首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Jeong T  Lee HK  Jeong DC  Jeon S 《Talanta》2005,65(2):543-548
PVC membrane electrodes for lead ion based on N,N’-bis(salicylidene)-2,6-pyridinediamine as membrane carrier were prepared. Among their membranes, a membrane electrode (m-3) containing o-NPOE as a plasticizer and 50 mol% additive displays an excellent Nernstian response (29.4 mV/decade) and the limit of detection of −log a (M) = 6.04 to Pb2+ in Pb(NO3)2 solutions at room temperature. It has a rapid response time within 10 s over the entire concentration range. The proposed electrode revealed good selectivity and response for Pb2+ over a wide variety of other metal ions in a pH 5.0 buffer solutions, and good reproducibility of base line in subsequent measurements.  相似文献   

2.
A new PVC membrane electrode for manganese(II) ion based on a recently synthesized Schiff base of 5-[(4-nitrophenylazo)-N-hexylamine]salicylaldimine is reported. The electrode exhibits a Nernstian response for Mn2+ ions over a wide concentration range (4.0 × 10−7 to 1.8 × 10−2 mol L−1) with a slope of 30.1 (±1.0). The limit of detection is 1.0 × 10−7 mol L−1. The electrode has a fast response time (∼10 s), a satisfactory reproducibility and relatively long life time. The proposed sensor revealed good selectivities over a wide variety of other cations include hard and soft metals. This electrode could be used in a pH range of 4.5-7.5. It was used as an indicator electrode in potentiometric titration of manganese(II) ions with EDTA solution.  相似文献   

3.
Manganese(II) complex of (E)-2-(hydroxyl-5-methoxybenzylideneamino) phenol was synthesized and used as a suitable Mn(II) – selective membrane in PVC matrix. The plasticized membrane sensor exhibits a nersian response for Mn(II) ions over a wide concentration range of 6 × 10?6–2 × 10?2 M with slope of 29 ± 1 mV per decade. It has a response time of <11 s and can be used for 2 months without any measurable divergence in potential. The response of the proposed sensor is independent of pH between 4 and 9.5. The proposed sensor shows a fairly good discriminating ability towards Mn(II) in comparison with some hard and soft metals. The electrode was used in the determination of Mn(II) in aqueous solutions and as an indicator electrode in potentiometer titration of manganese ions against EDTA.  相似文献   

4.
N,N′,N″,N′′′-1,5,8,12-tetraazadodecane-bis(salicylaldiminato)(H2L) has been used as ionophore for preparing Mn2+ selective sensor. Membranes of different composition with regard to ratio of H2L:PVC:NPOE:NaTPB have been prepared and investigated. The best performance was obtained with the membrane of composition 10:150:150:10 (H2L:PVC:NPOE:NaTPB) (w/w; mg). This membrane generated linear potential response in the concentration range of 5.0 × 10−6 to 1.0 × 10−1 M with a Nernstian slope of 30.0 mV/decade of activity and fast response time (10 s). Hydrogen ion does not effect to the performance of sensor in the pH range 3.0-6.5. The sensor was found to be sufficient selective for Mn2+ over a number of alkali, alkaline and heavy metal ions and could therefore be used for the determination of manganese in various samples by direct potentiometry.  相似文献   

5.
A polyvinyl chloride (PVC) based membrane sensor for cerium ions was prepared by employing N,N′-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine as an ionophore, oleic acid (OA) as anion excluder and o-nitrophenyloctyl ether (o-NPOE) as plasticizer. The plasticized membrane sensor exhibits a Nernstian response for Ce(III) ions over a wide concentration range (1.41 × 10−7 to 1.0 × 10−2 M) with a limit of detection as low as 8.91 × 10−8 M. It has a fast response time (<10 s) and can be used for 4 months. The sensor revealed a very good selectivity with respect to common alkali, alkaline earth and heavy metal ions. The response of the proposed sensor is independent of pH between 3.0 and 8.0. It was used as an indicator electrode in potentiometric titration of fluoride, carbonate and oxalate anions and determination of cerium in simulated mixtures.  相似文献   

