A simple and rapid SPE-GC method for the determination of 30 organochlorine, organophosphorus, and organonitrogen pesticides at ng/L levels in washing water of olive processing has been developed. Twenty-nine samples of water were collected directly in the inlet and outlet of the washing machines of three olive mills at various locations in Spain. Preconcentration and clean-up were performed by elution of the pesticides from a C18 SPE cartridge using dichloromethane. The target compounds were determined in the final extract by GC-MS/MS. The most frequently encountered pesticide residues were terbuthylazine, simazine, and diuron. In some of the water samples, coming from the inlet of the washing machines, terbuthylazine and diuron concentrations were above the maximum residue limit.  相似文献   

2.
A multiresidue method for determination of 15 organochlorine pesticides (OCPs), six polychlorinated biphenyls (PCBs), and seven organophosphorus pesticides (OPPs) is implemented for routine determinations of residues in honey. The method involves solid-phase extraction cleanup and determination by GC–ECD/NPD. Quantitation limits ranged from 0.1 to 0.6 g kg–1 honey for OCPs and PCBs, and from 5.0 to 25.0 g kg–1 honey for OPPs. Recoveries of OCPs ranged between 77.4 and 94.0%; for PCBs they were from 63.8 to 73.5%. Recovery assays for OPPs varied from 66.7 to 98.1%. The method was applied to the analysis of 111 honey samples from Aragón, Spain. The results obtained indicated a low level of contamination by pesticide residues and PCBs, which can contribute to ensuring the consumer has a safe wholesome supply of honey.  相似文献   

3.
A method based on automated solid-phase extraction (SPE) and isotope dilution gas chromatography/high resolution mass spectrometry (GC/HRMS) has been developed for the analysis of nine nitrosamines in water samples. The combination of automated SPE and GC/HRMS for the analysis of nitrosamines has not been reported previously. The method shows as advantages the selectivity and sensitivity of GC/HRMS analysis and the high efficiency of automated SPE with coconut charcoal EPA 521 cartridges. Low method detection limits (MDLs) were achieved, along with a greater facility of the procedure and less dependance on the operator with regard to the methods based on manual SPE. Quality requirements for isotope dilution-based methods were accomplished for most analysed nitrosamines, regarding to trueness (80–120%), method precision (<15%) and MDLs (0.08–1.7 ng/L).Nineteen water samples (16 samples from a drinking water treatment plant {DWTP}, 2 chlorinated samples from a sewage treatment plant {STP} effluent, and 1 chlorinated sample from a reservoir) were analysed. Concentrations of nitrosamines in the STP effluent were 309.4 and 730.2 ng/L, being higher when higher doses of chlorine were applied. N-Nitrosodimethylamine (NDMA) and N-nitrosodiethylamine (NDEA) were the main compounds identified in the STP effluent, and NDEA was detected above 200 ng/L, regulatory level for NDMA in effluents stated in Ontario (Canada). Lower concentrations of nitrosamines were found in the reservoir (20.3 ng/L) and in the DWTP samples (n.d. −28.6 ng/L). NDMA and NDEA were respectively found in the reservoir and in treated and highly chlorinated DWTP samples at concentrations above 10 ng/L (guide value established in different countries). The highest concentrations of nitrosamines were found after chlorination and ozonation processes (ozonated, treated and highly chlorinated water) in DWTP samples.  相似文献   

4.
During oil and gas exploitation, large amounts of produced water are generated. This water has to be analyzed with relation to the chemical composition to deduce the environmental impact of its discharge after a treatment process. Therefore, a study was carried out to evaluate preliminarily the BTEX (benzene, toluene, ethylbenzene and xylenes), polycyclic aromatic hydrocarbons (PAHs) and metals contents in produced water samples taken from effluents of the Bonsucesso treatment plant located in the city of Carmópolis, the most important oil and gas producer in the State of Sergipe, North-east of Brazil. Three methods were optimized to determine the target compounds. Polycyclic aromatic hydrocarbons were determined by gas chromatography with mass spectrometric detection (GC/MS), volatile aromatic hydrocarbons (BTEX) by gas chromatography with photoionization detector (GC/PID) and metals were analyzed by flame atomic absorption spectrometry (FAAS). The results showed that concentrations of the target compounds in these samples ranged from 96.7 to 1397 μg L− 1 for BTEX, from 0.9 to 10.3 μg L− 1 for PAHs and from 0.003 to 4540 mg L− 1 for metals.  相似文献   

