1.
This paper describes the automated in situ trace element analysis of solid materials by laser ablation (LA) inductively coupled plasma mass spectrometry (ICP-MS). A compact computer-controlled solid state Nd:YAG Merchantek EO UV laser ablation (LA) system has been coupled with the high sensitivity VG PQII S ICP-MS. A two-directional communication was interfaced in-house between the ICP-MS and the LA via serial RS-232 port. Each LA-ICP-MS analysis at a defined point includes a 60 s pre-ablation delay, a 60 s ablation, and a 90 s flush delay. The execution of each defined time setting by LA was corresponding to the ICP-MS data acquisition allowing samples to be run in automated cycle sequences like solution auto-sampler ICP-MS analysis. Each analytical cycle consists of four standards, one control reference material, and 15 samples, and requires about 70 min. Data produced by Time Resolved Analysis (TRA) from ICP-MS were later reduced off-line by in-house written software. Twenty-two trace elements from four reference materials (NIST SRM 613, and fused glass chips of BCR-2, SY-4, and G-2) were determined by the automated LA-ICP-MS method. NIST SRM 610 or NIST SRM 613 was used as an external calibration standard, and Ca as an internal standard to correct for drift, differences in transport efficiency and sampling yield. Except for Zr and Hf in G-2, relative standard deviations for all other elements are less than 10%. Results compare well with the data reported from literature with average limits of detection from 1 ng x g(-1) to 455 ng x g(-1) and less than 100 ng x g(-1) for most trace elements.  相似文献   

2.
Simultaneous ion sampling and sequential detection offered by inductively coupled plasma 'time of flight' mass spectrometry (ICP-TOFMS) provides advantages for the analysis of short transient concentration-variable signals as produced in laser ablation. In order to investigate the capabilities of ICP-TOFMS in combination with an excimer laser ablation system, ablation studies on reference materials and geological samples were carried out. Various ICP-TOFMS parameters were optimized for laser-induced aerosols. Transverse rejection ion pulse was used to extend the dynamic range in concentration. A reduced volume ablation cell was designed and used in order to increase the sample density in the ICP. Results for 63 simultaneously measured isotopes (SRM 610 from NIST) lead to limits of detection in the 1-100 microg/g range for a 80 microm crater diameter (10 Hz, 1.2 mJ pulse energy). The reproducibility of signal ratios was determined to be better than 2% RSD for transient signals using 102 ms integration time. These optimized parameters were then used for the analysis of tin-rich fluid inclusions. Preliminary results of multielement analysis and isotopic ratio determinations on individual fluid inclusions (63 isotopes, 102 ms integration time) demonstrate the capabilities of ICP-TOFMS in combination with laser ablation.  相似文献   

3.
Ongoing discussions about the origin of elemental fractionation occurring during LA-ICP-MS analysis show that this problem is still far from being well understood. It is becoming accepted that all three possible sources (ablation, transport, excitation) contribute to elemental fractionation. However, experimental data about the vaporisation size limit of different particles in the ICP, as produced in laser ablation, have not been available until now. This information should allow one to determine the signal contributing mass within the ICP and would further clarify demands on suitable laser ablation systems and gas atmospheres in terms of their particle size distribution.The results presented here show a vaporisation size limit of laser induced particles, which was found at particle sizes between 90 nm and 150 nm using an Elan 6000 ICP-MS. Due to the fact that the ICP-MS response was used as evaluation parameter, vaporisation and ionisation limits are not distinguishable.The upper limit was determined by successively removing the larger particles from the aerosol, which was created by ablation of a NIST 610 glass standard at a wavelength of 266 nm, using a recently developed particle separation device. Various particle fractions were separated from the aerosol entering the ICP. The decrease in signal intensity is not proportional to the decrease in volume, indicating that particles above 150 nm in diameter are not completely ionised in the ICP. Due to the limited removal range of the particle separation device, which cannot remove particles smaller than 150 nm, single hole ablations were used to determine the lower vaporisation limit. This is based on measurements showing that larger particles occur dominantly during the first 100 laser pulses only. After this period, the ratio of ICP-MS counts and total particle volume was found to be constant while most of the particles are smaller than 90 nm, indicating complete vaporisation and ionisation of these particles.To describe the influence of different plasma forward powers on the vaporisation limit, the range 1000–1600 W was studied. Results indicate that optimum vaporisation and ionisation occurs at 1300 W. However, an increase of the particle ionisation limit towards larger particles was not observed within the accuracy of this study using the full range of parameters available for optimisation on commonly used ICP-MS instruments.  相似文献   

