首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
The reaction of carbonate radical with phenol in aqueous solution has been investigated in systems in which carbonate radicals were generated by UV irradiation of an aqueous solution of [Co(NH3)5CO3]+ (pH 8.0 phosphate buffer). Both steady state and time resolved photolysis experiments were performed. Upon continuous irradiation of complex phenol mixtures, phenol was converted into benzoquinone and dihydroxybenzenes. Benzoquinone was the major by-product in the early stages of the reaction. Laser flash excitation (266 and 355 nm) of the cobalt complex clearly showed the formation of the carbonate radical. When phenol was added to the solution of the complex, a second species was observed which was assigned to the phenoxyl radical. The second-order rate constant of reaction between phenol and carbonate radical was found to be equal to 1.6 × 107 M−1 s−1, in agreement with literature data of 2.2 × 107 M−1 s−1.  相似文献   

2.
Present study deals with the adsorption of phenol on carbon rich bagasse fly ash (BFA) and activated carbon-commercial grade (ACC) and laboratory grade (ACL). BFA is a solid waste obtained from the particulate collection equipment attached to the flue gas line of the bagasse-fired boilers of cane sugar mills. Batch studies were performed to evaluate the influences of various experimental parameters like initial pH (pH0), contact time, adsorbent dose and initial concentration (C0) on the removal of phenol. C0 varied from 75 to 300 mg/l for the adsorption isotherm studies and the effect of temperature on adsorption. Optimum conditions for phenol removal were found to be pH0  6.5, adsorbent dose ≈10 g/l of solution and equilibrium time ≈5 h. Adsorption of phenol followed pseudo-second order kinetics with the initial sorption rate for adsorption on ACL being the highest followed by those on BFA and ACC. The effective diffusion coefficient of phenol is of the order of 10−10 m2/s. Equilibrium isotherms for the adsorption of phenol on BFA, ACC and ACL were analysed by Freundlich, Langmuir, Temkin, Redlich–Peterson, Radke–Prausnitz and Toth isotherm models using non-linear regression technique. Redlich–Peterson isotherm was found to best represent the data for phenol adsorption on all the adsorbents. The change in entropy (ΔS°) and heat of adsorption (ΔH°) for phenol adsorption on BFA were estimated as 1.8 MJ/kg K and 0.5 MJ/kg, respectively. The high negative value of change in Gibbs free energy (ΔG°) indicates the feasible and spontaneous adsorption of phenol on BFA. The values of isosteric heat of adsorption varied with the surface loading of phenol.  相似文献   

3.
The gamma radiolysis of aqueous benzene solutions was studied under various conditions (oxygenated, aerated and anoxic) to ascertain the role that oxygen plays in the destruction of benzene. For the oxygenated and aerated systems, phenol and biphenyl were the major quantified products. For the anoxic system, phenol was the sole quantified product. Benzene was initially consumed with approximately the same yield in each of the three systems; G(–benzene) was 0.49 μmol J–1. Initial yields of phenol, G(phenol), were found to be 0.12, 0.060 and 0.030 μmol J–1 for the oxygenated, aerated and anoxic systems, respectively. Biphenyl was initially formed with G=0.028 and 0.019 μmol J–1 in the oxygenated and aerated systems, respectively. The percent conversion of benzene to CO2 after an absorbed dose of 2500 kGy was 55.1%, 30.5% and 12.5%, respectively, for the oxygenated, aerated and anoxic systems. The last traces of benzene disappeared by a dose of ca. 60 kGy in all three systems. A mechanism was proposed for each system that depended upon the presence or absence of O2. The total solution toxicity for each system was calculated by summing the individual toxicities of benzene and each quantified product. For the oxygenated and aerated systems, the total solution toxicity was found to go through a maximum at a dose of 22 kGy and then decrease to a value below that of the original solution. The total solution toxicity of the anoxic system was found to decrease from the onset of irradiation.  相似文献   

4.
Upper critical solution temperatures (UCSTs) of (water + phenol) systems are reported with 0.1 mol · kg−1 halide salts, carboxylic acids, 1.0% PEG 200 in water, and 0.01 mol · kg−1 surfactants and polynuclear aromatic compounds namely benzene, naphthalene, anthracene, chrysene; and benzene derivatives namely toluene and xylene solutions in phenol. Valence electrons and shell numbers, basicity, –CH3 and –CH2–, hydrophilic, hydrophobic and π conjugated electrons of respective additives have been noted to affect their UCSTs and mutual solubilities. The surfactants decrease the USCTs with higher mutual solubilities due to effective hydrophilic as well as hydrophobic interactions with aqueous and organic phases, respectively. A stronger structure breaking action of 3(-OH) of glycerol outweighs those of the 3(-COO) and 1(-OH) of citric acid and urea does produce almost equal UCSTs as compared to glycerol. A decrease in UCSTs is noted with increasing number of conjugated π electrons of benzene, naphthalene, anthracene and chrysene. In general, dTc/dx2 values of salts for 0.20 to 0.16 mole fractions of phenol are found positive while for 0.055 to 0.052 mole fractions, the negative.  相似文献   