5.
In this work, we propose solvent-based de-emulsification dispersive liquid–liquid microextraction (SD-DLLME) as a simple, rapid and efficient sample pretreatment technique for the extraction and preconcentration of organochlorine pesticides (OCPs) from environmental water samples. Separation and analysis of fifteen OCPs was carried out by gas chromatography–mass spectrometry (GC/MS). Parameters affecting the extraction efficiency were systematically investigated. The detection limits were in the range of 2–50 ng L−1 using selective ion monitoring (SIM). The precision of the proposed method, expressed as relative standard deviation, varied between 3.5 and 10.2% (n = 5). Results from the analysis of spiked environmental water samples at the low-ppb level met the acceptance criteria set by the EPA.  相似文献   

6.
《Analytical letters》2012,45(4):835-850
Abstract

In the present work, a method for the simultaneous determination of five herbicides, diuron, simazine, atrazine, terbuthylazine and terbutryn by GC‐electron capture detection (ECD) and GC‐thermoionic specific detector (TSD) in soil and mud samples (from olives washing devices) has been developed. Extraction of the herbicides from soil samples was carried out by liquid–solid extraction with ciclohexane/acetone under sonication. In addition, a clean‐up step by solid phase extraction (SPE) using alumina was necessary for mud samples to remove fat residues in the extracts. Spiked soil standards were used for calibration. Limit of detection (LOD) values ranged between 0.2–1.4 ng g?1 and limit of quantitation (LOQ) between 1.4–2.0 ng g?1. The precision of the method was satisfactory for all the herbicides analyzed, with RSD values ranging between 7.5%–32.3% and 8.5%–17.8% for 10 and 100 ng g?1 spiking levels, respectively. The accuracy of the method was checked at three spiking levels (10, 50, and 100 ng g?1) with recovery values ranging from 74.2%–129.1%. In the case of mud samples, mean recovery values (100 ng g?1 spiking level) were acceptable for diuron (69.5%) and more satisfactory in the case of triazine herbicides (81.0%–123.0%). Diuron and terbuthylazine were the herbicides most frequently detected in the analyzed samples.  相似文献   

7.
A mixed anionic–cationic surfactant cloud point extraction (CPE) has been developed using sodium dodecyl sulfate (SDS) and tetrabutylammonium bromide (TBABr) for the extraction and preconcentration of organophosphorus pesticides (OPPs) at ambient temperature before analysis by high-performance liquid chromatography. The studied OPPs were azinphos-methyl, parathion-methyl, fenitrothion, diazinon, chlorpyrifos, and prothiophos. The optimum conditions of the mixed anionic–cationic CPE were 50 mmol L−1 SDS, 100 mmol L−1 TBABr, and 10% (w/v) NaCl. The extracted OPPs were successfully separated within 11 min using the conditions of a Waters Symmetry C8 column, a flow rate of 0.8 mL min−1, a gradient elution of methanol and water, and detection at 210 nm. Linearity was found over the range 0.05–5 μg mL−1, with the correlation coefficients higher than 0.996. The enrichment factor of the target analytes was in the range 6–11, which corresponds to their limits of detection from 1 to 30 ng mL−1. High precisions (intra-day and inter-day) were obtained with relative standard deviation <1.5% (t R) and 10% (peak area). Accuracies (% recovery) of the different spiked OPP concentrations were 82.7–109.1% (water samples) and 80.3–113.3% (fruit juice samples). No contamination by the OPPs was observed in any studied samples.  相似文献   

