首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The application of reversed-phase high-performance liquid chromatography to the analytical- and preparative-scale separation of sterols has been evaluated. The capacity factors, k', for a number of compounds chromatographed on a muBondapak C18 (LESS THAN 10 MUM) COLUMN ARE PRESENTED. C27, C28 and C29 sterols and also sterols differing in degree of unsaturation could be readily separated as their acetates in this system. The present reversed-phase chromatographic method is apparently not as selective as silver nitrate-silica gel thin-layer chromatography for the position of unsaturation in the sterol molecule.  相似文献   

2.
A convenient semi-preparative high-performance liquid chromatography (HPLC) method for separating a mixture of triterpenoids (alpha-amyrin, beta-amyrin, and lupeol) and their corresponding acetates from the swallow roots (Decalepis hamiltonii Wight and Arn), which are known to have potential bioactive properties, is described. The swallow roots are found to be one of the richest natural sources for these compounds. The hexane extract of the dried spent root on column chromatography yields mixtures (i.e., triterpenoids and their acetates) containing at least three compounds in each. These could not be further separated using the routine chromatographic techniques, such as classical column chromatography and preparative thin-layer chromatography using various solvent systems. Therefore, the optimal conditions are determined on reversed-phase HPLC for their separation and are characterized using spectral data, particularly by nuclear magnetic resonance with physical and chemical properties.  相似文献   

3.
Isocratic conditions are described for the separation, identification and quantitation of selected phenolic antioxidants and related compounds by high performance liquid chromatography on a reverse phase microparticulate ODS column. Mobile phases containing 0.05 M lithium perchlorate in aqueous methanol are used. Three detection systems: ultraviolet; fluorescence; and electrochemical detectors are connected in tandem. The use of these three detection systems in sequence as additional means for separation, identification, and quantitation is demonstrated. Other advantages of the system include speed of analyses and improved detection. The ? values and detector responses at 2 settings per detector for 12 compounds are reported.  相似文献   

4.
Ergosterol and stigmasterol are the most common phytosterols in the traditional Chinese medicine. They are two major sterol compounds in Anoectochilus roxburghii (wall) Lindl (A. roxburghii) and have been proved to have many important biological activities. A method by using high-speed counter-current chromatography (HSCCC) has been successfully developed for separation and purification of ergosterol and stigmasterol in A. roxburghii simultaneously in this paper. The optimum conditions used in this method were as follows: The two-phase solvent system consisted of n-hexane-ethylacetate-butanol-methanol-water (3.5:0.3:0.5:2.5:0.3, v/v); the rotation speed was 900 rpm; the flow rate of the lower phase was 1.5 mL/min. About 36.5 mg of ergosterol and 43.6 mg of stigmasterol were obtained from 100 g of A. roxburghii. The purity of ergosterol and stigmasterol was examined to be 92.0 and 95.5%, respectively, by using HPLC. The chemical structures of these components were identified by UV spectra, FT-IR, MS, (1) H-NMR and (13) C-NMR. The results demonstrated that high-speed counter-current chromatography was a feasible method to separate and purify ergosterol and stigmasterol from the herb. This separation and purification method was more effective than many other conventional techniques.  相似文献   

5.
Stroke is one of the most common diseases worldwide. Lactate dehydrogenase inhibitors are widely used in the treatment of ischemic stroke, with natural products considered a promising source of lactate dehydrogenase inhibitors. In this study, ultrafiltration liquid chromatography coupled with mass spectrometry was used for the screening and identification of lactate dehydrogenase inhibitors from Poria cocos . Five lactate dehydrogenase inhibitors were selected: dehydropachymic acid, pachymic acid, dehydrotrametenolic acid, trametenolic acid, and eburicoic acid. The inhibitors were extracted and isolated with purities of 96.75, 98.15, 97.25, 95.46, and 94.88%, respectively, by using a new “hyphenated” strategy of microwave‐assisted extraction coupled with counter‐current chromatography and centrifugal partition chromatography by a two‐phase solvent system of n‐hexane/ethyl acetate/ethanol/water at the volume ratio 0.965:1.000:0.936:0.826 v/v/v/v. The bioactivity of the isolated compounds was assessed using the 3‐(4,5‐dimethylthiazol‐2‐yl)‐2,5‐diphenyltetrazolium bromide assay in PC12 cells. The results also showed that the hyphenated technique of microwave‐assisted extraction coupled with counter‐current chromatography and centrifugal partition chromatography was an efficient method for the continuous extraction and online isolation of chemical constituents from medicinal herbs. Furthermore, the research route based on the activity screening, extraction, separation, and activity verification of the compounds offered advantages of efficiency, orientation, and objectivity.  相似文献   