5.
This paper deals with the influence of the electron beam energy (E=1.2–3 MeV; I=20–125 μA; DR=1.3–8.3 kGy s−1) on the degradation of phenol in aqueous solution. The decomposition of phenol and the concentration of its principal by-products are significantly influenced by the energy of the electron beam. The degradation yield increases with the electron energy. A simplified phenomenologic model of the reactor was proposed to describe the results.  相似文献   

6.
Manganese(II) complex of (E)-2-(hydroxyl-5-methoxybenzylideneamino) phenol was synthesized and used as a suitable Mn(II) – selective membrane in PVC matrix. The plasticized membrane sensor exhibits a nersian response for Mn(II) ions over a wide concentration range of 6 × 10?6–2 × 10?2 M with slope of 29 ± 1 mV per decade. It has a response time of <11 s and can be used for 2 months without any measurable divergence in potential. The response of the proposed sensor is independent of pH between 4 and 9.5. The proposed sensor shows a fairly good discriminating ability towards Mn(II) in comparison with some hard and soft metals. The electrode was used in the determination of Mn(II) in aqueous solutions and as an indicator electrode in potentiometer titration of manganese ions against EDTA.  相似文献   

7.
In this paper we propose a specific sandwich immunoassay method for human-immunoglobulin G (HIgG). This immunoassay protocol takes advantage of sandwich binding of primary and secondary antibodies for increased specificity. Polystyrene microspheres (PS) serve as immobilizing support, site for sandwich immunoassay and then subsequently used for chemiluminescence (CL) detections. In this sandwich immunoassay, PS microspheres were modified with the primary anti-HIgG (Ab1) via electrostatic interaction, while CdTe nanoparticles (CdTeNPs) were modified with horseradish peroxidase labeled anti-HIgG (Ab2) via covalent binding. Antigen HIgG (Ag) was specifically captured by the first and secondary antibody and form sandwich immunoassay format. Combination of the remarkable sensitivity of CL method and the use of CdTe NPs as anti-HIgG–HRP carrier for the enzymatic signal amplification, provide a linear response range of HIgG from 0.01 to 300 ng mL−1 with an extremely low detection limit of 0.3 pg mL−1. This immunoassay system has many desirable merits including sensitivity, accuracy, and little required instrumentation. The assay results were compared with enzyme-linked immunosorbent assay (ELISA), and showed relatively good reliability. Significantly the new protocol may become quite promising technique for protein immune-detection as well as DNA analysis and other biological analyses.  相似文献   

8.
9.
《Tetrahedron letters》2014,55(51):6965-6968
The selective assay of cyanide ions with a thioamide compound (HNPTU) containing phenol and pyridine as a chemosensor is reported using absorbance changes in a buffered aqueous solution (50 mM HEPES, pH 7.4) containing ethanol. Upon treatment with cyanide ions, the colorless solution of HNPTU turned yellow. No significant changes were observed with other comparable anions, such as F, Cl, Br, I, and CH3COO. The color change of HNPTU upon treatment with CN was maintained even in the presence of the comparable monovalent anions. The complex stability constant (Ka = 2.6 × 103) for the stoichiometric 1:1 complexation of HNPTU with cyanide ions was obtained based on absorbance titrations. The interaction of HNPTU with cyanide ions was proposed to be deprotonation, as shown by NMR and Cu(II) treatment experiments.  相似文献   

