首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Concentrations of Al, As, Ba, Be, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Se, Sn, V and Zn in road dust particles at seven sites in the Delta region have been investigated using atomic absorption spectroscopy (AAS). Results showed that samples were highly contaminated with Cd, Pb, Sn and Zn and moderately contaminated with As, Se, Ba and Cu when compared to the average crustal background concentrations of metals. The output of the principle component analysis revealed that Al, Fe, Be and Mn were predominantly driven from natural sources and that all the other metals were anthropogenically driven from industrial activities (As, Ba, Cd, Cr, Cu, Se, and Sn) and traffic emissions (Pb, Ni and V). Results of the applied risk assessment indicated that the higher risk of occurrence of adverse non-carcinogenic health effects is associated with the exposure of children to Al, Fe, As, Cr, Pb and Zn via the ingestion pathway and that carcinogenic health effects are not expected to occur from the exposure to metals in the road dust of the Delta region. However, given the large uncertainties associated with the estimates of toxicity values and exposure factors, and the absence of site-specific biometric factors, these results should be regarded as a screening data. Further research should be undertaken before any definite conclusions regarding potential health effects are drawn.  相似文献   

2.
A method for simultaneously determining the trace elements in particulate matter (PM) (PM2.5) by inductively coupled plasma mass spectrometry was established. The PM2.5-loaded filter samples were digested under the optimised conditions including a mixture of HNO3–HCl–HF with ultrasonication proceeding at 70°C for 2 h. Recoveries of 90.83–103.33% were achieved for 20 elements (Co, Sr, Ag, Cd, Sb, La, Ce, Sm, W etc.) in NIST standard reference material 1648a (urban PM). PM2.5 samples were collected at urban site in Hangzhou from August 2015 to November 2015. PM2.5 concentrations of 15% sampling days exceeded the daily limitation and the mean concentrations of PM2.5 from August to November reached the 66.4% of the limitation. PM2.5 concentrations in summer were higher than that in autumn. The concentration of Zn was highest, following with Al, Pb, Mn, Cu and As. Significant enrichment was observed in Mn, Zn, Pb, Ag, V, Ni, Cu, As, Se, Hg, Co, Cd and W, which was probably induced by vehicular exhaust, oil and residual fuel combustion and industrial emissions. The daily mass concentrations of PM2.5 and elements fluctuated significantly. Rainfall could significantly reduce the concentration of Ti, Mn, Cu, Zn, As, Se, Hg, Sr, Ag, Cd, Sb, La, Ce, Sm and Pb, and the risk levels of carcinogenic elements and non-carcinogenic elements in rain day were significantly lower (43.7–81.4%) than those in non-rain day. The risk levels of Co, Cd and As could lead to adverse health outcomes through the respiratory system, which should deserve more attention, while the risk levels of Ni and non-carcinogenic elements (Hg, Mn, Cu, Zn, Pb, V) were under average risk acceptance.  相似文献   

3.
The aim of this study was the evaluation of the trace element contamination level in sediments of the most important rivers in Serbia and their tributaries. The determination of the aqua regia soluble contents of 12 micro- and macro-elements (Ca, Cd, Co, Cr, Cu, Fe, Mn, Pb, Ni, Zn, Be and V) in sediments was developed by the microwave digestion technique combined with inductively coupled plasma atomic emission spectrometry. Correlation analysis and principal component analysis distinguishes factors of lithogenic and anthropogenic origins. The Fe, Mn, Be and V contents are controlled by a regional lithogenic high background factor, while Cd, Cr, Pb, Ni, Zn and Cu are recognized as tracer of pollution. For Co, mixed sources from both lithogenic and anthropogenic inputs were evidenced.The investigated sediment of the major rivers and their tributaries in Serbia showed high concentrations of metals, especially of Cd, Pb, Cu and Zn, which may cause serious environmental impacts. Rivers which flow into the Danube from its entrance into Serbia significantly influence the chemical load of the water and sediments.The experimental study was conducted using two BCR standard reference materials. The calculated accuracy and precision confirmed the good performance of the adopted procedures.  相似文献   

4.
Road dust samples were collected in different locations of heavy traffic, medium traffic, express way and industrial areas of Mumbai. The concentrations of various elements (Mg, Al, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn and Pb) in road dust samples were analyzed using EDXRF. The average elemental profile of road dust in Mumbai was comparable with studies carried out in other countries with slight variations. The estimated geo accumulation indices and enrichment factors indicated moderate elemental contamination and enrichment of anthropogenic elements in road dust samples. Factor analysis of elemental data resolved four sources namely crustal, tyre wear, vehicular/industrial emissions and break wear.  相似文献   

