首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Sun Z  You J  Song C  Xia L 《Talanta》2011,85(2):1088-1099
A new labeling reagent for carboxylic acids, 2-(2-(anthracen-10-yl)-1H-phenanthro[9,10-d]imidazol-1-yl)ethyl 4-methylbenzenesulfonate (APIETS) has been designed and synthesized. It was used to label eight fatty acids (lauric acid, myristic acid, palmitic acid, stearic acid, arachidic acid, oleic acid, linoleic acid and linolenic acid) and four hydroxy pentacyclic triterpene acids (oleanolic acid, ursolic acid, betulinic acid and maslinic acid), successfully. APIETS could easily and quickly label carboxylic acids in the presence of K2CO3 catalyst at 85 °C for 35 min in N,N-dimethylformamide solvent. The carboxylic acids derivatives were separated on a C8 reversed-phase column with gradient elution and fluorescence detection at λex/λem = 315/435 nm. Identification of these derivatives was carried out by online mass spectrometry with atmospheric pressure chemical ionization in positive ion mode. The detection limits obtained were 13.37-30.26 fmol (signal-to-noise ratio of 3). The proposed method has been applied to the quantification of carboxylic acids in sultana raisin (Thompson seedless), hawthorn flake (Crataegus pinnatifida Bge.), Lycium barbarum seed oil and Microula sikkimensis seed oil with recoveries over 95.3%. It has been demonstrated that APIETS is a prominent labeling reagent for determining carboxylic acids with high performance liquid chromatography.  相似文献   

2.
Alternative approaches to conventional acetonitrile gradient methods for reversed-phase liquid chromatographic analysis of intact proteins have been investigated using commercial poly(styrene-co-divinylbenzene) monolithic columns (Dionex ProSwift™ RP-2H and RP-4H). Alternative solvents to acetonitrile (2-propanol and methanol) coupled with elevated temperatures demonstrated complementary approaches to adjusting separation selectivity and reducing organic solvent consumption. Measurements of peak area at increasing isothermal temperature intervals indicated that only minor (<5%) decreases in detectable protein recovery occurred between 40 and 100 °C on the timescale of separation (2–5 min). The reduced viscosity of a 2-propanol/water eluent at elevated temperatures permitted coupling of three columns to increase peak production (peaks/min) by 16.5%. Finally, narrow-bore (1 mm i.d.) columns were found to provide a more suitable avenue to fast, high temperature (up to 140 °C) separations.  相似文献   

3.
Four different organic solvents: dimethylformamide, 1,4-dioxane, n-propanol and ethanol were evaluated as alternative organic modifiers to acetonitrile for liquid chromatography (LC) separations. The aim was to establish common sets of chromatographic conditions that could be applied for LC hyphenation to inductively coupled plasma mass spectrometry (ICPMS) as well as to electrospray ionization MS (ESIMS). The approach was to evaluate candidate solvents that, compared to acetonitrile, potentially could give improved analytical performance (low solvent vapor loading, maximized analyte sensitivity and minimized carbon depositions on instrumental parts) in ICPMS analysis while retaining chromatographic and ESIMS performances. The study showed that dimethylformamide, 1,4-dioxane, n-propanol and ethanol all can be advantageous chromatographic modifiers for LC–ICPMS analysis, giving superior performance compared to acetonitrile. For the combined use of LC–ICPMS and LC–ESIMS with a common set of chromatographic conditions, n-propanol gave the best overall performance. The 195Pt+ signal in ICPMS was continuously monitored during a 0–60% organic solvent gradient and at 25% of organic modifier, 100% of the signal obtained at the gradient start was preserved for n-propanol compared to only 35% of the signal when using acetonitrile. Platinum detection limits were 5–8 times lower using n-propanol compared with acetonitrile. Signal-to-noise ratio in continuous ESIMS signal measurements was 100, 90 and 110 for a 100 μg/ml solution of leucine–enkephaline using acetonitrile, ethanol and n-propanol, respectively. Chromatographic efficiency in reversed phase separations was preserved for n-propanol compared to acetonitrile for the analysis of the whole protein cytochrome C and the peptide bacitracin on a column with particle and pore sizes of 5 μm and 300 Å, but slightly deteriorated for the separation of the peptides leucine–enkephaline and bacitracin on a 3 μm and 90 Å column as the peak width at half height for both peptides increased by a factor of two. The performance on the smaller dimensioned column could however be improved by running the separations at 40 °C.  相似文献   

