首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Automated methods of PDMS/β‐CD/divinylbenzene‐coated stir plate sorptive extraction (SPSE) coupled to HPLC‐fluorescence detector were reported for the first time. Three automation modes, static SPSE, circular flow SPSE and continuous flow SPSE, were evaluated and critically compared with stir bar sorptive extraction by using six polycyclic aromatic hydrocarbons as model analytes. It was found that the operable sample volume for circular flow SPSE and continuous flow SPSE was larger than that for static SPSE. Under the same extraction conditions, continuous flow SPSE exhibited the highest extraction efficiencies in all automated modes and manual stir bar sorptive extraction for the target compounds. Compared with the manual operation (approximately 5–10 min), automated SPSE required a relatively short time (117–180 s) to finish sampling, washing and sample loading. Besides being labor‐saving and time‐saving, automated SPSE has other advantages, such as no time limit and non‐attended operation. The proposed continuous flow PDMS/β‐CD/divinylbenzene‐coated SPSE‐HPLC‐fluorescence detector was successfully applied to environmental water analysis.  相似文献   

2.
In this article, homogeneous liquid–liquid extraction (HOLLE), combined with HPLC-fluorescence detector (HPLC-FLD), has been developed for the extraction and determination of polycyclic aromatic hydrocarbons (PAHs) in vegetables. ACN was used as extraction solvent for the extraction of target analytes from vegetables. When the previous extraction process was over, the ACN extract was transferred to the water-immiscible organic phase, tetrachloroethane, used as extraction solvent in HOLLE procedures. Under the optimum conditions, repeatability was carried out by spiking PAHs at concentration level of 12.5 μg/kg, the RSDs varied between 1.1 and 8.5% (n = 3). The LODs, based on S/N of 3, ranged from 0.025 to 0.25 μg/kg. Relative recoveries of PAHs from cucumber and long crooked squash samples were in the range of 72.4–104.9% and 65.5–119.3%, respectively. Compared with the conventional extraction method, the proposed method has the advantage of being quick, easy to operate, and having low consumption of organic solvent.  相似文献   

3.
A continuous-flow extraction system coupled on-line with a high-performance liquid chromatograph with an ultraviolet detector is used to study the extraction of three organophosphorus pesticides (fenthion, azinphos methyl and diazinon) from aqueous samples with n-heptane as the organic solvent. Diazinon was not extracted significantly. The influence on the extraction of different parameters (coil length, flow rate and phase volume ratio) were studied. The calibration graphs are linear for 0.5–7 mg l?1 and 8–20 mg l?1 foor azinphos methyl where the percentage extraction (E%) is 90% and 70%, respectively, and up to 4 mg l?1 for fenthion, where the E% is 33%. The detection limits and the relative standard deviations are 0.04 and 0.09 mg l?1, and 3.4 and 5.3%, for azinphos methyl fenthion, respectively. Other pesticides and related compounds were found not to interfere. The sample throughput of this method was 15 h?1.  相似文献   

4.
For the first time a dispersive liquid–liquid microextraction method on the basis of an extraction solvent lighter than water was presented in this study. Three organophosphorus pesticides (OPPs) were selected as model compounds and the proposed method was carried out for their preconcentration from water samples. In this extraction method, a mixture of cyclohexane (extraction solvent) and acetone (disperser) is rapidly injected into the aqueous sample in a special vessel (see experimental section) by syringe. Thereby, a cloudy solution is formed. In this step, the OPPs are extracted into the fine droplets of cyclohexane dispersed into aqueous phase. After centrifuging the fine droplets of cyclohexane are collected on the upper of the extraction vessel. The upper phase (0.40 μL) is injected into the gas chromatograph (GC) for separation. Analytes were detected by a flame ionization detector (FID) (for high concentrations) or MS (for low concentrations). Some important parameters, such as the kind of extraction and dispersive solvents and volume of them, extraction time, temperature, and salt amount were investigated. Under the optimum conditions, the enrichment factors (EFs) ranged from 100 to 150 and extraction recoveries varied between 68 and 105%, both of which are relatively high over those of published methods. The linear ranges were wide (10–100 000 μg/L for GC‐FID and 0.01–1 μg/L for GC‐MS) and LODs were low (3–4 μg/L for GC‐FID and 0.003 μg/L for GC‐MS). The RSDs for 100.0 μg/L of each OPP in water were in the range of 5.3–7.8% (n = 5).  相似文献   