4.
A study of LA-ICP-MS analysis of pressed powdered tungsten carbide precursors was performed to show the advantages and problems of nanosecond laser ablation of matrix-unified samples. Five samples with different compositions were pressed into pellets both with silver powder as a binder serving to keep the matrix unified, and without any binder. The laser ablation was performed by nanosecond Nd:YAG laser working at 213 nm.The particle formation during ablation of both sets of pellets was studied using an optical aerosol spectrometer allowing the measurement of particle concentration in two size ranges (10-250 nm and 0.25-17 μm) and particle size distribution in the range of 0.25-17 μm. Additionally, the structure of the laser-generated particles was studied after their collection on a filter using a scanning electron microscope (SEM) and the particle chemical composition was determined by an energy dispersive X-ray spectroscope (EDS).The matrix effect was proved to be reduced using the same silver powdered binder for pellet preparation in the case of the laser ablation of powdered materials.The LA-ICP-MS signal dependence on the element content present in the material showed an improved correlation for Co, Ti, Ta and Nb of the matrix-unified samples compared to the non-matrix-unified pellets. In the case of W, the ICP-MS signal of matrix-unified pellets was influenced by the changes in the particle formation.  相似文献   

5.
Fliegel D  Frei C  Fontaine G  Hu Z  Gao S  Günther D 《The Analyst》2011,136(23):4925-4934
The influence of the addition of carbon using methane or methanol/water to an inductively coupled plasma (ICP) via the carrier gas flow on the sensitivity in laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was studied. During the ablation of SRM NIST 610 with simultaneous addition of CH(4) (0.6-1.4 ml min(-1)), a sensitivity enhancement of more than one order of magnitude for selected analytes (e.g. (75)As(+)) was observed. In addition to the sensitivity enhancement for As, Te, I and Se, also all other measured elements showed a significantly enhanced sensitivity (minimum by a factor of 2). Potential mechanisms for the observed intensity enhancement include charge transfer reactions, a change in the ICP shape and a temperature increase in the plasma. Furthermore, the aspiration of a methanol-water mixture into a cooled spray chamber and the simultaneous addition to the laser ablated aerosol was investigated. This type of mixing leads to a sensitivity enhancement up to a factor of 20. To prevent clogging of the sampler cone and skimmer cone by carbon deposition, a fast cleaning procedure for the interface is tested during running ICP, which allows the application of such a set-up for specific applications.  相似文献   

6.
An on-line low gas pressure cell device has been developed for elemental analysis using laser ablation-ICP-mass spectrometry (LA-ICPMS). Ambient gas in the sample cell was evacuated by a constant-flow diaphragm pump, and the pressure of the sample cell was controlled by changing the flow rate of He-inlet gas. The degree of sample re-deposition around the ablation pit could be reduced when the pressure of the ambient gas was lower than 50 kPa. Produced sample aerosol was drawn and taken from the outlet of the diaphragm pump, and directly introduced into the ICP ion source. The flow rate of He gas controls not only the gas pressure in the sample cell, but also the transport efficiency of the sample particles from the cell to the ICP, and the gas flow rate must be optimized to maximize the signal intensity of the analytes. The flow rates of the He carrier and Ar makeup gas were tuned to maximize the signal intensity of the analytes, and in the case of (238)U from the NIST SRM610 glass material, the signal intensity could be maximized with gas flow rates of 0.4 L/min for He and 1.2 L/min for Ar. The resulting gas pressure in the cell was 30 - 35 kPa. Using the low gas pressure cell device, the stability in the signal intensities and the resulting precision in isotopic ratio measurements were evaluated. The signal intensity profile of (63)Cu obtained by laser ablation from a metallic sample (NIST SRM976) demonstrated that typical spikes in the transient signal, which can become a large source of analytical error, were no longer found. The resulting precision in the (65)Cu/(63)Cu ratio measurements was 2 - 3% (n = 10, 2SD), which was half of the level obtained by laser ablation under atmospheric pressure (6 - 10%). The newly developed low-pressure cell device provides easier optimization of the operational conditions, together with smaller degrees of sample re-deposition and better stability in the signal intensity, even from a metallic sample.  相似文献   