4.
A high-performance liquid chromatographic method has been developed for the determination in human plasma of the specific serotonin reuptake inhibitor (SSRI) antidepressant paroxetine and its three main metabolites (M1, M2, M3). Fluorescence detection was used, exciting at λ = 294 nm and monitoring emission at λ = 330 nm for paroxetine (λexc = 280 nm, λem = 330 nm for M1 and M2; λexc = 268 nm, λem = 290 nm for M3). Separation was obtained on a reversed-phase C18 column using a mobile phase composed of 66.7% aqueous phosphate at pH 2.5 and 33.3% acetonitrile. Imipramine (λexc = 252 nm, λem = 390 nm) was used as the internal standard. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with C8 cartridges (50 mg, 1 mL). The calibration curves were linear over a working range of 2.5-100 ng mL−1 for paroxetine and of 5-100 ng mL−1 for all metabolites. The limit of detection (LOD) was 1.2 ng mL−1 for PRX and 2.0 ng mL−1 for the metabolites. The method was applied with success to plasma samples from depressed patients undergoing treatment with paroxetine. Hence, the method seems to be suitable for the therapeutic drug monitoring of paroxetine and its main metabolites in depressed patients’ plasma.  相似文献   

5.
A simple and sensitive high performance liquid chromatography method with photodiode array detection (HPLC-DAD) was developed for simultaneous determination of eight bioactive constituents (schisandrin, schisandrol B, schisantherin A, schisanhenol, anwulignan, deoxyshisandrin, schisandrin B and schisandrin C) in the ripe fruit of Schisandra sphenanthera and its traditional Chinese herbal preparations Wuzhi-capsule by optimizing the extraction, separation and analytical conditions of HPLC-DAD. The chemical fingerprint of S. sphenanthera was established using raw materials of 15 different origins in China. The chromatographic separations were obtained by an Agilent Eclipse XDB-C18 reserved-phase column (250 mm × 4.6 mm i.d., 5 μm) using gradient elution with water-formic acid (100:0.1, v/v) and acetonitrile, at a flow rate of 1.0 mL min−1, an operating temperature of 35 °C, and a wavelength of 230 nm. The constituents were confirmed by (+) electrospray ionization LC-MS. The new method was validated and was successfully applied to simultaneous determination of components in 13 batches of Wuzhi-capsule. The results indicate that this multi-component determination method in combination with chromatographic fingerprint analysis is suitable for quantitative analysis and quality control of S. sphenanthera.  相似文献   

6.
In this study the development, validation and application of a new chromatographic method for the determination of glutathione (GSH) in wine samples is presented. The separation of the GSH was carried out using a sulfobetaine-based hydrophilic interaction chromatography (HILIC) analytical column whereas its detection was carried out spectrofluorimetrically (λext/λem = 340/455 nm) after post-column derivatization with o-phthalaldehyde. GSH was separated efficiently from matrix endogenous compounds of wines by using a mobile phase of 15 mmol L−1 CH3COONH4 (pH = 2.5)/CH3CN, 35/65% (v/v). The parameters of the post-column reaction (pH, amount concentration of the reagent and buffer solution, flow rate, length of the reaction coil) were investigated. The linear determination range for GSH was 0.25–5.0 μmol L−1 and the LOD was 19 nmol L−1. No matrix effect was observed, while the accuracy was evaluated with recovery experiments and was ranged between 89% and 108%.  相似文献   

