首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Conventional residual liquid junction potentials were measured between NBS 1:1 phosphate buffer and various dilute solutions with ionic strengths of 1-100 mmol kg?1, using 3.5 mol kg?1 potassium chloride as the bridge electrolyte. All junctions were of the free-diffusion type, formed within a 1-mm capillary. The conventional residual junction potential was indistinguishable from zero (± 0.5 mV), for dilute solutions of primary reference standards, for which calculations based on the Henderson equation predict values of 0.8–1.3 mV. Solutions of Tris-HCl (20–100 mmol kg?1) and dilute HCl (1–50 mmol kg?1) had appreciable conventional residual liquid junction potentials (1.1–3.3 mV). The experimental values for dilute HCl solutions compare favourably with those calculated with the Henderson equation. These results suggest that the pH of hard waters, measured using the NBS pH scale, will be a good approximation (within 0.01 pH) to paH, so that pH can be interpreted in terms of the activity of the hydrogen ions. Further measurements are required to ascertain whether this approximation is true for soft and acidic waters.  相似文献   

2.
Platinized platinum based hydrogen gas electrodes, Pt(Pt)|H2(g)|H+(aq), and silver‐silver chloride electrodes, Ag|AgCl|Cl? (aq), make up the Harned cell, without transfer, working in the potentiometric mode at Cl? concentrations and ionic strengths, I, below 0.1 mol kg?1, for assigning primary pH values to reference pH buffer solutions. This work reports on experiments performed at higher I and Cl? solutions up to 0.7 mol kg?1, aiming at addressing seawater conditions with results of equally high quality. In the course of measurements, the occasional occurrence of highly unstable potentials denoted electrode malfunction; Pt metal surfaces observed by SEM/EDS and XRD exhibit strong Ag and Cl peaks corresponding to the presence of AgCl crystals deposited at both surfaces.  相似文献   

3.
The values of the thermodynamic second dissociation constant, pK 2, and related thermodynamic quantities of N-(2-hydroxyethyl)piperazine-N′-2-hydroxypropanesulfonic acid (HEPPSO) have already been reported from 5 to 55?°C, including 37?°C, by the emf method. This paper reports the results for the pH of one chloride-free buffer solution containing the composition: (a) HEPPSO (0.08 mol?kg?1)+NaHEPPSO (0.04 mol?kg?1). The remaining seventeen buffer solutions contain a saline medium of ionic strength I=0.16 mol?kg?1, matching closely that of physiological fluids. Conventional pH values, denoted as pa H, for all eighteen buffer solutions from 5 to 55?°C have been calculated. The operational pH values, designated as pH, with residual liquid-junction corrections for five buffer solutions, one without NaCl, and four with buffer solutions in saline media of I=0.16 mol?kg?1 are recommended as pH standards in the range of physiological application. These are based on the NBS/NIST standard scale for pH measurements.  相似文献   

4.
In this study, we report the pH values of two buffer solutions without chloride ion and eight buffer solutions with NaCl with an ionic strength I=0.16 mol?kg?1. Electromotive force (emf) techniques have been used to get the cell potentials at 12 temperatures from 5 to 55?°C, including 37?°C. An extended form of the Bates-Guggenheim convention is used in the entire ionic strength range, 0.04 to 0.16?mol?kg?1. The residual liquid junction potentials (??E j ) of the buffer solutions of MOBS have been estimated from previous measurements with a flowing junction cell. These values of ??E j have been used for correction in order to ascertain the operational pH values of four buffer solutions of MOBS at 25 and 37?°C. These solutions are recommended as pH standards for physiological application in the pH range 7.4 to 7.7.  相似文献   

5.
Isopiestic vapor-pressure measurements were made at the temperature 298.15 K for aqueous KCl + MgCl2 solutions using KCl(aq) as the reference standard. The measurements for these ternary solutions were made at KCl ionic strength fractions of y=0.0, 0.1989, 0.3996, 0.5993, 0.7925 and 1.0 (with two additional sets at y=0.0, 0.2021, 0.3998, 0.6125, 0.8209 and 1.0) for the ionic strength range from 0.4014 to 6.2790 mol?kg?1. Our results, and those from two previous isopiestic studies, were combined and used with previously determined parameters for KCl(aq) and those determined here for MgCl2(aq) to evaluate mixing parameters for the Clegg-Pitzer-Brimblecombe model. These combined data were also used to determine the mixing parameters of the Scatchard model. Both sets of model parameters are valid for ionic strengths of I≤12.8 mol?kg?1, where higher-order electrostatic effects have been included in the Clegg-Pitzer-Brimblecombe mixture model. The activity coefficients for KCl and MgCl2 were calculated from these models and the results for KCl were compared to experimental data from Emf measurements. The Scatchard model interaction parameters were used for calculation of the excess Gibbs energy as a function of the ionic strength and ionic strength fraction of KCl. The Zdanovskii-Robinson-Stokes rule of linearity for mixing of isopiestic solutions was tested.  相似文献   

