首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
The stopped-flow reagent-injection method proposed for the spectrophotometric determination of fluoride with lanthanum (III)/alizarin fluorine blue in the presence of sodium dodecyl sulphate at pH 4.6 (λmax=574 nm) provides a linear calibration graph for 0.08–1.2 mg l?1 fluoride. The relative standard deviation (n=10) was 0.2% at 0.60 mg l?1 fluoride. The sampling rate was 60 h?1. The method is applied to sea and bottled mineral waters with satisfactory results.  相似文献   

2.
Optimum conditions for the adaptation of the spectrophotometric pyrocatechol violet method for aluminium to a flow-injection system are described. The detection limit is 3 μg Al l?1 and calibration graphs are linear up to 3 or 10 mg l?1 (with 200-μl or 10-μl injection loops, respectively). The relative standard deviation is 〈 2% at 0.1 mg Al l?1. Potential interferences of 40 common inorganic ions and of 20 organic substances, including fulvic acid, are reported. With the use of conventional masking agents and predigestion of samples with high organic content, the method is suitable for determining total aluminium in natural waters.  相似文献   

3.
A portable, automated spectrophotometric field monitor is described for the determination of total ammonia in river water. The linear calibration range (0–5000 μg NH3-N) and precision (0.7–2.1%; n=6) of the monitor were evaluated in the loaboratory. The monitor was designed to operate unattended for a minimum of one week, after which tme the reagent solutions (bromothymol blue and sodium hydroxide) and the standard solutions were renewed and the teflon gas-diffusion membrane replaced. Results are presented for a three-day field trial on the River Avon near Bristol.  相似文献   

4.
In this flow-injection method, the total concentration of calcium and magnesium is determined by using triethanolamine/hydrochloric acid buffer (pH 7.0) and chlorphosphonazo-III (CPA-III) in the flow streams, and the concentration of calcium alone is determined by using 1.6×10?3 M hydrochloric acid and CPA-III in the flow treams. At pH 7.0, medium, the linear calibration ranges were 0–2.00 mg l?1 for both calcium and magnesium and the detection limits were each 0.02 mg l?1; at pH 2.2, the linear calibration range for calcium and the detection limit were 0.20–2.00 mg l?1 and 0.1 mg l?1, respectively. Injection rates are 200 h. The method is suitable for analyzing natural waters.  相似文献   

5.
A spectrophotometric flow-injection procedure is described for the determination of sulphate in sodium hydroxide solutions. Sulphate catalyses the reaction between zirconium and methylthymol blue to form a complex measured at 586 nm. Optimal reaction conditions are discussed. The calibration graph is linear over the range 0.05–0.5 g l?1 sulphate with a relative standard deviation of 0.02. The sample throughput is 20 h?1. Sulphate is easily determined in 1 M sodium hydroxide; the results agree with those obtained by the conventional gravimetric method and by ion chromatography.  相似文献   

6.
A portable, automated, flow-injection-based solid-state spectrophotometric field monitor for the determination of residual dissolved aluminium in potable and treated waters is described. Aluminium is determined by complexation with pyrocatechol violet to form a colloidal lake with a maximum absorbance at 580 nm. Interference from iron(III) is masked by reduction to iron(II) and complexation with 1,10-phenanthroline. The monitor operates on a 30-min analytical cycle, i.e., with 48 results per day, and each cycle includes an autocalibration step. Over the course of a 3-month field trial the reliability was greater than 90%. The performance conforms to industry specifications for both overall accuracy (bias < ± 10%) and repeatability (relative standard deviation < ± 10%), the linear range is 0–1000 μg l?1 and the practical limit of detection is 45 μg l?1.  相似文献   

7.
A multi-pumping flow system for the spectrophotometric determination of nitrite and nitrate is described. The determination of nitrite is based on the Griess-Ilosvay reaction. Nitrate can be determined after its on-line reduction to nitrite using hydrazine sulphate in alkaline medium. Calibration was linear up to 3 mg NO2 L−1 with a limit of detection (3sb/S) of 0.013 mg NO2 L−1 an injection throughput of 55 injections h−1 and a repeatability (RSD) of 0.5% for the direct determination of nitrite. Two calibration graphs within the ranges 0.039–7 mg NO3 L−1 and 0.026–5 mg NO2 L−1 were run for the determination of nitrate and nitrite under reducing conditions, respectively. A limit of detection of 0.039 mg NO3 L−1 was obtained. An injection throughput of 27 injections h−1 and an RSD lower than 1.5% were achieved. The method was successfully applied to the determination of nitrite and nitrate in water samples. Correspondence: Víctor Cerdà, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa Km7.5, 07122 Palma de Mallorca, Spain  相似文献   