7.
Calorimetric titration and NMR experiments in aqueous phosphate buffer (pH 7.2) at 298.15 K have been done to determine the binding mode, complex stability constants and thermodynamics (ΔG°, ΔH°, and TΔS°) for 1:1 inclusion complexation of water-soluble calix[n]arenesulfonates (CnAS, n = 4 and 6) and thiacalix[4]arene tetrasulfonate (TCAS) with acethylcholine, carnitine, betaine and benzyltrimethylammonium ion. The results show the inclusion complexations are driven by enthalpy (ΔH° < 0), accompanied by negative entropic changes (ΔS° < 0). The binding affinities (C4AS > C6AS > TCAS) are discussed from the viewpoint of CH-π/π-π interactions, electrostatic interactions and size/shape-fit relationship between host and guest.  相似文献   

8.
A rapid, sensitive and efficient liquid phase microextraction (LPME) method was developed to determine trace concentrations of some organophosphorus pesticides in water samples. This method combines liquid phase microextraction with gas chromatographic (GC) analysis in a simple and inexpensive apparatus involving very little organic solvent consumption. It involves exposing a floated drop of an organic solvent on the surface of aqueous solution in a sealed vial. Experimental parameters which control the performance of LPME such as type of organic solvent, organic solvent and sample volumes, sample stirring rate, sample solution temperature, salt addition and exposure time were investigated and optimized. Finally, the enrichment factor, dynamic linear range (DLR), limit of detection (LOD) and precision of the method were evaluated by the water samples spiked with organophosphorus pesticides. Using optimum extraction conditions, very low detection limits (0.01-0.04 μg L−1) and good linearities (0.9983 < r2 < 0.9999) were achieved. The LPME was performed for determination of organophosphorus pesticides in different types of natural water samples and acceptable recoveries (96-104%) and precisions (3.5 < R.S.D.% < 8.9) were obtained. The results suggested that the newly proposed LPME method is a rapid, accurate and effective sample preparation method and could be successfully applied for extraction and determination of organophosphorus pesticides in water samples.  相似文献   

9.
Li YS  Gao XF 《Analytica chimica acta》2007,588(1):140-146
A novel method for the determination of ethanol in tequila based on the immobilized enzyme fluorescence capillary analysis (IE-EFCA) has been proposed. Alcohol dehydrogenase (ADH) was immobilized in inner surface of a capillary and an immobilized enzyme capillary bioreactor (IE-ECBR) was formed. After nicotinamide adenine dinucleotide (NAD+) as an oxidizer is mixed with alcohol sample solution, it was sucked into the IE-ECBR. The fluorescence intensity of the mixed solution in the IE-ECBR was detected at λex = 350 nm and λem = 459 nm. The experimental conditions are as follows: The reaction time is 20 min; temperature is 40 °C; the concentrations of phosphate buffer solution (pH 7.5) and NAD+ are 0.1 mol L−1 and 5 mmol L−1, respectively; immobilization concentration of ADH is 10 U L−1. The determination range of ethanol is 2.0-15.0 g L−1 (F = 10.44C + 6.6002, r > 0.9958); its detection limit is 1.11 g L−1; and relative standard deviation is 1.9%. IE-EFCA method is applicable for the determination of the samples containing alcohol in medicine, industry and environment.  相似文献   

