首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Robert Piech 《Electroanalysis》2009,21(16):1842-1847
A new adsorptive stripping voltammetric method for the determination of trace gallium(III) based on the adsorption of gallium(III)‐catechol complex on the cyclic renewable mercury film silver based electrode (Hg(Ag)FE) is presented. The effects of various factors such as: preconcentration potential and time, pulse height, step potential and supporting electrolyte composition are optimized. The calibration graph is linear from 2 nM (0.14 μg L?1) to 100 nM (6.97 μg L?1) for a preconcentration time of 30 s, with correlation coefficient of 0.9993. For a Hg(Ag)FE with a surface area of 9.7 mm2 the detection limit for a preconcentration time of 90 s is as low as 7 ng L?1. The repeatability of the method at a concentration level of the analyte as low as 0.05 μg L?1, expressed as RSD is 3.6% (n=5). The proposed method was successfully applied by studying the natural samples and simultaneous recovery of Ga(III) from spiked water and sediment samples.  相似文献   

2.
Preconcentration is achieved by adsorption of a palladium-dimethylglyoxime complex on a hanging mercury drop electrode. Optimal conditions area stirred acetate buffer solution (pH 5.15) containing 2 × 10?4 M dimethylglyoxime and an accumulation potential of —0.20 V. The height of the stripping peak in a negative-going linear scan is linearly dependent on palladium concentration and preconcentration time (over the ranges 0–16 μg l?1 and 0–300 s, respectively). For a 10-min preconcentration time, the detection limit is 20 ng l?1 (2.1 × 10?10 M). Possible interferences by other trace metals are investigated. Palladium added to seawater samples was easily quantified.  相似文献   

3.
《Electroanalysis》2006,18(24):2486-2489
This paper presents the enhanced analysis of copper on a bismuth electrode upon addition of gallium(III). The presence of gallium alleviates the problems of overlapping stripping signals usually observed between copper and bismuth when using the Bismuth Film Electrode. In addition, it has been found that the presence of gallium improves the reproducibility of the bismuth stripping signal. Simultaneous deposition of copper and bismuth at ?1500 mV for 2 minutes in a supporting electrolyte composed of 0.1 M pH 4.75 acetate buffer with 250 μg L?1 gallium yields well resolved copper and bismuth signals when analyzed with square‐wave anodic stripping voltammetry. Simultaneous analysis of copper and lead yielded linear calibration plots in the range 10 to 100 μg L?1 with regression coefficients of 0.997 and 0.994 respectively. The theoretical detection limit for copper was calculated to be 4.98 μg L?1 utilizing a 2 minutes deposition time. The relative standard deviation for a copper concentration of 50 μg L?1 was 1.6% (n=10).  相似文献   

4.
Simple cyclic renewable silver amalgam film electrode (Hg(Ag)FE), applied for the determination of gallium(III) using differential pulse anodic stripping voltammetry (DP ASV), is presented. The effects of various factors such as: preconcentration potential and time, pulse height, step potential and supporting electrolyte composition are optimised. The calibration graph is linear from 5?nM (0.35?µg?L?1) to 80?nM (5.6?µg?L?1) for a preconcentration time of 60?s, with correlation coefficient of 0.995. For a Hg(Ag)FE with a surface area of 9.9?mm2 the detection limit for a preconcentration time of 120?s is as low as 0.1?µg?L?1. The repeatability of the method at a concentration level of the analyte as low as 3.5?µg?L?1, expressed as RSD is 3.2% (n?=?5). The proposed method was successfully applied by studying the synthetic samples and simultaneously recovery of Ga(III) from spiked aluminium samples.  相似文献   

5.
A carbon paste electrode modified with 2‐aminothiazole functionalized poly(glycidylmethacrylate‐methylmethacrylate‐divinylbenzene) microspheres was used for trace determination of mercury, copper and lead ions. After the open‐circuit accumulation of the heavy metal ions onto the electrode, the sensitive anodic stripping peaks were obtained by square wave anodic stripping voltammetry (SWASV)). Many parameters such as the composition of the paste, pH, preconcentration time, effective potential scan rate and stirring rate influence the response of the measurement. The procedures were optimized for most sensitive and reliable determinations of the desired species. For a 10‐min preconcentration time in synthetic solutions at optimum instrumental and experimental conditions, the detection limit (LOD) was 12.3, 2.8 and 4.5 μg L?1 for mercury, copper and lead, respectively. The limits of detection may be enhanced by increasing the preconcentration time. For example, LOD of mercury and copper was 4.9 and 1.0 μg L?1 for fifteen minutes preconcentration time. The sensitivity may also considered to be increased by using a more suitable electrode composition targeting the more conductive electrode with lesser amount of modified polymer for sub‐μg L?1 levels of heavy metal ions. The optimized method was successfully applied to the determination of copper in tap water and waste water samples by means of standard addition procedure. The copper content found was comparable with the certified concentration of the waste water sample. The calibration plots for mercury and lead spiked real samples were also drawn.  相似文献   