6.
《Analytical letters》2012,45(15):2411-2429
Abstract

A nickel(II) [Ni(II)] ion-selective electrode was prepared by incorporating a new N-S Schiff base ligand, glyoxal-bis(S-benzyldithiocarbazate) (GBSB), as a neutral carrier into the PVC matrix. The proposed electrode exhibits an excellent near-Nernstian response for Ni2+ ions, ranging from 2.8 × 10?7 to 1.0 × 10?1 mol/L with a detection limit of 1.2 × 10?7 mol/L and a slope of 31.9 ± 0.3 mV/dec in pH 4.0 nitrate buffer solution at 25°C. It has an appropriate response time and suitable reproducibility and can be used for at least 3 months. The operational pH range of the proposed electrode is 4.0–7.5. The response mechanism is discussed in view of the alternating current (AC) impedance technique. In addition, the electrode was successfully used as an indicator electrode in potentiometric titration of Ni2+ ion and in the direct determination of Ni2+ ion in milk power and chocolate samples.  相似文献   

7.
The two chromium chelates of Schiff bases, N-(acetoacetanilide)-1,2-diaminoethane (L1) and N,N′-bis(acetoacetanilide)-triethylenetetraammine (L2), have been synthesized and explored as neutral ionophores for preparing poly(vinylchloride) (PVC) based membrane sensors selective to Cr(III). The addition of lipophilic anion excluder (NaTPB) and various plasticizers viz. o-Nitrophenyloctyl ether (o-NPOE), dioctylpthalate (DOP), dibutylphthalate (DBP), tris(2-ethylhexyl)phosphate (TEHP), and benzyl acetate (BA) have found to improve the performance of the sensors. The best performance was obtained for the membrane sensor having a composition of L1:PVC:DBP:NaTPB in the ratio 5:150:250:3 (w/w). The sensor exhibits Nernstian response in the concentration range 8.9 × 10−8 to 1.0 × 10−1 M Cr3+ with limit of detection 5.6 × 10−8 M. The proposed sensor manifest advantages of relatively fast response (10 s) and good selectivity over some alkali, alkaline earth, transition and heavy metal ions. The selectivity behavior of the proposed electrode revealed a considerable improvement as compared to the best previously PVC-membrane electrode for chromium(III) ion. The potentiometric response of the proposed sensor was independent of pH of the test solution in the range of 2.0-7.0. The sensor has found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 3 months. The proposed electrode was used as an indicator electrode in potentiometric titration of chromium ion with EDTA and in direct determination in different water and food samples.  相似文献   

8.
A new polyvinyl chloride (PVC) membrane electrode that is highly selective to Hg(II) ions was prepared by using bis[5-((4-nitrophenyl)azo salicylaldehyde)] (BNAS) as a suitable neutral carrier. The sensor exhibits a Nernstian response for mercury ions over a wide concentration range (5.0×10−2-7.0×10−7 M) with a slope of 30±1 mV per decade. It has a response time of <10 s and can be used for at least 3 months without any measurable divergence in potential. The electrode can be used in the pH range from 1.0 to 3.5. The proposed sensor shows fairly good discriminating ability towards Hg2+ ion in comparison with some hard and soft metals. The electrode was used in the direct determination of Hg2+ in aqueous solution and as an indicator electrode in potentiometric titration of mercury ions.  相似文献   

