首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A calibration methodology developed for custom-made heat flux sensors used for the investigation of hydrothermal spallation drilling is presented. An air jet stagnation convection calibration system allowing independent control of jet velocity and temperature, cooling water flow and temperature, stand off distance, and nozzle diameter was built. A thermopile device was used as reference heat flux sensor. Air jets with velocities up to 400 m/s, exit temperatures of 760°C, and heat fluxes up to 0.6 MW/m2 can be reached. The standard deviation of a reference heat flux measurement is below 2%, and overall uncertainty achieved is less than 5.5%.  相似文献   

2.
Pool boiling heat transfer and quench front propagation were investigated during quenching of cylindrical stainless steel rodlets in subcooled water. The degree of subcooling was varied from 0°C (saturated) to 40°C at an increment of 10°C at atmospheric pressure. The results showed that the increase of degree of subcooling accelerates quenching, with the total quenching time being shortened from 90 second (saturated) to 12 second (subcooled by 40°C). As revealed by the boiling curves that were obtained via solving an inverse heat conduction problem in cylindrical coordinates, boiling heat transfer is enhanced significantly for all boiling modes with raising the degree of subcooling. At the highest degree of subcooling of 40°C, the critical heat flux is improved by nearly 300% as compared to that in saturated water. In addition, the rewetting temperature (i.e., Leidenfrost point) was found to increase as a nearly linear function of the degree of subcooling. The quench front was observed to propagate upward from the bottom of the rodlet, which is accelerated noticeably with increasing the degree of subcooling. The average quench front velocity was shown to agree well with the predicted value of an existing theoretical model that was modified to take the influence of subcooling into consideration.  相似文献   

3.
In the current study, a hot moving steel plate of 6 mm thickness with an initial temperature of 900°C has been considered for jet impingement cooling. The experiment has been designed with the help of Design of Expert software to optimize the process parameters based on the highest cooling rate. The various subsurface transient temperature histories have been measured during the cooling process. The surface heat flux and surface temperature were calculated with the help of a commercial inverse heat transfer solver called INTEMP. The experimental result has been presented in terms of cooling rate and critical heat flux.  相似文献   

4.
In this study, heat transfer coefficients and pressure drops of R-134a inside round and flat tubes are investigated experimentally with mass flux of 450, 550, and 650 kg m?2 s?1 at saturation temperatures of 35°, 40°, and 45°C. The effects of mass flux and saturation temperature on heat transfer coefficient and pressure drop are examined. The maximum enhancement factor and pressure drop penalty are obtained by flat tube (FT-2) up to 2.101 at 450 kg m?2 s?1 and 3.01 at 650 kg m?2 s?1, respectively. The correlation for flat tubes is proposed to predict the heat transfer coefficient within ±20% error.  相似文献   

5.
陆海波  刘伟强 《中国物理 B》2012,21(8):84401-084401
The three-dimensional Navier-Stokes equation and the k-ε viscous model are used to simulate the attack angle characteristics of a hemisphere nose-tip with an opposing jet thermal protection system in supersonic flow condition. The numerical method is validated by the relevant experiment. The flow field parameters, aerodynamic forces, and surface heat flux distributions for attack angles of 0°, 2°, 5°, 7°, and 10° are obtained. The detailed numerical results show that the cruise attack angle has a great influence on the flow field parameters, aerodynamic force, and surface heat flux distribution of the supersonic vehicle nose-tip with opposing jet thermal protection system. When the attack angle reaches 10°, the heat flux on the windward generatrix is close to the maximal heat flux on the wall surface of the nose-tip without thermal protection system, thus the thermal protection is failure.  相似文献   

6.
The objective of the current research deals with the experimental study of an air-atomized spray with surfactant-added water, cooling a 12-mm-thick AISI-1020 stationary steel plate at three different initial surface temperatures (400°C, 600°C, and 900°C). Furthermore, the effects of surfactant concentration and airflow rate on the cooling rate have been investigated. The surface heat flux and surface temperature show a significant improvement in cooling for all three cases of initial surface temperatures when the air-atomized spray was used with surfactant-added water.  相似文献   

