首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Zhao S  Yuan H  Xiao D 《Electrophoresis》2006,27(2):461-467
A highly sensitive optical fiber light-emitting diode (LED)-induced fluorescence detector for CE has been constructed and evaluated. In this detector, a violet or blue LED was used as the excitation source and an optical fiber with 40 microm OD was used to transmit the excitation light. The upper end of the fiber was inserted into the separation capillary and was situated right at the detection window. Fluorescence emission was collected by a 40 x microscope objective, focused on a spatial filter, and passed through a cutoff filter before reaching the photomultiplier tube. Output signals were recorded and processed with a computer using in-house written software. The present CE/fluorescence detector deploys a simple and inexpensive optical system that requires only an LED as the light source. Its utility was successfully demonstrated by the separation and determination of amino acids (AAs) labeled with naphthalene-2,3-dicarboxaldehyde (NDA) and FITC. Low detection limits were obtained ranging from 17 to 23 nM for NDA-tagged AAs and 8 to 12 nM for FITC-labeled AAs (S/N=3). By virtue of such valuable features as low cost, convenience, and miniaturization, the presented detection scheme was proven to be attractive for sensitive fluorescence detection in CE.  相似文献   

2.
The potential of a recently developed lamp-based fluorescence detector for the analysis of underivatised proteins by capillary electrophoresis (CE) was investigated. Fluorescence detection (Flu) was achieved using optical light guides to deliver excitation light from a Xenon–Mercury lamp to the capillary detection window and to collect fluorescence emission and lead it to a photomultiplier. The performance of the detector was evaluated by monitoring the native fluorescence of the amino acid tryptophan and the proteins α-chymotrypsinogen A, carbonic anhydrase II, lysozyme and trypsinogen upon excitation at 280 nm. The test compounds were analysed using background electrolytes (BGEs) of sodium phosphate at pH 3.0 and 11.3. The results were compared to experiments of CE with UV absorbance detection. For tryptophan, a linear fluorescence response was obtained with a dynamic range of over 4 orders of magnitude, and a limit of detection (LOD) of 6.7 nM. This LOD was a factor of 200 more favourable than UV detection at 280 nm, and a factor of 20 better than detection at low-UV wavelengths. All tested proteins showed linear fluorescence responses up to 250 μg/mL. LODs were typically in the 10–20 nM range. These LODs were a factor of 25 lower than for UV detection at 280 nm, and comparable to UV detection at low-UV wavelengths. Overall, Flu yields much more stable baselines, especially with a BGE of high pH. The applicability of CE–Flu is demonstrated by the analysis of a degraded protein mixture, and of an expired formulation of the protein drug human growth hormone, indicating that protein degradation products can be selectively detected.  相似文献   

3.
Yang B  Tian H  Xu J  Guan Y 《Talanta》2006,69(4):996-1000
An integrated light emitting diode (LED)-induced fluorescence detector was described and evaluated. The LED and its related components including lens and interference filter, the optical fiber used to collect fluorescence, and the capillary column are integrated into a substrate block, which eliminates the need of align procedure of the fiber and the capillary. Forty-fold enhancement of sensitivity was obtained compared with our previous work and the detection limit for fluorescein was 5 nM. Application of the detector for the analysis of FITC-labeled Ephedrine extract was demonstrated.  相似文献   

4.
Yang B  Tan F  Guan Y 《Talanta》2005,65(5):1303-1306
A novel fluorescence detector based on collinear scheme using a brightness light-emitting diode emitting at 470 nm as excitation source is described. The detector is assembled by all-solid-state optical-electronic components and coupled with capillary electrophoresis using on-column detection mode. Fluorescein isothiocyanate (FITC) and FITC-labeled amino acids and small molecule peptide as test analyte were used to evaluate the detector. The concentration limit of detection for FITC-labeled phenylalanine was 10 nM at a signal-to-noise ratio (S/N) of 3. The system exhibited good linear responses in the range of 1 × 10−7 to 2 × 10−5 M (R2 = 0.999).  相似文献   