6.
A simple voltammetric method is described for the determination of traces of selenium in gallium arsenide. Differential-pulse cathodic stripping voltammetry permits a direct determination of selenium without preliminary enrichment or separation processes. Selenium can be determined down to levels of 1–2 μg g?1, with relative standard deviations of about 10%, in ? 100-mg samples of gallium arsenide. Results for gallium arsenide doped with 7–75 μg g?1 selenium agree in most cases with those obtained by spectrophotometry based on 4-chloro-o-phenylenediamine.  相似文献   

7.
The fluoroquinolone antibacterial agent ofloxacin was studied by adsorptive stripping voltammetry. Controlled interfecial accumulation of ofloxacin on a static mercury drop electrode in the hanging mercury drop mode provides high sensitivity. The linear concentration range was 0.079–197.5 μg ml?1 when using a 60-s preconcentration at ?1 V vs. Ag/AgCl in Britton-Robinson buffer of pH 6.00. The detection limit of ofloxacin was 1 ng ml?1. The precision is excellent with a relative standard deviation of ca. 0.75% at a concentration of 0.848 μg ml?1.  相似文献   

8.
Robert Piech 《Electroanalysis》2008,20(22):2475-2481
The new cyclic renewable mercury film silver based electrode (Hg(Ag)FE), applied for the determination of selenium(IV) traces in the presence of copper ions using differential pulse cathodic stripping voltammetry (DP CSV) is presented. The preparation of the Hg(Ag)FE is very simple. The effects of various factors such as: preconcentration potential and time, pulse height, step potential and supporting electrolyte composition are optimized. The calibration graph is linear from 0.5 nM (39 ng L?1) to 100 nM (7.9 μg L?1) for a preconcentration time of 45 s, with correlation coefficient of 0.9995. For a Hg(Ag)FE with a surface area of 8 mm2 the detection limit for a preconcentration time of 90 s is as low as 17 ng L?1. The repeatability of the method at a concentration level of the analyte as low as 2 μg L?1, expressed as RSD is 2.7% (n=7). The proposed method was successfully applied and validated by studying the certified reference material (bovine liver BCR‐185) and simultaneously recovery of Se(IV) from spiked water samples.  相似文献   

9.
《Electroanalysis》2004,16(23):1977-1983
2,2‐bis(3‐Amino‐4‐hydroxyphenyl)hexafluoropropane (BAHHFP) was electro‐polymerized oxidatively on glassy carbon by cyclic voltammetry. The activity of the modified electrode towards ascorbic acid (AA), uric acid (UA) and dopamine (DA) was characterized with cyclic voltammetry and differential puls voltammetry (DPV). The findings showed that the electrode modification drastically suppresses the response of AA and shifts it towards more negative potentials. Simultaneously an enhancement of reaction reversibility is seen for DA and UA. Unusual, selective preconcentration features are observed for DA when the polymer‐modified electrode is polarized at negative potential. In a ternary mixture containing the three analytes studied, three baseline resolved peaks are observed in DPV mode. At physiological pH 7.4, after 5 min preconcentration at ?300 mV, peaks positions were ?0.073, 0.131 and 0.280 V (vs. Ag/AgCl) for AA, DA and UA, respectively. Relative selectivities DA/AA and UA/AA were over 4000 : 1 and 700 : 1, respectively. DA response was linear in the range 0.05–3 μM with sensitivity of 138 μA μM?1 cm?2 and detection limit (3σ) of 5 nM. Sensitive quantification of UA was possible in acidic solution (pH 1.8). Under such conditions a very sharp peak appeared at 630 mV (DPV). The response was linear in the range 0.5–100 μM with sensitivity of 4.67 μA μM?1 cm?2 and detection limit (3σ) of 0.1 μM. Practical utility was illustrated by selective determination of UA in human urine.  相似文献   