8.
The hydrogen peroxide produces in the oxidation of glucos in an immobilized glucose oxidase reactor is determined by using Bindschedler's green (leuco base) as color reagent with iron(II) as catalyst; the increase in the absorbance at 725 nm is measured. For 100-μl samples, calibration was almost linear in the range 0–2.5 mg l?1 glucose; the relative standard deviation for 1 mg l?1 glucose was 0.6% (n=10) and the detection limit (S/N= 2) was 0.02 mg l?1. The injection rate was 20 h?1. Glucose was determined satisfactorily in control sera and in real blood sera.  相似文献   

9.
《Analytical letters》2012,45(1-3):271-283
A flow injection system is proposed for catalytic kinetic spectrophotometric determination of trace iron(II + III). The involved reaction is based on the catalytic effect of iron(III) on oxidation reaction of xylenol orange by potassium bromate to form a blue-violet complex. Iron(II) is also determined, being oxidized to iron(III) by potassium bromate. The calibration graph is linear in the range of 0.02–10.0 µg l?1 and 10.0–1100 µg l?1. The relative standard deviation is 1.5% for 4.0 µg l?1 iron(III) and 2.3% for 60.0µg l?1 iron(III) (n = 11). The presented system was applied successfully to the determination of iron in natural waters.  相似文献   

10.
Sulphur dioxide can be determined at a sampling rate of 120 h?1, with amperometric detection after separation in a diffusion cell with a teflon membrane. At 25°C, the calibration graph shows two linear ranges, between 0.06 and 6 mg l?1 and 12 and 110 ml l? sulphur dioxide, with a detection limit of 0.03 mg l?1. At 50°C, the liner range is 04–5 mg l?1, with a detection limit of mg of l?1. The procedure has been applied to the determination of sulphur dioxide in wines.  相似文献   

11.
The salicylate method for determination of nitrate in drinking waters has been simplified by using the calibration solutions for 54 days, and therefore, reducing the work time. The results obtained can be considered satisfactory with regard to limit of determination (0.10 mg l−1 nitrate as nitrogen (NO3-N)), precision (relative standard deviations <4% for five determinations were found) and accuracy (recoveries from 88 to 106% for nitrate in spiked drinking water were obtained).  相似文献   

12.
Microwave plasma torch (MPT), traditionally used as the light source for atomic emission spectrophotometry, has been employed as the ambient ionization source for sensitive detection of uranium in various ground water samples with widely available ion trap mass spectrometer. In the full‐scan mass spectra obtained in the negative ion detection mode, uranium signal was featured by the uranyl nitrate complexes (e.g. [UO2(NO3)3]?), which yielded characteristic fragments in the tandem mass spectrometry experiments, allowing confident detection of trace uranium in water samples without sample pretreatment. Under the optimal experimental conditions, the calibration curves were linearly responded within the concentration levels ranged in 10–1000 µg·l?1, with the limit of detection (LOD) of 31.03 ng·l?1. The relative standard deviations (RSD) values were 2.1–5.8% for the given samples at 100 µg·l?1. The newly established method has been applied to direct detection of uranium in practical mine water samples, providing reasonable recoveries 90.94–112.36% for all the samples tested. The analysis of a single sample was completed within 30 s, showing a promising potential of the method for sensitive detection of trace uranium with improved throughput. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
《Analytical letters》2012,45(7):989-999
Abstract

A new method for flow-injection analysis (FIA) for the determination of penicillins based on the extraction and spectrophotometric determination of ion associates with selected thiazine dyes (methylene blue, azure A, and azure B) is proposed. The reaction conditions (cdye = 2 × 10?4 mol l?1, cKCl = 1 mol l?1, pH ? 6, λ = 635 nm) were found. The factorial design has been carried out to determine the optimum flow conditions. A wide linear dynamic range of calibration curves (5.1–700 µg ml?1 for penicillin V with all dyes, R = 0.9985) and good repeatability (e.g., relative standard deviation [RSD] = 4.6–0.6% in this concentration range for the reaction with azure B) were found. The detection limit for penicillin V is 1.5 µg ml?1, and the determination limit is 5.1 µg ml?1. The maximum analysis rate is 35 samples per h. The practical samples of pharmaceutics were tested. There are no interferences from the additives in pharmaceutics.  相似文献   