5.
We constructed a simple fluorescence detector for both direct and indirect CE methods using a blue light-emitted diode (470 nm) as excitation source, a bifurcated optical fiber as a waveguide, and a CCD camera as a detector. The connection of all the components is fairly easy even for nonexperts and the use of a CCD camera improves the applicability of this detector compared to the others using PMTs because it permits the recording of 2-D electropherograms or phosphorescence measurements. This detector provides a compact, low cost, and rapid system for the determination of native fluorescence compounds which have high quantum yields by CE with direct fluorescence detection, showing an LOD of 2.6 x 10(-6) M for fluorescein; the determination of fluorescence derivative compounds by CE with direct fluorescence detection, showing an LOD of 1.6 x 10(-7) M for FITC-labeled 1,6-diaminohexane; and nonfluorescence compounds by CE with indirect fluorescence detection with an LOD of 2.7 x 10(-6) M for gallic acid.  相似文献   

6.
Over the past few years, a large number of studies have been prepared that describe the analysis of peptides and proteins using capillary electrophoresis (CE) and laser-induced fluorescence (LIF). These studies have focused on two general goals: (i) development of automatic, selective and quick separation and detection of mixtures of peptides or proteins; (ii) generation of new methods of quantitation for very low concentrations (nm and subnanomolar) of peptides. These two goals are attained with the use of covalent labelling reactions using a variety of dyes that can be readily excited by the radiation from a commonly available laser or via the use of noncovalent labelling (immunoassay using a labelled antibody or antigen or noncovalent dye interactions). In this review article, we summarize the works which were performed for protein and peptide analysis via CE-LIF.  相似文献   

7.
For the first time, citrate-capped gold nanoparticles (citrate-AuNPs) have been used for the selective extraction of indoleamines – 5-hydroxytryptophan (5-HTP), tryptophan (Trp), tryptamine (TA), 5-hydroxytryptamine (5-HT), and 5-hydroxyindoleacetic acid (5-HIAA) – prior to their analysis by capillary electrophoresis/laser-induced native fluorescence (CE/LINF). The extinction spectra obtained for the citrate-AuNPs in the presence of indoleamines revealed that 5-HTP, 5-HT, and 5-HIAA were extracted mainly because of van der Waals interactions between the indole ring and the citrate-AuNPs (hydrophobic surface), while 5-HT and TA were extracted by electrostatic attractions between the amine group of the indoleamines and the citrate ligands adsorbed on the AuNP surface. The extracted indoleamines could be liberated from the AuNP surface by the addition of high concentrations of 2-mercaptoethanol (2-ME), which binds strongly to the AuNPs. The sensitivity of this method to indoleamines could be significantly enhanced by increasing the AuNP concentration, incubation time, and sample volume. Under optimal extraction and separation conditions, the combination of NP-based extraction and CE-LINF provided 48-, 4077-, 985-, 920-, and 4030-fold improvements in the limits of detection (signal-to-noise ratio of 3) for 5-HTP, Trp, TA, 5-HT, and 5-HIAA as compared to the analysis of five indoleamines by CE-LINF. In addition, this proposed method was successfully used for the determination of TA and 5-HT in urine.  相似文献   

8.
Capillary electrophoresis (CE) coupled with fiber-optic light-emitting diode-induced fluorescence detection has been developed for the separation of tyrosine (Tyr) enantiomers. R(−)-4-(3-isothiocyanatopyrrolidin-1-yl)-7-(N,N-dimethylaminosulfonyl)-2,1,3-benzoxadiazole was used as a chiral fluorescence tagged reagent for derivatization of Tyr. The effect of pH, running buffer concentration and applied voltage on enantioselectivity has been investigated. The optimum CE conditions are 15 mmol/L borate running buffer (pH 10.5) and 14-kV applied voltage. Good reproducibility was obtained with coefficient of variation (n = 7) of migration time and peak area less than 0.2 and 2.0%, respectively. The limits of detection of d- and l-Tyr derivatives were 2.9 and 2.2 μmol/L (S/N = 3), respectively. The proposed method has been successfully applied to the determination of Tyr in a commercial amino acid oral solution.  相似文献   

