首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
铬铁矿中铁的快速测定方法研究   总被引:1,自引:0,他引:1  
研究了铬铁矿中铁的测定方法问题。基于测定铬铁矿中铬的溶样方法原理和对传统无汞测铁程序的改进研究,推荐了一个测定铬铁矿中铁的快速方法模式:试样经沸腾硫酸湿烧(~330℃)、磷-硫混合酸溶解、直接用三氯化钛溶液还原铁(Ⅲ→Ⅱ)、过量钛(Ⅲ)自然被氧化后,用常规法滴定之。所提供的快速方法测得之结果准确可靠(RSD=0.55%~0.80%,n=8),适于普遍推广应用。  相似文献   

2.
A high performance liquid chromatography (HPLC) method with fluorescence detection including an on-line purification was established for determination of catecholamines in human urine. The method was evaluated using samples of pooled urine spiked with catecholamines and validated for measurements of catecholamines in urine of healthy individuals in a field study. The laboratory method evaluation study showed that the recovery of the method was 0.82 (confidence interval (CI): 0.79-0.86) and 0.92 (CI: 0.89-0.95) for noradrenaline and adrenaline, respectively. Thus, correction factors of 0.82(-1) and 0.92(-1) were applied to correct the measurement results for this systematic effect. Furthermore, an uncertainty budget was generated for the analytical method using the BIPM-approach recommended by the International Organization for Standardization. The relative uncertainty of the method was estimated to be 10-12%, which was consistent with the observed relative variability found in the method evaluation. The method was evaluated in accordance with EURACHEM Guidance Document No 1 concerning accreditation for chemical laboratories with respect to accuracy and precision. The field study showed that the standard deviation of the method was sufficiently low to distinguish between persons working with two different processes of garbage collection, i.e. collection using four wheeled containers versus collection using bins.  相似文献   

3.
A high-accuracy exact-matching isotope dilution mass spectrometry (IDMS) method for 19-norandrosterone (19-NA) in human urine was developed at NMIA for the certification of a freeze-dried human urine reference material (CRM NMIA MX002). The method utilised GC/HRMS analysis following hydrolysis, solvent extraction, HPLC fractionation and derivatisation. The method development included investigation of all potential analytical biases for the different stages of the method and included development of a confirmatory LC/MS/MS method. The measurement uncertainty of the reference method was rigorously investigated with the achieved expanded uncertainty being less than 4% at the 95% level of confidence. The method was used in the Comité Consultatif pour la Quantité de Matière (CCQM) pilot study CCQM-P68 which was an interlaboratory intercomparison for the analysis of 19-NA in human urine in which four national metrology institutes (NMIs) participated in. The agreement in the results from the NMIA method with those from the other NMIs was excellent.  相似文献   

4.
An efficient, economic and high yielding method was described for the synthesis of baclofen (BAC) pharmacopoeial impurities (impurity A and impurity B) which can be used for gram‐scale synthesis. Furthermore, a novel ecofriendly thin‐layer chromatographic TLC–densitometric method was established and validated for the determination of BAC and its synthesized impurities. The developed TLC–densitometric method is based on the chromatographic separation using TLC plates (60 F254) using a green mobile phase of ethyl acetate–methanol–ammonia solution, 33% (8:2:0.1, by volume) with UV scanning at 220 nm. The proposed method was validated with respect to International Conference on Harmonization guidelines. The validated method was successfully applied for determination of BAC in pure form and in its commercial dosage form. Additionally, the greenness profile of the developed method was evaluated and compared with those of the reported chromatographic methods. The developed method was found to be superior to the published methods, being environmentally benign.  相似文献   