6.
Electromotive force measurements have been made using the cell $$\mbox{In(s)}|\mbox{HCl }(m_{\mathrm{A}}),\mbox{InCl}_{3}(m_{\mathrm{B}}),\mbox{H}_{2}\mbox{O}|\mbox{AgCl, Ag}$$ in the ionic strength range of I=0.05, 0.1, 0.25, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 mol?kg?1 at 25?°C. The value of E o, the standard potential of the In/In3+ electrode, has been determined at 25?°C. Our value of E o (?0.3371 V) at 25?°C obtained from our measurements is in good agreement with ?0.336 (Hakomori, J. Am. Chem. Soc. 52: 2372–2376, 1930) and ?0.3382 V (Covington et al., J. Chem. Soc. 4394–4401, 1963). The activity coefficients of InCl3 as well as Harned interaction coefficients have been determined at 25?°C for each of the experimental ionic strengths at ionic strength fractions of 0.1, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8 and 0.9 of HCl. Harned’s rule for the salt is obeyed at I=0.05,0.1 and 0.25 mol?kg?1 but the quadratic terms are needed for higher ionic strengths. These data, together with others for the activity coefficient of HCl in the same solutions, have been treated by the ion-interaction (Pitzer, Activity Coefficients in Electrolyte Solutions, CRC Press, 1991) equations in a previous publication.  相似文献   

7.
This paper reports the use of an adsorptive voltammetric technique for Pb(II) determination using cupferron as a selective complexing agent. After accumulation of the complex onto a hanging mercury drop electrode, the electrode potential was scanned with differential pulse modulation and the reduction current of lead was observed at about??0.5?V. Under optimum conditions (5?×?10?4?mol?L?1 cupferron concentration, 0.1?mol?L?1 acetate buffer (pH 5.5), adsorption at??50?mV for 30?s) the detection limit was 5.1?×?10?10?mol?L?1. The relative standard deviation of five measurements for low lead concentration was 3.1%. The accuracy of the method was tested by analysing certified reference material (SPS-WW1 Waste Water). Finally, the method was successfully applied to the determination of Pb(II) in river water samples without any pretreatments.  相似文献   

8.
Using upper consolute temperatures (UCT) and corresponding consolute compositions (CC) of water-phenol systems with each of 0.1 mol kg?1 salts and acids, 1.0% polyethylene glycol 200, 0.01 mol kg?1 surfactant and aromatic compounds, we obtained 0.01 mol kg?1 CaF2 and CrCl3 compositions. Focusing on UCT and CC, the role of valence electrons and shell number, basicity, hydrophilic, hydrophobic and π conjugated electrons of corresponding additives are reported. The surfactants and π conjugation electrons are noted to decrease the UCT in a constant ratio that depicts the state and inherent strength of ionic and molecular-water interactions. The data are useful in the investigation of cloud points of immiscible solutions based on the Hofmeister series.  相似文献   

9.
In this work, the new polyamine bisnaphthalimidopropyl‐4,4’‐diaminodiphenylmethane is proposed as a new ionophore for perchlorate potentiometric sensors. The optimal formulation for the membrane comprised of 12 mmol kg?1 of the ionophore, and 68 % (w/w) of 2‐nitrophenyl phenyl ether as plasticizer and 31 % (w/w) of high molecular weight PVC. The sensors were soaked in water for a week to allow leakage of anionic impurities and for one day in a perchlorate solution (10?4 mol L?1) to improve reproducibility due to its first usage. The stability constant for the ionophore‐perchlorate association in the membrane, log βIL1=3.18±0.04, ensured a performance characterized by the slope of 54.1 (±0.7) mV dec?1 to perchlorate solutions with concentrations between 1.24×10?7 and 1.00×10?3 mol L?1. The sensors are insensitive to pH between 3.5 to 11.0, they have a practical detection limit of 7.66 (±0.42) ×10?8 mol L?1 and a response time below 60 s for solutions with perchlorate concentrations above 5×10?6 mol L?1. The accuracy of the results was confirmed by the analysis of the contaminant in a certified reference water sample.  相似文献   