10.
A novel electrochemical stripping approach for the trace measurement of manganese is presented. The metal chelate with erichrome black T is adsorbed on a hanging mercury drop electrode, and the subsequent reduction current of the accumulated chelate is measured by voltammetry. Adsorptive preconcentration for 5 min results in a detection limit of 6 × 10?10 M (32 l?1). Cyclic voltammetry is used to characterize the redox and interfacial processes. Optimal experimental conditions include a 0.02 M piperazine-N,N′-bis(2-ethanesulfonic acid) solution (pH 12) containing 1 × 10?6 M eriochrome black T, a preconcentration potential of ?0.80 V, and a linear potential scan. The response is linear up to 2.9 × 10?7 M, and the relative standard deviation at 1.8 × 10?7 M is 1.5%. The effects of possible interferences from metal ions or organic surfactants are evaluated.  相似文献   

11.
The utility of glassy carbon electrodes coated with cellulose acetate for adsorptive stripping voltammetry of oxidizable organic compounds is evaluated. This surface modification alleviates the co-adsorption problem commonly encountered at conventional electrodes. Interferences from electro-inactive surfactants and, in certain situations, from adsorbable electroactive substances, are minimized. Quantitation of the drugs, chlorpromazine and trimipramine, is not affected by the presence of up to 120 mg 1?1 albumin or gelatin. The chlorpromazine response is not affected by the bilirubin or perphenazine peaks which overlap at uncoated electrodes. The adsorptive stripping response at the coated electrode is evaluated with respect to hydrolysis time, preconcentration time, concentration dependence, reproducibility, and other variables. The detection limit for chlorpromazine is 1.3 × 10?8 M (5-min preconcentration). Applicability to assays of urine and serum samples is illustrated.  相似文献   

12.
A rotating mercury-plated reticulated vitreous carbon (RVC) electrode is tested for square-wave anodic stripping voltammetry; RVC provides very large surface areas which are easily plated with mercury. Despite the ill-defined geometry of the electrode, the square-wave stripping peaks are very well defined; their behaviour conforms partly to known theory for square-wave stripping from mercury film electrodes. Fast analytical determinations of lead and cadmium in the μg l?1 range are facilitated by the high efficiency of the preconcentration step and the high sensitivity given by the stripping waveform.  相似文献   

13.
Catechol compounds are quantified by controlled adsorptive accumulation of their metal complexes onto a hanging mercury drop electrode followed by stripping voltammetry. By using tin(IV) as a redox marker for quantifying the surface-bound species, selectivity can be improved relative to conventional oxidative methods; dopamine can be quantified in the presence of ascorbic acid. The method allows measurements of micromolar levels of catechol, dopamine, l-dopa, 3,4-dihydroxyphenylacetic acid and caffeic acid. The adsorptive stripping response is evaluated with respect to preconcentration time and potential, tin(IV) and analyte concentrations, stripping mode, reproducibility and possible interferences. Analogously, solochrome violet RS and dimethylglyoxime can be quantified after accumulation of their iron(III) and nickel(II) complexes, respectively. Detection limits are 7×10?9 M for solochrome violet RS and 5×10?8 M for caffeic acid (1- and 5-min preconcentration, respectively).  相似文献   

14.
Chemically modified carbon paste eletrodes are prepared by incorporating appropriate quantities of a cation-exchange resin directly into the paste mixture. Ionic analytes can be preconcentrated on these electrodes by an ion-exchange reaction rather than electrolytic plating. Differential pulse voltammetry is used to quantify the accumulated ions. The response is characterized with respect to preconcentration period, bulk concentration, pH, paste composition, reproducibility, and other variables. Copper ion is used as a test system. The procedure exhibits good linearity for 6.25 × 10?5?3.0 × 10?4 M copper(II) ions and the peak current varies linearly with preconcentration time between 1 and 7 min for the conditions used.  相似文献   

15.
An electrochemical method for the determination of carbaryl, after prior oxidation to 1,4-naphthoquinone in natural water and soils is reported. The coulometric oxidation of carbaryl at a platinum electrode was studied using 0.024 mol/L Britton-Robinson buffer (pH 7.0). The reduction of the oxidation product 1,4-naphthoquinone at a dropping mercury electrode was used for the indirect determination of carbaryl after separation on C18 Sep-pak cartridges by differential pulse polarography (detection limits: 0.41 mg L?1 of water and 0.47 mg kg?1 of soil) and directly without separation by adsorptive stripping voltammetry (detection limits: 5 μg L?1 of water and 7 μg kg?1 of soil, for 75 s preconcentration time). Relative errors were lower than 3.7% and relative standard deviations smaller than 4.5%.  相似文献   