5.
刘文媛  贾伟  吴婷  张春晖  李侠  陈雪峰 《色谱》2016,34(11):1113-1119
利用气相色谱(GC)技术,采用酸水解提取脂质,比较了6种甲酯化法(乙酰氯-甲醇法、H2SO4-甲醇法、HCl-甲醇法、KOH-甲醇法、KOH-甲醇+H2SO4-甲醇法和KOH-甲醇+HCl-甲醇法)对脂肪酸测定的影响,优选牦牛骨中脂肪酸测定的最佳方法。37种脂肪酸标准样品在0.28~250.00 mg/L范围内线性关系良好,相关系数均大于0.99(除C4:0外)。碱酯化法和酸碱结合法几乎无法测出牦牛骨中的脂肪酸,其测得的总脂肪酸含量小于0.20 g/100 g。乙酰氯-甲醇法测得的总脂肪酸含量(13.61 g/100 g)显著高于H2SO4-甲醇法(总脂肪酸含量为11.68 g/100 g)和HCl-甲醇法(总脂肪酸含量为3.18 g/100 g)测得的结果。乙酰氯-甲醇法和H2SO4-甲醇法的日内和日间精密度分别为0.27%~8.60%和0.34%~2.64%,两种方法中脂肪酸的回收率为83.06%~105.54%。结果表明,酸水解-乙酰氯-甲醇法是牦牛骨中脂肪酸测定的最佳方法。C18:1n9c、C16:0、C18:0和共轭亚油酸(CLA)是牦牛骨的主要脂肪酸,其总和达脂肪酸总量的85%以上,饱和脂肪酸与不饱和脂肪酸含量比值约为1:2。牦牛骨中脂肪酸的研究为骨资源脂质的有效利用提供了重要依据。  相似文献   

6.
We report a simple TLC densitometric method for the quantification of hecogenin from the leaves of Agave americana using HPTLC. The method was validated for precision, repeatability and accuracy. The method was found to be precise with RSD of 0.78 (intraday) and 0.82 (interday) for different concentrations of hecogenin. Instrumental precision was 0.42 (% RSD) for hecogenin. The content of hecogenin in different samples was estimated by the proposed method and was found to be in the range of 0.05−0.14% w/w in the samples analysed. Accuracy of the method was checked by conducting recovery study at three different levels for hecogenin and the average percentage recovery was 98.98%, 101.92% and 103.33%, respectively. The TLC densitometric method developed for the quantification of hecogenin was found to be simple, precise, specific, sensitive, accurate and can be used in routine quality control. Revised: 7 and 25 April 2006  相似文献   

7.
建立了微波消解前处理,全反射X射线荧光法(TXRF)同时测定松花粉中K、Ca、Ti、Mn、Fe、Ni、Cu、Zn和Rb9种生命元素含量的分析方法.松花粉原料经过微波消解前处理后,采用全反射X射线荧光光谱净计数、QXAS分析软件解谱和单一内标法进行定量分析.比较了干灰化法、湿消解法和微波消解法3种前处理方法的效果,并确立微波消解法作为样品前处理方法.用微波消解- TXRF法测定了花粉标准物质中的上述9种元素,并计算得到其仪器检出限(LLD)为0.002~0.054 mg/L,方法检出限(LDM)为0.004~0.122 mg/kg.TXRF法测定各元素的相对标准偏差(RSDs)为1.0%~5.5%.该方法操作简单、样品用量少、检出限低,对实际样品松花粉的测定结果与ICP - MS法无显著性差异.  相似文献   

8.
A study was conducted to compare the current conventional method and the impedance method for rapid detection of total counts of bacteria and fungi in bottled purified water. The results indicated that the corresponding detection rate for the 2 methods was 94.5 and 90.4%, respectively. The detection time was shortened from 48 h (bacteria) and 5 days (fungi) to 14.5 and 44 h, respectively. Moreover, for more serious contamination, less time was needed. The impedance method predicted a positive sample within 11.3 h (bacteria) and 27.1 h (fungi). Therefore, the impedance method was found to be a rapid, accurate method.  相似文献   