9.
Herein, we summarize the current status of native fluorescence detection in microchannel electrophoresis, with a strong focus on chip-based systems. Fluorescence detection is a powerful technique with unsurpassed sensitivity down to the single-molecule level. Accordingly fluorescence detection is attractive in combination with miniaturised separation techniques. A drawback is, however, the need to derivatize most analytes prior to analysis. This can often be circumvented by utilising excitation light in the UV spectral range in order to excite intrinsic fluorescence. As sensitive absorbance detection is challenging in chip-based systems, deep-UV fluorescence detection is currently one of the most general optical detection techniques in microchip electrophoresis, which is especially attractive for the detection of unlabelled proteins. This review gives an overview of research on native fluorescence detection in capillary (CE) and microchip electrophoresis (MCE) between 1998 and 2008. It discusses material aspects of native fluorescence detection and the instrumentation used, with particular focus on the detector design. Newer developments, featured techniques, and their prospects in the future are also included. In the last section, applications in bioanalysis, drug determination, and environmental analysis are reviewed with regard to limits of detection.  相似文献   

10.
Serotonin or 5-hydroxytryptamine (5-HT) is a major neurotransmitter in the central nervous system. In this work, a method for analyzing 5-HT in brain microdialysis samples using a commercially available capillary electrophoresis (CE) system has been developed. A pH-mediated in-capillary preconcentration of samples was performed, and after separation by capillary zone electrophoresis, native fluorescence of 5-HT was detected by a 266 nm solid-state laser. The separation conditions for the analysis of 5-HT in standard solutions and microdialysates have been optimized, and this method has been validated on both pharmacological and analytical bases. Separation of 5-HT was performed using a 80 mmol/L citrate buffer, pH 2.5, containing 20 mmol/L hydroxypropyl-beta-cyclodextrin (HP-beta-CD) and +30 kV voltage. The detection limit was 2.5 x 10(-10) mol/L. This method allows the in vivo brain monitoring of 5-HT using a simple, accurate CE measurement in underivatized microdialysis samples.  相似文献   

11.
The combination of capillary electrophoresis (CE) and light-emitting diode-induced fluorescence (LED-IF) detection has been demonstrated in the analysis of major amino acids in tea leaves and beverages. The separation efficiency of amino acids, which were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA), depended on the capillary length and PEO concentration. We suggested that the interactions between the NDA derivatives and poly(ethylene oxide) (PEO) molecules are based on hydrogen bonding, hydrophobic patches, and Van der Waals forces. The magnitude of EOF and the interactions between them can be further controlled by the capillary length. The separation of 17 NDA-amino acids derivatives was completed within 16 min using 0.5% PEO and 60 cm capillary length. The relative standard deviations (R.S.D.) of their migration times (n = 5) were less than 2.7%. Additionally, the limits of detection at signal-to-noise ratio 3 for the tested amino acids ranged from 3.6 to 28.3 nM. Quantitative determination of amino acids in tea leaves and beverages was accomplished by our proposed method. This study showed that amino acid present in highest concentration in tea leaves and beverages is γ-aminobutyric acid and theanine, respectively. The experimental results suggest that our proposed methods have great potential in the investigation of the biofunction of different tea samples.  相似文献   

12.
Kuo IT  Huang YF  Chang HT 《Electrophoresis》2005,26(13):2643-2651
This paper describes the analysis of biologically active amines by capillary electrophoresis (CE) in conjunction with laser-induced native fluorescence detection. In order to simultaneously analyze amines and acids as well as to achieve high sensitivity, 10 mM formic acid solutions (pH < 4.0) containing silica nanoparticles (SiNPs) were chosen as the background electrolytes. With increasing SiNP concentration, the migration times for seven analytes decrease as a result of increase in electroosmotic flow (EOF) and decrease in their electrophoretic mobilities against EOF. A small EOF generated at pH 3.0 reveals adsorption of SiNPs on the deactivated capillary wall. The decreases in electrophoretic mobilities with increasing SiNP concentration up to 0.3x indicate the interactions between the analytes and the SiNPs. Having a great sensitivity (the limits of detection at a signal-to-noise ratio (S/N) = 3 of 0.09 nM for tryptamine (TA)), high efficiency, and excellent reproducibility (less than 2.4% of the migration times), this developed method has been applied to the analysis of urinal samples with the concentrations of 0.50 +/- 0.02 microM, 0.49 +/- 0.04 microM, and 74 +/- 2 microM for TA, 5-hydroxytryptamine, and tryptophan, respectively. The successful examples demonstrated in this study open up a possibility of using functional nanoparticles for the separation of different analytes by CE.  相似文献   

