首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A spectrophotometric flow-injection procedure is described for the determination of sulphate in sodium hydroxide solutions. Sulphate catalyses the reaction between zirconium and methylthymol blue to form a complex measured at 586 nm. Optimal reaction conditions are discussed. The calibration graph is linear over the range 0.05–0.5 g l?1 sulphate with a relative standard deviation of 0.02. The sample throughput is 20 h?1. Sulphate is easily determined in 1 M sodium hydroxide; the results agree with those obtained by the conventional gravimetric method and by ion chromatography.  相似文献   

2.
A flow injection configuration is suggested for the simultaneous determination of ammonia and hydrazine at the μg ml?1 level by formation of zones of different pH. The analytes react with o-phthalaldehyde and mercaptoethanol to form fluorescent derivatives at different pH values. In addition to the normal flow method, a stopped flow method is proposed to increase the ranges that can be quantified. The analysis of samples containing hydrazine and ammonia in ratios between 0.3 and 70.0 is described.  相似文献   

3.
Summary A simple, modified, automated method for the turbidimetric determination of sulphate in surface, ground and domestic water, based on the principles of the flow-injection technique, is described. The one loop of a two-position sampling valve is used to sample an alkaline buffer-EDTA solution, alternated with water samples on the other loop. This ensures that the residual precipitate, coating the walls of the flowcell, is redissolved and the system kept clean. The method is suitable for the analysis of sulphate at a rate of up to 60 samples per hour with a coefficient of variation of better than 0.95 %.
Automatisierte turbidimetrische Bestimmung von Sulfat in OberflÄchen-, Grundund Leitungswasser mit Hilfe der Flie\-Injektions-Analyse
Zusammenfassung Eine automatisierte einfache Modifikation der turbidimetrischen Sulfatbestimmung in OberflÄchen-, Grund- und Leitungswasser mit Hilfe der Flie\-Injektion wird beschrieben. Dabei wird die eine Schleife eines Zweierventils zur Entnahme einer alkalischen EDTA-Pufferlösung, die andere Schleife damit abwechselnd für die Wasserproben verwendet. Dadurch wird ein Niederschlag, der sich an den WÄnden der Durchflu\zelle ansetzt, aufgelöst und somit das System sauber gehalten. Das Verfahren eignet sich zur Sulfatanalyse mit einer Geschwindigkeit von 60 Proben je Stunde bei einem Variationskoeffizient von <0,95%.
  相似文献   

4.
Meneses SR  Maniasso N  Zagatto EA 《Talanta》2005,65(5):1313-1317
A flow-injection procedure for spectrophotometric determination of sulphate in soil solutions is proposed. Samples are directly soaked from the soils under field conditions, in-line filtered through ceramic plates, and preserved with thymol. The method involves reaction with barium dimethylsulphonazo(III) (DMSA) in the presence of dimethylsulphoxide (DMSO) with further measuring the decrease in absorbance at 668 nm. A linear response is observed up to about 5 mgl −1 SO4, and detection limit (3σ criterion) is 0.1 mg l−1 SO4. Only 4.5 μg DMSA is consumed per determination. The system is rugged and baseline drift is not observed during extended operation periods. About 60 samples are injected per hour, and the results are precise (r.s.d. <2%) and in agreement with ion chromatography.  相似文献   