9.
A method for determining crude fat in animal feed, cereal grain, and forage (plant tissue) was collaboratively studied. Crude fat was extracted from the animal feed, cereal grain, or forage material with diethyl ether by the Randall method, also called the Soxtec method or the submersion method. The proposed submersion method considerably decreases the extraction time required to complete a batch of samples. The increase in throughput is very desirable in the quest for faster turnaround times and the greater efficiency in the use of labor. In addition, this method provides for reclamation of the solvent as a step of the method. The submersion method for fat extraction was previously studied for meat and meat products and was accepted as AOAC Official Method 991.36. Fourteen blind samples were sent to 12 collaborators in the United States, Sweden, Canada, and Germany. The within-laboratory relative standard deviation (repeatability) ranged from 1.09 to 9.26% for crude fat. Among-laboratory (including within) relative standard deviation (reproducibility) ranged from 1.0 to 21.0%. The method is recommended for Official First Action.  相似文献   

10.
A new kinetic photometric method for determination of carbimazole (CBZ) is described. The proposed method is simple, rapid, inexpensive and sensitive for the determination of CBZ in pure and tablet forms. This method is based on the inhibitory effect of carbimazole on the palladium(II)‐catalyzed reaction between neutral red (NR) and hypophosphite (HP) ions. The effect of various parameters such as dye, hypophosphite, and Pd(II) concentrations, pH, ionic strength, and temperature were optimized. The calibration graph was linear in the range 0.04–0.30 ppm (n = 9, r = 0.9972) and the detection limit was 0.02 ppm. The relative standard deviation of the developed method was 0.70% (n = 10). The proposed method was applied for the determination of carbimazole in pure and tablet forms.  相似文献   

11.
An on-line method was developed for the extraction, derivatization and determination of formaldehyde in textile samples. Formaldehyde was first extracted with water by ultrasound assisted, and directly introduced into a derivatization column which was packed with a moderately sulfonated cation-exchange resin. The resin used as solid support for the derivatization was charged with 2,4-dinitrophenylhydrazine (DNPH) previously. The formaldehyde DNPH derivative was eluted with the chromatographic mobile phase into an analytical column for the separation, and then monitored by UV detector. The maximum extraction yield was achieved when the extraction vessel was located at 10mm from the ultrasonic source and 10mg textile sample was extracted with 5mL pure water at a flow rate of 1.0mLmin(-1) at 50 degrees C. The detection limit of the proposed method was 0.06mgkg(-1). This method was applied to the determination of formaldehyde in different textile samples, and compared with the state standard method (off-line spectrophotometry) used in China. The similar contents of formaldehyde were obtained for most samples by the two methods, but little higher for some samples obtained by the proposed method. The average relative standard deviation (RSD) obtained by the on-line method was 3.2% which is lower than 29.5% obtained by the standard method.  相似文献   

12.
A direct ultra-performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) for simultaneous measurement of urinary 5-hydroxytryptophol glucuronide (GTOL) and 5-hydroxyindoleacetic acid (5-HIAA) was developed. The GTOL/5-HIAA ratio is used as an alcohol biomarker with clinical and forensic applications. The method involved dilution of the urine sample with deuterated analogues (internal standards), reversed-phase chromatography with gradient elution, electrospray ionisation and monitoring of two product ions per analyte in selected reaction monitoring mode. The measuring ranges were 6.7-10 000 nmol/l for GTOL and 0.07-100 micromol/l for 5-HIAA. The intra- and inter-assay imprecision, expressed as the coefficient of variation, was below 7%. Influence from ion suppression was noted for both compounds but was compensated for by the use of co-eluting internal standards. The accuracy in analytical recovery of added substance to urine samples was 96 and 98%, respectively, for GTOL and 5-HIAA. Method comparison with GC-MS for GTOL in 25 authentic patient samples confirmed the accuracy of the method with a median ratio between methods (GC-MS to UPLC-MS/MS) of 1.14 (r(2) = 0.975). The difference is explained by the fact that the GC-MS method also measures unconjugated 5-hydroxytryptophol naturally present in urine. The comparison with data for 5-HIAA obtained by an HPLC method demonstrated a median ratio of 1.05 between the methods. The UPLC-MS/MS method was capable of measuring endogenous GTOL and 5-HIAA levels in urine, which agreed with the literature data. In conclusion, a fully validated and robust direct method for the routine measurement of urinary GTOL and 5-HIAA was developed.  相似文献   