10.
Precise measurements on the viscosities of the solutions of sodium carboxymethylcellulose in water and in two acetonitrile–water mixtures containing 10 and 20 vol % of acetonitrile have been reported at 35, 40 and 50 °C. Isoionic dilutions were performed with the total ionic strengths of the solutions maintained with sodium chloride at ~4.20 × 10?4 and 1.45 × 10?3 mol dm?3 of NaCl to obtain the intrinsic viscosities. The Huggins constants were also obtained from the experimental results. The influences of the medium, the temperature, and the total ionic strength on the intrinsic viscosities as well as on the Huggins constants have been interpreted from the points of view of the solvodynamic and thermodynamic interactions prevailing in the polyelectrolyte solution under investigation. © 2007 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 45: 1765–1770, 2007  相似文献   

11.
刘佩芳  文利柏 《中国化学》1998,16(3):234-242
The mass transport and charge transfer kinetics of ozone reduction at Nafion coated Au electrodes were studied in 0.5 mol/L H2SO4 and highly resistive solutions such as distilled water and tap water. The diffusion coefficient and partition coefficient of ozone in Nafion coating are 1.78×10-6 cm2·s-1 and 2.75 at 25℃ (based on dry state thickness), respectively. The heterogeneous rate constants and Tafel slopes for ozone reduction at bare Au are 4.1×10-6 cm·s-1, 1.0×10-6 cm·s-1 and 181 mV, 207 mV in 0.5 mol/L H2SO4 and distilled water respectively and the corresponding values for Nafion coated Au are 5.5×10-6 cm·s-1, 1.1×10-6 cm·s-1 and 182 mV, 168 mV respectively. The Au microelectrode with 3 μm Nafion coating shows good linearity over the range 0-10 mmol/L ozone in distilled water with sensitivity 61 μA·ppm-1 ·cm-2, detection limit 10 ppb and 95% response time below 5 s at 25℃. The temperature coefficient in range of 11-30℃ is 1.3%.  相似文献   

12.
《Electroanalysis》2004,16(3):169-174
A fast and sensitive approach to detect reserpine in urine using micellar electrokinetic capillary chromatography with electrochemiluminescence (ECL) of Ru(bpy)32+ detection is described. Using a 25 μm i.d. capillary as separation column, the ECL detector was coupled to the capillary in the absence of an electric field decoupler. Field‐amplified injection was used to minimize the effect of ionic strength in the sample and to achieve high sensitivity. In this way, the sample was analyzed directly without any pretreatment. The method was validated for reserpine in the urine over the range of 1×10?6?1×10?4 mol/L with a correlation coefficient of 0.996. The RSD for reserpine at a level of 5 μmol/L was 4.3%. The LOD (S/N=3) was estimated to be 7.0×10?8 mol/L. The average recoveries for 10 μmol/L reserpine spiked in human urine were 94%.  相似文献   

13.
This paper describes a rapid and sensitive method for determination of the hair dye Basic Blue 41 in wastewater samples using screen‐printed carbon electrodes modified with graphene (SPCE/Gr). The method is based on the reversible reduction of azo groups of the dye at potential of ?0.23 V/?0.26 V, where both the anodic and cathodic currents increased 1,300 % when compared to screen‐printed carbon (SPCE) and glassy carbon electrodes (GCE). The optimization of a square wave voltammetric method was performed by means of 23 factorial design, Doehlert matrix and multi‐response assays, and the best parameters were: frequency (54.8 Hz), step potential (6 mV), pulse amplitude (43.7 mV) and pH 4.5. The analytical curve was constructed from 3.00×10?8 to 2.01×10?6 mol L?1, with detection and quantification limits of 5.00×10?9 and 1.70×10?8 mol L?1, respectively. The repeatability of the method evaluated for 10 consecutive measurements at concentrations of 1.70×10?7 mol L?1 and 1.70×10?6 mol L?1, showed relative standard deviation of 3.56 and 0.57 %, respectively. The sensor based in SPCE/Gr was successfully applied in wastewater samples collected from a drinking water treatment plant and validated by comparison with HPLC‐DAD method with good accuracy.  相似文献   