9.
《Electroanalysis》2005,17(8):648-654
5‐[((4‐Methyl phenyl) azo)‐N‐(6‐amino‐2‐pyridin) salicylaldimine] (S1), and 5‐[((4‐methyl phenyl) azo)‐N‐(2‐diamino‐2‐cyano‐1‐ethyl cyanide) salicylaldehyde] (S2) with N and O donor atoms are effective ionophores to make Cd2+‐selective membrane electrodes. The electrodes based on S1 and S2 exhibits a Nernstian or near‐Nernstian response for cadmium ion over a wide concentration range 1.5×10?1–7.5×10?7 with a slope of 28 and 2.0×10?1–4.0×10?7 with a slope of 22, respectively. They have quick response and can be used for three or four months without any divergence in potential. The proposed sensors show fairly good selectivity over some alkali, alkaline earth, transition and heavy metal ions. The electrodes based on S1 and S2 can be used in the pH range 3.5–9. These electrodes were used as an indicator electrode in potentiometric titration of cadmium ion with EDTA and in the direct determination of cadmium ion in aqueous solutions.  相似文献   

10.
Potentiometric sensors for determining cobalt and nickel ions are described. They are based on the use of cobalt and nickel tris(1,10-phenanthroline)-TPB as electroactive compounds dispersed in plasticized poly(vinyl chloride) matrix. The sensors exhibit fast, near-Nernstian responses for cobalt and nickel-phenanthroline cations over the pH range 3–11 with a slope of 30.3 ± 0.3 mV/concentration decade. In the presence of excess 1,10-phenanthroline reagent, cobalt(II) and nickel(II) ions at concentration levels as low as 4 × 10–6 M are accurately determined. The results show an average metal ion recovery of 98.5% with a mean standard deviation of 0.5%. Cobalt in organometallic compounds and nickel in silicate rocks are determined by these sensors and results agreeing fairly well with atomic absorption spectrometry are obtained.  相似文献   

11.
A novel poly(vinyl chloride) membrane electrode with high selectivity toward salicylate (Sal), based on the use of the salicylal-imino acid Schiff base dibenyl complex of Sn(IV) [Sn(IV)-SIADBen] as ionophore is described. The influence of lipophilic charged additives on the performance of the electrode was studied. The results suggested that Sn(IV)-SIADBen according to a positively-charged carrier mechanism. The influence of several other variables was investigated in order to optimize the potentiometric response and selectivity of the electrode. The electrode based on Sn(IV)-SIADBen, with 30.44 wt% PVC, 64.55 wt% plasticizer [dioctyl phthalate (DOP)], 3.81 wt% ionophore, and 1.2 wt% anionic additive exhibited a linear response for the Sal ion over the concentration range 1.0×10–1 to 2.5×10–6 mol l–1, and displayed an anti-Hofmeister selectivity sequence as follows: salicylate perchlorate > thiocyanate > benzoate > iodide > nitrate > chloride > nitrite acetate > citrate > sulfate. UV-Visible absorption spectra were used to examine the specific interaction of salicylate with the ionophore. The electrode was applied to clinical medical analysis, and the results obtained were consistent with those obtained by conventional methods.  相似文献   

12.
The construction and performance characteristics of polymeric membrane electrodes based on two neutral ionophores, N,N′-[bis(pyridin-2-yl)formylidene]butane-1,4-diamine (S1) and N-(2-pyridinylmethylene)-1,2-benzenediamine (S2) for quantification of cadmium ions, are described. The influences of membrane compositions on the potentiometric response of the electrodes have been found to substantially improve the performance characteristics. The best performance was obtained with the electrode having a membrane composition (w/w) of (S1) (2.15%):PVC (32.2%):o-NPOE (64.5%):KTpClPB (1.07%). The proposed electrode exhibits Nernstian response in the concentration range of 7.9 × 10−8 to 1.0 × 10−1 M Cd2+ with limit of detection 5.0 × 10−8 M, performs satisfactorily over wide pH range (2.0-8.0) with a fast response time (10 s). The sensor has been found to work satisfactorily in partially non-aqueous media up to 30% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 2 months. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of cadmium in real samples. The practical utility of the membrane electrode has also been observed in the presence of surfactants.  相似文献   