6.
Abstract

A method for simultaneous determination of major bile acids in human bile is described. The unconjugated, glycine- and taurine-conjugated bile acids are extracted with Sep-pak C18 and separated into groups by ion-exchange chromatography on a lipophilic gel. Subsequently, resolution of each group into ursodeoxycholate, cholate, chenodeoxycholate, deoxycholate and lithocholate is attained into two stages by high-performance liquid chromatography on a Radial-PAK A column. First, 0.3% ammonium phosphate (pH 7.7)/acetonitrile (19:8, v/v) is used for separation of the latter three as a mobile phase. Ursodeoxycholate and cholate are efficiently separated in 0.3% ammonium phosphate (pH 7.7)/acetonitrile (23:8, v/v). The present method is applicable to quantitation of bile acids in human bile with satisfactory accuracy and precision.  相似文献   

7.
A procedure is described for the separation of Vitamin D and related compounds by gas-liquid chromatography using flame ionization detection. The method involves a two-step conversion: isomerization to the corresponding (all trans) isotachysterol(s) followed by methyl ether derivatization of the alcohol group(s). The procedure provides a means for identification as well as a possible basis for quantitation of Vitamin D and analogs.  相似文献   

8.
The extensive use of CE for the analysis of amino acids has been well documented in a series of research articles and reviews. Aim of this report is to address the attention of the reader on the recent advances of micellar electrokinetic chromatography for the separation and determination of these analytes. Enhancements in selectivity of this technique through the use of pseudostationary phases containing mixed micelles, polymers, and chiral selectors are presented. Selected applications concerning separation and quantitation of even minute amounts of amino acids in: (i) biological fluids; (ii) microdialysates; (iii) plant cells; (iv) food stuff; and (v) pharmaceutical formulations have also been covered. Advantages of MEKC over other techniques for the amino acid analysis have been underlined.  相似文献   

9.
A method of microwave-assisted extraction coupled with high-speed counter-current chromatography was established for separation and purification of isopimpinellin, pimpinellin and phellopterin from Toddalia asiatica (L.) Lam. The conditions of MAE including the extraction solvent, size of sample, solid/liquid ratio, extraction temperature and extraction time were optimized by a mono-factor test. That is, 2.0 g dried powder of T. asiatica (L.) Lam of 0.30-0.15 mm size was extracted with 20 mL (solid/liquid ratio of 1:10, g/mL) methanol under 50 °C for 1 min. The crude extract was separated and purified by high-speed counter-current chromatography with hexane-ethyl acetate-methanol-water (5:5:5.5:4.5, v/v/v/v) solvent system. 0.85 mg/g of isopimpinellin, 2.55 mg/g of pimpinellin and 0.95 mg/g of phellopterin were obtained from original sample in one-step within 240 min, the purity determined by high performance liquid chromatography was 95.0%, 99.1% and 96.4%, respectively. Their chemical structures were further identified by mass spectroscopy and nuclear magnetic resonance spectroscopy. The results demonstrated that microwave-assisted extraction coupled with high-speed counter-current chromatography was a feasible, economical and efficient technique for rapid extraction, separation and purification of effective compounds from natural products.  相似文献   

10.
Chemical and physiological properties are related to individual or bioactive compounds such as essential oils, terpenoids, flavonoids, volatile compounds and other chemicals which are present in natural products in low concentrations (e.g. ppm or ppb). For many years, classical separation, chromatographic and spectrometric techniques such as high performance liquid chromatography (HPLC), gas chromatography (GC), liquid chromatography (LC) and mass spectrometry (MS) have been used for the elucidation of isolated compounds from different matrices. Hence, the use of standard separation, chromatographic and spectrometric methods was found useful in chemical and both plant and animal physiology studies, for fingerprinting and comparing natural and synthetic samples, as well as to identify single active compounds. It has been generally accepted that a single analytical technique will not provide sufficient visualization of the metabolome, hence holistic techniques are needed for comprehensive analysis. In the last 40 years near infrared (NIR) spectroscopy became one of the most attractive and used methods of analyzing agricultural related products and plant materials which provide simultaneous, rapid and non-destructive quantitation of major. This technique has been reported to determine other minor compounds in plant materials such as volatile compounds and elements. The aim of this short review is to describe some recent applications of NIR spectroscopy combined with multivariate data analysis for high throughput screening of metabolites with an emphasis on food and medical applications.  相似文献   