7.
Fundamental understanding of aerosol formation and particle transport are important aspects of understanding and improving laser-ablation ICP–MS. To obtain more information about particles entering the ICP, laser aerosols generated under different ablation conditions were collected on membrane filters. The particles and agglomerates were then visualised using scanning electron microscope (SEM) imaging. To determine variations between different sample matrices, opaque (USGS BCR-2G) and transparent (NIST SRM 610) glass, CaF2, and brass (MBH B26) samples were ablated using two different laser wavelengths, 193 and 266 nm. This study showed that the condensed nano-particles (∼10 nm in diameter) formed by laser ablation reach the ICP as micron-sized agglomerates; this is apparent from filters which contain only a few well-separated particles and particle agglomerates. Ablation experiments on different metals and non-metals show that the structure of the agglomerates is matrix-dependent. Laser aerosols generated from silicates and metals form linear agglomerates whereas particle-agglomerates of ablated CaF2 have cotton-like structures. Amongst other conditions, this study shows that the absorption characteristics of the sample and the laser wavelength determine the production of micron-sized spherical particles formed by liquid droplet ejection.  相似文献   

8.
采用213 nm-纳秒激光剥蚀系统对生物基体样品的剥蚀颗粒进行研究,优化了激光剥蚀条件.在剥蚀能量为25%,束斑直径为200 μm,剥蚀速率为20 μm/s,频率为20 Hz,载气为700 mL He + 700 mL Ar时,信号强度及稳定性最佳.以31P为内标元素,最佳剥蚀条件下,考察了56个元素的相对分馏因子.结果表明,生物基体的剥蚀颗粒相较于NIST 610 玻璃标样更大,达到3 μm;生物基体中元素分馏效应相较于玻璃基体小,大多数元素的相对分馏因子达到1.0 ±0.1.探讨了生物基体中元素分馏机理,分析了生物基体相较于玻璃基体剥蚀颗粒大,而相对分馏因子未明显增大的原因.一方面可能是粒径3 μm的颗粒进入电感耦合等离子体后能原子化;另一方面,大的剥蚀颗粒的富集效应相对较小.进一步对分馏效应的影响因素进行研究,发现分馏效应与激光剥蚀能量、激光频率和扫描速率相关,并且与元素的氧化物沸点负相关,与氧化物键能和电离能正相关.  相似文献   

9.
The influence of sample matrix composition, absorption behavior and laser aerosol particle size distribution on elemental fractionation in laser ablation inductively coupled plasma mass spectrometry was studied for nanosecond laser ablation at a wavelength of 266 nm. To this end, lithium tetraborate glass samples with different iron oxide contents and trace amounts of a group of 11 elements were prepared synthetically. The samples were characterized in terms of optical absorbance, melting points, trace element concentrations and homogeneity. UV/VIS spectra showed that sample absorption rises with increasing Fe2O3 content. Crater depths and time-dependent particle size distributions were measured, and ablated and transported sample volumes were estimated. Furthermore, the laser aerosol was filtered using a particle separation device and transient ICP-MS signals were acquired with and without filtering the aerosol. The results demonstrate that the amount of ablated sample is related to the absorption coefficient of the sample and therefore to the optical penetration depth of the laser beam into the sample. The higher energy densities resulting from the shorter penetration depths result in smaller average particle sizes for highly absorbing samples, which allows more efficient transport to and atomization and excitation of the ablated material within the ICP. The particle size distribution changes continuously with ablation time, and larger particle fractions occur mainly at the beginning of the ablation, which leads to particle-related fractionation processes at the beginning of the transient signal. Exceeding a critical depth to diameter ratio, laser-related elemental fractionation processes occur. Changes in the volatile to non-volatile element intensity ratio after the aerosol is filtered indicate that particle size-related enrichment processes contribute to elemental fractionation.  相似文献   