5.
《Microchemical Journal》2010,94(2):147-152
This study reports the spatial distribution pattern and degree of heavy metal pollution (Cd, Cr, Cu, Ni, Pb, Mn, Be, Co, Zn and U) in 169 urban road dust samples from urban area of Urumqi city. The spatial distribution pattern shows that Cu, Pb, Cr and Zn have similar patterns of spatial distribution. Their hot-spot areas were mainly associated with main roads where high traffic density was identified. Ni and Mn show similar spatial distributions coinciding with the industrial areas, while the spatial distribution patterns of Co and U show hot-spot areas were mainly located in the sides of the urban area where the road dust was significantly influenced by natural soils. The spatial distributions of Be and Cd were very different from other metals. The geo-accumulation index suggests that road dust in Urumqi city was uncontaminated to moderately contaminated with Cd, Cu, Ni, Pb, Mn, Be, Zn and U. The integrated pollution index shows IPIs of all road dust samples were higher than 1, suggesting that the road dust quality of Urumqi city has clearly been polluted by anthropogenic emission of heavy metals. Moreover, the spatial distribution pattern of IPIs also shows several distribution trends in the studied region.  相似文献   

6.
This study reports the spatial distribution pattern and degree of heavy metal pollution (Cd, Cr, Cu, Ni, Pb, Mn, Be, Co, Zn and U) in 169 urban road dust samples from urban area of Urumqi city. The spatial distribution pattern shows that Cu, Pb, Cr and Zn have similar patterns of spatial distribution. Their hot-spot areas were mainly associated with main roads where high traffic density was identified. Ni and Mn show similar spatial distributions coinciding with the industrial areas, while the spatial distribution patterns of Co and U show hot-spot areas were mainly located in the sides of the urban area where the road dust was significantly influenced by natural soils. The spatial distributions of Be and Cd were very different from other metals. The geo-accumulation index suggests that road dust in Urumqi city was uncontaminated to moderately contaminated with Cd, Cu, Ni, Pb, Mn, Be, Zn and U. The integrated pollution index shows IPIs of all road dust samples were higher than 1, suggesting that the road dust quality of Urumqi city has clearly been polluted by anthropogenic emission of heavy metals. Moreover, the spatial distribution pattern of IPIs also shows several distribution trends in the studied region.  相似文献   

7.
Rain water samples collected at three different locations in Italy during 1999 were analysed for heavy metals determination. Results for V, Cr, Mn, Co, Cu, Cd, Sb, Pb, Al and Ni are reported in this paper. For most of the elements higher concentration values have been measured in the samples from Alpe Gera (rural site): only for Cd and V were the concentrations higher at Pisa. The total annual deposition (microg m(-2) y(-1)) shows a similar behaviour, with Alpe Gera being the location with highest total annual input for Cr, Mn, Co, and in particular for Cu, Sb, Pb and Al. The reason of the higher deposition at a rural site in comparison to a urban one (Milan) is not known: further experimental work and investigations are needed. Generally, no evident seasonal trends have been observed for the measured concentrations, while few correlations have been found among elements within the same station. Crustal contribution to total concentration varies from about 20% for V to less than 1% for Cu, Cd, Sb, Pb and Ni.  相似文献   

8.
The following paper shows results of PM10 level and Cd, Cr, Cu, Fe, Mn, Ni, Pb, V and Zn concentrations present in this fraction for filters collected in the urban area of Campi Salentina (Apulia, Southern Italy) in 2004 in order to inquire into air quality. PM10 and lead concentrations did not exceed the standard values sanctioned by Italian Legislature with average values equal to 36.54 +/- 14.57 microg x m(-3) and 9.19 +/- 5.24 ng x m(-3) respectively. Significant correlations have been found between the pairs Fe-Mn, Ni-V, Cr-Ni and Cd-Cr. This suggests that these metals have a similar pollution source probably due to metallurgical activity. Multivariate statistical analysis showed that it is possible to distinguish the PM10 samples collected in sampling periods with different meteorological conditions. Indeed, metals concentration increases for samples characterized by scarce rains or by winds prevailing from North or North-West and is reduced due to different meteorological conditions, although there are some exceptions.  相似文献   