10.
A series of diazenyl schiff bases have been synthesized by reaction of salicylaldehyde containing azo dyes with various substituted aniline derivatives in the presence of acetic acid as catalyst. The structures of diazenyl derivatives were determined by FTIR, UV–vis, 1H NMR, 13C NMR, CHN analysis, fluorimetric and mass spectroscopic studies. The synthesized derivatives were screened for their in vitro antimicrobial activity against various Gram-positive (S. aureus, B. subtilis, B. cereus), Gram-negative (S. typhi, S. enterica, E. coli, P. aeruginosa) bacterial and fungal (C. albicans, A. niger and A. fumigatus) strains, using cefadroxil (antibacterial) and fluconazole (antifungal) as standard drugs. The diazenyl schiff bases were also screened for their cytotoxicity against human colorectal carcinoma cell line (HCT-116) using 5-fluorouracil as standard drug by Sulforhodamine-B Stain (SRB) assay. The schiff bases exhibited significant activity toward both Gram-positive, Gram-negative bacterial and fungal strains. Most of the synthesized derivatives showed high activity against S. enterica. 4-((2,5-Dichlorophenyl)diazenyl)-2-((3-bromophenylimino)methyl)phenol (SBN-40) was found to be very active against S. aureus, B. cereus and E. coli, with MIC = 0.69 (µM/ml × 102). The compound 4-((2-bromophenyl)diazenyl)-2-((4-nitrophenylimino)methyl)phenol (SBN-13) possessed comparable activity (IC50 = 7.5 µg/ml) to the standard drug 5-fluorouracil (IC50 = 3.0 µg/ml) against human colorectal carcinoma cell line (HCT-116).  相似文献   

11.
In 0.2 mol/L HCl–0.22 mol/L HNO3 medium, trace Hg2+ catalyzed NaH2PO2 reduction of HAuCl4 to form gold nanoparticles (AuNPs), which exhibited a strong resonance Rayleigh scattering (RRS) effect at 370 nm. With increasing of [Hg2+], the RRS effect enhanced due to more AuNP generated from the catalytic reaction. Under the chosen conditions, the enhanced RRS intensity at 370 nm is linear to Hg2+ concentration in the range of 5.0–450 × 10−9 mol/L, with a detection limit of 0.1 nmol/L. This RRS method was applied for the determination of Hg in water samples, with high sensitivity and good selectivity, and its results were agreement with that of atomic fluorescence spectrometry.  相似文献   

12.
An automated solid phase extraction method by flow analysis on-line inductively coupled plasma mass spectrometry (FI-ICP-MS) for the determination of cobalt, chromium, nickel, cadmium, manganese, zinc, copper and lead in sea-water and other natural waters is described. The system is based on retention of the analytes onto a minicolumn packed with a chelating resin, 1,5-bis (2-pyridyl)-3-sulphophenyl methylene thiocarbonohydrazide immobilized on aminopropyl-controlled pore glass, placed in the injection valve of a simple flow manifold. The effects of chemical and flow variables were investigated and selected as a compromise between sensitivity and sampling frequency. So, the sample solutions (adjusted to pH 8.0 ± 0.5) were passed through the column. After washing the column with water, the adsorbed metals were subsequently eluted into the plasma with 4% m/m nitric acid. Detection limits of the trace metals (180 s sample loading time at a sample flow rate of 0.7 mL min? 1; sampling frequency 8.6 h? 1) were 0.002 μg L? 1 for Co, 0.057 μg L? 1 for Cr, 0.117 μg L? 1 for Ni, 0.004 μg L? 1 for Cd, 0.210 μg L? 1 for Mn, 0.260 μg L? 1 for Zn, 0.030 μg L? 1 for Cu and 0.020 μg L? 1 for Pb, with enrichment factors between 2.2 and 6.8. The accuracy of the proposed method was checked with certified reference materials (CRMs) of sea-water SLEW 3, LGC6016 and CASS-5, river water SLRS-5 and fortified lake water TMDA-54.4. The results from the determination of these metals were in agreement with the certified values and recovery values ranged between 92.2 and 110.6%. The method was applied to the determination of these metal ions in sea-water samples collected in the Málaga Bay in order to realize a pilot study necessary to generate preliminary information on which to base a more detailed pollution study by heavy metals of the Bay.  相似文献   

13.
A simple, sensitive, and cost-effective analytical method was developed for the speciation analysis of inorganic selenium by combining a nano-TiO2 preconcentration with an ion chromatography-conductivity detection (IC-CD) system. The experimental conditions for the simultaneous adsorption and desorption of Se(IV) and Se(VI) were carefully investigated. Under the established optimum condition, the Se(IV) and Se(VI) ions could been simultaneously adsorbed onto the nano-TiO2 surface at pH 4.0, and then effectively desorbed by 0.1 M sodium hydroxide eluent. The adsorption process was fast and reached adsorption equilibrium within 10 min. The nano-TiO2 also exhibited high adsorption capacity with 11.3 mg g? 1 for Se(IV) and 8.34 mg g? 1 for Se(VI). The enrichment factors for Se(IV) and Se(VI) were calculated to be 39 and 30, respectively, with sample volume of 50 mL. The detection limits (3σ) were 0.8 μg L? 1 for Se(IV) and 0.4 μg L? 1 for Se(VI), which were sensitive enough for the routine analysis of water and drink samples. The relative standard deviation was calculated to be < 4% (n = 6) for detection of 30 μg L? 1 Se(IV) and 30 μg L? 1 Se(VI). The results of the present work confirmed that our developed nano-TiO2-IC-CD method could be applied for the detection of inorganic selenium species in tap water and drink samples with good recoveries in the range of 82%–108%.  相似文献   

