1.
A microwave digestion method suitable for determination of multiple elements in marine species was developed, with the use of cold vapor atomic spectrometry for the detection of Hg, and inductively coupled plasma mass spectrometry for all of the other elements. An optimized reagent mixture composed of 2 ml of HNO3, 2 ml of H2O2 and 0.3 ml of HF used in microwave digestion of about 0.15 g (dry weight) of sample was found to give the best overall recoveries of metals in two standard reference materials. In the oyster tissue standard reference material (SRM 1566b), recoveries of Na, Al, K, V, Co, Zn, Se, Sr, Ag, Cd, Ni, and Pb were between 90% and 110%; Mg, Mn, Fe, Cu, As, and Ba recoveries were between 85% and 90%; Hg recovery was 81%; and Ca recovery was 64%. In a dogfish certified reference material (DORM-2), the recoveries of Al, Cr, Mn, Se, and Hg were between 90% and 110%; Ni, Cu, Zn, and As recoveries were about 85%; and Fe recovery was 112%. Method detection limits of the elements were established. Metal concentrations in flounder, scup, and blue crab samples collected from coastal locations around Long Island and in the Hudson River estuary were determined.  相似文献   

2.
Determination of Se(IV) and Se(VI) in high saline media was investigated by cathodic stripping voltammetry (CSV). The voltammetric method was applied to assay selenium in seawater, hydrothermal and hemodialysis fluids. The influence of ionic strength on selenium determination is discussed. The CSV method was based on the co-electrodeposition of Se(IV) with Cu(II) ions and Se(VI) determined by difference after sample UV-irradiation for photolytic selenium reduction. UV-irradiation was also used as sample pre-treatment for organic matter decomposition. Detection limit of 0.030 μg L−1 (240 s deposition time) and relative standard deviation (RSD) of 6.19% (n = 5) for 5.0 μg L−1 of Se(IV) were calculated. Linear calibration range for selenium was observed from 1.0 to 100.0 μg L−1. Concerning the pre-treatment step, best results were obtained by using 60 min UV-irradiation interval in H2O2/HCl medium. Se(VI) was reduced to the Se(IV) electroactive species with recoveries between 91.7% and 112.9%. Interferents were also investigated.  相似文献   

3.
A micro-scale flow system is proposed for on-line preconcentration of Cd, Cu, Mn, Ni and Pb in saliva samples and their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). A small column containing 8 μl of AG50W-X8 resin was inserted into the flow system, assembled with capillary tubes and connected to a micro-concentric nebulizer. The elution of the analytes was performed with 3 mol l−1 HCl at a flow rate of 82 μl min−1. The ICP-OES signal acquisition program permits measurements for 5 s in the concentrated portion of the transient elution peaks. A sample volume of 1 ml was required to obtain enrichment factors of 46, 23, 17, 18 and 44 for Cd, Cu, Mn, Ni and Pb, respectively. The relative standard deviations for a 50-μg l−1 multi-analyte solution were ≤6.5%. The recoveries for Cd, Cu, Mn, Ni and Pb in digested human saliva samples were between 86 and 111%. The sample throughput was 24 h−1.  相似文献   

4.
A flow analysis method with on-line sample digestion/minicolumn preconcentration/flame atomic absorption spectrometry is described for the determination of trace metals in urine. First, urine sample was on-line ultrasound-assisted digested exploiting the stopped-flow mode, and then the metals were preconcentrated passing the pre-treated sample through a minicolumn containing a chelating resin. A home-made minicolumn of commercially available imminodiacetic functional group resin, Chelite Che was used to preconcentrate trace metals (Cu, Fe, Mn and Ni) from urine. The proposed procedure allowed the determination of the metals with detection limits of 0.5, 1.1, 0.8 and 0.8 μg L−1, for Cu, Fe, Mn and Ni, respectively. The precision based on replicate analysis was less than ±10.0%, and the enrichment factor obtained was between 21.3 (Mn) and 44.1 (Ni), for sample volumes between 2.5 and 5.0 mL, and an eluent volume of 110 μL. This procedure was applied for determination of metals in urine of workers exposed to welding fumes and urine of unexposed persons (urine control).  相似文献   