5.
A simple technique for the collection of an extraction solvent lighter than water after dispersive liquid–liquid microextraction combined with high‐performance liquid chromatography with ultraviolet detection was developed for the determination of four paraben preservatives in aqueous samples. After the extraction procedure, low‐density organic solvent together with some little aqueous phase was separated by using a disposable glass Pasteur pipette. Next, the flow of the aqueous phase was stopped by successive dipping the capillary tip of the pipette into anhydrous Na2SO4. The upper organic layer was then removed simply with a microsyringe and injected into the high‐performance liquid chromatography system. Experimental parameters that affect the extraction efficiency were investigated and optimized. Under optimal extraction conditions, the extraction recoveries ranged from 25 to 86%. Good linearity with coefficients with the square of correlation coefficients ranging from 0.9984 to 0.9998 was observed in the concentration range of 0.001–0.5 μg/mL. The relative standard deviations ranged from 4.1 to 9.3% (n = 5) for all compounds. The limits of detection ranged from 0.021 to 0.046 ng/mL. The method was successfully applied for the determination of parabens in tap water and fruit juice samples and good recoveries (61–108%) were achieved for spiked samples.  相似文献   

6.
Liu JF  Liang X  Jiang GB  Cai YQ  Zhou QX  Liu GG 《Talanta》2003,60(6):1155-1161
An on-line coupled continuous flow liquid membrane extraction (CFLME) and C18 precolumn system was developed for sample preconcentration in liquid chromatography determination. After preconcentration by CFLME, which is based on the combination of continuous flow liquid–liquid extraction and supported liquid membrane, bisphenol A (BPA) was enriched in 960 μl of 1 mol l−1 NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto a C18 analytical column for separation and detected at 220 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor, and enrichment time were optimized. The proposed method presents a detection limit of 0.03 μg l−1 (S/N=3) when 60 ml samples was enriched with an enrichment time of 30 min. Compared with C18 based column-switching procedure, this proposed procedure presents similar sample throughput and lower detection limits. The proposed method was successfully applied to determine BPA in tap water, river water, and municipal sewage effluent samples.  相似文献   

7.
Supercritical fluid extraction was coupled directly with high performance liquid chromatograph. The system was evaluated for direct injection of supercritical CO2 and modified supercritical CO2 at high pressure and temperature onto a HPLC system with varying mobile phase compositions and flow rates. Injection of 9 μL supercritical CO2 onto the HPLC using methanol/water mobile phases from 100% methanol to 80% with a flow of 1.0 mL/min did not adversely affect the baseline of UV detector. However at higher percentages of water, CO2 solubility in the mobile phase decreased and caused baseline interferences on the UV detector. At higher HPLC mobile phase flow rates, supercritical CO2 was injected to higher percentages of water without any effect on the UV baseline. Also, increasing the extraction pressure or modifier concentration did not change the results. Separations of polynuclear aromatic hydrocarbons and linear alkenebenzene sulfonate test mixtures were obtained using on-line SFE/HPLC interfaced system.  相似文献   

8.
Sun M  Du WB  Fang Q 《Talanta》2006,70(2):392-396
In this work, a miniaturized liquid-liquid extraction system under stopped-flow manipulation mode with spectrometric detection was developed. A Teflon AF liquid-core waveguide (LCW) capillary was used to serve as both extraction channel for organic solvent flow and adsorption detection flow cell. Gravity induced hydrostatic pressure was used to drive the organic and aqueous phases through the extraction channels. During extraction process, a stable organic and aqueous phase interface was formed at the outlet of the capillary, through which the analyte in the flowing aqueous stream was extracted into the stationary organic solvent in capillary. The absorbance of the analyte extracted into the organic solvent was measured in situ by a spectrometric detection system with light emitting diode (LED) as light source and photodiode as absorbance detector. The performance of the system was demonstrated in the determination of sodium dodecyl sulfate (SDS) extracted as an ion pair with methylene blue into chloroform. The precision of the measured absorbance for a 5 mg L−1 SDS standard was 6.1% R.S.D. (n = 5). A linear response range of 1-10 mg L−1 SDS was obtained with 5 min extraction period. The limit of detection (LOD) for SDS based on three times standard deviation of the blank response was 0.25 mg L−1.  相似文献   