16.
Robert Piech 《Electroanalysis》2010,22(16):1851-1856
A new adsorptive stripping voltammetric method for the determination of trace scandium(III) based on the adsorption of scandium(III)‐mordant blue 9 complex on the cyclic renewable mercury film silver based electrode (Hg(Ag)FE) is presented. The effects of various factors such as: preconcentration potential and time, pulse height, step potential and supporting electrolyte composition are optimized. The calibration graph is linear from 2 nM (0.09 μg L?1) to 90 nM (4 μg L?1) for a preconcentration time of 45 s, with correlation coefficient of 0.9995. For a Hg(Ag)FE with a surface area of 7.9 mm2 the detection limit for a preconcentration time of 90 s is as low as 5 ng L?1. The repeatability of the method at a concentration level of the analyte as low as 0.2 μg L?1, expressed as RSD is 1.9 % (n=5). The proposed method was successfully applied and validated by studying the certified reference material (CRM 320 – river sediment) and natural samples with simultaneous recovery of Sc(III) from spiked water and sediment samples.  相似文献   

17.
《Electroanalysis》2005,17(4):343-347
The adsorptive voltammetric behavior of the gallium‐alizarin red S (ARS) complex in NH4OAc‐HCl buffer at a carbon paste electrode(CPE) was investigated. The results showed that the complex can be adsorbed on the surface of the CPE, yielding one reduction peak at ?0.52 V(vs. SCE), corresponding to the irreversible reduction of the ligand, ARS, bonded in the complex. The optimal experimental conditions include the use of 0.10 mol L?1 ammonium acetate buffer(pH 4.5), 1.0×10?5 mol L?1 ARS, an accumulation potential of ?0.05 V, an accumulation time of 180 s ,a rest time of 10 s, a scan rate of 200 mV s?1and a second‐order derivative linear scan mode. The peak current is proportional to the concentration of gallium(III) over the range 0.02–6.0 μg L?1, with the detection limit of 0.01 μg L?1 for an accumulation time of 180 s. The method was applied to the determination of gallium in food samples with satisfactory results.  相似文献   

18.
《Electroanalysis》2006,18(3):223-230
This work reports the use of adsorptive stripping voltammetry (AdSV) for the determination of uranium on a preplated rotating‐disk bismuth‐film electrode (BiFE). The principle of the method relied on the complexation of U(VI) ions with cupferron and the subsequent adsorptive accumulation of the complex on the surface of the BiFE. The uranium in the accumulated complex was then reduced by means of a cathodic voltammetric scan while the analytically useful U(VI)→U(V) reduction signal was monitored. The experimental variables as well as potential interferences were investigated and the figures of merit of the method were established. Using the selected conditions, the 3σ limit of detection for uranium was 0.1 μg L?1 at a preconcentration time of 480 s and the relative standard deviation was 4.7% at the 5 μg L?1 level for a preconcentration time of 120 s (n=8). The accuracy of the method was established by analyzing a reference sea water sample.  相似文献   

19.
Electrochemical behavior of remarkably low levels of Ribonucleic acid yeast (yRNA) is studied through differential pulse voltammetry (DPV), and kinetic parameters of the electrochemical reaction have also been calculated through square‐wave voltammetry (SWV), based on immobilization of yRNA on the surface of a CPB‐cellulose modified electrode. YRNA/ CPB‐cellulose/ITO conductive glass electrode is demonstrated by Infrared reflect (IR) and electrochemical impedance spectroscopy (EIS). The oxidation peak potential of yRNA shifts negatively with increasing pH. The peak currents decrease gradually in successive scans and no corresponding reduction peaks occur, indicating that oxidation process of yRNA is completely irreversible. Variables influencing DPV response of yRNA, such as pH, pulse amplitude and electrolyte concentration, are explored and optimized. Peak currents are proportional to the concentration of yRNA in the range of 0.1 μg mL?1–1.0 μg mL?1, and the linear regression coefficient equals 0.9923. The detection limit for yRNA is 1.0×10?10 g mL?1. Interferences of L ‐cysteine, L ‐alanine, Hemoglobin, Uridine 5′‐monophosphate, Guanosine 5′‐monophosphate, Adenosine 5′‐triphosphate and some metal ions (Co3+, Cr3+, Ni2+, Hg2+, Zn2+, etc) are negligible. The methods adopted here are more sensitive and selective than currently applied techniques and overcome the drawback of absorption spectroscopy arising from a strong interference due to other UV‐absorbing substances.  相似文献   

20.
Selenium(IV), in the concentration range 2–100 μg l?1 in contaminated waters, is determined by using the sensitive adsorption-controlled peak obtained by differential pulse polarography in dilute acid solution. Interfering heavy metals are removed on Chelex-100 resin. Selenium(VI) is not electroactive but can be determined after photolytic reduction in the absence of oxygen. Anion-exchange preconcentration is necessary if the total selenium is below the detection limit of 2 μg l?1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号