5.
Closed-vessel microwave digestion of nine standard reference plant materials (NIST, BCR, IAEA) and a laboratory standard of plant material with different Si contents assisted by HNO3 + H2O2 (procedure A), HNO3 + H2O2 + HF + H3BO3 (procedure B) and HNO3 + H2O2 + HBF4 (procedure C) were used to determine the recovery of 36 elements by ICP-MS: Ag, Al, As, Ba, Be, Bi, Cd, Ce, Co, Cr, Cs, Cu, Fe, Ga, Ge, In, La, Li, Mn, Mo, Nd, Ni, Pb, Pr, Rb, Sb, Se, Sn, Sr, Th, Tl, U, V, W, Y, Zn. Additions of HF + H3BO3 and HBF4 in procedures B and C exceeded by 10% (B1, C1) and 100% (B2, C2) the equivalent concentrations of Si in the samples determined by ICP-OES. Most recoveries of certified elements (e.g., Al*, Cu, Mo*, Rb*, Sb*, Th) decreased significantly (*p ≤ 0.05) with increasing Si content in plant reference materials digested by procedure A, while the recoveries from procedures B and C decreased insignificantly only for Mo and Sb. Digestions B and C gave significantly higher recoveries of Al, Sb, W and REEs, which were tighter to the reference values of these elements. A similar effect was found for Cu, Fe, Li, Ni, Sn, Th, Tl, V, Zn, Ba, Rb and Sr recoveries in samples with Si contents exceeding 2000 μg g−1. If the Si content in plant samples is less than 10 mg g−1, digestion of 0.5 g of plant samples through 0.05 mL of HF and 0.5 mL of 4% H3BO3 or 0.1 mL of HBF4 is recommended to get satisfactory results for most of the elements. For materials with Si content exceeding 10 mg g−1 the weight of the sample for digestion should be reduced to 0.25 g. However, the operation of potential interferences should be taken into account and eliminated through correction equations and adequate dilution of the samples.  相似文献   

6.
A simple flow injection on-line dilution procedure with detection by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of copper, zinc, arsenic, lead, selenium, nickel and molybdenum in human urine. Matrix effects were minimized by employing a dilution factor of 16.5 with on-line standard addition, and (103)Rh was used as internal standard to compensate for signal fluctuation. The procedure was validated by the analysis of two standard reference materials SRM 2670 (NIST) and Seronormtrade mark Trace Elements in Urine. Recovery experiments were performed by spiking the reference materials as well as artificial urine. The detection limits (mug l(-1)) were 0.12,0.96,0.30,0.09,0.45,0.08,0.09, and the precisions (RSD,%) were 2.6,2.3,3.0,3.7,3.7,4.9,2.8 for Cu, Zn, As, Pb, Se, Ni and Mo, respectively. The procedure was applied to the analysis of 41 human urine samples. No correlations between the concentrations of the elements were observed.  相似文献   

7.
Atanassova D  Stefanova V  Russeva E 《Talanta》1998,47(5):2655-1243
Sodium diethyldithiocarbamate in the presence of a weak oxidizing agent is used as a co-precipitative agent for the pre-concentration of Se, Cu, Pb, Zn, Fe, Co, Ni, Mn, Cr and Cd. A procedure was developed for ICP-AES determination of these elements after pre-concentration in river and waste water (an enrichment factor of 40). The recovery of all the elements tested for was more than 98%. The limits of determination (mg l−1) (10 S.D. blank) are 0.001 (Cu, Co, Cr, Mn), 0.0007 (Zn, Cd), 0.003 (Se), 0.004 (Fe), 0.007 (Ni), and 0.01 (Pb).  相似文献   

