首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An existing RP-HPLC method for the measurement of the major bovine whey proteins in bovine whey samples and powders has been extended to include the analysis of the minor bovine whey protein lactoferrin. Lactoferrin could be detected and quantitated at levels down to 0.2 microg and linear calibration was observed between 0.2 and 30 microg. Reliable quantitation of lactoferrin in whey samples could be achieved provided the bovine serum albumin to lactoferrin ratio did not exceed 10:1. Quantitative data obtained by the RP-HPLC method compared favourably with data obtained by Mono S analytical chromatography.  相似文献   

2.
The separation of the four major whey proteins by sodium dodecyl sulphate (SDS)-capillary gel electrophoresis (CGE) is described. Whilst commercially purified whey proteins could be analysed using the recommended protocol, the more complex nature of an acid whey and a reconstituted whey protein concentrate (WPC) powder necessitated considerable refinement of the CGE sample buffer. Individual whey proteins in the acid whey and WPC samples were then also separated and quantitated using capillary zone electrophoresis, polyacrylamide gel electrophoresis (PAGE) and HPLC methods and the results were compared. The values obtained for -lactalbumin (-Lac) and β-lactoglobulin (β-Lg) were consistent throughout the various methods, although size-exclusion HPLC, SDS-PAGE and SDS-CGE could not separate the two β-Lg variants or the glycosylated form of -Lac from the β-Lg. There was considerable variation in the values for the bovine serum albumin and immunoglobulin determined by the different methods and it was concluded that none of the methods could satisfactorily quantitate all four whey proteins.  相似文献   

3.
1-Anilinonaphthalene-8-sulfonic acid (1,8-ANS), 4,4'-dianilino-1,1'-binaphthyl-5,5'-disulfonic acid (bis-ANS) and 2-(p-toluidino)naphthalene-6-sulfonic acid (2,6-TNS) were evaluated as additives in different buffers for the detection of bovine whey proteins using laser-induced fluorescence (LIF) monitoring in capillary electrophoresis (CE). These N-arylaminonaphthalene sulfonates furnish a large fluorescence emission when associated to some proteins whereas their emission in aqueous buffers, such as those used in CE separations, is very small. To select the best detection conditions, the fluorescence of these probes was first compared using experiments carried out in a fluorescence spectrophotometer. Using bovine serum albumin (BSA) as a model protein, it was demonstrated that 2-(N-cyclohexylamino)ethanesulfonic acid (CHES) buffer (pH 8 and pH 10.2) and the fluorescent probe 2,6-TNS gave rise to the highest increase in fluorescence for BSA. When the composition of these separation buffers was optimized for the electrophoretic separations, CHES buffer, pH 10.2 was chosen as the most suitable buffer to detect bovine whey proteins. The limit of detection obtained for some whey proteins in CE separations was about 6.10(-8) M for BSA, 3.10(-7) M for beta-lactoglobulin A (beta-LGA), 3.10(-7) M for beta-lactoglobulin B (beta-LGB), and 3.10(-6) M for alpha-lactalbumin (alpha-LA). These detection limits were compared to those achieved using UV detection under the same separation conditions. The results showed that the detection limits of BSA, beta-LGA and beta-LGB were twice as good using LIF than with UV detection. However, the limit of detection for alpha-LA was better when UV was used. The applicability of LIF detection to CE separation of whey proteins in bovine milk samples was also demonstrated.  相似文献   

4.
We have developed a novel, high-throughput approach for molecular mass determination of proteins from 14 200 to 116 000 based upon multiplexed, absorbance-based capillary electrophoresis. Via capillary multiplexing, 96 samples were analyzed simultaneously within 30 min. Detection with ultraviolet light obviates the need for protein staining or derivatization. The detection limit of the system was estimated at 5 microg/ml bovine serum albumin (BSA) when sampled from 12.5 mM Tris-HCl. The linear dynamic range was over two orders of magnitude from 5 microg/ml to 1000 microg/ml for BSA. Better than 5% sizing accuracy for protein molecular mass determination and excellent run-to-run and day-to-day reproducibility was obtainable with the described method.  相似文献   