5.
Summary Sulphate was determined in natural water samples by flow-injection analysis using dimethylsulphonazo-III as reagent. The interference by Ca was eliminated by a cation-exchanger column inserted directly after the sample injection valve. In order to ensure high sensitivity and reproducibility it was necessary to saturate the carrier solution with barium sulphate and to fill the reaction coil with ethanol-water (11) when not in use. Standard deviations were 0.94–1.2% for 6–10mg/l sulphate. The limit of detection was about 0.2mg/l. The calibration graph was linear up to 14mg/l Mg2+, NH 4 + , Na+, K+, Cl, NO 3 , PO 4 3– , HCO 3 and SiO 3 2– did not interfere in the normally occurring concentrations.
Sulfatbestimmung in natürlichem Wasser durch Flow-Injection-Analyse
Zusammenfassung Als Reagens dient Dimethylsulfonazo-III. Die Störung durch Calcium bei dieser Bestimmung wird durch eine Kationenaustauschersäule eliminiert, die direkt nach dem Probeinjektions-Ventil angeordnet ist. Zur Erhöhung der Empfindlichkeit und Reproduzierbarkeit ist es notwendig, die Trägerlösung mit Bariumsulfat zu sättigen sowie bei Nichtbenutzung des Systems den Reaktionsteil mit Ethanol-Wasser (11) zu füllen. Mit dem so modifizierten Verfahren ergaben sich Standardabweichungen von 0,94–1,2% für 6–10 mg/l Sulfat, die Nachweisgrenze liegt bei 0,2 mg/l. Die Eichkurve ist bis 14 mg/l linear. Mg2+, NH 4 + , Na+, K+, Cl, NO 3 , PO 4 3– , HCO 3 und SiO 3 2– stören in den normalerweise vorkommenden Konzentrationen nicht.
  相似文献   

6.
Two methods for the determination of iron by normal FIA and reversed FIA were developed using sodium 3-(2-pyridyl)-5,6-diphenyl-1,2,4-triazine-4',4'-disulphonate (ferrozine). The reagent formed a chelate with Fe(II) in hexamethylentetramine buffered medium at pH 5.5. In one previous reaction coil Fe(III) was reduced to Fe(II) by ascorbic acid and in the other reaction coil the complexation reaction was developed. The linear range of the determination was 0.5-6 and 0.1-5 mug ml(-1) of iron for normal FIA and reversed FIA respectively. The proposed method was sensitive (detection limit 0.012 and 0.010 mug ml(-1)), rapid and reproducible (RSD 0.3 and 0.28%). The method was satisfactorily applied to the determination of iron in waste water, toadstool tissue, potato leaves, human hair and bauxites at a sampling rate of 90 and 50 samples h(-1) for normal FIA and reversed FIA respectively.  相似文献   

7.
A flow-injection Spectrophotometric method for the determination of adrenaline and isoprenaline, based on the reaction with metaperiodate, is described. The calibration graphs are linear up to 2 × 10−4 M. Flow injection allows the measurement of 120 samples per hour. The method was successfully applied to the determination of both catecholamines in pharmaceuticals.  相似文献   

8.
Summary A fast and inexpensive fluorimetric method for the determination of total aflatoxins (B1, B2, G1, and G2) in food of use in screening numerous samples suspectedly containing these substances is proposed. The sensitivity of the method (determination range between 0.5 and 200.0 ng ml–1) allows these analytes to be detected at concentrations well below legal limits; hence, separation-detection techniques such as HPLC need only be used with samples in which these compounds are found to occur. The method has been applied to maize, peanut and tapioca samples, obtaining average recoveries of 100.9 with deviations of ±5% with respect to 100% recovery.
Fluorometrische Bestimmung von Aflatoxinen durch Fließinjektionsanalyse
  相似文献   

9.
A sensitive, rapid and simple flow injection procedure for the determination of diphenhydramine has been designed based on a fluorometric approach. An aqueous solution of diphenhydramine is injected into a carrierreagent stream containing Ce(IV) in dilute sulphuric acid and the fluorescence intensity of the Ce(III) produced is monitored. Chemical, FIA and instrumental variables were optimized. Analytical features of the method are: linear range 0.2–2 ppm, precision 0.7%, sample throughput 80/h. The influence of some foreign substances which can be found in typical pharmaceutical samples containing diphenhydramine was also investigated. The diphenhydramine content of a pharmaceutical preparation was determined.  相似文献   