13.
A high-performance liquid chromatography-diode array detector (HPLC-DAD) method was developed and validated for the quantitation of dexibuprofen in dexibuprofen tablets using ovomucoid chiral stationary phase (Ultron ES-OVM). The mobile phasewas composed of 0.025 M potassium phosphate dibasic (pH 4.5)-methanol-ethanol (85:10:5 v/v/v). The method was validated for specificity, linearity, range, accuracy, precision and robustness. The method was enantiomerspecific for the determination of dexibuprofen [S-(+)-isomer ibuprofen] in the presence of R-(-)-isomer ibuprofen in bulk drug, pharmaceutical dosage form and under stress degradation. The method was linear over the range 15-35 mg/mL with r2 = 0.9995; accuracy and precision were acceptable with %RSD < 2.0%. The method was found to be specific, precise, accurate, robust and stability-indicating, and can be successfully applied for the routine analysis of dexibuprofen in bulk drug and pharmaceutical dosage form.  相似文献   

14.
徐广通  李德娥 《色谱》1997,15(6):550-552
研究了用高效液相色谱分析杀虫剂硫双灭多威的方法。在反相ODS柱上,用甲醇-水作流动相,紫外检测器检测,以邻苯二甲酸二甲酯作内标定量。方法快速、准确,重现性好,线性范围宽,变异系数为0.18%,回收率为99.89%,色谱分析周期仅为8min。  相似文献   

15.
A method for determining crude fat in animal feed, cereal grain, and forage (plant tissue) was collaboratively studied. Crude fat was extracted from the animal feed, cereal grain, or forage material with hexanes by the Randall method, also called the Soxtec method or the submersion method. The use of hexanes provides for an alternative to diethyl ether for fat extractions. The proposed submersion method considerably decreases the extraction time required to complete a batch of samples compared to Soxhlet. The increase in throughput is very desirable in the quest for faster turnaround times and the greater efficiency in the use of labor. In addition, this method provides for reclamation of the solvent as a step of the method. The submersion method for fat extraction was previously studied for meat and meat products and was accepted as AOAC Official Method 991.36. Fourteen blind samples were sent to 14 collaborators in the United States, Sweden, Canada, and Germany. The within-laboratory relative standard deviation (repeatability) ranged from 1.23 to 5.80% for crude fat. Among-laboratory (including within) relative standard deviation (reproducibility) ranged from 1.88 to 14.1%. The method is recommended for Official First Action.  相似文献   

16.
新型薄层色谱内标法测定葛根素含量   总被引:10,自引:0,他引:10  
以大豆甙元为内标物在高效硅胶薄层板上采用新型内标法测定了葛根素注射液、中药葛根及中成药玉泉丸中葛根素的含量,建立了新型TLC内标法测定葛根素的新方法。结果表明:用大豆甙元作为内标物测定葛根素可以满足TLC内标物的一般条件,新型TLC内标法测定葛根素的含量具有测定结果准确,精密度好,回收率高等优点。  相似文献   

17.
《Electroanalysis》2006,18(10):947-954
In this work, for the first time a fast continuous cyclic voltammetry was used as a highly sensitive detection method for Penicillin G in a flow‐injection system. A special computer‐based numerical calculation method (using Fast Fourier Transformation) is introduced here for enhancing the analyte signal and noise reduction. During the measurements, the potential waveform (consists of potential steps for cleaning, stripping and potential ramp) was continuously applied on an Au disk microelectrode (with a radius 12.5 μm in radius). The stripping time was less than 200 ms. Effects of rest potential, sweep rate, and delay time on the sensitivity of the method were investigated. The limit of detection of the method was 1.0 × 10?11 M. The detection limit of the method is 660 times lower than the most sensitive reported method. The relative standard deviation of the method at 1.0×10?7 M of Penicillin G was 2.7% for 10 runs.  相似文献   