14.
A novel kind of carbon paste electrode (CPE) was prepared by mixing graphite powder, liquid paraffin and the ionic liquid 1-ethyl-3-methylimidazolium ethylsulfate. The resulting electrode was used for the simultaneous determination of guanosine and adenosine by differential pulse voltammetry. Compared to a conventional CPE, the oxidation peak currents are largely increased, and the oxidation peak potentials are negatively shifted. The electrochemical responses to guanosine and adenosine were investigated. Under optimized conditions, the calibration curves are linear in the concentration range from 1.0?×?10-6?mol?L-1 to 1.6?×?10-4?mol?L-1 for guanosine, and from 1.0?×?10-6?mol?L-1 to 2.7?×?10-4?mol?L-1 for adenosine at pH 3.5. Substances potentially interfering in the biological matrix do no interfere. The method was successfully applied to detect adenosine and guanosine in human urine without sample treatments.
Figure
Cyclic voltammograms on CPE (a) and CILE (b) for 1.0?×?10-4?mol?L-1 adenosine and 1.0?×?10-4?mol?L-1guanosine in a pH 3.5 B-R buffer solution at the scan rate of 100?mV?s-1. Inset was the typical differential pulse voltammograms of 1.0?×?10-4?mol?L-1 adenosine and 1.0?×?10-4?mol?L-1?L guanosine on CILE  相似文献   

15.
《Electroanalysis》2002,14(23):1674-1678
Capillary zone electrophoresis with catalysis‐electrochemical detection has been developed and applied to determining horseradish peroxidase (HRP) at zeptomole levels. In this method, an on‐line enzyme catalysis reactor with a reaction capillary was designed. Isoenzymes of HRP were separated by capillary zone electrophoresis, and then they catalyzed the enzyme substrate 3,3′,5,5′‐tetramethylbenzide (TMB(Red)) and H2O2 in the reaction capillary. The reaction product, TMB(Ox), could be determined using amperometric detection on a carbon fiber microdisk bundle electrode at the outlet of the reaction capillary. Because of enzyme amplification, a significant amount of TMB(Ox) could be produced for detection. Therefore, the limit of detection (LOD) of HRP is very low. The optimum conditions of the method are 1.5×10?2 mol/L borate (pH 7.4) for the run buffer, 2×10?3 mol/L for the concentration of H2O2, 2×10?4 mol/L TMB(Red)+2.0×10?2 mol/L citrate‐phosphate (pH 5.0) for the substrate solution, 40 cm for the liquid pressure height, 20 kV for the separation voltage, 100 mV for the detection potential. HRP could be measured with a detection limit of 4.8×10?12 mol/L or 47.5 zmol (S/N=3). The linear range is from 2.40×10?11 to 2.40×10?8 mol/L. Using this method, commercial HRP was measured at zeptomole within ten minutes.  相似文献   

16.
This study investigates a new approach for the amperometric determination of sulfide using a hematoxylin multiwalled carbon nanotubes modified carbon paste electrode (HM‐MWCNTs/CPE). The experimental results show that HM‐MWCNTs/CPE significantly enhances the electrocatalytic activity towards sulfide oxidation. Cyclic voltammetric studies show that the peak potential of sulfide shifted from +400 mV at unmodified CPE to +175 mV at HM‐MWCNTs/CPE. The currents obtained from amperometric measurements at optimum conditions were linearly correlated with the concentration of sulfide. The calibration curve was obtained for sulfide concentrations in the range of 0.5–150×10?6 mol L?1. The detection limit was found to be 0.2×10?6 mol L?1 for the amperometric method. The proposed method was successfully applied to a river water sample in Pardubice, Czech Republic.  相似文献   

17.
The formation constants of species formed in the systems H+?+?W(VI)?+?nitrilotriacetic acid (NTA) and H+?+?NTA have been determined in aqueous solution for pH?=?4–9 at 25°C and different ionic strengths ranging from 0.1 to 1.0?mol?dm?3 NaClO4, using potentiometric and spectrophotometric techniques. It was shown that tungsten(VI) forms a mononuclear 1?:?1 complex with NTA of the type WO3L3? at pH?=?7.5. The composition of the complex was determined by the continuous variations method. The complexation of molybdenum(VI) with glutamic acid was investigated in aqueous solution ranging in pH from 4 to 9, using polarimetric, potentiometric and spectrophotometric techniques. The composition of the complex was determined by the continuous variations method. It was shown that molybdenum(VI) forms a mononuclear 1?:?1 complex with glutamic acid of the type MoO3L2? at pH?=?6.0. The dissociation constants of glutamic acid and the stability constants of the complex were determined at 25°C and at ionic strengths ranging from 0.1 to 1.0?mol?dm?3 sodium perchlorate. In both complex formation reactions the dependence of the dissociation and stability constants on ionic strength is described by a Debye-Huckel type equation. Finally, a comparison has been made between the patterns of ionic strength dependence for the two complexes and the results have been compared with data previously reported.  相似文献   