10.
A spectrophotometric flow-injection method for the determination of silicate based on the formation of an ion pair between molybdosilicic acid and Rhodamine B is proposed. It allows silicate to be determined over the concentration range 0.17–2.0 mg 1?1 at a sampling rate of 40 h?1, is reasonably precise and is highly tolerant to ions that commonly occur in waters. It has been applied with satisfactory results to the determination of silicate in various types of water.  相似文献   

11.
Andrade MG  Ferreira SL  Santos BF  Costa AC 《Talanta》1992,39(10):1229-1232
A flow-injection method has been developed for the sequential spectrophotometric determination of iron and titanium using 3,4 dihydroxybenzoic acid as chromogenic reagent. The system involves the sequential measurement of the absorbances of the complexes at 380 and 570 nm. The system is designed using a simultaneous injection of sample and reagent into separate carrier streams. The proposed method is characterized by a precision of about 2%, a sampling rate of about 50 samples per hour, and a reagent consumption of 200 mul (0.50% solution) per sample. It is relatively free of interferences and was used for the sequential determination of titanium and iron in rocks.  相似文献   

12.
基于没食子酸与铬 (Ⅵ )的氧化还原反应 ,产生的铬 (Ⅲ )催化鲁米诺 H2 O2 化学发光体系的研究 ,结合流动注射技术 ,优化反应条件 ,建立了一种高灵敏度的快速测定没食子酸的新方法。方法的线性范围为 2 .0× 1 0 - 9~ 5 .0× 1 0 - 6g/mL ,检出限为 1 .2× 1 0 - 9g/mL ,对 1 .0× 1 0 - 7g/mL的没食子酸进行了 1 1次平行测定 ,相对标准偏差为 2 .1 %。方法成功地用于健民咽喉片中没食子酸的测定。  相似文献   

13.
An enzymatic flow-injection procedure for the determination of -lysine was developed. A lysine oxidase reactor is combined with a fibre-optic hydrogen peroxide detector. Hydrogen peroxide detection is based on the peroxidase-catalysed luminol reaction. The chemiluminescent light is detected by a photomultiplier. -Lysine can be determined in the range 10–1000 μM. A sampling rate of up to 90 h can be achieved. The whole sensing assay works for more than 1 month. The double logarithmic graph of the peak signal height vs. the lysine concentration is linear, the slope being larger than unity (r2 = 0.991, n = 4).  相似文献   

14.
A FIA indirect spectrophotometric determination of ascorbic acid was developed using its reducing action on Fe(III) in acidic medium and following the spectrophotometric determination of the reduced iron by using sodium 3-(2-pyridyl)-5,6-diphenyl-1,2,4-triazine-4',4'-disulphonate (ferrozine) as chromogenic reagent in buffered medium (pH 5.5) and monitoring the absorbance signal at 562 nm. A three-line manifold with two reaction coils was used: in the first reaction coil, ascorbic acid reduces Fe(III) to Fe(II); and in the second one, the complexation reaction is developed. The linear range of the method was 0.5-10 mug ml(-1) of ascorbic acid, the detection limit being 0.028 mug ml(-1). The proposed method was sensitive, rapid (sampling rate of 90 samples h(-1)) and reproducible (RSD 0.19%, n=10). Satisfactory results were obtained in the determination of ascorbic acid in pharmaceutical preparations, fruit juices and urine testifying the applicability of the method to real samples.  相似文献   

15.
Summary A catalytic-fluorimetric method is presented for the simultaneous determination of copper(II) and mercury(II) based on their catalytic effects on the oxidation of dipyridyldiketone phenylhydrazone and 2,2-dipyridylketone hydrazone, respectively, using the FIA/ stopped-flow mode. The errors in the determination of these cations are less than 10%, with a sampling rate of 45 samples per hour and the r.s.d. is 0.91% and 1.6% for Cu(II) and for Hg(II), respectively.
Simultane katalytisch-fluorimetrische Bestimmung von Kupfer und Quecksilber durch Flow-Injection-Analyse
Zusammenfassung Mit Hilfe der FIA/stopped-flow-Technik wurde eine Simultanbestimmung von Cu(II) und Hg(II) durchgeführt, die auf der katalytischen Wirkung dieser Elemente auf die Oxidation von Dipyridyldiketon-phenylhydrazon bzw. 2,2-Dipyridylketon-hydrazon beruht. Die Fehler sind geringer als 10% mit einem Probendurchsatz von 45 Proben je Stunde. Die relative Standardabweichung beträgt 0,91% für Cu und 1,6% für Hg.
  相似文献   