10.
A novel and sensitive cloud point extraction procedure using pH-sensitive hydrogel was developed for preconcentration and spectrophotometric determination of trace amounts of malachite green (MG). In this extraction method, appropriate amounts of poly(styrene-alt-maleic acid), as a pH-sensitive hydrogel, and HCl were added respectively into the aqueous sample so a cloudy solution was formed. The cloudy phase consists of hydrogel particles distributed entirely into the aqueous phase. Organic or inorganic compounds having the potential to interact with polymer particles (chemical interaction or physical adsorption) could be extracted to cloudy phase. After centrifuging, these particles of hydrogel were sedimented in the bottom of sample tube. The sedimented hydrogel-rich phase was diluted with acetonitrile and its absorbance was measured at 617 nm (λmax of malachite green in hydrogel). Central composite design and response surface method were applied to design the experiments and optimize the experimental parameters such as, concentration of hydrogel and HCl, extraction time and salting out effect. Under the optimum conditions, the linear range was 1 × 10−8-5 × 10−7 mol L−1 malachite green with a correlation coefficient of 0.992. The limit of detection (S/N = 3) was 4.1 × 10−9 mol L−1. Relative standard deviation (RSD) for 7 replicate determinations of 10−7 mol L−1 malachite green was 3.03%. In this work, the concentration factor of 20 was reached. Also the improvement factor of the proposed method was 23. The advantages of this method are simplicity of operation, rapidity and low cost.  相似文献   

11.
This work presents an high-performance liquid chromatography method for the determination of amino acids after precolumn derivatization with 4-chloro-3,5-dinitrobenzotrifluoride (CNBF) which can readily react with both primary and secondary amines. The precolumn derivatization conditions, including the CNBF concentration, reaction pH, temperature and reaction time were investigated for method optimization. In pH 9.0 borate buffer, the reaction of amino acids with CNBF was carried out at 60 °C for 30 min, the optimized concentration of CNBF was 70 mmol L−1 and the molar ratio of amino acids to CNBF was 1:5.25. The chromatographic separation of 19 amino acids derivatives was performed on a Kromasil ODS C18 column (250 mm × 4.6 mm, 5 μm) with good reproducibility, and ultraviolet detection was applied at 260 nm. The mobile phase was a mixture of phase A (acetonitrile) and phase B (acetate buffer, acetonitrile, triethylamine; 82.8:17:0.2, pH 4.9), and the flow rate was 0.4 mL min−1. The separation of all the labeled amino acids was achieved within 45 min at room temperature by gradient elution mode. The method linearity, calculated for each amino acid, had a correlation coefficient higher than 0.9979, in concentrations ranging from 9.60 to 3330.00 μmol L−1. The detection limits of amino acids were 2.40-6.50 μmol L−1, at a signal-to-noise ratio of 3. The proposed method was applied for the determination of amino acids in beer with recoveries of 97.0-103.9% and relative standard deviations of 2.62-4.22%, respectively. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples.  相似文献   

12.
A simple isocratic reversed-phase high-performance liquid chromatographic method (RP-HPLC) was developed for the simultaneous determination of buprenorphine hydrochloride, naloxone hydrochloride dihydrate and its major impurity, noroxymorphone, in pharmaceutical tablets. The chromatographic separation was achieved with 10 mmol L−1 potassium phosphate buffer adjusted to pH 6.0 with orthophosphoric acid and acetonitrile (17:83, v/v) as mobile phase, a C-18 column, Perfectsil Target ODS3 (150 mm × 4.6 mm i.d., 5 μm) kept at 35 °C and UV detection at 210 nm. The compounds were eluted isocratically at a flow rate of 1.0 mL min−1. The average retention times for naloxone, noroxymorphone and buprenorphine were 2.4, 3.8 and 8.1 min, respectively. The method was validated according to the ICH guidelines. The validation characteristics included accuracy, precision, linearity, range, specificity, limit of quantitation and robustness. The calibration curves were linear (r > 0.996) over the concentration range 0.22-220 μg mL−1 for buprenorphine hydrochloride and 0.1-100 μg mL−1 for naloxone hydrochloride dihydrate and noroxymorphone. The recoveries for all three compounds were above 96%. No spectral or chromatographic interferences from the tablet excipients were found. This method is rapid and simple, does not require any sample preparation and is suitable for routine quality control analyses.  相似文献   