14.
Arsenic and germanium have been evaluated as internal standards to minimize matrix effects on the direct determination of selenium in milk by graphite furnace atomic absorption spectrometry (GFAAS) using tubes with integrated platform, pre-treated with W together with Pd as chemical modifier. The efficiency of As and Ge as internal standards for 25 μg L 1 Se plus 500 μg L 1 As or Ge in diluted (1 + 9 v/v) milk plus 1.0% (v/v) HNO3 was evaluated by means of correlation graphs plotted from the normalized absorbance signals (n = 20) of internal standard (axis y) versus analyte (axis x). The equations that describe the linear regression were: AAs =  0.004 ± 0.019 + 1.02 ± 0.019 ASe (r = 0.9967 ± 0.005); AGe =  0.017 ± 0.015 + 1.01 ± 0.015 ASe (r = 0.9978 ± 0.004). Samples and reference solutions were automatically spiked with 500 μg L 1 Ge or As and 1.0% (v/v) HNO3 by the autosampler. For 20 μL of aqueous standard solutions, analytical curves in the 5.00–40.0 μg L 1 Se range were established using the ratio of Se absorbance to internal standard absorbance (ASe / AIS) versus analyte concentration, and good linear correlations were obtained. The characteristic mass was 40 pg Se. Limits of detection were 0.55 and 0.40 μg L 1 with As and Ge as the internal standard, respectively. Relative standard deviations (RSD) for a sample containing 25 μg L 1 Se were 1.2% and 1.0% (n = 12) using As and Ge, respectively. The RSD without internal standardization was about 6%. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values were in the 99–105% range with IS and in the 70–80% range without IS. Using Ge as the internal standard, results of analysis of standard reference materials were in agreement with certified values at a 95% confidence level. The selenium concentration for 10 analyzed milk samples varied from 5.0 to 20 μg L 1.  相似文献   

15.
The energies of combustion for 2-nitrobenzenesulfonamide (cr), 3-nitrobenzenesulfonamide (cr), and 4-nitrobenzenesulfonamide (cr) were determined using a recently described rotating-bomb combustion calorimeter. The condensed phase molar energies of combustion obtained were ?(3479.2 ± 1.0) kJ · mol?1 for 2-nitrobenzenesulfonamide (cr), ?(3454.2 ± 1.1) kJ · mol-1 for 3-nitrobenzenesulfonamide (cr), and ?(3450.1 ± 1.9) kJ · mol-1 for 4-nitrobenzenesulfonamide (cr). From these combustion energy values, the standard molar enthalpies of formation in the condensed phase were obtained as: ?(341.3 ± 1.3) kJ · mol?1, ?(366.3 ± 1.3) kJ · mol?1, and ?(370.4 ± 2.1) kJ · mol?1, respectively. Polyethene bags were used as an auxiliary material in the combustion experiments. The heat capacities and purities of the compounds were determined using a differential scanning calorimeter.  相似文献   

16.
The behavior of a modified carbon platinum electrode (Pt) for lead(II) determination by square wave voltammetry (SWV) was studied. The modified electrode is obtained by electrodeposition of hydroxyapatite (HAP) on the surface of a bare platinum electrode. The new electrode (HAP/Pt) revealed interesting electroanalytical detection of lead(II) based on the adsorption of this metal onto hydroxyapatite under open circuit conditions. After optimization of the experimental and voltammetric conditions, the best voltammetric responses-current intensity and voltammetric profile were obtained in 0.2 mol L?1 KNO3 with: 30 min accumulation time, 5 mV pulse amplitude and 1 mV s?1 scan rate. The observed detection (DL, 3σ) and quantification (DL, 10σ) limits in pure water were 2.01 × 10?8 and 6.7 × 10?7 mol L?1, respectively. The reproducibility of the proposed method was determined from five different measurements in a solution containing 2.2 × 10?6 mol L?1 lead(II) with a coefficients of variation of 2.08%.The electrochemical of hydroxyapatite at platinum surfaces was characterized, after calcinations 900 °C, by X-ray diffraction, infrared spectroscopy, chemical and electrochemical analysis.  相似文献   