8.
An in-syringe ultrasound-assisted emulsification microextraction (USAEME) was developed for the extraction of organophosphorus pesticides (OPPs) from water samples. The OPPs subsequently analyzed gas chromatography (GC) using a microelectron capture detector (μECD). Ultrasound radiation was applied to accelerate the emulsification of μL-level low-density organic solvent in aqueous solutions to enhance the microextraction efficiency of OPPs in the sample preparation for GC-μECD. Parameters affecting the efficiency of USAEME, such as the extraction solvent, solvent volume, pH, salt-addition, and extraction time were thoroughly investigated. Based on experimental results, OPPs were extracted from a 5 mL aqueous sample by the addition of 20 μL toluene as the extraction solvent, followed by ultrasonication for 30 s, and then centrifugation for 3 min at 3200 rpm, offered the best extraction efficiency. Detections were linear in the concentration of 0.01–1 μg/L with detection limits between 1 ng/L and 2 ng/L for OPPs. Enrichment factors ranged from 330 to 699. Three spiked aqueous samples were analyzed, and recovery ranged from 90.1% to 104.7% for farm-field water, and 90.1% to 101.8% for industrial wastewater. The proposed method provides a simple, rapid, sensitive, inexpensive, and eco-friendly process for determining OPPs in water samples.  相似文献   

9.
Xiong C  He M  Hu B 《Talanta》2008,76(4):772-779
A new, simple, and selective method has been presented for the separation and preconcentration of inorganic arsenic (As(III)/As(V)) and selenium (Se(IV)/Se(VI)) species by a microcolumn on-line coupled with inductively coupled plasma-optical emission spectrometry (ICP-OES). Trace amounts of As(V) and Se(VI) species were separated and preconcentrated from total As and Se at desired pH values by a conical microcolumn packed with cetyltrimethylammonium bromide (CTAB)-modified alkyl silica sorbent in the absence of chelating reagent. The species adsorbed by CTAB-modified alkyl silica sorbent were quantitatively desorbed with 0.10 ml of 1.0 mol l−1 HNO3. Total inorganic arsenic and selenium were similarly extracted after oxidation of As(III) and Se(IV) to As(V) and Se(VI) with KMnO4 (50.0 μmol l−1). The assay of As(III) and Se(IV) were based on subtracting As(V) and Se(VI) from total As and total Se, respectively. All parameters affecting the separation/preconcentration of As(V) and Se(VI) including pH, sample flow rate and volume, eluent solution and volume have been studied. With a sample volume of 3.0 ml, the sample throughput was 24 h−1 and the enrichment factors for As(V) and Se(VI) were 26.7 and 27.6, respectively. The limits of detection (LODs) were 0.15 μg l−1 for As(V) and 0.10 μg l−1 for Se(VI). The relative standard deviations (RSDs) for nine replicate determinations at 5.0 μg l−1 level of As(V) and Se(VI) were 4.0% and 3.6%, respectively. The calibration graphs of the method for As(V) and Se(VI) were linear in the range of 0.5–1000.0 μg l−1 with a correlation coefficient of 0.9936 and 0.9992, respectively. The developed method was successfully applied to the speciation analysis of inorganic arsenic and selenium in natural water samples with satisfactory results.  相似文献   

10.
Díaz TG  Cabanillas AG  Soto MD  Ortiz JM 《Talanta》2008,76(4):809-814
Square-wave adsorptive-stripping voltammetry technique has been used to develop a method for the determination of fenthion in olive oil. Due to the fact that fenthion does not give any electrochemical signal at mercury electrode, the method has been based on a previous oxidation of fenthion to its metabolite, fenthion-sulfoxide, by using KMnO4. The metabolite gives rise to a peak due to an adsorptive-reductive process at −0.786 V. Fenthion is isolated from olive oil by carrying out a solid–liquid extraction procedure using silica cartridge, followed by a liquid–liquid partitioning with acetonitrile. The detection limit in olive oil is 78.8 ng g−1 and recoveries for four levels of fortification are ranged from 85% to 109%. On the other hand, it has been developed a method for the simultaneous determination of fenthion and its metabolite fenthion-sulfoxide, in river water. Pesticides are isolated from water by carrying out a liquid–liquid partitioning with trichloromethane. The detection limits are 0.41 ng g−1 and 0.44 ng g−1, for fenthion and fenthion-sulfoxide, respectively. Recoveries for three levels of fortification are ranged from 96% to 103% for fenthion and 94% to 104% for fenthion-sulfoxide.  相似文献   