10.
Four different artificial aerosol particles as well as one standard environmental aerosol particle (NIST SRM 1649a) were investigated. While the mass loss of the aerosol particles varies from 1.5 to 32% of the entire mass, only a small part of each volatile fraction consists of organic compounds. Due to the construction of the combined thermoanalytical system, only a small part of the evolved gases is used for the mass spectrometric investigation. This results in a restricted sensitivity which does not allow an identification of individual organic components. Additional investigations like thermal desorption GC-MS reveal up to 1600 individual components (SRM 1649a). This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

11.
Sampling behavior of multielements for NIST SRM 2703, a marine sediment, was studied with sample sizes from 1 mg down to ng level by a combination of INAA, PIXE and SRXRF. On 1 mg sample size level, sampling behavior for multielements in NIST SRM 2703 and its parent SRM 2702 were comparatively characterized by using INAA combining with Ingamells model. Results showed that sampling uncertainties for 12 elements of both materials were found to be better than 1%, and those of four other elements in SRM 2703 better than in SRM 2702. At sample sizes not able to be accurately weighed (<1 mg), PIXE and SRXRF were used and the effective sample sizes estimated. Sampling uncertainties for nine elements were found to be better than 1% at sample sizes of tenth mg level, and those for six elements better than 10% on ng levels.  相似文献   

12.
The particle size distribution in laser ablation inductively coupled plasma mass spectrometry is known to be a critical parameter for complete vaporization of particles. Any strategy to reduce the particle size distribution of laser generated aerosols has the potential to increase the ion signal intensity and to reduce fractionation effects. Due to the fact that vapor generation, nucleation, condensation, and agglomeration take place within an extremely short period of time, ablation under atmospheric pressure might not allow influencing these processes while under reduced pressure condition the cooling of the aerosol and therefore the condensation is expected to be slower. In this study, a low pressure laser ablation cell for the generation of laser aerosols was coupled to an ICP-MS. In contrast to the previously developed trapped ablation mode, the newly designed cell allows the adjustment of the pressure in the ablation cell between 20 and 1400 mbar prior to the ablation.Ablation experiments carried out using this configuration showed a dependence of the aerosol properties (size distribution and particle structure) on the ablation cell pressure. The intensity ratio U/Th measured as a figure of merit for complete vaporization within the ICP indicated a change in the aerosol structure at approximately 500 mbar toward smaller particle size. A significant difference between low pressure and at ambient pressure ablated aerosol was observed. The intensity ratios (U/Th) of the ablated sample moves closer to the bulk composition at lower pressures at the expense of sensitivity. Therefore the decrease in the ICP-MS signal intensity in the low pressure cell can be attributed to vapor deposition within the ablation cell walls.Moreover, scanning electron microscope images of aerosols collected on filters after the low pressure ablation cell suggest the possibility of a slower cooling velocity of the aerosol, which was observed in the condensed material on the surface of ejected spherical particles. The expansion of the laser aerosol was also investigated using polished brass substrates in the expansion path-way for particle collection.  相似文献   

13.
The platinum group elements (PGEs), particularly platinum, palladium and rhodium, are nowadays increasingly emitted into the environment from automotive catalytic converters. Thus, a method for the determination of PGEs (especially platinum and rhodium) in dust and plant samples was developed. The developed method was based on microwave-assisted sample digestion and inductively coupled plasma mass spectrometric (ICP-MS) determination. Spectral interferences in ICP-MS determination were corrected using mathematical correction equations based on signal ratio measurement. In addition, platinum and rhodium concentrations in the digested dust samples were also determined after Te coprecipitation without correction of the interferences. The results for platinum and rhodium in reference materials (NIST SRM 2557, recycled monolith autocatalyst and BCR-723, road dust) were in good agreement with the certified values. Preliminary results for the anthropogenic platinum and rhodium emissions in Oulu, northern Finland, based on dust and plant samples, indicated a common traffic-related source of these metals.  相似文献   

