首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An instrumental neutron activation analysis technique has been developed for the determination of As, Au, Ba, Co, Cr, Fe, Hf, Sb, Ta, Th, U, W and Zn in large (10–15 g) geological samples using in-pool irradiation with a SLOWPOKE-2 reactor. The technique allows for the simultaneous irradiation of multiple samples using a neutron flux of between 4·1013 and 8·1013 n·m–2·s–1. The detection limits obtained using the analytical methodology described in this paper are acceptable for exploration geochemistry and the technique has been used to analyze samples collected as part of a metallic minerals survey of Jamaica.  相似文献   

2.
Fast neutron activation analysis technique was applied for the determination of Si, Al, Ti, Fe and Zr in glass sand rock samples. The samples and standards were irradiated with a mono-energetic neutron flux of 108n · cm · s–1. Pneumatic facility was used. The gamma activities from samples and standards were counted using a 30 cm3 Ge(Li) detector, with FWHM of 2.9 keV at 1.332 MeV, coupled to an on-line computer facility.  相似文献   

3.
A prompt gamma neutron activation analysis (PGAA) setup installed at ANRTC has been used to analyze boron. It consists of a 22.6% REGe detector and a 740 GBq 241Am-Be neutron source moderated with water and paraffin. At the sample irradiation position, the thermal neutron fluence rate measured was 2.36·104 n·m–2· s–1 and the corresponding Cd-ratio was 22 for gold monitor. The absolute detection efficiency in the range of 120–1500 keV was determined using 152Eu standard solution. The sensitivity and detection limit for standard boric acid samples has been determined. The boron content in boric acid prepared from Turkish borate ores is measured to be 15.91±0.46% wt.  相似文献   

4.
A prompt gamma neutron activation analysis (PGAA) setup installed at ANRTC has been used to analyze boron. It consists of a 22.6% REGe detector and a 740 GBq 241Am-Be neutron source moderated with water and paraffin. At the sample irradiation position, the thermal neutron fluence rate measured was 2.36·104 n·m–2· s–1 and the corresponding Cd-ratio was 22 for gold monitor. The absolute detection efficiency in the range of 120–1500 keV was determined using 152Eu standard solution. The sensitivity and detection limit for standard boric acid samples has been determined. The boron content in boric acid prepared from Turkish borate ores is measured to be 15.91±0.46% wt.  相似文献   

5.
A method is described for determining impurities in Zr-2 and Zr-4 clads by means of instrumental neutron activation analysis followed by high resolution gamma-ray spectrometry. The samples were irradiated in IRT-5000 using vertical channels and a pneumatic system with neutron fluxes of about 3·1013 and 4.8·1011 n·cm–2·s–1, respectively, and counted using Ge(Li) detectors coupled to an on-line computer. The following impurties have been determined Al, Cr, Mn, Fe, Co, Ni, As, Sn, Sb, Hf and W.  相似文献   

6.
Concentrations of Al, Br, Ca, Ce, Co, Cr, Eu, Fe, Hf, La, Lu, Mg, Mn, Na, Rb, Sc, Sm, Sr, Tb, Th, Ti, V, Yb, Zn, and Zr have been measured in Tigris and Euphrates river water, using neutron activation analysis in combination with preconcentration technique. River water samples were preconcentrated by evaporation at 70°C under atmospheric pressure. The samples with standard reference materials were irradiated with a neutron flux of 2.3·1013 n·cm–2·s–1.  相似文献   