9.
Stainless‐steel wires coated with mesoporous titanium oxide were placed into a polyether ether ketone tube for in‐tube solid‐phase microextraction, and the coating sorbent was characterized by X‐ray diffraction and scanning electron microscopy. It was combined with high‐performance liquid chromatography to build an online system. Using eight polycyclic aromatic hydrocarbons as the analytes, some conditions including sample flow rate, sample volume, organic solvent content, and desorption time were investigated. Under optimum conditions, an online analysis method was established and provided good linearity (0.03–30 μg/L), low detection limits (0.01–0.10 μg/L), and high enrichment factors (77.6–678). The method was applied to determine target analytes in river water and water sample of coal ash, and the recoveries are in the range of 80.6–106.6 and 80.9–103.5%, respectively. Compared with estrogens and plasticizers, extraction coating shows better extraction efficiency for polycyclic aromatic hydrocarbons.  相似文献   

10.
A simple, rapid and efficient ionic liquid based on dispersive liquid-phase microextraction (IL-DLPME) method was developed for the determination of three triazine and two phenylurea herbicides in water samples. IL (1-hexyl-3-methylimidazolium hexafluorophosphate [C6MIM][PF6]) that dispersed completely into the water solution under controlled temperature was used as the extraction solvent. The analytes were easily concentrated into the ionic liquid phase. This technique combined the process of extraction and concentration of the analytes into one step and avoided use of the more common, toxic organic solvents. The factors affecting the extraction efficiency such as the IL volume, sample pH, extraction time, centrifugal time, dissoluble temperature and ionic strength were optimized. The extracts were analyzed by high-performance liquid chromatography (HPLC) coupled with diode array detector (DAD). Under the optimized conditions, recoveries (50.5–109.1%) were obtained for the target analytes in water samples. The calibration curves were linear and the correlation coefficient ranged from 0.9947 to 0.9973 in the concentration levels of 5–100 μg L?1. The relative standard deviations (RSDs, n?=?5) were 6.80–10.78%. The limit of detections (LODs) for the five polar herbicides were between 0.46 μg L?1 and 0.89 μg L?1.  相似文献   

11.
逐级提取-高效液相色谱法快速测定植物组织中8种有机酸   总被引:2,自引:0,他引:2  
黄天志  王世杰  刘秀明  刘虹  吴沿友  罗绪强 《色谱》2014,32(12):1356-1361
针对植物组织中草酸存在的不同形态,建立了水和稀盐酸作为提取介质的逐级提取方法,获得了水溶态和酸溶态草酸及乙醇酸、乙醛酸、酒石酸、苹果酸、乙酸、柠檬酸、琥珀酸等有机酸。采用Hypersil ODS (200 mm×4.6 mm, 5 μm)色谱柱,以5 mmol/L磷酸二氢钾水溶液(pH 2.8)作为流动相,在进样量5 μL、检测波长210 nm、柱温30 ℃的条件下,通过分时段控制流速实现了8种有机酸的快速分离,同时去除了盐酸对酸溶态草酸测定的干扰。本方法精确灵敏、回收率高、重复性好,可应用于实际样品的测定分析。  相似文献   