9.
Neutron activation analysis methods for the determination of impurities in zirconium cladding material and uranium oxide are described. Detection limits for the elements Al, Cd, Cr, Co, Cu, Hf, Fe, Mn, Ni, W and U in zirconium are below that required by the ASTM B 352-79 standard. The method has been tested on the NIST SRM 360a Zircaloy-2 from which the elements Na, Mg, Al, Ca, V, Cr, Fe, Co, Ni, Cu, Eu and U have been detected. The values for Cr, Fe, Ni and Cu are compared with the certified values. A method for the pre-irradiation separation of the elements Mg, Na, Al, K, Sc, Ca, V, Mn, Cr, Fe, Co, Cu, Zn, Rb, Zr, Cd, Cs, REE and Hf from uranium has been developed. A neutron activation analysis method for the determination of those elements in uranium is described. The method is tested by the analysis of the IAEA reference sample SR-54/64. The elements Al, Mn, V, Cu, Cr, Co, Ni and Fe have been detected and the results compared with the certified values.  相似文献   

10.
In this work, SPLITT Fractionation (split flow thin cell) is used to sort hydrodynamically sedimented particles coming from the Sacca di Goro, a lagoon-like system close to the Po River delta (Italy). First the possibility of performing quantitative mass separations with a SPLITT cell apparatus was checked on a standard silica sample of known particle size distribution (PSD). Environmental sediment samples and relative SPLITT sub-fractions were subject to Inductive Coupled Plasma--Atomic Emission Spectroscopy (ICP-AES) characterization for the following elements: Al, Fe, Cd, Cr, Cu, Ni, Mn, Pb and Zn. The distribution of these metals by particle size fractions has been investigated. The accuracy of the entire separation procedure has been also evaluated.  相似文献   

11.
Summary The cation-exchange behaviour of Mn(II), Cd(II), Co(II), Ni(II), Zn(II), Cu(II), Fe(III), Sc(III), Y(III), Eu(III), Dy(III), Ho(III), Yb(III), Ti(IV) and Nb(V) in malate media at various concentrations and pH, was studied with Dowex 50 WX8 resin (200–400 mesh) in the ammonium form. Separation of Fe(III)/Cu(II), Fe(III)/Cu(II)/Zn(II), Fe(III)/Co(II)/Mn(II), Cu(II)/Ni(II)/Mn(II), Fe(III)/Cu(II)/Co(II)/Mn(II), Fe(III)/Cu(II)/Ni(II)/Cd(II), Yb(III)/Eu(III), Sc(III)/Y(III),Sc(III)/Yb(III)/Dy(III) and Nb(V)/Yb(III)/Ho(III) has been achieved, among others.This work was supported by C.N.R. of Italy.  相似文献   

12.
Summary The analytical performance of an on-line oxine-cellulose microcolumn preconcentration system coupled to simultaneous ICP was investigated. Different factors including the pH of the sample solution, the flow rates of sample loading and eluation, the acidity of eluent and different eluents were investigated and optimized. In comparison with continuous aspiration, the signal enhancement factors of eleven elements (Zn, Cu, Ni, V, Cr, Fe, Mn, Co, Pb, Cd and Al) were in the range of 6.4 to 13.5 for peak height (0.5 s) and 3.7 to 5.8 for peak area (15 s), respectively. The influences of matrix ions, such as Ca, Mg, Fe, Cu and NaCl were studied. Performance was demonstrated by simultaneous determination of seven (Zn, Cu, Ni, V, Cr, Fe, Mn) elements in a number of CRMs. Most results were satisfactory, except for iron and chromium. The possible reasons were discussed. Co, Pb, Cd and Al were not available in the simultaneous instrument. Therefore, only the analytical performance was measured for these elements by the sequential instrument.On leave from Shanghai Institute of Metallurgy, Academia Sinica, Shanghai, China 200050  相似文献   

13.
Phytopharmaceuticals containing Valerian are used as mild sleep-inducing agents. The elemental composition of 3 different marks of Valeriana officinalis roots commercially available in the Argentinian market, their teas, and a commercial tincture have been studied. The content of Al, Ca, Cd, Co, Cr, Cu, Fe, Li, Mn, Ni, Pb, V, and Zn was determined in phytopharmaceuticals by flame atomic emission/absorption spectrometry, electrothermal atomic absorption spectrometry, and ultrasonic nebulization coupled to inductively coupled plasma-optical emission spectrometry. Prior to analyses of the samples, a digestion procedure was optimized. The analytical results obtained for Fe, Al, Ca, and V in the solid sample study were within the range 100-1000 mg/kg, and for Mn, Zn, and Pb within the range 10-100 mg/kg. Cadmium was found at levels up to 0.0125 mg/kg.  相似文献   