13.
The reaction of trialkylgallium or indium R3M (M=In, Ga; R=Me, Et) with N,N′-ethylenebis(salicylideneimine) or 1,2-N,N′-phenylenebis(salicylideneimine) yields seven intramolecularly coordinated organogallium or organoindium complexes. Two hydroxyl protons in the ligands react with both trialkylindium and trimethylgallium, while one hydroxyl group reacts exclusively with triethylgallium. The complexes obtained have been fully characterised by elemental analysis, 1H-NMR, IR and mass spectroscopy. The structure of methyl-N,N′-bis(salicylidene)-1,2-phenylenediaminoindium (1) has been determined by single-crystal X-ray analysis. The In atom is five coordinate in the structure. Fluorescence spectroscopy has shown that the maximum emission wavelength of 1 is 499 nm upon radiation by UV light.  相似文献   

14.
Plasticised membranes using 2-[{(2-hydroxyphenyl)imino}methyl]-phenol (L1) and 2-[{(3-hydroxyphenyl)imino}methyl]-phenol (L2), have been prepared and investigated as Cu2+ ion-selective sensors. Effect of various plasticisers, namely, dibutyl phthalate (DBP), dibutyl sebacate (DBS), benzyl acetate (BA), o-nitrophenyloctylether (o-NPOE) and anion excluders, oleic acid (OA) and sodium tetraphenylborate (NaTPB) was studied and improved performance was observed in several instances. Optimum performance was observed with membranes of (L1) having composition L1 : DBS : OA : PVC in the ratio of 6 : 54 : 10 : 30 (w/w, %). The sensor works satisfactorily in the concentration range 3.2 × 10?8–1.0 × 10?1 mol L?1 with a Nernstian slope of 29.5 ± 0.5 mV decade?1 of a cu2+ . The detection limit of the proposed sensor is 2.0 × 10?8 mol L?1 (1.27 ng mL?1). Wide pH range (3.0–8.5), fast response time (7 s), sufficient (up to 25% v/v) non-aqueous tolerance and adequate shelf life (3 months) indicate the utility of the proposed sensor. The potentiometric selectivity coefficients as determined by matched potential method indicate selective response for Cu2+ ions over various interfering ions, and therefore could be successfully used for the determination of copper in edible oils, tomato plant material and river water.  相似文献   

15.
This study involves the preparation and investigation of a novel and highly selective poly(vinyl chloride)-based membrane of 2-((5-(2-hydroxy-3-methoxybenzylideneamino)-2H-1,2,4-triazol-3-ylimino)methyl)-6-methoxyphenol Schiff base ligand (HMBT), which is a neutral ionophore with sodium tetraphenyl borate (STB) in the form of an excluder and o-nitrophenyloctyl ether (o-NPOE) in the form of solvent mediators (plasticizing) as a Ni(II)-selective electrode. The observation of optimal performance was done wherein the membrane was shown to have the HMBT–PVC–NPOE-STB composition of 4:32:63:1.It worked effectively across a broad range of concentration (1.0 × 10?8 to 1.0 × 10?2 mol L?1). Meanwhile, the Nernstian slope was recorded as 29.3 mV per decade of activity between pH 3.0 and 8.0. The response time of this electrode was fast at 11 s which was used for a span of 100 days with sound reproducibility. According to the selectivity coefficients for trivalent, divalent, and monovalent cations, excellent selectivity was indicated for Ni(II) ions across a large number of citations, whereas no interference was caused by anions like PO43?, SO42? and Cl?. The proposed method in this study was applied successfully to determine Ni(II) content in different samples of water, obtaining suitable recoveries. Additionally, the probed sensor is utilized as indicator electrode when considering Ni2+ ion potentiometric titration against EDTA. In addition, the chelate’s geometry and structure of the complex formed between Ni2+ ions and HMBT, abbreviated as HMBT-Ni2, was evaluated by separating the solid product. Complex structure was confirmed based on alternative analytical and spectral methods to be structured in the bimetallic form with the formula [Ni2(HMBT)(H2O)2 Cl2]. The diamagnetic nature of the complex, which was concluded from the room temperature magnetic moment measurement combined with the UV–Vis measurement, suggested the square planar geometry around the Ni centers.  相似文献   