16.
An automatic direct spectrophotometric method for the simultaneous determination of nitrite and nitrate by flow-injection analysis has been developed. Nitrite reacts with 3-nitroaniline in the presence of hydrochloric acid (0.96-1.8 M HCl or pH 0.5-0.7) to form a diazonium cation, which is subsequently coupled with N-(1-naphthyl)-ethylenediamine dihydrochloride to form a stable purple azo dye, the absorbance of which is measured at 535 nm. Nitrate is reduced on-line to nitrite in a copper-coated cadmium column which is then treated with azo dye reagent and the absorbance due to the sum of nitrite and nitrate is measured; nitrate is determined from the difference in absorbance values. A copper column incorporated into the reaction manifold before the copperised cadmium column not only improves the long-term accuracy, but also extends the life time of the copperised cadmium column. Various analytical parameters, such as effect of acidity (pH), flow rate, sample size, dispersion coefficient, time, temperature, reagent concentration and interfering species, were studied. The calibration graphs were rectilinear for 0.1-3.5 mug ml(-1) of NO(3) and 10 ng ml(-1)-2.2mug ml(-1) of NO(2). The method is successfully applied to some food samples (meat, flour and cheese), environmental waters (inland and surface), beer and soil samples. Up to 30 samples can be analysed per hour with a relative precision of approximately 0.1-2%.  相似文献   

17.
A spectrophotometric flow-injection procedure for the determination of sulphite in aqueous media over the range 0.5–20 mg 1?1 is described. The reagent used was the organic disulphide 5,5′-dithiobis(2-nitrobenzoic acid). Results are presented for a laboratory-based method for sulphite in water and a potential on-line method for sulphite in high ionic strength potassium chloride brine. The general attractions of flow-injection-based monitors for the on-line analysis of liquid process streams are also discussed.  相似文献   

18.
Kuroda R  Ida I  Kimura H 《Talanta》1985,32(5):353-357
A flow-injection spectrophotometric method has been developed for the accurate, continuous determination of silicon in silicate rocks. A rock sample solution is prepared by fusion with a 1:1 mixture of lithium carbonate and boric acid and subsequent dissolution of the cake in 1 M hydrochloric acid. The preparation technique is the same as that used for the determination of total iron, aluminium, calcium, titanium, and phosphorus in silicate rocks by flow-injection spectrophotometry. Because of the marked polymerization of silicic acid in acid solution, silicic acid is depolymerized in alkaline medium after a simple cation-exchange column filtration of the rock sample solution and then determined by a static or an FIA spectrophotometric method. The FIA system consists of two channels which carry the carrier solution and molybdate reagent, and allows the colour reaction to proceed under controlled conditions. The FIA system permits high throughput of 70 samples per hour. The procedure has been applied to a variety of standard silicate rocks of the U.S. Geological Survey and the Geological Survey of Japan, and gave satisfactory agreement with the recommended values.  相似文献   

19.
Zhao S  Xia X  Yu G  Yang B 《Talanta》1998,46(5):845-850
A flow-injection method for the simultaneous determination of iron and zinc in the human hair with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) using a pH gradient technique has been developed. The linear range for the determination of iron is 0.1 approximately 1.8 mug ml(-1) and for zinc is 0.2 approximately 5.0 mug ml(-1). About 20 approximately 30 samples can be determined in 1 h. The proposed method is simple, rapid and accurate. It has been applied to the simultaneous determination of trace amounts of iron and zinc in the human hair with satisfactory results.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