14.
Zusammenfassung Für die folgenden 20 Elemente wurden die Grundlagen für eine halbquantitative Konzentrationsbestimmung mit Hilfe des Laser-Mikrospektralanalysators ermittelt, und zwar differenziert für Untersuchungen an oxidischen und an metallischen Materialien: Mg, Al, Si, Cr, Mn, Co, Ni, Cu, Zn, Ga, Ge, Pd, Ag, Cd, In, Sn, Sb, Pb, Bi, Fe bzw. Au.
Principles of semi-quantitative determination of 20 elements by laser-microspectroscopy
The principles for the determination of the following 20 elements by Laser-microspectroscopy have been investigated separately for oxidic and metallic materials: Mg, Al, Si, Cr, Mn, Co, Ni, Cu, Zn, Ga, Ge, Pd, Ag, Cd, In, Sn, Sb, Pb, Bi, Fe resp. Au.
  相似文献   

15.
The metal distribution of Cr, Mn, Fe, Cu, Zn, and Pb, and the elemental composition, morphology and relative abundance of particles have been evaluated in suspended matter of the Upper Course of the Lerma River in Mexico. The metal concentrations in the suspended matter decrease in the sequence: Fe > Mn > Zn > Cu = Cr > Pb. The Fe and Mn concentrations in the suspended matter are produced principally by natural contributions whereas the Cu, Zn, Cr, and Pb concentrations are produced principally by anthropogenic contributions. In general, the particle groups decrease in the following sequence: aluminosilicate > silica > sulphur > metals > calcium > manganese > iron > calcium carbonate.  相似文献   

16.
The distribution patterns and the organ-specific accumulation trends of 10 trace metals (iron, manganese, zinc, copper, chromium, nickel, cobalt, lead, cadmium and silver) and 4 major elements (sodium, potassium, calcium and magnesium) in 10 different tissues (heart, muscle, kidney, stomach, intestine, liver, gill, gonads, white skin and dark skin) of a benthic fish species (Solea senegalensis) from a densely populated coastal area affected by anthropogenic activities, the Bay of Cadiz (SW Spain), have been investigated. High variability of metal concentrations among tissues were found for Ca, Fe, Zn, Cu, Pb and Ag. Factor analysis was applied to study this variability. Five principal components were found explaining the 92.95% of the total variance and similarities in behavioural patterns of bioaccumulation were described. They associated Mg, Cr, Ni and Mn to intestine and stomach tissues (PC1), Ag, Cu and Cd to liver (PC2), Zn, K and Co to gonads (PC3), Na, Fe and Pb to gill, heart and kidney tissues (PC4) and Ca, Pb and Mn to gill and dark skin (PC5). The metallic concentration in the sediment and water was also studied. The pollution in this area was found moderate with outstanding values of Zn, Cu and Pb (average values of 139, 50.4 and 75.6?mg?kg?1, respectively) in sediment and dissolved Cu (average value of 2.5?µg?L?1). Metal bioconcentration trends followed the order Zn?>?Cu?>?Cd?>?Pb for dissolved metals in seawater, Cu?>?Zn?>?Cd?>?Pb?≈?Mn?>?Fe?≈?Ni?≈?Co for metals associated to particulate matter and Zn?≈?Cu?>?Cd?>?Mn?>?Co?≈?Fe?>?Ni?≈?Pb?>?Cr for metals in the sediment. Higher values were found for copper in liver, zinc in gonads and lead in gill, showing the relationship between biotic and abiotic environment. In addition, Cd bioconcentration factors were found high in liver and gill showing the sensitivity of sole to this metal even at low concentrations.  相似文献   