11.
An efficient and fast microwave-assisted extraction (MAE) method followed by gas chromatographic separation with mass spectrometric detection (GC–MS) was developed for the extraction of 18 organochlorine pesticides (OCPs) from sediment. Parameters affecting the MAE procedure such as the type and volume of the extraction solvent, irradiation power, temperature and irradiation time were successfully optimised. Under the optimal conditions, extraction efficiencies in the range of 73.4–119% were obtained with THF–HEX (9:1, v/v) for all OCPs studied. The method was linear over the range of 2.9–5000 ng g?1 with determination coefficients (r2) higher than 0.992 for all analytes. The limits of detection, LODs (S/N = 3), obtained varied from 1.0 to 2.2 ng g?1 and limits of quantification, LOQs (S/N = 10) were between 2.9 and 6.8 ng g?1. The proposed method was successfully applied to the analysis of real sediment samples and acceptable recoveries from 70.1 to 124% with RSDs ≤14.8% were obtained. 10 OCPs were determined below their LOQ and 8 OCPs in the range of 124–2830 ng g?1. The MAE method was compared with Soxhlet, shake flask and ultrasonic solvent extraction techniques. Thus, the MAE–GC–MS method could efficiently be used for selective extraction and quantification of the target analytes from the complex sediment matrices.  相似文献   

12.
Sea surface microlayer (SML) and sea water samples (SSW) collected in the Gerlache Inlet Sea (Antarctica) were analysed for n-alkanes and polycyclic aromatic hydrocarbons (PAHs). The SML is a potential enrichment site of hydrophobic organic compounds compared to the underlying water column. Total concentration ranges of n-alkanes and PAHs (dissolved and particulate) in subsurface water (− 0.5 m depth) were 272-553 ng l− 1 (mean: 448 ng l− 1) and 5.27-9.43 ng l− 1 (mean: 7.06 ng l− 1), respectively. In the SML, the concentration ranges of n-alkanes and PAHs were 353-968 ng l− 1 (mean: 611 ng l− 1) and 7.32-23.94 ng l− 1 (mean: 13.22 ng l− 1), respectively. To evaluate possible PAH contamination sources, specific PAH ratios were calculated. The ratios reflected a predominant petrogenic input. A characterisation of surface active substances was also performed on SML and SSW samples, both by gas bubble extraction, and by dynamic surface tension measurements. Results showed a good correlation between n-alkanes, PAHs and refractory organic matter.  相似文献   

13.
The feasibility of circulating cooling-solid phase microextraction (CC-SPME) combined with gas chromatography-nitrogen phosphorous detector (GC-NPD) for the determination of five organophosphorous pesticides (OPPs) in tomato samples is evaluated. By heating the sample while cooling the fiber coating, the developed method provides better performance in terms of sensitivity, linearity and recovery than that of traditional headspace-solid phase microextraction (HS-SPME). The extraction capacities of activated carbon fiber (ACF) and three commercially available fibers were compared. ACF is found to be the most suitable fiber for the analysis of OPPs in tomatoes. The main factors affecting the CC-SPME process such as adsorption time, adsorption temperature and ionic strength were investigated and optimized. The matrix effect was evaluated, and concluded that addition of water is required to reduce the matrix effect. Good linearity (R 2 > 0.992) is observed in the 1–200 ng g−1 concentration range with satisfactory RSD (%) values of 5.6–8.5%. The limits of detection obtained using the proposed method range from 0.2 to 0.5 ng g−1, and the recoveries for CC-SPME are in the range of 82.5–90.0% with RSDs lower than 8.7%. Experimental results confirm the usefulness of the proposed method for the analysis of OPPs in tomato samples.  相似文献   