5.
We present a simple protocol for affinity depletion to remove the two most abundant serum proteins, albumin and immunoglobulin G (IgG). Under native conditions, albumin/IgG were efficiently removed and several proteins were enriched as shown by two-dimensional electrophoresis (2-DE). Besides that, partly denaturing conditions were established by adding 5 or 20% acetonitrile (ACN) in order to disrupt the binding of low-molecular-weight (LMW) proteins to the carrier proteins albumin/IgG. 2-DE results showed that the total number of detected LMW proteins increased under denaturing conditions when compared to native conditions. Interestingly, the presence of 5% ACN in serum revealed better enrichment of LMW proteins when compared to 20% ACN condition. Seven randomly distributed spots in albumin/IgG depleted serum samples under 5% ACN condition were picked from the 2-DE gels and identified by mass spectrometry (MS). The intensity of five LMW protein spots increased under denaturing conditions when compared to native conditions. Three of the seven identified spots (serum amyloid P, vitamin D-binding protein, and transthyretin) belong to a group of relatively low-abundant proteins, which make up only 1% of all serum proteins. The method presented here improves the resolution of the serum proteome by increasing the number of visualized spots on 2-D gels and allowing the detection and MS identification of LMW proteins and proteins of lower abundance.  相似文献   

6.
Li Q  Chen X  Zhang H  Xue C  Liu S  Hu Z 《The Analyst》2000,125(8):1483-1486
A new Rayleigh light scattering (RLS) assay of protein is presented in this paper. At the optimum pH 4.10, the weak RLS of Arsenazo-DBN can be greatly enhanced by the addition of proteins due to the interaction between protein and Arsenazo-DBN. Based on this, the reactions of Arsenazo-DBN and proteins, including bovine serum albumin, human serum album, gamma-globulin, egg albumin, lysozyme and trypsin, were studied. A new quantitative determination method for proteins has been developed. The linear range for human serum albumin, for example, is 0.085-34.62 micrograms mL-1 with a detection limit of 44.8 ng mL-1. Besides high sensitivity, the method is characterized by good reproducibility, rapidity of reaction, good stability, and few interfering substances. The determination of the proteins in human serum and urine samples by this method give results very close to those obtained using Coomassie Brilliant Blue G-250 colorimetry, with relative standard deviations of 0.7-2.5%.  相似文献   

7.
刘保生  高静  杨更亮 《分析化学》2005,33(4):546-548
研究了吖啶橙(AO)与罗丹明6G(R6G)之间能量转移的最佳条件。在pH=7.20的Tirs-HCl缓冲溶液,十二烷基苯磺酸钠介质中,AO-R6G能够发生有效能量转移,使R6G荧光增强。蛋白质的加入使R6G荧光猝灭,以此建立了利用AO-R6G荧光共振能量转移间接测定蛋白质的新方法。牛血清白蛋白、人血清白蛋白工作曲线线性范围分别为1.0~31和1.0—30mg/L;检出限分别为0.32和0.33mg/L;平行6次测定相对标准偏差为1.1%~2.0%;回收率为96.7%~103.2%。此方法的稳定性好,选择性高,用于人血清试样中总蛋白含量的测定,与常用的双缩脲法基本一致。  相似文献   

8.
在pH 3.0~3.8的BR缓冲溶液中,偶氮胂Ⅲ-Ba(Ⅱ)与蛋白质结合形成复合物,导致体系的共振散射信号增强,据此建立了蛋白质测定的共振散射光谱法。结果表明,在优化的实验条件下,牛血清白蛋白(BSA)的线性范围为0~1.0 mg/L,检出限为21.4μg/L;将该法用于人血清中蛋白质的测定,与医院测定结果基本一致;方法的批内精密度为2.8%(n=6),批间精密度为3.5%(n=6),回收率为96.0%~100.0%。  相似文献   

9.
Proteins ranging in molecular mass from 14,000 to 80,000 were analyzed by reversed-phase high-performance liquid chromatography-electrospray mass spectrometry (RP-HPLC-ESI-MS) using 60 x 1.0 mm I.D. microbore-columns packed with 2.3 microns highly crosslinked, octadecylated poly(styrene-divinylbenzene) particles. Proteins were eluted at temperatures of 80-90 degrees C with gradients of acetonitrile in 0.10-0.50% aqueous solutions of trifluoroacetic acid, formic acid or acetic acid. Substitution of trifluoroacetic acid, the most commonly used mobile phase additive for RP-HPLC, by formic acid resulted in a 35-160-fold improvement in analyte detectability at the cost of an only 32-104% increase in peak width at half height of eluting chromatographic peaks. The lower limits of detection for carbonic anhydrase (M(r) 29,022.7) in full scan and selected ion monitoring mode were 37 and 2.3 fmol, respectively. Measurement of protein masses by RP-HPLC-ESI-MS was accurate and highly reproducible with maximum mass deviations of 0.025% and relative standard deviations of less than 0.011%. Calibration plots of peak area versus concentration allowed the reliable quantitation of proteins in a concentration range of 0.010-1.0 mg/ml. Finally, the optimized method was applied to the separation, identification and quantification of proteins in real samples such as commercial protein preparations, monoclonal antibody fragments, allergen extracts and whey drinks.  相似文献   