14.
《Analytical letters》2012,45(12):2323-2332
Abstract

A simple spectrophotometric method for the trace determination of nitrite (NO? 2) is described. Nitrite is reacted with Salbutamal sulphate in acidic medium which gives a yellow colour in alkaline medium (?pH 7) and can be determined in the presence of several cations and anions. Beer's law is obeyed in the range of 1.8 to 27.6 ppm of nitrite with the molar absorptivity 1.8 × 103 1 × mole?1 × cm?1 at 4l0 nm. The proposed method can also be utilized for the determination of nitrate (NO? 3) after its reduction to nitrite. The method has been applied for the determination of various samples containing traces of nitrite.  相似文献   

15.
The direct determination of uranium(VI) by a flow-injection procedure is based on spectrophotometric measurement with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol in the present of fluoride. The interfering effects of many commonly occuring elements were studied. The calibration curve was linear over the range 0.5–20 mg 1?1 uranium(VI). The relative standard deviation obtained on a leach liquor containing 10 mg 1?1 uranium(VI) was 1.9%. The procedure is rapid and convenient, and up to 40 samples can be analysed per hour.  相似文献   

16.
A simple and rapid method is proposed for the spectrofluorimetric determination of anionic surfactants. It is based on formation of an ion-pair at pH 2 with safranine-T and its subsequent extraction into chloroform. Fluorescence intensity is increased by a factor of about 5 with respect to that of the reagent. The calibration graph is linear in the concentration range 0.015–0.40 mg l?1 dodecyl sulfate; the relative standard deviation is 5.6% at 0.22 ml l?1 surfactant. The method is applied to determine anionic surfactants in city waste-waters, giving recoveries close to 100%.  相似文献   

17.
《Analytical letters》2012,45(11):2231-2242
ABSTRACT

An spectrophotometric determination of diethylstilbestrol is proposed on the basis of on-line photo-degradation and measurement at 330 nm. The procedure is accomplished by means of flow-injection assembly including a photo-reactor formed by a PTFE 168 cm long coil around a low-pressure mercury lamp 6 w; this photo-reactor was nested between the injection valve and the spectrophotometric flow-cell. The sample solution was injected into a carrier stream of aqueous di-potassium hydrogen ortophosphate flowing at 5.0 ml min?1. Influence of the physic-chemical and hydrodynamic parameters was studied and optimised. The calibration graph was linear up to 65 mg l?1, and the procedure presented a reproducibility (rsd of the calibration slope) 1.4%, and a sample throughput of 52 h?1. The influence of foreign compounds was tested.  相似文献   

18.
2-(5-Bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)aniline rapidly forms a water-soluble complex with palladium in an acetate-buffered medium at pH 3.2.The molar absorptivity of the complex is 9.84×104l mol?1 at 612 nm. The calibration graph is linear over the range of 10–100 μg l?1 palladium; the detection limit is 2 μg l?1 and the relative standard deviation is 0.6% for 100 μg l?1 palladium. The sample throughput is 50 h?1. Divalent transition metals (Fe, Ni, Co) do not interfere at levels from 2 to 10 mg l?1. Interference from copper is prevented by adding 10?3 M EDTA solution to the carrier stream. Palladium in solutions of catalysts and dental alloys can be determined selectively, sensitively and rapidly.  相似文献   

19.
A spectrophotometric flow-injection procedure is described for fluoride in aqueous samples. The method is based on the decrease in absorbance of the zirconium/alizarin red S complex at 520 nm; linear response is obtained for the range 0.1–10 mg l?1 fluoride at a sampling rate of 100 h?1. Aluminum(III), iron(III) and phosphate interfere.  相似文献   

20.
A continuous-flow extraction system coupled on-line with a high-performance liquid chromatograph with an ultraviolet detector is used to study the extraction of three organophosphorus pesticides (fenthion, azinphos methyl and diazinon) from aqueous samples with n-heptane as the organic solvent. Diazinon was not extracted significantly. The influence on the extraction of different parameters (coil length, flow rate and phase volume ratio) were studied. The calibration graphs are linear for 0.5–7 mg l?1 and 8–20 mg l?1 foor azinphos methyl where the percentage extraction (E%) is 90% and 70%, respectively, and up to 4 mg l?1 for fenthion, where the E% is 33%. The detection limits and the relative standard deviations are 0.04 and 0.09 mg l?1, and 3.4 and 5.3%, for azinphos methyl fenthion, respectively. Other pesticides and related compounds were found not to interfere. The sample throughput of this method was 15 h?1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号