18.
In this paper a graphene (GR) modified carbon ionic liquid electrode (CILE) was fabricated and used as the voltammetric sensor for the sensitive detection of catechol. Due to the specific physicochemical characteristics of GR such as high surface area, excellent conductivity and good electrochemical properties, the modified electrode exhibits rapid response and strong catalytic activity with high stability toward the electrochemical oxidation of catechol. A pair of well‐defined redox peaks appeared with the anodic and the cathodic peak potential located at 225 mV and 133 mV (vs.SCE) in pH 6.5 phosphate buffer solution, respectively. Electrochemical behaviors of catechol on the GR modified CILE were carefully investigated and the electrochemical parameters were calculated with the results of the electrode reaction standard rate constant (ks) as 1.24 s?1, the charge transfer coefficient (α) as 0.4 and the electron transfer number (n) as 2. Under the selected conditions the differential pulse voltammetric peak current increased linearly with the catechol concentrations in the range from 1.0 × 10‐7 to 7.0 × 10?4mol L‐1 with the detection limit as 3.0 × 10?8mol L‐1 (3σ). The proposed method was further applied to the synthetic waste water samples determination with satisfactory results  相似文献   

19.
The apparent molar volumes, V φ , of L-aspartic acid, L-glutamic acid, L-lysine monohydrate and L-arginine in water and in aqueous (0.1, 0.25, 0.5 and 1.0) mol?kg?1 sodium acetate and sodium propionate, and (0.1, 0.25 and 0.5) mol?kg?1 sodium butyrate solutions have been determined at 288.15, 298.15, 308.15 and 318.15 K from density measurements. The partial molar volumes at infinite dilution, V 2 o , obtained from V φ data, have been used to calculate hydration numbers and partial molar expansibilities of amino acids in water and in the presence of the studied cosolutes at different temperatures. These parameters have been discussed in terms of various interactions between the acidic/basic amino acids and organic salts in these solutions. The effect of the hydrophobic chain length of the carboxylate ions has also been discussed.  相似文献   

20.
This study is aimed to develop an electroanalytical methodology using a boron‐doped diamond electrode (BDD) associated with experimental design in order to determine simultaneously and selectively carbendazin (CBZ) and fenamiphos (FNP) pesticides. In previous studies oxidation peaks were observed at 1.10 V (CBZ) and 1.20 V (FNP), respectively, with characteristics of irreversible processes controlled by diffusion of species (in pH 2.0 (CBZ) and pH 3.5 (FNP)) using a BR buffer 0.1 mol L?1 as support electrolyte. The differences between the potentials for both pesticides, (about 100 mV) indicate the possibility of selective determination of FNP and CBZ. However, employing an equimolar mixture of analytes, the peaks overlap to form a single oxidation peak. Thus, we used a 34 full factorial design with four parameters to be analyzed in three levels, in order to obtain the optimized parameters for the separation of the peaks. The best separation conditions were pH 5.0, square wave frequency of 300 s?1, pulse amplitude of 10 mV and scan increment of 2 mV. These parameters were used to obtain the calibration curves of CBZ and FNP. For CBZ the analytical curve was obtained in the concentration range of 4.95×10?6 to 6.90×10?5 mol L?1 with good sensitivity and linearity (0.175 A/mol L?1 and 0.999, respectively). The limits of detection (LOD) and quantification (LOQ) were 1.6×10?6 mol L?1 and 5.5×10?6 mol L?1, respectively. For FNP the linear concentration interval was 4.95×10?6 to 3.67×10?5 mol L?1, with a sensitivity of 0,207 A/mol L?1 and linearity of 0.996. The LOD and LOQ were 4.1×10?6 mol L?1 and 13.7×10?6 mol L?1, respectively. Using these experimental conditions it was possible to separate the oxidation peaks of CBZ (Ep=1.08 V) and FNP (Ep=1.23 V). The electroanlytical method was applied in lemon juice samples. The recovery values were 110.0 % and 92.5 % for CBZ and FNP, respectively. The results showed that the developed method is suitable for application in foodstuff samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号