10.
A new hydrophobic charge‐induction chromatography resin was prepared with 5‐aminobenzimidazol as functional ligand and polyacrylic ester beads as matrix. Adsorption isotherms and adsorption in columns were investigated using human immunoglobulin G and bovine serum albumin as model proteins, and the influence of pH and NaCl concentration was discussed. Results showed that the ligand density was 195 μmol/mL gel, and protein selectivity can be improved by controlling pH and salt addition. An optimized purification process (sample loading at pH 8.0 with 0.2 M NaCl and elution at pH 5.0) was performed to purify human immunoglobulin G from bovine serum albumin containing feedstock, which resulted in human immunoglobulin G purity of 99.7% and recovery of 94.6%. A similar process was applied for the purification of monoclonal antibody from cell culture supernatant, which showed antibody purity of 94.9% and recovery of 92.5%. The results indicated that the new resin developed had comparable performance as Protein A chromatography and would be suitable for antibody purification from complex feedstock.  相似文献   

11.
Efficient separation and enrichment of low‐abundance glycopeptides from complex biological samples is the key to the discovery of disease biomarkers. In this work, a new material was prepared by coating copper tetra(N‐carbonylacrylic) aminephthalocyanine and iminodiacetic acid onto poly(glycidyl methacrylate‐pentaerythritol triacrylate) monolith. The monolith was applied to polymer monolithic microextraction for specific capture of glycopeptides coupled with matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry. The developed monolith exhibited satisfactory efficiency for glycopeptide enrichment with high selectivity and detection sensitivity. When the tryptic digest of immunoglobulin G was used as the sample, total 24 glycopeptides were identified and the detection limit was determined as 5 fmol. When the approach was applied to the analysis of glycopeptides in the mixture of bovine serum albumin and immunoglobulin G (100:1, m/m) digests, 16 glycopeptides could still be observed. Moreover, the monolith was successfully applied to the selective enrichment of glycopeptides from human serum digests, exhibiting great practicability in identifying low‐abundance glycopeptides in complex biological samples.  相似文献   

12.
On-line coupling between CIEF and ESI/MS based on the use of bare fused-silica capillaries and glycerol-water media, recently developed in our laboratory, has been investigated for the separation of milk whey proteins that present close pI values. First, a new rinsing procedure, compatible with MS detection, has been developed to desorb these rather hydrophobic proteins (α-casein (α-CN), bovine serum albumin (BSA), lactoferrin (LF)) from the inner capillary wall and to avoid capillary blockages. Common hydrochloric acid washing solution was replaced by a multi-step sequence based on the use of TFA, ammonia and ethanol. To achieve the separation of major whey proteins (β-lactoglobulin A (β-LG A), β-lactoglobulin B (β-LG B), α-lactalbumin (α-LA) and BSA, which possess close pI values (4.5-5.35), CIEF parameters i.e. carrier ampholyte nature, capillary partial filling length with ampholyte/protein mixture and focusing time, have been optimized with respect to total analysis time, sensitivity and precision on pI determination. After optimization of sheath liquid composition (80:20 (v/v) methanol-water+1% HCOOH), quantitation of β-LG A, β-LG B, α-LA and BSA was performed. The limits of detection obtained from extracted ion current (EIC) and single ion monitoring (SIM) modes were in the 57-136 nM and 11-68 nM range, respectively. Finally, first results obtained from biological samples demonstrated the suitability of CIEF-MS as a potential alternative methodology to 2D-PAGE to diagnose milk protein allergies.  相似文献   

13.
A new RP-HPLC method for the separation and quantification of the most common genetic variants of bovine milk proteins is described. A reversed-phase analytical column C8 (Zorbax 300SB-C8 RP, 3.5 microm, 300A, 150 x 4.6 I.D.) was used. All the most common casein (CN) and whey protein genetic variants, including beta-CN(I) were detected and separated simultaneously in less then 40 min, with the exception of alpha(S1)-CN(B) and CN(C) variants. Purified protein genetic variants were employed in calibration and showed different absorbances at 214 nm. The procedure was developed using 40 raw individual milk samples of cows belonging to four different breeds and certified skim milk powder BCR-063R. Method validation consisted in testing linearity, repeatability, reproducibility and accuracy. A linear relationship (R(2)>0.99) between the concentrations of proteins and peak areas was observed over the concentration range, with low detection limits. Repeatability and reproducibility were satisfactory for both retention times and peak areas. The RSD of peak areas ranged from 0.92 to 4.32% within analytical day and from 0.85 to 9.52% across analytical days. The recoveries, calculated using mixtures of samples previously quantified, ranged from 98.1 to 103.7%.  相似文献   