11.
A cryogenic preconcentration/high-resolution gas chromatographic technique has been developed for the rapid, simultaneous quantitation of C1–C4 organic nitrates and halocarbons in ambient air. Whole-air samples are collected in TedlarTM bags by an evacuated-chamber method. Samples were stable in 0.010-cm-thick bags for 24 h if they were immediately stored in a freezer at −25°C. Analytes in a 50-cm3 air sample were efficiently preconcentrated on fused-silica beads at −180°C and thermally desorbed at 30°C. High-resolution gas chromatography with a cross-linked polydimethylsiloxane fused-silica capillary column and an electron-capture detector were used for separation and quantitation of the analytes. An analysis time of about 12 min was facilitated by sample cryofocusing at −180°C and oven temperature programming. Recoveries of the analytes by the evacuated-chamber method were better than 95%. The sensitivity of the technique for sample volumes of 50 cm3 is in the sub-parts-per-trillion by volume (ppt[v]) range for many of the analytes, with an average precision of about ±5% for analytes at levels of about 10 ppt(v).  相似文献   

12.
A novel method was developed for the analysis of molecular species in neutral lipid classes, using separation by normal phase high-performance liquid chromatography, followed by detection by evaporative light-scattering and electrospray ionization tandem mass spectrometry. Monoacid standards, i.e. sterol esters, triacylglycerols, fatty acids, diacylglycerols, free sterols and monoacylglycerols, were separated to baseline on microbore 3 μm-silica gel columns. Complete or partial separation of molecular species in each lipid class permitted identification by automatic tandem mass spectrometry of ammonium adducts, produced via positive electrospray ionization. After optimization of the method, separation and identification of molecular species of various lipid classes was comprehensively tested by analysis of neutral lipids from the free lipid extract of maize flour.  相似文献   

13.
This work presents a high-performance liquid chromatography (HPLC) method for the quantitation of glucosamine in chitin. The method includes an acid hydrolysis of chitin. The chromatographic separation is achieved using a Hypersil ODS 5-microm column (250 x 4.6 mm) at 38 degrees C, with precolumn derivatization with 9-fluorenylmethyl-chloroformate and UV detection (lambda = 264 nm). The mobile phase is a mixture of mobile phase A [30 mM ammonium phosphate (pH 6.5) in 15:85 methanol-water (v/v)], mobile phase B [15:85 methanol-water (v/v)], and mobile phase C [90:10 acetonitrile-water (v/v)], with a flow rate of 1.2 mL/min. The HPLC method proposed showed adequate repeatability (relative standard deviation, 5.8%), accuracy (92.7% recovery), and sensitivity, with a detection limit of 2 microg/mL. The method is successfully applied to the quantitation of glucosamine for the determination of the purity of chitin from shrimp waste.  相似文献   

14.
Counter-current chromatography is a new liquid-liquid partition chromatography without using solid support. Recently, the technique has been remarkably improved in both partition efficiency and separation time. In this paper the capability of this high-speed counter-current chromatography was demonstrated on separation of two sets of samples obtained from medicinal herbs: a synthetic mixture of 3'-hydroxygenkwanin, luteolin and apigenin was separated on a two-phase solvent system composed of chloroform-methanol-water (4:3:2, v/v/v) and a crude ethanol extract from Anisodus tangulicus (Maxin) Pasch on chloroform-0.07 M sodium phosphate (pH 6.4) (1:1, v/v). In the light of chromatograms obtained from these samples, advantages of high-speed counter-current chromatography over other chromatographic methods were discussed in terms of partition efficiency, peak resolution, separation time, sample loading capacity, etc.  相似文献   

15.
An isocratic reversed-phase high-performance liquid chromatography (HPLC) method is developed and validated for the quantitation of 3,4-methylenedioxymethamphetamine (MDMA) in tablets. The chromatographic separation is achieved with potassium phosphate buffer (pH 3.2)-acetonitrile (9:1, v/v) as mobile phase, a Chromspher B column, and UV detection at 210 nm. The calibration curve is linear from 1.4 to 111 microg/mL. The percent relative standard deviation for intra- and interday precision studies is 2.7% each. The measurement uncertainty is estimated to 9%. The method is specific and successfully used for routine quantitation of MDMA in tablets.  相似文献   