14.
Summary The determination of selected pesticides and phenols in Portuguese river water samples was carried out from April to September, 1999. The method involved 200 mL samples taken by offline, solid phase extraction by OASIS polymeric cartridges followed by liquid chromatography-atmospheric pressure, chemical ionization-mass spectrometry (LC-APCI-MS). Recoveries of pesticides were 50–96% and 72–120% for the Platform and HP 1100 instruments, respectively. Chlorophenols gave recoveries of 60–91%. Triazines and transformation products like desethylatrazine (DEA) and desisopropylatrazine (DIA) and compounds such as diuron and chlorophenols were positively identified by LC-APCI-MS. The levels detected of the different compounds varied from 0.01–2.61 μg L−1, the most frequently detected compounds being, atrazine, simazine, terbuthylazine, alachlor, metolachlor, Irgarol, diuron, 2,4,6-trichlorophenol, desisopropylatrazine and desethylatrazine.  相似文献   

15.
A methodology for monitoring low level of caffeine in aqueous samples via gas chromatography coupled with an ion-trap tandem mass spectrometry detection system (IT-MS/MS) was developed. Four IT-MS/MS operating parameters, including the collision-induced dissociation (CID) voltage, the excitation time (ET), the isolation time (IT) and the maximum ionization time (MIT) were optimized in order to maximize the sensitivity of the IT-MS/MS technique towards the analyte and its isotope-labeled standard. After optimization, a limit of detection of 500 fg μl−1 with S/N = 3 was achieved. Taking into account blank values and the matrix background, a method detection limit of 1.0–2.0 ng l−1 was derived and applied to all of the samples analyzed in the study. Various mass spectrometric conditions have been applied to caffeine and its trimethyl-13C-labeled standard to elucidate fragmentation pathways for new and commonly occurring product ions observed in the collision-induced dissociation (CID) spectra produced by the ion trap. Ion structures and fragmentation pathway mechanisms have been proposed and compared with previously published data. An isotope dilution method using 13C-labeled caffeine as a surrogate internal standard was employed to determine and correct the recovery of native caffeine in water samples. The developed methodology has been applied for the determination of caffeine in surface marine and freshwater samples collected on the west coast of Vancouver Island in British Columbia, Canada. The results obtained for the marine water samples indicated a wide variation in the level of caffeine, ranging from 4.5 to 149 ng l−1, depending on the location of the sampling site within the inlet. The concentrations of caffeine in samples from lakes associated with various residential densities ranged from ND to 6.5, 1.8 to 10.4 and 6.1 to 21.7 ng l−1 for low, moderate and high residential densities, respectively.  相似文献   

16.
Solid phase microextraction (SPME) then capillary gas chromatography with mass spectrometric detection have been used for determination of nine phenyl compounds in snow water in Beijing City. Headspace extraction with a fiber coated with 100 µm PDMS was used to extract the compounds. Extraction and desorption times were optimized at 8 and 2 min, respectively. Relative standard deviation (RSD) of the analytical method was found to be less than 5%. The linear range was wide and limits of detection were less than 5 ng mL−1 for the nine target analytes. Several phenyl compounds at ng mL−1 levels were detected in snow samples in Beijing, indicating the corresponding air pollution.  相似文献   

17.
A procedure for the simultaneous determination of six organotin compounds, including methyl-, butyl- and phenyltins, in waters and marine sediments is developed. The analytes were leached from the solid samples into an acetic acid:methanol mixture by using an ultrasonic probe. The organotins were derivatized with sodium tetraethylborate (NaBEt4) in the aqueous phase, stripped by a flow of helium, pre-concentrated in a trap and thermally desorbed. This was followed by capillary gas chromatography with microwave-induced plasma atomic emission spectrometry as the detection system (GC-AED). Each chromatographic run took 22 min, including the purge time. Calibration curves were obtained by plotting peak area versus concentration and the correlation coefficients for linear calibration were at least 0.9991. Detection limits ranged from 11 to 50 ng Sn l−1 for tributyltin and tetramethyltin, respectively. The seawater samples analyzed contained variable concentrations of mono-, di- and tributyl- and monophenyltin, ranging from 0.05 to 0.48 μg Sn l−1, depending on the compound. Some of the sediments analyzed contained concentrations of dibutyl- and tributyltin of between 6.0 and 13.0 ng Sn g−1. Analysis of the certified reference material PACS-2, as well as of spiked water and sediment samples showed the accuracy of the method. The proposed method is selective and reproducible, and is considered suitable for monitoring organotin compounds in water and sediment samples.  相似文献   