14.
We report the multiplexed, simultaneous analysis of antigen–antibody interactions that involve human immunoglobulin G (IgG) on a gold substrate by the surface plasmon resonance imaging method. A multichannel, microfluidic chip was fabricated from poly(dimethylsiloxane) (PDMS) to selectively functionalize the surface and deliver the analyte solutions. The sensing interface was constructed using avidin as a linker layer between the surface-bound biotinylated bovine serum albumin and biotinylated anti-human IgG antibodies. Four mouse anti-human IgG antibodies were selected for evaluation and the screening was achieved by simultaneously monitoring protein–protein interactions under identical conditions. Antibody–antigen binding affinities towards human immunoglobulin were quantitatively compared by employing Langmuir adsorption isotherms for the analysis of SPRi responses obtained under equilibrium conditions. We were able to identify two IgG samples with higher affinities towards the target, and the determined binding kinetics falls within the typical range of values reported in the literature. Direct measurement of proteins in serum samples by SPR imaging was achieved by developing methods to minimize nonspecific adsorption onto the avidin-functionalized surface, and a limit of detection (LOD) of 6.7 nM IgG was obtained for the treated serum samples. The combination of SPR imaging and multichannel PDMS chips offers convenience and flexibility for sensitive and label-free measurement of protein–protein interactions in complex conditions and enables high-throughput screening of pharmaceutically significant molecules. Figure Microchannel SPR imaging for protein–protein interactions  相似文献   

15.
A method for the determination of zeranol and its metabolite beta-zearalanol in bovine urine is described. It has been applied to samples from calves given multiple subcutaneous doses of zeranol. Samples were extracted with immunoaffinity columns containing antibodies raised against zeranol and were analysed by gas chromatography-mass spectrometry. The immunoaffinity columns were prepared by coupling immunoglobulin G fractions obtained from rabbit antisera with a Sepharose matrix. The immunizing agent was carboxybutylzeranol coupled to bovine serum albumin. Gas chromatography-mass spectrometry was performed in the negative-ion chemical ionization mode, after derivatization of the compounds to their pentafluorobenzyl ethers, and allowed detection of analytes with a sensitivity of 0.01 ppb in spiked urine. The derivatization method and the gas chromatographic determination were also applied to the similar compounds zearalanone, zearalenone and beta-zearalenol. A synthesis of dideuterated zeranol and beta-zearalanol by isotopic exchange is described. These deuterated analogues had an isotopic purity of more than 99% and were used for quantitation of zeranol and beta-zearalanol by isotope dilution mass spectrometry. The recoveries of zeranol and beta-zearalanol, using the immunoaffinity columns, were determined after extraction from spiked urine and were 84 and 64%, respectively. The urines of treated calves were collected for several days after treatments and were analysed after hydrolysis with beta-glucuronidase and arylsulphatase. The samples showed variable but generally decreasing concentrations of zeranol and beta-zearalanol. The levels of beta-zearalanol ranged from less than 0.01 to 98 ppb and were 1.2-3.2 times higher than those of zeranol.  相似文献   

16.
The manganese-tetrasulfonatophthalocyanine (MnTSPc) catalyzed luminol-hydrogen peroxide chemiluminescence (CL) systems can be quenched in the presence of proteins. A highly sensitive CL quenching method has been developed for the determination of proteins. Under optimum conditions, the linear ranges of the calibration curves were 0.1-20 microg/mL for human serum albumin (HSA), 0.2-20 microg/mL for human gamma-IgG, and 0.5-50 microg/mL for the bovine serum albumin (BSA) with the corresponding detection limits were 1.9 ng/mL, 2.7 ng/mL, and 3.4 ng/mL. The method has been applied to the analysis of total proteins in human serum samples and the results were in good agreement with clinical data provided.  相似文献   