8.
Summary The element contents of Cd, Cu, Hg, Ni, Pb and Zn of three types of soil were certified. The preparation, homogeneity and stability are reported. The certified contents as well as values for Co, Cr, Mn and Se and for the aqua regia soluble contents Cd, Cr, Cu, Mn, Ni, Pb and Zn are given.
Zertifizierung von Schwermetallspuren (Cd, Cu, Hg, Ni, Pb und Zn) in drei Bodenproben
Zusammenfassung In drei verschiedenen Bodenproben wurden die Elementgehalte an Cd, Cu, Hg, Ni, Pb und Zn zertifiziert. Es wird berichtet über die Bereitung, Homogenität und Stabilität. Die zertifizierten Gehalte sowie der Gehalt an Cr, Co, Mn und Se und der Gehalt an königswasserlöslichem Cd, Cr, Cu, Mn, Ni, Pb und Zn werden angegeben.
  相似文献   

9.
Summary The element contents of Cd, Co, Cu, Mn, Hg, Ni, Pb and Zn of three different types of sewage sludge were certified. The preparation, the homogeneity and the stability are reported. The certified contents as well as values for Cr and Se and for the aqua regia soluble contents of Cd, Cr, Co, Cu, Mn, Ni, Pb and Zn are given.
Zertifizierung von Schwermetallspuren (Cd, Co, Cu, Mn, Hg, Ni, Pb und Zn) in drei Klärschlammproben
Zusammenfassung In drei verschiedenen Klärschlammproben wurden die Elementgehalte an Cd, Co, Cu, Mn, Hg, Ni, Pb und Zn zertifiziert. Es wird berichtet über die Herstellung, Homogenität und Stabilität. Die zertifizierten Gehalte sowie der Gehalt von Cr, Se und der Gehalt an königswasserlöslichem Cd, Cr, Co, Cu, Mn, Ni, Pb und Zn werden angegeben.
  相似文献   

10.
A method for simultaneously determining the trace elements in particulate matter (PM) (PM2.5) by inductively coupled plasma mass spectrometry was established. The PM2.5-loaded filter samples were digested under the optimised conditions including a mixture of HNO3–HCl–HF with ultrasonication proceeding at 70°C for 2 h. Recoveries of 90.83–103.33% were achieved for 20 elements (Co, Sr, Ag, Cd, Sb, La, Ce, Sm, W etc.) in NIST standard reference material 1648a (urban PM). PM2.5 samples were collected at urban site in Hangzhou from August 2015 to November 2015. PM2.5 concentrations of 15% sampling days exceeded the daily limitation and the mean concentrations of PM2.5 from August to November reached the 66.4% of the limitation. PM2.5 concentrations in summer were higher than that in autumn. The concentration of Zn was highest, following with Al, Pb, Mn, Cu and As. Significant enrichment was observed in Mn, Zn, Pb, Ag, V, Ni, Cu, As, Se, Hg, Co, Cd and W, which was probably induced by vehicular exhaust, oil and residual fuel combustion and industrial emissions. The daily mass concentrations of PM2.5 and elements fluctuated significantly. Rainfall could significantly reduce the concentration of Ti, Mn, Cu, Zn, As, Se, Hg, Sr, Ag, Cd, Sb, La, Ce, Sm and Pb, and the risk levels of carcinogenic elements and non-carcinogenic elements in rain day were significantly lower (43.7–81.4%) than those in non-rain day. The risk levels of Co, Cd and As could lead to adverse health outcomes through the respiratory system, which should deserve more attention, while the risk levels of Ni and non-carcinogenic elements (Hg, Mn, Cu, Zn, Pb, V) were under average risk acceptance.  相似文献   