18.
The use of two modes for mass spectrometry (MS) detection with an ion trap instrument, selected ion storage (SIS) and tandem mass spectrometry (MS/MS), are compared for the solid-phase microextraction (SPME)–gas chromatography (GC) coupled to mass spectrometry (GC-MS) determination of 16 priority organochlorine pesticides (OCPs) in drinking water samples at the ultratrace levels (ng?L?1) required by official guidelines in the European legislation. Experimental parameters investigated for the SPME sample preparation were: the type of coating (100?µm polydimethylsiloxane, PDMS, and 65?µm poly(dimethylsiloxane)–divinylbenzene, PDMS/DVB), SPME modality, extraction and desorption times and desorption temperature and the methanol percentage in the SPME working solution. Under the calculated optimal conditions two methodologies were developed, one for SIS and the other for MS/MS modes. The detection limits, precision and accuracy were evaluated for both alternatives and were appropriate to the official guidelines requirements. The SPME–GC-MS(SIS) methodology offered LODs from 0.2–6.6?ng?L?1, precision below 13% and recoveries between 83 and 110%. The SPME–GC–MS/MS methodology provided limits of detection (LODs) ranging from 0.3 to 7.6 ng?L?1, % RSD were ≤14% and recoveries of 79–108% were achieved. After the results observed within an Interlaboratory Exercise, the latest MS methodology was selected for the pursued analysis in real drinking water samples. Also, the good results in this round-robin exercise validate the proposed SPME–GC–MS/MS methodology.  相似文献   

19.
Magnetic solid-phase extraction (MSPE) coupled with gas chromatography–mass spectrometry was applied for the analysis of organophosphorus pesticides (OPPs) in water samples. We chose C18-functionalized Fe3O4@mSiO2 microspheres as the magnetic sorbents to extract and enrich OPPs from water samples with the advantages of good solubility in water, large surface area and fast separation ability. In this study, six kinds of OPPs were analyzed and various parameters of MSPE procedure, including eluting solvent, the amount of magnetic absorbents and extraction time were optimized. Validation experiments showed that the optimized method had good linearity with correlation coefficients r 2 > 0.98 and satisfactory precision with the relative standard deviation ≤10.7 %. The limits of detection were 1.8–5.0 μg L?1 and the limits of quantification ranged from 6.1 to 16.7 μg L?1. We concluded that the proposed method was successfully applied to analyze OPPs in real water samples and the results indicated that it had the advantages of simplicity, convenience and efficiency.  相似文献   

20.
In this study, a microextraction method termed as ultrasound‐assisted emulsification–microextraction (USAEME) has been developed for the extraction of organophosphorus pesticides (OPPs) in water and orange juice samples. In the USAEME method, aliquots of 50 μL chlorobenzene used as extraction solvent was added to 10 mL water sample in a conical glass centrifugal tube. Factors influencing the USAEME extraction efficiency such as sonication time, extraction solvent, extraction volume and salt addition were evaluated. Under the optimum conditions, enrichment factors ranged from 241 to 311, LOD varied from 5.3 to 10.0 ng/L and linearity with a coefficient of estimation (r2) varied from 0.9991 to 0.9998 in the concentration level range of 0.05–2.5 μg/L for the extraction of OPPs in water samples. Finally, the proposed USAEME method was used for the extraction of OPPs from water and orange juice. The recoveries were in the range of 80.0–110.0%, and the repeatability of the method expressed as RSD (n=3) varied between 1.6 and 13%. The USAEME method has the advantage of being easy to operate, low consumption of organic solvent and high extraction efficiency.  相似文献   