/MS, of N-glycopeptides from proteolytic digestion of monoclonal antibodies (mAbs). Experimental conditions were optimized to achieve accurate profiling of glycoforms. Glycan profiles obtained from LC-MS/MS peptide mapping were compared with those obtained from HPAEC, RPLC, and HILIC analyses of released glycans for several mAb molecules. Accuracy, reproducibility, and linearity of the LC-MS/MS peptide mapping method for glycan profiling were evaluated. The LC-MS/MS peptide mapping method with fully automated data analysis requires less sample preparation, provides site-specific information, and may serve as an alternative method for routine profiling of N-glycans on immunoglobulins as well as other glycoproteins with simple N-glycans.
Figure
?  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号