14.
A microwave digestion method in a closed vessel was developed for the determination of trace metals in atmospheric aerosols using inductively coupled plasma mass spectrometry (ICP-MS). A recovery study for the elements V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Cd, Sb, and Pb was conducted using multi-elemental standard solutions, NIST 1633b Trace Elements in Coal Fly Ash, and NIST 1648 Urban Particulate Matter. A simple digestion method using only HNO3/H2O2 gave good recoveries (90%-108%) for all elements except Cr in SRM 1648, but yielded low recoveries for SRM 1633b. A more robust method using HNO3/H2O2/HF/H3BO3 yielded higher recoveries (82%-103%) for the lighter elements (V-Zn) in SRM 1633b, and improved the Cr recovery in SRM 1648, but decreased the Se recovery in both SRMs. A comparative analysis of aerosol samples obtained at a remote mountain location Nathiagali, Pakistan (2.5 km above mean sea level), and Mayville, New York, downwind from the highly industrialized Midwestern United States, was carried out using Instrumental Neutron Activation Analysis (INAA) for the elements Cr, Mn, Fe, Co, Zn, As, Se, and Sb. The simple digestion method yielded excellent agreement for Cr, Fe, Zn, As, Se, and Sb, with slopes of the ICP-MS vs. INAA regressions of 0.90-1.00 and R2 values of 0.96-1.00. The regressions for Mn and Co had slopes of 0.82 and 0.84 with R2 values of 0.83 and 0.82, respectively. Addition of HF/H3BO3 did not improve the correlation for any of the elements and degraded the precision somewhat. The technique provides sensitivity and accuracy for trace elements in relatively small aerosol samples used in atmospheric chemistry studies related to SO2 oxidation in cloud droplets. The ability to determine concentrations of a very large number of elements from a single analysis will permit source apportionment of various trace pollutants and hence strategies to control the sources of air pollution. This is particularly important as the health effects of particulate matter are increasingly recognized.  相似文献   

15.
In this study, we examined the influence of the matrix on rare earth element (REE) analyses of carbonate with laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS) using carbonate and NIST glass standards. A UV 213 nm Nd:YAG laser system was coupled to an ICP-MS. Laser-ablation was carried out in both He and Ar atmospheres to investigate the influence of ablation gas on the analytical results. A small amount of N2 gas was added to the carrier gas to enhance the signal intensities. Synthetic CaCO3 standards, doped with REEs, as well as NIST glasses (NIST SRM 610 and 612) were used as calibration standards. Carbonatite, which is composed of pure calcite, was analyzed as carbonate samples. The degree of the influence of the matrix on the results was evaluated by comparing the results, which were calibrated by the synthetic CaCO3 and NIST glass standards. With laser-ablation in a He atmosphere, the differences between the results calibrated by the synthetic CaCO3 and NIST glass standards were less than 10% across the REE series, except for those of La which were 25%. In contrast, for the measurements made in an Ar atmosphere, the results calibrated by the synthetic CaCO3 and NIST glass standards differed by 25-40%. It was demonstrated that the LA-ICP-MS system can provide quantitative analysis of REE concentrations in carbonate samples using non matrix-matched standards of NIST glasses.  相似文献   

16.
Simultaneous and multi-elemental method was optimized to determine 35 elements in 274 coarse and fine aerosol samples by using HR-ICP-MS. The procedures were validated. Measurement uncertainties of all elements including sampling uncertainties were calculated by applying bottom-up approach. The average recoveries obtained for each element ranged between 79% and 129% using NIST SRM 1648, urban dust. The calculated uncertainties of the analytical methods were between 2.9% and 18% for both sample types. The major contributions to the uncertainty budget come from the calibration curves, repeatability and volume of air.  相似文献   