7.
Elemental profiles of brain tumor tissues from 15 patients of astrocytomas (grade I–III) and normal human brain tissues of 23 male age matched autopsies as controls have been studied by instrumental neutron activation analysis. The SLOWPOKE reactor with a thermal neutron flux of 8·1011n·cm–2·s–1 and swimming pool type reactor with a thermal neutron flux of 1·1013n·cm–2·s–1 were used for short and long irradiation of samples, respectively. Spectrophotometry was only used for analyzing phosphorus. A total of 18 elements Se, Na, K, Br, Cl, Mn, Mg, S, Ca, Cu, Hg, Cr, Fe, Rb, Zn, Co, Sc and P has been determined for this purpose. The reliability of methods has been checked by analyzing biological standard reference materials horse kidney (IAEA H-8) and bovine liver (NBS SRM 1577a). The analytical results showed that compared with the normal brain tissues, concentrations of Ca, Fe, Cu, Zn, Se, Mn, Br and Sc were significantly higher in tumor tissues (P<0.01) and concentrations of Rb, K and P were lower, while no differences for contents of Mg, S, Cr, Hg, Na and Cl were observed. A negative correlation between P and Ca in malignant and normal brain tissues was observed.  相似文献   

8.
Second-order neutron activation becomes a serious interference in NAA determinations of REE in submilligram samples of meteoritic and terrestrial materials when neutron fluences reach levels of 1020 n·cm–2 or more. The Dy-interference to Ho determination and the Eu-interference to Gd determination are quite, large. We discuss the importance of second-order activation interferences in REE determinations, and present an experimental method to correct the Dy-interference to Ho determination by INAA. Ho concentrations in splits of less than 0.2 mg of BCR-1 and SP can be accurately determined by INAA with a neutron fluence of 2·1020 n·cm–2 in spite of large Dy interferences of up to 200%. It is necessary for NAA determinations of REE with high neutron fluences that each REE standard be separated from its neighboring REE, in order to correct the second-order activation interferences experimentally.  相似文献   

9.
The trace elements content of Cola acuminata and three varieties of Cola nitida have been determined using neutron activation analysis. The samples have been irradiated at the Joint Universities Research Reactor, Risley, England for 71/2 hours in a neutron flux of 2.5·1012 n·cm–2s–1 and analysed using high resolution lithium drifted germanium detector coupled to a Canberra 35 microprocessor as a 4096 channel gamma spectrometer. The elements: Na, K, Br, W, Fe, Cs, Co, Zn, and Sc were detected.  相似文献   

10.
To identify and improve the analytical technique for air pollution research, four kinds of environmental standard samples, i.e., airbome particulate matter, coal flyash, soil and pine needle supplied from the NIST and the IAEA were analyzed using thermal and epithermal neutron activation techniques. Sample irradiation was done at the irradiation facilities (neutron flux, 1 · 1013 n·cm–2·s–1) of the TRIGA MARK-III Research Reactor in the Korea Atomic Energy Research Institute. The accuracy and precision for the analysis of 40 trace and toxic elements in the samples were compared with the certified and reported values, respectively. In the analytical results of all standard reference materials, the relative standard deviation were within the 15% except for 11 elements and the relative error were agreed within the 10–20% except for 13 elements. The benefit of epithermal activation was investigated and the optimum analytical condition is reported.  相似文献   

11.
This work describes a nuclear facility forin vivo prompt gamma activation analysis (IVPGAA) using a moderated neutron beam from a 0.1 W Tsing-Hua Mobile Educational Reactor (THMER). The IVPGAA measurement is a new technique for toxic cadmium determination in organs, which can efficiently be used in clinical diagnosis. The low-power nuclear reactor provides a total neutron flux of 3.3·104 n·cm–2·s–1 on the surface of the central vertical neutron beam tube to which a liquid phantom is positioned. The capability of such partial-body irradiation facility is demonstrated. The detection limit of cadmium in the left kidney for a skin dose equivalent of 1.66 mSv (166 mrem) was 1.34 mg in a 500-s irradiation/counting period, and the sensitivity in the left kidney was 103 counts mg–1·mSv–1. The performance of IVPGAA system using the THMER nuclear facility therefore has the advantages of mobility and feasibility with high sensitivity under low neutron and gamma doses.  相似文献   