17.
We identified several low-abundance proteins of bovine colostrum and mature milk using the immunoabsorption technique and two-dimensional electrophoresis (2-DE) followed by microsequencing and mass spectrometry. Two major milk proteins, beta-casein and immunoglobulin G (IgG), were effectively removed from the milk using immunoabsorbents. Milk samples before and after immunoabsorption were separated by 2-DE. Protein identification of the spots on 2-DE was performed by either gel comparison, microsequencing, matrix-assisted laser desorption/ionization-time of flight mass-spectrometry (MALDI-TOF-MS), peptide mass fingerprinting or peptide sequencing using tandem MS by hybrid quadrupole/orthogonal acceleration time of flight-MS (Q-TOF). Significant differences in protein patterns were observed between the low-abundance proteins of colostrum and mature milk. In addition, several low-abundance proteins including fibrinogen beta-chain, chitinase 3-like 1, alpha-antitrypsin, complement C3 alpha-chain, gelsolin and apolipoprotein H were observed only in colostrum. However, the level of beta-casein fragments increased significantly during this lactation period. alpha-Lactalbumin and beta-lactoglobulin as well as some low-abundance proteins including bovine serum albumin, serotransferrin and lactoferrin were identified in both colostral and mature milk. Low-abundance proteins in bovine colostrum may have special physiologic relevance to the health and development of calves early in lactation.  相似文献   

18.
We have used a surface plasmon resonance biosensor (SPR, BIACORE 2000) to detect antibodies against glucose 6-phosphate isomerase (GPI) in synovial fluids of rheumatoid arthritis (RA) and osteoarthritis (OA). Recombinant human GPI proteins fused with or without NusA were expressed in E. coli, purified to homogeneity and immobilized in flow cells of CM5 sensor chips. The flow cells immobilized with NusA protein or bovine serum albumin were used to monitor non-specific binding. Synovial fluid samples from RA patients showed a significantly higher level of binding to recombinant GPI proteins than samples from OA patients. Proteins which bound to the recombinant GPI proteins were confirmed to be immunoglobulin through the administration of anti-human immunoglobulin. NusA fusion protein was excellent for this assay because of a low background binding activity in the SPR analysis and its advantage of increased solubility in recombinant protein production. These results suggested a useful utilization of recombinant NusA-GPI fusion protein for the detection of autoantibodies against GPI in RA patients.  相似文献   

19.
This study describes the synthesis of molecularly imprinted polymers (MIPs) using bovine albumin as a template, 2-VP as a functional monomer, EGDMA as a cross-linker and AIBN as an initiator by radical polymerization. Non-imprinted polymers (NIPs) were prepared and treated with the same method, but in the absence of bovine albumin. The synthesized MIPs and NIPs were characterized on the basis of FTIR, TGA and DTA. An adsorption process (solid phase extraction, SPE) for the removal of bovine albumin using the fabricated MIPs and NIPs was evaluated under various conditions. Effective parameters on bovine albumin retention for example, pH, flow rate, nature of the eluent, the ionic strength, selectivity coefficient, and retention capacity were studied. Competition test implicates that the MIP adsorbents have the strongest specific retention and enrichment for bovine albumin respect to NIPs. The maximum adsorption of bovine albumin by the fabricated MIPs was 24 mg/g. The calibration curves were linear in the range of 20–200 mg/L of bovine albumin. The limit of detection (LOD), the calibration sensitivity, the relative standard deviation (RSD) and preconcentration factor under optimal experimental conditions were 2.44 and 25, respectively. The extraction of bovine albumin from blood serum, urine, whey and milk samples had a selectivity and enrichment property. In the actual experiment for real samples, recovery of ~ 80% was achieved.  相似文献   

20.
p‐Aminohippuric acid is a newly developed ligand for mixed‐mode chromatography with a commercial resin name of Nuvia cPrime. In this study, bovine immunoglobulin G and bovine serum albumin were used as two model proteins, and the adsorption isotherms with Nuvia cPrime were investigated under different pH and salt concentrations. The results showed that pH had a strong but different influence on the adsorption of these two proteins. The adsorption capacity for bovine immunoglobulin G and BSA was 170.4 and 28.1 mg/g at pH 6.0, respectively. Different salts also showed varying effects on the protein adsorption. Moreover, the adsorption and elution behaviors of the two proteins in a column were determined under varying pH and salt concentrations. An optimized process showed that feedstock loaded under pH 6.0 with 0.8 M (NH4)2SO4 and eluted under pH 8.0 with 1.0 M NaCl could effectively purify bovine immunoglobulin G from feedstock containing BSA. The purity of bovine immunoglobulin G could reach 99.8% and the recovery was 92.7%. The results demonstrated that the control of pH and salt addition during the loading and elution processes were two key factors in improving separation efficiency with Nuvia cPrime resin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号