7.
A hot aluminum alloy AA6082 and nickel disc of 560°C and 850°C was cooled by water spray of various spray flux under different condition of experiment. Temperature history was recorded with use of an infrared camera. During the quenching process, it was observed that the area with no apparent boiling and the outer annular region with vigorous liquid boiling have formed the boiling region. The width of the boiling region is essential as the maximum heat flux point is within the boiling region. Boiling width increases with initial temperature but decreases with water subcooling, spray flux and salinity.  相似文献   

8.
In this paper, the dynamics and flow behaviour of an atmospheric argon plasma jet was studied in the new nozzle structure similar to the surface dielectric barrier discharge (SDBD) using the Schlieren imaging method. The effect of plasma jet driven by repetitive high-voltage microsecond pulses with low-frequency sinusoidal bias was measured qualitatively in a single mirror Schlieren optical system. The enhancement of plasma jet length and cross-section of plasma jet with surface in this condition is due to highly turbulent flow of argon plasma jet in this structure. This study revealed the important role of SDBD structure and modulated electric field on the behaviour of plasma jet in a high diameter nozzle. In practice, this technique allows us to increase the jet length of the nozzle output to 5 cm and under these conditions, the diameter of the plasma jet cross-section is increased to 8 mm, without increasing the electrical power consumption. Eventually, the hydrophilicity of the surface is also measured by the contact angle of a water droplet that decreases from 78° to 8° after surface treatment, implying we were able to reach a super-hydrophilic surface with this plasma jet structure.  相似文献   

9.
The article provides results of experimental investigation of a fresh water motion in a flume with limited dimensions at lateral heating. The initial water temperature in the flume ranged from 0 to 22 °C. It is shown that there are qualitative changes of the motion picture in the vicinity of initial temperature in the flume equal to the one at which water has maximal density (approximately 4 °C). At an initial temperature in the flume exceeding or equal to 4 °C, the heated water propagates in the form of a relatively thin surface jet, and at jet reflection from the flume end walls the heated water is accumulated only in the upper layer. When the initial temperature in the flume is below 4 °C the convective instability develops. A part of the heated water sinks to the bottom. The paper provides respective illustrations and quantitative data on the distribution of temperature and velocity.  相似文献   

10.
《光谱学快报》2013,46(6):565-579
Abstract

Enamel and dentin are composed, respectively, of 3 wt% and 10 wt% of water, which exhibits different features in the tissues: loosely and tightly bound water. The objective of this study is to clarify by infrared spectroscopy, the different features of the water in heated (100–1000°C) hard dental tissues (enamel and dentin). The water band between 3800 cm?1 and 2500 cm?1 was analyzed by infrared spectroscopy. The area dependence of the water band with temperature was compared with the Arrhenius equation in two regions (100–400°C and 700–1000°C). The activation energy was determined for these two regions, and similar values were observed for both tissues. For enamel we obtain ?4.1±0.2 kJ/mol at 100–400 °C and ?63±9 kJ/mol at 700–1000°C; for dentin ?4.1±0.2 kJ/mol at 100–400°C and ?60±11 kJ/mol at 700–1000°C. The water loss changes the color of the tissues, hydroxyapatite crystallographic parameters, and produce ESR signals. These changes were discussed and compared with the results observed in this work and after laser irradiation. We conclude that these two activation energies could be assigned to the adsorbed (loosely bound) and trapped (tightly bound) water.  相似文献   

11.
This article directly investigates the effect of a cooling medium's coolant temperature on the condensation of the refrigerant R-134a. The study presents an experimental investigation into condensation heat transfer, vapor quality, and pressure drop of R-134a flowing through a commercial annular helicoidal pipe under the severe climatic conditions of a Kuwait summer. The quality of the refrigerant is calculated using the temperature and pressure obtained from the experiment. Measurements were performed for refrigerant mass fluxes ranging from 50 to 650 kg/m2s, with a cooling water flow Reynolds number range of 950 to 15,000 at a fixed gas saturation temperature of 42°C and cooling wall temperatures of 5°C, 10°C, and 20°C. The data shows that with an increase of refrigerant mass flux, the overall condensation heat transfer coefficients of R-134a increased, and the pressure drops also increased. However, with the increase of mass flux of cooling water, the refrigerant-side heat transfer coefficients decreased. Using low mass flux in a helicoidal tube improves the heat transfer coefficient. Furthermore, selecting low wall temperature for the cooling medium gives a higher refrigerant-side heat transfer coefficient.  相似文献   