13.
Hsieh MM  Chang HT 《Electrophoresis》2005,26(1):187-195
On-line concentration and separation of biologically active amines and acids by capillary electrophoresis (CE) in conjunction with laser-induced fluorescence using an Nd:YAG laser at 266 nm under discontinuous conditions is presented. The suitable conditions for simultaneous analysis of amines and acids were: samples were prepared in a solution (pH* 3.1) consisting of 10 mM citric acid, 89% acetonitrile (ACN), and water; a capillary was filled with 1.5 M Tris-borate (TB) buffer (pH 10.0); and the anodic vial contained PTG10 buffer (pH* 9.0) that consists of 50 mM propanoic acid, Tris, 10% glycerol, and water. After injecting a large-volume sample, amines and acids were separately stacked at the front (cathodic side) and back (anodic side) of the acidic sample zone, mainly because of changes in their electrophoretic mobilities as a result of changes in pH, viscosity, and electric field when high voltage was applied. When the sample was injected at 15 kV for 360 s, the concentration limits of detection (LODs) for 5-hydroxytryptamine (5-HT) and 5-hydroxyindole-3-acetic acid (5-HIAA) were 0.27 and 0.31 nM, respectively, which are about 400- and 800-fold sensitivity improvements when compared to those injected at 1 kV for 10 s. For the analysis of amines, samples were prepared in 100 mM citric acid (pH* 1.8) containing 89% ACN and both the capillary and anodic vial were filled with 400 mM PTG20 (propanoic acid, Tris, 20% glycerol, and water) at pH* 4.5. Using a large injection volume (15 kV for 360 s), we achieved concentration LODs of 17 pM and 0.3 nM for tryptamine and epinephrine, which are about 5200- and 14,000-fold sensitivity improvements, respectively, in comparison with those injected at 1 kV for 10 s. The features of simplicity (no sample pretreatment), rapidity (12 min), and sensitivity for identification of amines and acids of interest in urine samples show diagnostic potential of the two approaches developed in this study.  相似文献   

14.
p-Nitroaniline was explored as a derivatising reagent for UV absorbance detection of carbohydrates after separation by CE. This derivatising agent has three advantages: first, it has excellent water solubility; second, it has high molar absorptivity; and third, it is possible to obtain sensitive detection using a UV or blue light-emitting diode (LED) as the light source. The labelling reaction took less than 30 min to complete with high reaction yield. The separation process was modelled and optimised using an artificial neural network. Nine carbohydrates were separated by a CE system within 16 min using a 0.17 M boric acid buffer at pH 9.7. On-column LED detection at 406 nm allowed the detection of carbohydrates with good detection limits (<1.1 microM or 8.8 fmol) and reproducible quantification in the concentration range of 2.6-200 microM. This method was applied successfully to the determination of component carbohydrates in some food samples.  相似文献   

15.
Py-1 and Py-6 are novel amino-reactive fluorescent reagents. The names given to them reflect that they consist of a pyrylium group attached to small aromatic moieties. Upon reaction with a primary amine there is a large spectral shift in the reagent, rendering them effectively fluorogenic. In this study, these reagents were used to label a test protein, (human serum albumin), and the sample was analyzed by capillary electrophoresis and laser-induced fluorescence detection. Detection limits after a 60 min labeling reaction at 22 degrees C (Py-1) and 50 degrees C (Py-6) were 6.5 ng/mL (98 pM) for Py-1 and 1.2 ng/mL (18 pM) for Py-6. Separation of immunoglobulin G (IgG), human serum albumin, lipase, and myoglobin after labeling with Py-6 were performed. The method was further modified to make it amenable to automation. Unlike many other amino reactive reagents used to label protein amino groups, reaction with Py-1 and Py-6 do not alter the charge of the protein and the advantage of this with respect to electrophoretic separations is discussed.  相似文献   