11.
Hsiang MC  Sung YH  Huang SD 《Talanta》2004,62(4):791-799
A simple method was developed for the direct and simultaneous determination of arsenic (As), manganese (Mn), cobalt (Co), and nickel (Ni) in urine by a multi-element graphite furnace atomic absorption spectrometer (Perkin-Elmer SIMAA 6000) equipped with the transversely heated graphite atomizer and longitudinal Zeeman-effect background correction. Pd was used as the chemical modifier along with either the internal furnace gas or a internal furnace gas containing hydrogen and a double stage pyrolysis process. A standard reference material (SRM) of Seronorm™ Trace Elements in urine was used to confirm the accuracy of the method. The optimum conditions for the analysis of urine samples are pyrolysis at 1350 °C (using 5% H2 v/v in Ar as the inter furnace gas during the first pyrolysis stage and pure Ar during the second pyrolysis stage) and atomization at 2100 °C. The use of Ar and matrix-free standards resulted in concentrations for all the analytes within 85% (As) to 110% (Ni) of the certified values. The recovery for As was improved when mixture of 5% H2 and 95% Ar (v/v) internal furnace gas was applied during the first step of a two-stage pyrolysis at 1350 °C, and the found values of the analytes were within 91-110% of the certified value. The recoveries for real urine samples were in the range 88-95% for these four elements. The detection limits were 0.78 μg l−1 for As, 0.054 μg l−1 for Mn, 0.22 μg l−1 for Co, and 0.35 μg l−1 for Ni. The upper limits of the linear calibration curve are 60 μg l−1 (As); 12 μg l−1 (Mn); 12 μg l−1 (Co) and 25 μg l−1 (Ni), respectively. The relative standard deviations (R.S.D.s) for the analysis of SRM were 2% or less. The R.S.D.s of a real urine sample are 1.6% (As), 6.3% (Mn), 7.0% (Ni) and 8.0% (Co), respectively.  相似文献   

12.
An effective, rapid and simple analytical method for the determination of Na, K, Ca, Mg, Cd, Pb, Ba, Fe, Mn, Sr, Zr, Cu, Zn and Al at mg kg−1 levels in the ultrapure salts MgCl2 and CaCl2 using optical emission spectrometry was developed. Optimisation of the operation conditions was performed with real samples of ultrapure MgCl2 and CaCl2. The results of the determination with multi-elemental water standards were compared to the internal standardisation, the standard addition method, and the maximum allowable content of the above mentioned elements in pure chemicals. The method was shown to be very sensitive with the following limits of detection: Na 1.01, K 3.12, Ca 0.263, Mg 0.275, Cd 0.0832, Pb 0.482, Ba 0.0153, Fe 0.0528, Mn 0.0473, Sr 0.0203, Zr 0.638, Cu 0.0732, Zn 0.0686 and Al 0.459 (all in mg kg−1). The method exhibited satisfactory precision, high analytical recoveries, linear responses of an accuracy of at least 4 orders of magnitude and low contamination susceptibility.  相似文献   

13.
A method for the direct determination (without sample pre-digestion) of microelements in fruit juice by inductively coupled plasma optical emission spectrometry has been developed. The method has been optimized by a 23 factorial design, which evaluated the plasma conditions (nebulization gas flow rate, applied power, and sample flow rate). A 1:1 diluted juice sample with 2% HNO3 (Tetra Packed, peach flavor) and spiked with 0.5 mg L− 1 of Al, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Sb, Sn, and Zn was employed in the optimization. The results of the factorial design were evaluated by exploratory analysis (Hierarchical Cluster Analysis, HCA, and Principal Component Analysis, PCA) to determine the optimum analytical conditions for all elements. Central point condition differentiation (0.75 L min− 1, 1.3 kW, and 1.25 mL min− 1) was observed for both methods, Principal Component Analysis and Hierarchical Cluster Analysis, with higher analytical signal values, suggesting that these are the optimal analytical conditions. F and t-student tests were used to compare the slopes of the calibration curves for aqueous and matrix-matched standards. No significant differences were observed at 95% confidence level. The correlation coefficient was higher than 0.99 for all the elements evaluated. The limits of quantification were: Al 253, Cu 3.6, Fe 84, Mn 0.4, Zn 71, Ni 67, Cd 69, Pb 129, Sn 206, Cr 79, Co 24, and Ba 2.1 µg L− 1. The spiking experiments with fruit juice samples resulted in recoveries between 80 and 120%, except for Co and Sn. Al, Cd, Pb, Sn and Cr could not be quantified in any of the samples investigated. The method was applied to the determination of several elements in fruit juice samples commercialized in Brazil.  相似文献   