12.
In the last years Cf-252 neutron sources will be incresingly used for nuclear analytical purposes. In the Central Institute of Isotope and Radiation Research, Leipzig, an irradiation equipment with a 3mg252Cf neutron source was constructed. It reaches thermal neutron fluxes of about 107 n·cm–2·s–1. The construction of this equipment and the different moderation geometries are described. Possibilities of the application for neutron induced autoradiography, neutron radiography and neutron activation analysis are demonstrated on examples.  相似文献   

13.
24 male autopsy cases aged 35–60 years have been collected from Shanghai China to study the relationships between human hair and internal tissues. Autopsy samples of hair, kidney-cortex, liver and lung were analyzed. A radiochemical neutron activation analysis (RNAA) based on a simple group extraction scheme was used for measuring the trace elements As, Cd, Hg, Cu and Zn. Zinc diethyldithiocarbamate Zn(DDC)2 and methly isobutyl ketone-iodide have been chosen as reagent. Trace element of Se was determined by instrumental neutron activation analysis (INAA). A SLOWPOKE reactor with a thermal neutron flux of 8·1011 n·cm–2·s–1 and a swimming pool type reactor with a thermal neutron flux of 1·1013 n·cm–2·s–1 were used for short and long irradiation of samples, respectively. The reliability of methods has been checked by analyzing biological standard reference materials Horse Kidney (IAEA H8), Tomato Leaves (NBS 1573) and Human Hair (NIES-5). The analytical results show that toxic elements As, Cd and Hg exist in a larger individual variability than the essential elements of Cu, Se and Zn for each tissue. A linear regression analysis related to the six elements of primary interest for the IAEA Coordinated Research Program (CRP) has been done by a computer program for each pair of hair-tissue. A positive correlation is found between concentration of As in hair and kidney-cortex, the correlation coefficient r is 0.751 (p<0.01). Positive correlations between concentration of Se in hair and liver, kidney-cortex and lung are also observed in this study. It shows that the elements As and Se in hair may be useful indicators for assessing certain internal tissues of normal persons. A comparison of Cd concentration in lung shows a significant difference between smokers and non-smokers. A significant correlation between element Cd and Zn in kidney-cortex is also presented in this paper.  相似文献   

14.
This work describes the design, fabrication, and testing of a lucite bodied proportional gas detection system for the analysis of boron in selected samples via detection of the charged particles produced in the 10B(n,)7Li reaction induced by thermal neutrons. The detector was designed for internal placement of samples; the sample types of major interest were airborne aerosols collected on filters or particulate impaction plates. Samples were irradiated with the detector in the thermal neutron field produced in the graphite thermal column of the University of Lowell's one megawatt research reactor. Determined sensitivities for boron varied from 6.2·10–8 to 1.73·10–6 cpm·ng–1 (n·cm–2J·s–1)–1 depending on the physical characteristics of the samples. For a nominal counting time of ten minutes the lower limit of mass detection of natural boron was determined to be 12.1 nanograms. The analytical method was applied to the estimation of boron in fourteen samples of natural aerosols collected on membrane filters. Analysis of prepared samples and natural aerosol samples by ICP emission showed good agreement with analysis via the (n,) reaction. Application of the method to other sample types was demonstrated by the determination of boron in samples of borosilicate glass and borated polyethylene.  相似文献   

15.
An epithermal energy neutron irradiation facility has been used to perform instrumental activation analysis for iodine, silicon, nickel, zirconium, uranium and thorium. The facility, which is adjacent to the fuel of the University of Virginia 2.0 MW pool reactor, consists of a dry sample region surrounded by a fixed cadmium shield. A boron nitride capsule can be used to hold the sample in the cadmium facility to further enhance the reduction of thermal neutron activation. The neutron fluence rate is 2.2×1016 n·m–2·s–1 for fission spectrum energy neutrons (measured with Ni(n,p)Co) and 8.2·1015 n·m–2·s–1 for resonance energy neutrons (measured with gold).Iodine has been measured at concentrations as low as 0.1 mg/kg with 3% counting statistics in powdered infant formula and 0.15 mg/kg with 5% statistics in liquid infant formula. Silicon has been measured at concentrations of 0.2% in biological samples with counting statistics between 5 and 10% and in coal and soil at concentrations greater than 4% with better than 1% statistics. Nickel has been measured in coal and soil at the 20 mg/kg level and higher with 6% statistics. Zirconium has been determined at 600 mg/kg and greater in ceramics with counting errors less than 3%. Uranium and thorium have been measured at the 10 mg/kg level with 3% counting statistics.  相似文献   