12.
Thermal performance of a latent heat storage unit is evaluated experimentally. The latent heat thermal energy storage system analyzed in this work is a shell-and-tube type of heat exchanger using paraffin wax (melting point between 58°C and 60°C) as the phase change material. The temperature distribution in the phase change material is measured with time. The influence of mass flow rate and inlet temperature of the heat transfer fluid on heat fraction is examined for both the melting and solidification processes. The mass flow rate of heat transfer fluid (water) is varied in the range of 0.0167 kg/s to 0.0833 kg/s (1 kg/min to 5 kg/min), and the fluid inlet temperature is varied between 75°C and 85°C. The experimental results indicate that the total melting time of the phase change material increases as the mass flow rate and inlet temperature of heat transfer fluid decrease. The fluid inlet temperature influences the heat fraction considerably as compared to the mass flow rate of heat transfer fluid during the melting process of the phase change material.  相似文献   

13.
Ground source heat pump (GSHP) systems have been applied widely because of their environmental-friendly, energy-saving, and sustainable nature. In this work, heat transfer performance of a single vertical small-scale U-shaped tube ground heat exchanger under hot climatic condition is addressed considering the influences of inlet water temperature, Reynolds number, and backfill materials (raw soil; soil–polyacrylamide (PAM) blend (0.27% blending ratio for PAM). The backfill materials had an important effect on the heat transfer of the ground heat exchanger. At an inlet water temperature of 45°C and Reynolds numbers of 3104 and 4656, the temperature drops of water in the tube in the soil–PAM blend increased by about 0.3 and 0.4°C compared to that in the raw soil. Within Reynolds number from 3104 to 6208, the average surface heat transfer coefficients of the water in the tube in the soil–PAM blend and raw soil at an inlet water temperature of 45°C were 411 and 231 W m?2K?1, respectively. The results suggest that adding the PAM into soil can be an effective manner for enhancing the heat transfer of the ground heat exchanger. The dimensionless surface heat transfer correlation of the water in the U-tube heat exchanger in the soil–PAM blend was obtained. The model could better fit the experimental data within ±10% deviation.  相似文献   

14.
Spray cooling is an effective tool to dissipate high heat fluxes from hot surfaces. This article thoroughly investigates the effect of thickness of a hot stainless steel plate on the cooling time, cooling rate, heat flux, and heat transfer coefficient under constant mass flow rate maintained at 1 MPa using water as the coolant. Cylindrical samples of stainless steel with constant diameter (D = 25 mm) and thickness (δ = 7.5, 12, 16.5, and 21 mm) were used in the present study. Critical droplet diameter to achieve an ultra-fast cooling rate of 300°C/s was estimated by using an analytical model for samples of varying thicknesses. The analytical model (one side spray cooling) showed good agreement with experimental results with a relative error of 3.2% in the plate thickness range of 1–12 mm. An increasing trend in maximum heat flux was found with increasing thickness of the plate. Maximum heat flux as high as 1,800 kW/m2 was achieved for a 21-mm-thick sample. Heat transfer coefficients in the range 0.092–96.24 kW/m2K, 0.111–98.9 kW/m2K, 0.074–63.4 kW/m2K, and 0.127–55.63 kW/m2K were reported for sample of varying thicknesses in the present study. Limited published work is available with reference to water spray cooling dynamics and thickness of stainless steel plate. Therefore, the present study focuses on the correlation between the thickness of the plate and spray dynamics of water spray cooling.  相似文献   