14.
A microwave digestion method in a closed vessel was developed for the determination of trace metals in atmospheric aerosols using inductively coupled plasma mass spectrometry (ICP-MS). A recovery study for the elements V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Cd, Sb, and Pb was conducted using multi-elemental standard solutions, NIST 1633b Trace Elements in Coal Fly Ash, and NIST 1648 Urban Particulate Matter. A simple digestion method using only HNO3/H2O2 gave good recoveries (90%–108%) for all elements except Cr in SRM 1648, but yielded low recoveries for SRM 1633b. A more robust method using HNO3/H2O2/HF/H3BO3 yielded higher recoveries (82%–¶103%) for the lighter elements (V – Zn) in SRM 1633b, and improved the Cr recovery in SRM 1648, but decreased the Se recovery in both SRMs. A comparative analysis of aerosol samples obtained at a remote mountain location Nathiagali, Pakistan (2.5 km above mean sea level), and Mayville, New York, downwind from the highly industrialized Midwestern United States, was carried out using Instrumental Neutron Activation Analysis (INAA) for the elements Cr, Mn, Fe, Co, Zn, As, Se, and Sb. The simple digestion method yielded excellent agreement for Cr, Fe, Zn, As, Se, and Sb, with slopes of the ICP-MS vs. INAA regressions of 0.90–1.00 and R2 values of 0.96–1.00. The regressions for Mn and Co had slopes of 0.82 and 0.84 with R2 values of 0.83 and 0.82, respectively. Addition of HF/H3BO3 did not improve the correlation for any of the elements and degraded the precision somewhat. The technique provides sensitivity and accuracy for trace elements in relatively small aerosol samples used in atmospheric chemistry studies related to SO2 oxidation in cloud droplets. The ability to determine concentrations of a very large number of elements from a single analysis will permit source apportionment of various trace pollutants and hence strategies to control the sources of air pollution. This is particularly important as the health effects of particulate matter are increasingly recognized.  相似文献   

15.
《Analytical letters》2012,45(3):509-534
Abstract

The sequential determination of 14 trace metals, Al, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Mo, Cd, Sb and Pb, in rain and river water samples has been investigated using an inductively coupled plasma mass spectrometry (ICP-MS) with a graphite rod electrothermal vaporizer (ETV) in the presence of the mixed modifier of palladium nitrate and magnesium nitrate. The sensitivity enhancements due to the presence of the modifier were observed for all analyte elements. Detection limits as high as 0.52, 0.13, 0.89, 0.35, 1.76, 0.5, 0.9, 0.5, 0.04, 1.03, 0.28, 0.07, 0.1 and 3.78 pg, respectively, for Al, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Mo, Cd, Sb and Pb have been achieved. For the determination of trace metals in both rain and river water samples by this method, the repeatibility of sample solution were very good, i.e. from 1% to 7% (as a coefficient variation) and the recoveries of elements were good enough, i.e. from 81% to 106%, by using a standard addition method. There was no difference between the results obtained by nebulizer ICP-MS and those obtained by this method, except for zinc and arsenic.  相似文献   

16.
Based on carbon nanofibers (CNFs) as a solid phase extraction adsorbent, a microcolumn preconcentration method coupled to inductively coupled plasma mass spectrometry (ICP–MS) was developed for the determination of trace elements (Mn, Co and Ni). The effect of various experimental parameters such as pH, sample flow rate and volume, elution solution and interfering ions on the retention of the studied ions have been investigated systematically. During all the steps of the experimental process, Mn, Co and Ni could be quantitatively sorbed on the microcolumn containing CNFs in the range of pH 6.0–9.0, and then eluted completely with 0.5 mol ml− 1 HNO3. A preconcentration factor of 150-fold was obtained. The detection limits for Mn, Co and Ni were 40, 0.4 and 8.0 pg ml− 1, respectively, with relative standard deviations less than 6.0%. In order to validate the proposed method, two certified reference materials of human hair (GBW 07601) and mussel (GBW 08571), and water sample were analyzed with satisfactory results. The recoveries were between 95.0 and 114%.  相似文献   