17.
The capability of a second-generation Nu Instruments multiple collector inductively coupled plasma mass spectrometer (MC-ICP-MS) has been evaluated for precise and accurate isotope-ratio determinations of lead. Essentially the mass spectrometer is a double-focusing instrument of Nier-Johnson analyzer geometry equipped with a newly designed variable-dispersion ion optical device, enabling the measured ion beams to be focused into a fixed array of Faraday collectors and an ion-counting assembly. NIST SRM Pb 981, 982, and 983 isotopic standards were used. Addition of thallium to the lead standards and subsequent simultaneous measurement of the thallium and lead isotopes enabled correction for mass discrimination, by use of the exponential correction law and 205Tl/203Tl = 2.3875. Six measurements of SRM Pb-982 furnished the results 206Pb/204Pb = 36.7326(68), 207Pb/204Pb = 17.1543(30), 208Pb/204Pb = 36.7249(69), 207Pb/206Pb = 0.46700(1), and 208Pb/206Pb = 0.99979(2); the NIST-certified values were 36.738(37), 17.159(25), 36.744(50), 0.46707(20), and 1.00016(36), respectively. Direct isotope lead analysis in silicates can be performed without any chemical separation. NIST SRM 610 glass was dissolved and introduced into the MC-ICP-MS by means of a micro concentric nebulizer. The ratios observed were in excellent agreement with previously reported data obtained by TIMS and laser ablation MC-ICP-MS, despite the high Ca/Pb concentration ratio (200/1) and the presence of many other elements at levels comparable with that of lead. Approximately 0.2 microg lead are sufficient for isotope analysis with ratio uncertainties between 240 and 530 ppm.  相似文献   

18.
Simultaneous ion sampling and sequential detection offered by inductively coupled plasma ‘time of flight’ mass spectrometry (ICP-TOFMS) provides advantages for the analysis of short transient concentration-variable signals as produced in laser ablation. In order to investigate the capabilities of ICP-TOFMS in combination with an excimer laser ablation system, ablation studies on reference materials and geological samples were carried out. Various ICP-TOFMS parameters were optimized for laser-induced aerosols. Transverse rejection ion pulse was used to extend the dynamic range in concentration. A reduced volume ablation cell was designed and used in order to increase the sample density in the ICP. Results for 63 simultaneously measured isotopes (SRM 610 from NIST) lead to limits of detection in the 1–100 μg/g range for a 80 μm crater diameter (10 Hz, 1.2 mJ pulse energy). The reproducibility of signal ratios was determined to be better than 2% RSD for transient signals using 102 ms integration time. These optimized parameters were then used for the analysis of tin-rich fluid inclusions. Preliminary results of multielement analysis and isotopic ratio determinations on individual fluid inclusions (63 isotopes, 102 ms integration time) demonstrate the capabilities of ICP-TOFMS in combination with laser ablation. Received: 6 March 2000 / Revised: 11 May 2000 / Accepted: 14 May 2000  相似文献   

19.
The influence of sample properties and composition on the size and concentration of aerosol particles generated by nanosecond Nd:YAG laser ablation at 213 nm was investigated for three sets of different materials, each containing five specimens with a similar matrix (Co-cemented carbides with a variable content of W and Co, steel samples with minor differences in elemental content and silica glasses with various colors). The concentration of ablated particles (particle number concentration, PNC) was measured in two size ranges (10–250 nm and 0.25–17 µm) using an optical aerosol spectrometer. The shapes and volumes of the ablation craters were obtained by Scanning Electron Microscopy (SEM) and by an optical profilometer, respectively. Additionally, the structure of the laser-generated particles was studied after their collection on a filter using SEM.  相似文献   

20.
《Analytical letters》2012,45(8):1533-1542
Abstract

A method was developed for the analysis of borosilicate catalysts. Samples were prepared by fusion technique with potassium hydroxide and analyzed by inductively coupled plasma atomic emission spectroscopy (ICP-AES). The method was applied to a borosilicate NIST SRM 93 which was analyzed for major and minor elements (aluminum, sodium, silicon and boron). Despite the presence of relatively high concentration of the potassium, no matrix interferences were observed. This method provides precision and accuracy better than ±4% and ±6%, respectively.  相似文献   