16.
The potential of CE with native fluorescence detection (Flu) for the profiling of the therapeutic protein erythropoietin (EPO) was studied. EPO is a highly heterogeneous glycoprotein comprising a large number of isoforms. CE was applied to induce separation among the various glycoforms. Native Flu of EPO provided high detection selectivity yielding good signal‐to‐noise ratios and stable baselines, particularly when compared to conventional UV absorbance detection. In order to enhance EPO isoform resolution, CE was performed using a capillary with a neutral coating in combination with a simple BGE of 2.0 M acetic acid (pH 2.1). CE‐Flu analysis of the EPO biological reference preparation of the European Pharmacopeia resulted in a highly detailed glycoform profile. Migration time RSDs for selected EPO isoforms were less than 0.22% and 0.80% for intraday and interday repeatability, respectively. RSDs for relative peak intensity of the major EPO isoforms were less than 3%. The achieved resolution, migration time stability, and sensitivity allowed discrimination of different EPO products (EPO‐α and EPO‐β) based on the recorded glycoform pattern. The developed CE‐Flu method is relatively straightforward, and shows potential for quality control in biopharmaceutical production.  相似文献   

17.
Indirect LIF detection was applied to the detection of four acidic diuretics separated by CZE. Semiconductor laser was employed to provide the stable excitation of 473 nm. With an optimized electrophoretic buffer system which contained 5 mM of triethylamine, 0.1 microM of fluorescein, and 5% of n-butanol, fast separation of four diuretics (ethacrynic acid, chlorthalidone, bendroflumethiazide, and bumetanide) can be performed within 3 min with the detection limits of 0.2-2 microg/mL. The impacts of buffer components including the concentrations of the electrolytes, fluorescence probe, and the organic additives were demonstrated. The method was applied for the detection of diuretics in urine. As an alternative way for the fast analysis of diuretics, this indirect detection method provided the technical support for future microchip performances, in which diuretics may be detected in the microchip by the common LIF detector without derivatization.  相似文献   

18.
19.
We describe the stacking and separation of d- and l-aspartic acid (Asp) by capillary electrophoresis (CE) with light-emitting diode-induced fluorescence detection (LEDIF). In the presence of cyanide, d- and l-Asp were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) to form fluorescent derivatives prior to CE-LEDIF. The separation of NDA-derivatized d- and l-Asp was accomplished using a discontinuous system - buffer vials contained a solution of 0.6% poly(ethylene oxide) (PEO), 150 mM sodium dodecyl sulfate (SDS), and 60 mM hydroxypropyl-β-cyclodextrin (Hp-β-CD), while a capillary was filled with a solution of 150 mM SDS and 60 mM Hp-β-CD. The role of PEO, Hp-β-CD, and SDS is to act as a concentrating media, as a chiral selector, and as a pseudostationary phase, respectively. This discontinuous system could be employed for the stacking of 600 nL of NDA-derivatized d- and l-Asp without the loss of chiral resolution. The stacking mechanism is mainly based on the difference in viscosity between sample zone and PEO as well as SDS sweeping. The limits of detection at signal-to-noise of 3 for d- and l-Asp were down to 2.4 and 2.5 × 10−10 M, respectively. Compared to normal sample injection volume (25 nL), this stacking approach provided a 100- and 110-fold improvement in the sensitivity of d- and l-Asp, respectively. This method was further applied for determining d- and l-Asp in cerebrospinal fluid, soymilk, and beer.  相似文献   

20.
毛细管电泳荧光检测模式的研究进展   总被引:1,自引:0,他引:1  
毛细管电泳技术由于具有分析速度快、分离效率高、样品用量少、操作简单、抗污染能力强等特点,广泛的应用于环境监测、临床检验、生物样品分析等领域.荧光检测技术的引入使毛细管电泳在保持强大的分离能力的同时具有了较高的检测灵敏度.本文介绍了影响毛细管电泳-荧光检测灵敏度的两个重要因素(光源和检测模式),对目前常用的两种光源(激光和发光二极管)以及三种检测模式的光路结构(正交型、共线型和嵌入式光纤传导-柱内直接激发型)的设计进行了相应地比较.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