16.
A highly selective polyvinylchloride (PVC) membrane electrode based on Schiff base complex i.e. [Cobalt (Salpen) (PBu3)] ClO4 · H2O (Salpen = bis(salycilaldehyde)propylene diamine) is reported as new carrier for thiocyanate selective electrode by incorporating the membrane ingredients on the surface of graphite electrodes. The proposed electrode possesses a very wide Nernestian linear range to thiocyanate from 1.0 × 10?6 to 1.0 × 10?1 M with slope of ?59.05 ± 0.91 mV per decade of thiocyanate concentration, very low detection limit (8.0 × 10?7 M) and good thiocyanate selectivity over the wide variety of other anions. Fast and stable response, good reproducibility, long-term stability, applicability over a wide pH range (2.8–9.8) are advantages of the reported electrode. The sensor has a response time of <5 s and can be used for at least 14 weeks without any considerable change in respective potential response. The proposed electrode was used for the determination of thiocyanate in saliva, wastewater and human urine with satisfactory results and good agreement with colorimetric as reference method.  相似文献   

17.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on butane -2,3-dione bis(salicylhydrazonato) zinc(II) [Zn (BDSH)] complex as carrier for thiocyanate-selective electrode is reported. The influence of membrane composition, pH and possible interfering anions were investigated on the response properties of the electrode. The sensor responds to thiocyanate in linear range from 1.0 × 10−6 to 1.0 × 10−1 M with a slope −56.5 ± 1.1 mV decade−1, over a wide pH range of 3.5-8.5. The limit of detection of the electrode was 7.0 × 10−7 M SCN. Selectivity coefficients determined with fixed interference method (FIM) indicate a good discriminating ability towards SCN ion in comparison to other anions. The proposed sensor has a fast response time of about 5-15 s and can be used for at least 3 months without any considerable divergence in potential. It was applied as indicator electrode in titration of thiocyanate with Ag+ and in potentiometric determination of thiocyanate in saliva and urine samples.  相似文献   

18.
Three different mixed aza-thioether crowns containing a 1,10-phenanthroline sub-unit were investigated to characterize their abilities as copper(II) ion carriers in PVC-membrane electrodes. The electrode based on L1 exhibited a Nernstian response for Cu2+ ions over a wide concentration range (2×10−1 to 1×10−5 M) with a limit of detection of 8.0×10−6 M (0.5 p.p.m.). The response time of sensor is 15 s, and the membrane can be used for more than 3 months without observing any deviation. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, transition and heavy metal ions, and could be used in a pH range of 2.5–5.5. It was applied to the direct determination and potentiometric titration of the copper(II) ion.  相似文献   

19.
A new poly(vinyl chloride) (PVC) membrane ion‐selective electrode based on bis‐salicyladehyde‐diaminjodipropylamine (BSDDA) as an ion carrier was successfully applied to the detection of Hg2+ ions. This electrode displayed good selectivity toward Hg2+ in comparison with other metal ions and exhibited a Nernstian slope of 30.5 ± 0.4 mV per decade of Hg2+ over a concentration range of 9.5 × 10?7 to 6.4 × 10?2 M of Hg2+ in the pH range 1.5 to 3.5. The detection limit was 7.0 ± 0.2 × 10?7 M and response time was about 10 s to 25 s. The electrode can be used at least 2 months without apparent divergence in potential. In addition, the effects of experimental parameters such as membrane composition, nature and amounts of plasticizer and additive were investigated. The proposed electrode could be used as an indicator electrode in the detection of Hg2+ in samples.  相似文献   

20.
Several Schiff bases coordinated to vanadyl, VO(Schiff base), were synthesized, characterized and studied by thermogravimetry in order to evaluate their thermal stability and thermal decomposition pathways. The number of steps and, in particular, the starting temperature of decomposition of these complexes depend on the equatorial ligand. The intermediates of the thermal decomposition processes were characterized by their IR spectra.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号