17.
Tyrrellite, a naturally occurring Co–Ni–Cu selenide, has been studied by single‐crystal X‐ray diffraction. It possesses the normal spinel‐type structure, with Cu occupying the tetrahedral site and (Co+Ni) the octahedral site. The average Cu—Se distance of 2.3688 (2) Å is close to that of 2.3703 (8) Å in CuCr2Se4, whereas the average (Co+Ni)—Se distance of 2.3840 (1) Å appears to be slightly shorter than most octahedral Co—Se or Ni—Se distances (∼2.40–2.50 Å) in other selenides. The refined structure provides a basis for a redefinition of the ideal chemical formula of tyrrellite, which should be Cu(Co,Ni)2Se4, rather than the previously suggested (Cu,Co,Ni)3Se4.  相似文献   

18.
牡蛎、缢蛏和菲律宾蛤仔中微量元素的分析研究   总被引:1,自引:1,他引:0  
采用硝酸-高氯酸法消解样品,应用ICP—AES法测定了牡蛎、缢蛏和菲律宾蛤仔中Ca、Co、Cr、Cu、Fe、Mg、Mn、Ni、Se、Sr、V和Zn共12种微量元素。实验结果表明,3种贝类中均含有大量的Ca、Cu、Fe、Mn、Zn、Mg,还含有Co、Cr、Ni、Se、Sr和V等对人体有益的微量元素,是营养价值较高的海产品,可以作为人体补充微量元素的重要来源。  相似文献   

19.
The use of inductively coupled plasma mass spectrometry (ICP-MS) for the determination of trace elements in Al2O3 powders is reported. Special interest is given to a preconcentration of the trace elements by on-line coupling of chromatography to ICP-MS. This is based on the complexation of Co, Cu, Cr, Fe, Ga, Mn, Ni, V and Zn with hexamethylene-dithiocarbamate (HMDC), their preconcentration on a C18 RP column by reversed phase liquid chromatography and their elution with CH3OH-H2O mixtures. A direct coupling of the HPLC system to the ICP-MS has been realized by high pressure pneumatic nebulization using desolvation. With the Chromatographie method developed, removal of the AI by at least 99% was achieved. For the trace elements V, Fe, Ni, Co, Cu and Ga, high and reproducible recoveries (ranging from 96–99%) were reached. The method developed has been shown to considerably enhance the power of detection as compared with direct procedures, namely down to 0.02–0.16 ( for V and Fe, respectively. The possibilities of the method are shown by the determinations of V, Mn, Fe, Ni, Co, Cu, Zn and Ga at the μg/g level in A12O3 powders. The accuracy of the method at the 0.06 to 9.0 level for Co and Fe, respectively, is demonstrated by a comparison with results of independent methods from the literature.  相似文献   

20.
Grigoletto T  Oliveira Ed  Gutz IG 《Talanta》2005,67(4):791-797
The new electrolytic dissolution in batch of aluminum alloys samples as grains or turns and the determination of Fe, Cu, Mn, Mg, Cr, Ni, Zn, Pb and Ti by ICP OES was investigated. In on-line electrodissolution procedures described in the literature, samples were restricted to be in the form of solid blocks or plates with one polished flat face. Here, the sample was loaded in the barrel of a modified disposable syringe (the anodic semi-cell) and pressed with a modified plunger fitted with a platinum disk to establish electrical contact with the analyte. This arrangement was introduced in a beaker containing the electrolyte (1 mol L−1 HNO3) and a platinum wire as the cathode. The resulting solution from electrodissolution (0.6 A) was used for the ICP OES determinations. The influence of the aluminum concentration increase on the determination of the elements was evaluated. Electrodissolution of certified reference materials and commercial samples revealed relative errors lower than 10% for the elements Fe, Cu, Mg, Ni, Cr, Zn and Ti (when their content is above 0.1%). Higher inaccuracies (>10%) were observed for Mn and for Fe in B.C.S. 268/1 reference material certified. The proposed method presented a relative standard deviations (R.S.D.) lower or circa 10% to all of the elements (except Pb). In comparison with traditional acid dissolution, the proposed electrodissolution method is relatively fast (about 30 min), it is clean (there is no projection of solution) and simple (heating and fumes exhaust system were not necessaries).  相似文献   