18.
A stability‐indicating MEKC method was developed and validated for the simultaneous determination of aliskiren (ALI) and hydrochlorothiazide (HCTZ) in pharmaceutical formulations using ranitidine as an internal standard (IS). Optimal conditions for the separation of ALI, HCTZ and its major impurity chlorothiazide (CTZ), IS and degradation products were investigated. The method employed 47 mM Tris buffer and 47 mM anionic detergent SDS solution at pH 10.2 as the background electrolyte. MEKC method was performed on a fused‐silica capillary (40 cm) at 28°C. Applied voltage was 26 kV (positive polarity) and photodiode array (PDA) detector was set at 217 nm. The method was validated in accordance with the ICH requirements. The method was linear over the concentration range of 5–100 and 60–1200 μg/mL for HCTZ and ALI, respectively (r2>0.9997). The stability‐indicating capability of the method was established by enforced degradation studies combined with peak purity assessment using the PDA detection. Precision and accuracy evaluated by RSD were lower than 2%. The method proved to be robust by a fractional factorial design evaluation. The proposed MEKC method was successfully applied for the quantitative analysis of ALI and HCTZ both individually and in a combined dosage tablet formulation to support the quality control.  相似文献   

19.
A multiresidue method for screening of emerging contaminants in aquatic environments was developed. The method was based on sample pretreatment with solid phase extraction (SPE) and analysis with an ultra performance liquid chromatograph-time-of-flight mass spectrometer (UPLC-TOF-MS). The method was optimized and tested with standard solutions of model compounds containing 84 pesticides and pharmaceuticals. Four different SPE sorbents were evaluated to gain maximum recovery for the analytes. For the final procedure a combination of two different sorbents was chosen. In spite of high matrix suppression, the method quantification limits (MQLs) were acceptable. Therefore, the method can be used for screening known target compounds. The applicability of the method for posttarget and nontarget screening will be reported later. To preliminarily assess the quantitative performance of the method, some compounds in wastewater effluent were quantified using the standard addition method. Three pesticides and eight pharmaceuticals were found in concentrations up to ~2200 ng/L.  相似文献   

20.
Mast cell stabilizer and histamine receptor antagonist olopatadine hydrochloride (OPT) assay method predicated on LC have been established for the analysis in multiple formulations. The current method dealt with ophthalmic solution, nasal spray, and tablet formulation products. The isocratic chromatography method was optimized and validated with a Boston green C8 column (150 × 4.6 mm, 5 μm i.d.). Sodium dihydrogen phosphate buffer (pH 3.5) with acetonitrile in the ratio of 75:25 (v/v) was used as a mobile phase at a flow rate of 1.0 mL min−1 and at the column temperature of 30°C, and the detection was done at 299 nm. The method was validated as per International Council for Harmonisation (ICH) guidelines and United States Pharmacopoeia (USP). The accuracy results ranged from 99.9 to 100.7%, % relative standard deviation (RSD) from the precision was 0.5, and correlation coefficient from the linearity experiment was > 0.999. Solution stability was established for 24 h at room temperature and refrigerator conditions, and it was found that the solutions were stable. Using quality by design-based experiment designs, critical quality attributes were studied and it was found that the method was robust. In all the forced degradation studies peak purity was passed, and no interference was found at the retention time of the active component. The method validation data demonstrated that the developed method is linear, precise, accurate, specific, robust, and stable for the determination of OPT from multiple formulations. Analytical eco-scale tool, Green Analytical Procedure Index (GAPI) tool, and the National Environmental Method Index (NEMI) were used to evaluate the greenness of the method, and the analytical eco-score of 77 for the presented method was found to be excellent.  相似文献   