16.
As a contribution to nondestructive neutron assay of reactor grade aluminium, a number of elements have been investigated qualitatively and quantiatively using a vertical channel in the IRT-5000 reactor with a thermal neutron flux of 7.6·1012n·cm–2·s–1. The -ray spectra of irradiated samples were analysed with a 30 cm3 Ge(Li) detector connected to an HP-computer and a 4096 channel analyser. The following impurities have been determined: Sc, Ca, Cr, Fe, Ni, Co, Zn, As, Sb, W, Au, Th and U, while Lu and Hf have been determined qualitatively only.  相似文献   

17.
Instrumental neutron activation analysis (INAA) technique has been applied to a water sample to determine the elemental concentrations. The sample was irradiated at a neutron flux of 1.2·1012 n·cm–2·s–1 for two different periods followed by counting at three different decay times, using two coaxial type high-resolution Ge(Li) detectors. The dominant elements detected in the water sample are Ca, Cl, Na, Mg, and K present in levels while Co, I, Mn, Sm, and Sb are present in smaller amounts approximately on the average 0.01 ppm. Only traces of other elements such as rare-earth elements, Ag, As, Ba, Cu, Cd, Fe, Sr, W, Zn, seem to be present in the water samples.  相似文献   

18.
The application of stable isotope analysis using neutron-induced prompt -ray analysis (PGA) with cold/thermal neutron beams for the tracer study of geological materials are discussed. Silicon has three natural isotopes differing in abundance:28Si (92.23%),29Si (4.67%) and30Si (3.10%). For the purpose of the assessment of Si migration in engineered barrier material, enriched30Si can be used as a tracer due to its nuclear and chemical properties. Isotope analysis of30Si was performed by PGA during the tracer study. Neutron intensity at the sample position was 1.4·108 n¢cm–2·s–1, 2.4·107 n·cm–2·s–1 for cold and themal neutron guided beams of JRR-3M, respectively. Calibration curves and analytical sensitivity of30Si were determined based on measurement of standard samples. BG and detection limits for30Si analysis were also measured in Japanese bentonite (Kunigel V1 and Kunipia F) and their pore water. Fiffteen elements were determined simultaneously using PGA.  相似文献   

19.
An instrument for neutron capture prompt gamma-ray activation analysis (PGAA) has been constructed as part of the Cold Neutron Research Facility at the 20 MW National Institute of Standards and Technology Research Reactor. The neutron fluence rate (thermal equivalent) is 1.5·108 n ·cm–2·s–1, with negligible fast neutrons and gamma-rays. With compact geometry and hydrogen-free construction, the sensitivity is sevenfold better than an existing thermal instrument. Hydrogen background is thirtyfold lower.  相似文献   

20.
A method is described to separate trace amounts of selenium in organic samples without using a carrier, based on the adsorption on active carbon filters of the complex formed with APDC at pH 1.5. The separation is made prior to the neutron irradiation and the correction for selenium in the reagents performed by the irradiation of a blank. The method has been successfully used in fodder samples as well as some other organic reference materials, using a fast pneumatic transfersystem, which takes the samples from the irradiation position to the counting position in 3s, with the only limitation of the thermal neutron flux available, 4.7·1011 cm–2·s–1. Detection limits of 0.1 g are obtained under these experimental conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号