17.
Photooxidation of phenol sensitized by Aldrich humic acid (AHA) has been studied in an aqueous solution at neutral and basic pH. Solutions containing phenol and AHA of various concentrations were irradiated with monochromatic light at 253.7 nm or with polychromatic light within the wavelength range of 310–420 nm. The quantum yields of phenol photodegradation under these conditions were determined. At the wavelength of 253.7 nm direct degradation of phenol was much more effective than that sensitized by AHA. With polychromatic light the photooxidation was found to be strongly dependent on pH of aqueous solution and independent on AHA concentration.  相似文献   

18.
Electrochemical immunosensors based on single wall nanotube (SWNT) forests and 5 nm glutathione-protected gold nanoparticles (GSH-AuNP) were developed and compared for the measurement of human cancer biomarker interleukin-6 (IL-6) in serum. Detection was based on sandwich immunoassays using multiple (14–16) horseradish peroxidase labels conjugated to a secondary antibody. Performance was optimized by effective blocking of non-specific binding (NSB) of the labels using bovine serum albumin. The GSH-AuNP immunosensor gave a detection limit (DL) of 10 pg mL?1 IL-6 (500 amol mL?1) in 10 μL calf serum, which was 3-fold better than 30 pg mL?1 found for the SWNT forest immunosensor for the same assay protocol. The GSH-AuNPs platform also gave a much larger linear dynamic range (20–4000 pg mL?1) than the SWNT system (40–150 pg mL?1), but the SWNTs had 2-fold better sensitivity in the low pg mL?1 range.  相似文献   

19.
A highly sensitive, selective and rapid method for the determination of cobalt based on the rapid reaction of cobalt(II) with 5-(2-benzothiazolylazo)-8-hydroxyquinolene BTAHQ and the solid phase extraction of the Co(II)-BTAHQ complex with C18 membrane disks were developed. In the presence of pH = 6.4 buffer solution and cetylpyridenium chloride (CPC) medium, BTAHQ reacts with cobalt to form a deep violet complex with a molar ratio of 1:1 (cobalt to BTAHQ). This complex was enriched by the solid phase extraction with C18 membrane disks. An enrichment factor of 100 was obtained by elution of the complex from the disks with a minimal amount of isopentyl alcohol. In isopentyl alcohol medium, the molar absorptivity of the complex is 2.42 × 105 L mol−1 cm−1 at 658 nm. Beer’s law is obeyed in the range of 0.01–0.38 μg mL−1 in the measured solution. The relative standard deviation for 11 replicate samples of 0.20 μg mL−1 level is 1.37%. The detection and quantification limits reach 3.1 and 9.7 ng mL−1 in the original samples. This method was applied for the determination of cobalt in biological, water, soil and pharmaceutical preparation samples with good results.  相似文献   

20.
A new sorbent based on cysteine modified silica gel (SiG-cys) was prepared and studied for preconcentration and separation of noble metals Au(III), Pd(II), Pt(II), Pt(IV). Its extraction efficiency was examined by batch and column solid phase extraction procedures. Laboratory experiments performed showed that sorbent is characterized with high selectivity, permiting quantitative sorption (93–97%) of noble metals Au, Pd and Pt from acidic media 0.1–2 mol L? 1 HCl and unsignificant sorption (less than 2%) for common base metals like Cu, Fe, Mn and Zn. The analytes retained on the sorbent are effectively eluted with 0.1 mol L? 1 thiourea in 0.1 mol L? 1 HCl and measured by ETAAS or ICP OES under optimal instrumental parameters. The sorbent showed high mechanical and chemical stability and extraction efficiency was not changed after 500 cycles of sorption/desorption. The sorbent was successfully applied in analyticals procedures for preconcentration and determination of Au, Pd and Pt in geological and soil samples. Detection limits (3σ criteria) achieved, depending on the instrumental methods used are: ETAAS (0.005 μg L? 1 for Au in river and sea water, 0.002 μg g? 1 for Au in copper ore and copper concentrate); ICP OES (0.03 μg L? 1 for Pd and 0.06 μg L? 1 for Pt in river and sea water, 0.006 μg g? 1 for Pd in copper ore and copper concentrate and 0.002 μg g? 1 for soluble Pt in soil). The accuracy of the procedures developed was confirmed by added/found method for sea and river water; by the analysis of national certified materials (copper ore and copper concentrate for Au and Pd) and by determination of the sum of soluble Pt(II) + Pt(IV) in spiked soil samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号