16.
A new method for the preparation and separation of alditol acetates from neutral sugars has been applied to aminosugars. Reduced aminosugars were rapidly acetylated using 1-methylimidazole as the catalyst without removal of borate formed during reduction. The alditol acetates were separated by glass capillary gas chromatography on Silar 10C. The alditol acetates of aminosugars had retention times much longer than those of neutral sugars. However, the alditol acetates of the deamination products of aminosugars had shorter retention times and were resolved from those of neutral sugars. This method was used for the simultaneous detection of neutral and aminosugars in acid hydrolysates of chitin and the glycoproteins, ovalbumin and peroxidase.  相似文献   

17.
A high performance liquid chromatographic (HPLC) method has been developed to permit the rapid comparison of acidic polysaccharides of diverse compositions and the sensitive determination of their constituents. It is based on two combined analyses of the polysaccharide hydrolysates--a separation of the released compounds by ion-moderated partition chromatography with UV detection at two wavelengths and a separation of the sugar dansylhydrazine derivatives by reversed phase chromatography. The former permits identification and quantitation of uronic and carboxylic acids, the latter permits more sensitive and specific determination of the neutral aldoses. Some bacterial exopolysaccharides have been used to demonstrate the validity of this HPLC procedure for the chemical characterization of uronic acid-containing polysaccharides. This method appears to be useful for studying capsular polysaccharides, which are involved in the evasion of phagocytosis by pathogenic bacteria.  相似文献   

18.
A fast and convenient method based on coupled thin-layer chromatography (TLC) with Fourier transform infrared (FTIR) microscopy has been established for separation and identification of multicomponent mixtures. In this study, the method was developed and consummated with more perfect TLC spots transferral process and consistent FTIR testing conditions. A newly developed technique, solid-phase extract (SPE) was introduced for sample pre-treatment instead of using traditional column chromatography. It is a new field for SPE that has already been widely applied in many other fields. It not only overcomes the backwards (low separation efficiency, time consuming and solvent consumption) of column chromatography but also makes it much easier to choose an optimum TLC sheet and to set suitable TLC loading. With all the above-mentioned modifications and supplements, the analytical method of coupled TLC with FTIR microscopy for separation and identification of multicomponent mixtures becomes more convenient and more efficient. In addition, a very complex sample (a die-cast release agent) was used as an example to demonstrate the technique.  相似文献   

19.
The first analytical method is developed and validated for the simultaneous determination of imipenem and sulbactam in mouse plasma. Sample treatment is based on plasma stabilization with 4-(2-hydroxyethyl)piperazine-ethanesulfonic acid (HEPES) (0.5 mol/L; pH 7.0)-water-ethylene glycol (2:1:1, v/v/v), precipitation of plasma proteins with acetonitrile, centrifugation, evaporation, and reconstitution with borate buffer. Analytical determination is carried out by high-performance liquid chromatography with diode-array detection. Chromatographic separation is achieved within 11 min on a C(18) column by gradient elution with borate buffer (0.1 mol/L, pH 7.2) and methanol. Imipenem and sulbactam are monitored at 295 and 230 nm, respectively. The overall interday accuracy is in the range of 95% to 100% and from 98% and 101% for imipenem and sulbactam, respectively. Interday precision is below 8% and 4% for imipenem and sulbactam, respectively. Limits of quantitation of imipenem and sulbactam are 0.05 and 1.0 microg/mL, respectively. The mean extraction recoveries are 94.5% and 94.2% for imipenem and sulbactam, respectively. The described method allows an accurate, simple, and rapid identification and quantitation of imipenem and sulbactam in mouse plasma. This method is applied to the analysis of imipenem and sulbactam in mouse plasma after drug administration.  相似文献   

20.
This paper describes a novel method of sample preparation for the determination of trace concentrations of polycyclic aromatic hydrocarbons (PAHs) in high-boiling petroleum products. Limits of quantitation of the investigated PAHs in materials of this type range from tens of nanograms per kilogram to <20 μg/kg. The studies revealed that in order to separate most of interferences from the analytes without a significant loss of PAHs, it is necessary to use size exclusion chromatography as the first step of sample preparation, followed by adsorption using normal-phase liquid chromatography. The use of orthogonal separation procedure described in the paper allows the isolation of only a group of unsubstituted and substituted aromatic hydrocarbons with a specific range of molar mass. The lower the required limit of quantitation of PAHs, the larger is the scale of preparative liquid chromatography in both steps of sample preparation needed. The use of internal standard allows quantitative results to be corrected for the degree of recovery of PAHs during the sample preparation step. Final determination can be carried out using HPLC-FLD, GC-MS, or HPLC-UV–VIS/DAD. The last technique provides a degree of identification through the acquired UV–VIS spectra.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号