12.
A new method for the determination of four sulfonylurea herbicides (metsulfuron-methyl, chlorsulfuron, bensulfuron-methyl and chlorimuron-ethyl) in water samples was developed by dispersive liquid–liquid microextraction coupled with high performance liquid chromatography-diode array detector. Parameters that affect the extraction efficiency, such as the kind and volume of the extraction and disperser solvent, extraction time and salt addition, were investigated and optimised. Under the optimum conditions, the enrichment factors were in the range between 102 and 216. The linearity of the method was obtained in the range of 1.0–100 ng mL?1 with the correlation coefficients (r) ranging from 0.9982 to 0.9995. The method detection limits were 0.2–0.3 ng mL?1. The proposed method has been successfully applied to the analysis of target sulfonylurea herbicides in river, stream and well water samples with satisfactory results.  相似文献   

13.
The range of application of a commercial thermodesorption-cryofocussing unit connected to a gas chromatograph/mass selective detector was extended to water analysis by using it in conjunction with membrane extraction. A flow of nitrogen passes through a silicone hollow fiber immersed in the water sample and extracted volatile organic compounds are enriched in a sorption tube mounted on top of the extraction cell. The sorption tube is then placed in the thermodesorption unit and analyzed by GC/MS. The optimal extraction parameters of this combined method were found to be 30 min extraction at 20°C with a stirring speed of 1,250 rpm and a flow rate of 100 mL/min nitrogen using a silicone hollow fiber of 0.3 m length. Under these conditions the reproducibility of the method was 5.2–10.5% RSD. The linear dynamic range of the optimized method spans three orders of magnitude and detection limits were found to be 0.02–0.1 μg/L for cis/trans-1,2-dichloroethene, benzene, trichloroethene, chlorobenzene, bromobenzene, ethylbenzene, 1,1,2,2-tetrachloroethane, and 1,2/1,4-dichlorobenzene. The method was found to be suitable for compounds with boiling points up to 220°C as memory effects increased considerably from dichloro- to hexachlorobenzene. Highly contaminated groundwater samples were analyzed. Quantitative results corresponded well with those achieved with conventional headspace-GC/FID.  相似文献   

14.
A continuous flow liquid membrane extraction (CFLME)-C18 precolumn-liquid chromatography system was developed for preconcentration and determination of chlorinated phenols (CPs). After preconcentration by CFLME, which is based on the combination of continuous flow liquid-liquid extraction and supported liquid membrane, CPs were enriched in 960 μl of 0.5 mol l−1 NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto the C18 analytical column for separation and detected at 215 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor concentration were optimized. The proposed method presents detection limits of 0.02-0.09 μg l−1 (S/N=3) when 100 ml samples were enriched. The proposed method was successfully applied to determine CPs in tap water and river water samples with spiked recoveries in the range of 70-121%.  相似文献   

15.
A method for the extraction and quantification by high performance liquid chromatography (HPLC) of non-labelled benzodiazepines partitioned into biological membranes has been developed. The benzodiazepine (BZD) was partitioned in a synaptosomal membrane-buffer system. The membranous pellet was separated by centrifugation and from this pellet, previously submitted or not to a proteolytic treatment and resuspended in the same buffer, the BZD was extracted by the addition of the proper volume of ethyl acetate, i.e. that capable of extracting at least 99.5% of the total drug in the aqueous phase. Optimal conditions for maximum proteolysis were: incubation of membranes at a final concentration of 1 mg protein/mL in the presence of 0.08 mg of Protease type I per mL for 90 min. at 45 degrees C. Although the efficiency of the proteolysis was demonstrated not only by kinetic but also by electrophoretic evidence, recovery of BZD in the organic solvent was not increased by the enzymatic treatment at a mass BZD/protein ratio in the range 4-4.6 10(-5) micrograms BZD/mg protein. For the HPLC quantification a reversed phase ODS column was used with methanol:water (1:1) plus 3.5% acetic acid as the mobile phase at a constant pressure and 1 mL/min flow rate. The UV detector was calibrated at 265 nm. Calibration curves were constructed by plotting peak height or peak area vs. nmoles BZD and adjusted to straight lines by a regression analysis by the least squares method. The peak height was selected as the detection method. Intra- and inter-assay precision did not exceed 10% and the total recovery was 100%.  相似文献   