17.
Ten trace elements (Al, Cr, Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb) were determined in the dissolved ash of the edible part of wild mussels (28 samples) from a polluted site by electrothermal atomic absorption spectrometry. The distribution of the concentration of each element in the mussels was first investigated by means of a test of normality. The correlation matrix around the mean was used as a starting matrix for principal component analysis (PCA). Ten variables were reduced to two principal components, accounting for 77% of the total variance; Al, Cr, Mn, Fe, Zn, Cd and Pb are all positively associated with the first principal component and form a cluster of variables, indicating a common terrigenous origin. Comparison with 43 samples of unpolluted mussels from a nearby hatchery, on the basis of eight common variables (concentration of Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb; 71 samples) by using a two-dimensional plot of PC scores, allows the mussels from the two sites to be differentiated.  相似文献   

18.
Abstract

Mushrooms are efficient accumulators of essential and toxic elements. Although oyster (Pleurotus spp.) mushrooms are widely commercialized and consumed, few data exist regarding trace elements content and bioaccumulation in cultivated P. ostreatus and P. eryngii, while no data are available for P. nebrodensis. The contents of Al, As, Ba, Cd, Co, Cr, Cs, Cu, Fe, K, Mn, Na, Ni, Pb, Rb, Sr, V, and Zn were monitored using inductively coupled plasma-mass spectrometry (ICP-MS) and atomic emission spectrometry (AES) in P. ostreatus, P. eryngii, and P. nebrodensis mushrooms and their cultivation substrates that include wheat straw (WHS), grape marc (GMC), olive leaves (OLV), and two-phase olive mill wastes (OMW), separately or in mixtures. Bioaccumulation factors (BAFs) less than 0.3 were obtained for Al, Ba, Co, Cr, Fe, Mn, Ni, Pb, Sr, and V; BAFs exceeding 1 for K?>?Zn?>?Cd?>?Cr?>?Rb?>?As, while the BAFs for Na were less 0.7. Mushrooms grown on OLV and OMW presented lower BAFs than those grown on WHS and GMC for all elements except for K, Cd, and Cu. P. ostreatus was an effective accumulator for Cr, Fe, and Zn; P. eryngii for Al, Cs, Ni, and V; and P. nebrodensis for As and Cd. The estimated daily intakes (μg kg?1 body weight) from mushroom consumption were less than 0.010 for As, Cd, Co, Cs, Pb, and V, 0.010–0.10 for Ba, Cr, Ni, and Sr, 0.10–5.0 for Al, Cu, Fe, Mn, Rb, and Zn, 65–83 for Na, and 858–1030 for K. Overall, the mushrooms studied provide significant amounts of K, adequate amounts of Mn and Zn and low amounts of Na and toxic elements.  相似文献   

19.
考察了几种特色南药中重金属(Cd,Cr,Cu,Fe,Mn,Ni,Pb,Sr,Zn)的含量状况,并采用形态连续萃取法分析重金属在药材中的形态分布,研究了药材煎煮时药材中重金属的释放及煎煮过程对药材中重金属形态分布的影响。结果表明,几种南药中Cr,Pb,Zn的含量较高,且巴戟天中的重金属总量高于限量标准;原药材中Cr,Cu,Mn,Ni,Pb和Zn主要存在于有机态和残留态,Fe和Sr主要存在于残留态。煎煮使南药中大量重金属迁移到药汤中;药汤中Cu,Mn,Cr,Pb和Zn主要来自于其在药材中的可交换态、碳酸盐结合态和有机态,而药汤中Sr,Ni和Fe不仅包含其非残留态,更多来自于它们的残留态。为减少药汤中重金属,对于Cu,Mn,Cr,Pb和Zn既要控制在药材中的总量,且需降低它们在药材中的非残留态含量;对于Fe,Ni和Sr则主要是控制其在药材中的总量。  相似文献   

20.
Seventeen elements, Al, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, P, Pb, V, and Zn (macroelements and trace elements) were investigated by Atomic Spectrometries on a particular wild edible mushroom collected in the central region of Argentina during 2 different years in the same season. The metal content profile in Suillus granulatus samples is given. The found quantities of Na, K, Ca, Mg, Fe, P, V, and Al were 0.40, 10.84, 0.48, 0.30, 0.57, 4.24, 0.18, and 1.23 g/kg dry weight, respectively. The levels of Li, Cu, Zn, Cd, Co, Ni, Cr, and Mn were 0.98, 23.02, 22.30, 0.26, 0.16, 1.17, 0.90, and 28.75 mg/kg dry weight, respectively. Pb was not detected at the investigated levels. The results indicate that the levels of metals in the analyzed samples are not considered to be a health risk. In order to demonstrate the validity of our method, a recovery study was performed with acceptable results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号