13.
In this study, a porous polypropylene frit was coated with polydimethylsiloxane (PDMS) as extraction medium, based on the home-made PDMS-frit, a rapid, simple and sensitive sorptive extraction method was established for analysis of potential biomarkers of lung cancer (hexanal and heptanal) in human serum samples. In the method, derivatization and extraction occurred simultaneously on the PDMS-frit, then the loaded frit was ultrasonically desorbed in acetonitrile. Polymerization, derivatization–extraction and desorption conditions were optimized. Under the optimal conditions, satisfactory results were gained, a wide linear application range was obtained in the range of 0.002–5.0 μmol L−1 (R > 0.997) for two aldehydes, the detection limits (S N−1 = 3) were 0.5 nmol L−1 for hexanal and 0.4 nmol L−1 for heptanal. The relative standard deviations (RSDs, n = 5) of the method were below 7.9% and the recoveries were above 72.7% for the spiked serum. All these results hint that the proposed method is potential for disease markers analysis in complex biological samples.  相似文献   

14.
A novel method for the non-derivatization liquid chromatographic determination of metals (potassium, aluminium, calcium and magnesium) and organic compounds (ascorbate and aspartate) was developed and validated based on evaporative light scattering detection (ELSD). Separation of calcium, magnesium and aluminium was achieved by the cation exchange column Dionex CS-14 and an aqueous TFA mobile phase according to the following time program: 0-6 min TFA 0.96 mL L−1, 6-7 min linear gradient from TFA 0.96-6.4 mL L−1. Separation of potassium, magnesium and aspartate was achieved by the lipophilic C18 Waters Spherisorb column and isocratic aqueous 0.2 mL L−1 TFA mobile phase. Separation of sodium, magnesium, ascorbate and citrate was also achieved by the C18 analytical column, according to the following elution program: 0-2.5 min aqueous nonafluoropentanoic acid (NFPA) 0.5 mL L−1; 2.5-3.5 min linear gradient from 0.5 mL L−1 NFPA to 1.0 mL L−1 TFA. In all cases, evaporation temperature was 70 °C, pressure of the nebulizing gas (nitrogen) 3.5 bar, gain 11 and the flow rate 1.0 mL min−1. Resolution among calcium and magnesium was 1.8, while for all other separations was ≥3.2. Double logarithmic calibration curves were obtained within various ranges from 3-24 to 34-132 μg mL−1, and with good correlation (r > 0.996). Asymmetry factor ranged from 0.9 to 1.9 and limit of detection from 1.3 (magnesium) to 17 μg mL−1 (ascorbate).The developed method was applied for the assay of potassium, magnesium, calcium, aluminium, aspartate and ascorbate in pharmaceuticals and food-supplements. The accuracy of the method was evaluated using spiked samples (%recovery 95-105%, %R.S.D. < 2) and the absence of constant or proportional errors was confirmed by dilution experiments.  相似文献   

15.
A simple, rapid and sensitive method has been developed for the determination of aromatic low-molecular mass aldehydes (LMMAs) such as benzaldehyde (BA) and methyl derivatives in water samples through the use of liquid chromatography-diode array detection (LC-DAD). The method is based on the continuous in situ derivatization of the aldehydes with 2,4-dinitrophenylhydrazine (DNPH) on a LiChrolut EN solid-phase extraction (SPE) column in the presence of sodium dodecyl sulfate (SDS) micelles. After elution, hydrazones were successfully separated on a RP-C18 column using a linear gradient mobile phase of acetonitrile (ACN)-water at 75-95% ACN for 10 min. Linearity was established over the concentration range 0.4-200 μg L-1 and limits of detection (LODs) from 120 to 200 ng L-1; the inter-day precision expressed as the relative standard deviation (RSD) of the aldehydes ranged from 3.0% to 3.5%. The method was successfully applied to the analysis of aromatic and aliphatic LMMAs in water samples with average recoveries ranging between 93.6% and 99.5%. The proposed method surpasses other chromatographic alternatives in terms of LODs, sample requirements for analysis and cost.  相似文献   