15.
水喷射淬冷高温壁面的传热实验研究   总被引:9,自引:1,他引:8  
本文采用直接表面温度测量的方法对水喷射高温壁面的传热过程进行实验研究.系统地研究了射流出口速度、冷却水过冷度、喷嘴至加热面的间距、初始壁温以及水喷雾的流量密度等参数对淬冷表面的膜态沸腾、最小临界点、过渡沸腾、最大临界点等传热过程的影响,给出了有关实验结果,分析了它们的特点。  相似文献   

16.
Summary This note presents estimates of hourly averages of insolation, net radiation and soil heat flux during daytime from solar-elevation angle and routine weather data on cloud cover and screen level air temperature using a formulation procedure generally adopted in surface layer parametrisation schemes. The estimation procedure employs commonly used forms of empirical relationships and the estimates are compared with the concurrent field observations at Trombay site in Bombay (19.1° N, 72.8° E) India. Wherever possible site-specific empirical coefficients are derived. Using the observed insolation, the net radiation and soil heat flux are respectively estimated within ±18% and ±14% of their observed values. Estimated insolation was found to be within ±37% of the observed values and, when used to derive the fluxes, the uncertainty increases to ±25% and ±27%, respectively.  相似文献   

17.
使用 ANSYS FLUENT 软件和 RNG k-ε 湍流模型分别研究了十字形、内十字形和花形结构的螺旋喷 嘴内部流动特性和耦合面换热特性。模拟结果研究表明,螺旋角 θ 越小喷嘴出口速度越高,喷出的水流更集中, 水流运动轨迹越清晰且规律越明显。同一工况下,θ=30°的花形喷嘴的换热效率和换热均匀性均优于其余两种喷嘴的值;耦合面努塞尔数 Nu 最大值会随着雷诺数 Re 不断增加而逐渐远离射流中心处(r/dj=0,dj 为喷嘴当量直径); 随着靶距 H 逐渐增大,Nu 逐渐减小,旋流效果逐渐减弱。当 H=2dj、4dj 时,Nu 最大值位于 r/dj=1 处;当 H=6dj 时,Nu 最大值位于射流中心处。  相似文献   

18.
The solution casting technology was applied to manufacture thin polymer films (~?20–30 μm) from the ionomer solution of perfluorinated polymer with short side chains (an analogue of the commercial polymer Aquivion®). The influence of annealing temperature on the mechanical properties (elastic limit), proton conductivity, and heat capacity was investigated. The elastic limit, glass transition temperature, and proton conductivity of the samples were found to reach their maximum values at the annealing temperature 170?±?5 °C. Comparative studies of membrane-electrode assemblies (MEA) using the commercial (Nafion NR212) and solution-casted membranes were carried out. MEA with optimized Aquivion-type membranes showed satisfactory values of fuel crossover and maximum output power. The results of the conducted studies show that the prepared Aquivion-type membranes are very promising for practical application in MEA.  相似文献   

19.
D. Deng  Q. Huang  W. Wan  W. Zhou  Y. Lian 《实验传热》2013,26(6):811-832
Flow boiling pressure drop and flow instabilities of Ω-shaped reentrant copper micro-channels were experimentally explored. Tests were conducted in deionized water and ethanol at inlet subcoolings of 10°C and 40°C, mass fluxes of 125–300 kg/m2·s, and a wide range of heat fluxes and exit vapor qualities. The operational parameters effects, i.e., heat flux, mass flux, inlet subcooling, and coolants, on pressure drop and flow instabilities were systematically explored. The two-phase pressure drop of reentrant micro-channels were found to generally increase monotonically with increasing heat fluxes and exit vapor qualities. Nevertheless, the roles of mass flux and inlet subcooling were dependent on the test coolant.  相似文献   

20.
Ultrasonic velocities in aqueous solutions of acetamide, dimethyl urea andβ-alanine at different concentrations in the temperature range of about 60°C to 80°C have been measured using an interferometer technique with an accuracy of ±0.003%. The temperature corresponding to velocity maximum at different concentrations is evaluated with an accuracy of ±0.2°C. The results are discussed in the light of the structure-breaking property of these substances in water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