16.
This article describes the preconcentration of methyl methacrylate in produced water by the dispersive liquid–liquid microextraction using extraction solvents lighter than water followed by gas chromatography. In the present experiments, 0.4 mL dispersive solvent (ethanol) containing 15.0 μL extraction solvent (toluene) was rapidly injected into the samples and followed by centrifuging and direct injection into the gas chromatograph equipped with flame ionization detector. The parameters affecting the extraction efficiency were evaluated and optimized including toluene (as extraction solvent), ethanol (as dispersive solvent), 15 μL and 0.4 mL (as the volume of extraction and dispersive solvents, respectively), pH 7, 20% ionic strength, and extraction's temperature and time of 20°C and 10 min, respectively. Under the optimum conditions, the figures of merits were determined to be LOD = 10 μg/L, dynamic range = 20–180 μg/L, RSD = 11% (n = 6). The maximum recovery under the optimized condition was determined to be 79.4%.  相似文献   

17.
In the system described, the two phases are fed into a module containing a PTFE membrane so that no segmentation takes place, i.e., each phase is fed to only on one dise of the membrane. The groove depth on the “aqueous” side of the membrane is 0.4 mm and on the “organic” side 0.8 mm. This latter groove is filled with a porous support of polyethylene. Caffeine, sodium dodecyl sulphate and sodium dioctylsulphosuccinate samples (40—500 μl) were injected into an aqueous carrier stream which was merged and mixed with an aqueous reagent before it was fed into the module. The maximum extraction efficiency varied with the flow rate but was in the range 8–18% and was obtained by injecting sample volumes larger than 400 μl. By injecting 40 μl of sample, the efficiency dropped by a factor of 1.5–7, depending on the character of the analyte. The system is suitable for coarse liquid-liquid extraction of concentrated samples because neither segmentation nor separation of the phases is required.  相似文献   

18.
The formation conditions and characteristics of a liquid/liquid optical waveguide (LLW) were studied using a two-phase sheath flow, where the inner organic phase flow acted as the core and the outer aqueous flow acted as the clad. In immiscible solvent systems, i.e., toluene/water and diethyl ether/water systems, the LLWs were formed in the range of higher than ca. 600 of the Reynolds number (Re), where the linear velocity of the organic solvent was much higher than that of the aqueous solution. On the other hand, in a miscible solvent system, i.e., a tetrahydrofuran/water system, a stable LLW was formed in the range of a much lower Re than in immiscible systems. Moreover, the molecules at the toluene/water interface of the LLW were observed with both fluorescence and absorbance measurement systems. In particular, the change in the fluorescence spectrum of 1-anilino-8-naphthalenesulfonate (ANS) at the interface within 1 ms was observed by this method, indicating the usefulness of the LLW for a fast kinetic study of a liquid/liquid interface.  相似文献   

19.
Pressurized liquid extraction (PLE) at room temperature with a laboratory-assembled system was applied for the extraction of gastrodin (GA) and vanillyl alcohol (VA) in Gastrodia elata Blume. The proposed system setup for this current work was simpler as no heating and backpressure regulator was required. Extraction with PLE was carried out dynamically at a flow rate of 1.5 mL/min, at room temperature, under an applied pressure of 10-20 bars with an extraction time of 40-50 min. The extraction efficiencies of the proposed method using 20% aqueous ethanol were compared with heating under reflux using organic solvents such as methanol and ethanol/water (20:80) for different batches of medicinal plant materials. For the determination of GA and VA in G. elata Blume, the extraction efficiencies of PLE at room temperature were observed to be comparable with heating under reflux. The method precision was found to vary from 1.6 to 8.6% (RSD, n = 6) on different days. The marker compounds present in the various medicinal plant extracts were determined by gradient elution HPLC and HPLC/MS/MS. Our work demonstrated the possibility of implementation of PLE at room temperature and the advantages of minimizing the use of organic solvents in the extraction process.  相似文献   

20.
Solid‐phase extraction coupled with dispersive liquid–liquid microextraction was developed as an ultra‐preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion‐methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid‐phase extraction coupled with dispersive liquid–liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid‐phase extraction coupled with dispersive liquid–liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9–6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号