16.
A highly selective sequential injection (SI) method for the automated determination of weak-acid-dissociable cyanides is reported. The analytical procedure is based on the on-line reaction of the analyte with ninhydrin in carbonate medium to form a coloured product (λmax = 510 nm). Cyanides are removed from sample matrix by acidification through a gas-diffusion step incorporated in the SI manifold. The effect of instrumental and chemical variables was studied. By adopting an on-line standard addition protocol, the sensitivity of the proposed method was enhanced drastically, without affecting the determination range. The assay was validated in terms of linearity (up to 200 μg L−1), limit of detection (cL = 2.5 μg L−1), limit of quantitation (cQ = 7.5 μg L−1), precision (sr < 2.5% at 100 μg L−1) and selectivity. High tolerance against critical species such as sulfides and thiocyanates was achieved. The applicability of the method was demonstrated by analyzing tap and mineral water samples at levels below the limits established by international E.U. and U.S. organizations. The percent recoveries were satisfactory in all cases, ranging between 94.2 and 103.6%.  相似文献   

17.
Primary amidation of N-protected phenylglycine and dipeptide proceeded easily to afford the corresponding amides in 57–95% yields with 99% ee and 81–99% de, respectively. The procedure is very easy to avoid racemization and epimerization of the products in the reactions by keeping exactly the reaction temperature at −15 °C when the activation of carboxylic acids, followed by the reaction of the mixed carbonic carboxylic anhydride with NH4Cl.  相似文献   

18.
In the present work dissociation constants of commonly used buffering species, formic acid, piperazine, tris(hydroxymethyl)–aminomethane, boric acid and carbonate, have been determined for several acetonitrile–water mixtures. From these pKa values a previous model has been successfully evaluated to estimate pH values in acetonitrile–aqueous buffer mobile phases from the aqueous pH and concentration of the above mentioned buffers up to 60% of acetonitrile, and aqueous buffer concentrations between 0.005 (0.001 mol L−1 for formic acid–formate) and 0.1 mol L−1. The relationships derived for the presently studied buffers, together with those established for previously considered buffering systems, allow a general prediction of the pH variation of the most commonly used HPLC buffers when the composition of the acetonitrile–water mobile phase changes during the chromatographic process, such as in gradient elution. Thus, they are an interesting tool that can be easily implemented in general retention models to predict retention of acid–base analytes and optimize chromatographic separations.  相似文献   

19.
Based on the characteristics of synchronous fluorescence spectroscopy (SFS), a new method with high sensitivity and selectivity was developed for rapid determination of silver ion with functional cadmium sulphide (CdS) nanoparticles as a fluorescence probe. When Δλ (λem − λex) = 215 nm, maximum synchronous fluorescence is produced at 304 nm. Under optimal conditions, functional cadmium sulphide displayed a calibration response for silver ion over a wide concentration range from 0.8 × 10−10 to 1.5 × 10−8 mol L−1. The limit of detection was 0.4 × 10−10 mol L−1 and the relative standard deviation of seven replicate measurements for the lowest concentration (0.8 × 10−10 mol L−1) was 2.8%. Compared with several fluorescence methods, the proposed method had a wider linear range and improved the sensitivity. Furthermore, the concentration dependence of the synchronous fluorescence intensity is effectively described by a Langmuir-type binding isotherm.  相似文献   

20.
A sensitive FIA method was developed for the selective determination of formaldehyde in alcoholic beverages. This method is based on the reaction of Fluoral-P (4-amine-3-pentene-2-one) with formaldehyde, leading to the formation of 3,5-diacetyl-1,4-dihydrolutidine (DDL), which fluoresces at λex = 410 nm and λem = 510 nm. The analytical parameters were optimized by the response surface method using the Box-Behnken design. The proposed flow injection system allowed for the determination of up to 3.33 × 10−5 mol L−1 of formaldehyde with R.S.D. < 2.5% and a detection limit of 3.1 ng mL−1. The method was successfully applied to determine formaldehyde in alcoholic beverages, without requiring any sample pretreatment, and the results agreed with the reference at a 95% confidence level by paired t-test. In the optimized condition, the FIA system proved able to analyze up to 60 samples/h.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号