首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Stochastic and deterministic simulations of dispersion in cylindrical channels on the Poiseuille flow have been presented. The random walk (stochastic) and the uniform dispersion (deterministic) models have been used for computations of flow injection analysis responses. These methods coupled with the genetic algorithm and the Levenberg–Marquardt optimization methods, respectively, have been applied for determination of diffusion coefficients. The diffusion coefficients of fluorescein sodium, potassium hexacyanoferrate and potassium dichromate have been determined by means of the presented methods and FIA responses that are available in literature. The best-fit results agree with each other and with experimental data thus validating both presented approaches.  相似文献   

2.
Two flow injection analyses (FIA) methods for the determination of diffusion coefficients in a straight single tube FIA system were developed. Based on the analytical solution of the convection-diffusion equation, linear relationships of the logarithmic values of the dispersion coefficient (D) and the half-peak width (W1/2) with the diffusion coefficient (Dm) were obtained. Experiments were designed to verify these methods. For example, for potassium hexacyanoferrate (III) a Dm value of 0.72 × 105 cm2 s−1 was found versus a literature value of 0.76 × 105 cm2 s−1 (error, 5%). For potassium hexacyanoferrate (II) a Dm value of 0.67 × 105 cm2 s−1 was obtained versus a literature value of 0.63 × 105 cm2 s−1 (error, 6%). The diffusion coefficients of some important biomedical compounds, such as dopamine, epinephrine, norepinephrine and ascorbic acid, were then determined. The values of 105 Dm/cm2 s−1 are 0.60 ± 0.03, 0.44 ± 0.02, 0.60 ± 0.01 and 0.68 ± 0.06, respectively.  相似文献   

3.
The diffusion coefficient of H2S in liquid sulfur is a key kinetic parameter that has been missing in literature. In this paper, a pressure decay method was applied to measure the diffusion coefficients of H2S in liquid sulfur at 403 and 423 K. This pressure decay process was then modeled by taking the simultaneous diffusion and reversible chemical reactions between H2S and liquid sulfur into consideration. The diffusion coefficients and reaction rate constants were numerically determined by fitting theoretical curves to experimental data using Finite Element Method and Genetic Algorithm. The solubility of H2S in liquid sulfur at 403 and 423 K was also calculated and the results agreed with the semi-empirical correlation lately reported in literature. This study further extended the validity of the correlation to higher partial H2S pressure conditions.  相似文献   

4.
Non-aqueous size exclusion chromatography (SEC) of polystyrenes (as model analytes) is examined using the microscale molar mass sensor (μ-MMS) for detection. The μ-MMS is combined with SEC to demonstrate this simultaneously universal and molar mass selective detection method for polymer characterization. The μ-MMS is based on measuring the refractive index gradient (RIG) at two positions (upstream and downstream) within a T-shaped microfluidic channel. The RIG is produced from a sample stream (eluting analytes in the mobile phase) merging with a mobile phase stream (mobile phase only). The magnitude of the RIG is measured as a probe beam deflection angle and is related to analyte diffusion coefficient, the time allowed for analyte diffusion from the sample stream toward the mobile phase stream, and the bulk phase analyte refractive index difference relative to the mobile phase. Thus, two deflection angles are measured simultaneously, the upstream angle and the downstream angle. An angle ratio is calculated by dividing the downstream angle by the upstream angle. The μ-MMS was found to extend the useful molar mass calibration range of the SEC system (nominally limited by the total exclusion and total permeation regions from ∼100,000 g/mol to ∼800 g/mol), to a range of 3,114,000-162 g/mol. The injected concentration LOD (based on 3 s statistics) was 2 ppm for the upstream detection position. The point-by-point time-dependent ratio, termed a ‘ratiogram’, is demonstrated for resolved and overlapped peaks. Within detector band broadening produces some anomalies in the ratiogram shapes, but with highly overlapped distributions of peaks this problem is diminished. Ratiogram plots are converted to molar mass as a function of time, demonstrating the utility of SEC/μ-MMS to examine a complex polymer mixture.  相似文献   

5.
This article reviews novel quantification concepts where elemental labelling is combined with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS) or liquid chromatography inductively coupled plasma mass spectrometry (LC–ICP-MS), and employed for quantification of biomolecules such as proteins, peptides and related molecules in challenging sample matrices. In the first sections an overview on general aspects of biomolecule quantification, as well as of labelling will be presented emphasizing the potential, which lies in such methodological approaches. In this context, ICP-MS as detector provides high sensitivity, selectivity and robustness in biological samples and offers the capability for multiplexing and isotope dilution mass spectrometry (IDMS). Fundamental methodology of elemental labelling will be highlighted and analytical, as well as biomedical applications will be presented. A special focus will lie on established applications underlining benefits and bottlenecks of such approaches for the implementation in real life analysis. Key research made in this field will be summarized and a perspective for future developments including sophisticated and innovative applications will given.  相似文献   

6.
Reversed‐phase liquid chromatography coupled with electrospray ionization mass spectrometry was used to study the molecular structures of components and molar mass distributions in ethyl silicate‐40, a versatile liquid precursor for silicon‐based materials. Identity testing by standard spectroscopic techniques showed that a commercial sample of ethyl silicate‐40 was composed of linear/branched ethoxysiloxane oligomers with the silicon atoms ranging from 2 to 12 together with minor monocyclic species. Analysis of the sample by liquid chromatography coupled with evaporative light scattering detection resulted in an elution profile consisting of a series of peak clusters. Peak identification showed that the linear/branched homologous series of oligomers were eluted in the order of increasing number of silicon atoms in the molecules and the time duration (width) of the resulting peak clusters increased in the same fashion corresponding to increasing number of geometric isomers. In addition, small amounts of monocyclic oligomers present in the sample were found to be less retained than each linear/branched counterpart. Finally, the molar mass distribution parameters for ethyl silicate‐40 determined by the developed method were in good agreement with the literature values. Overall, this work demonstrates that reversed‐phase liquid chromatography coupled with electrospray ionization mass spectrometry is an indispensable tool for the comprehensive characterization of complex mixtures of this type.  相似文献   

7.
A novel integrated chemiluminescence (CL) flow sensor for the determination of adrenaline and isoprenaline is developed based on the enhancing effect of analytes on CL emission of luminol oxidized by periodate in alkaline solution. The analytical reagents luminol and periodate are immobilized on anion exchange resins, respectively, and packed in a glass tube to construct a reagentless sensor. The proposed sensor allows the determination of adrenaline and isoprenaline over the range from 2.0×10−8 to 1.0×10−5 g ml−1 and 2.0×10−7 to 5.0×10−5 g ml−1, respectively. The detection limits are 7.0×10−9 g ml−1 for adrenaline and 5.0×10−8 g ml−1 for isoprenaline with a relative standard deviation of 1.7% for the 1.0×10−7 g ml−1 adrenaline (n=11) and 2.1% for 1.0×10−6 g ml−1 isoprenaline (n=11). The sample throughput was 60 samples h−1. The sensor has been successfully applied to the determination of adrenaline and isoprenaline in pharmaceutical preparations.  相似文献   

8.
The diffusion coefficient of methylene blue (MB) is determined by the method of non-probe microelectrode voltammetry in sodium dodecyl sulfate (SDS)/n-C5H11OH/H2O lyotropic liquid crystal system. The results obtained show that the diffusion coefficient of MB increases with water and n-pentanol contents in the microemulsions and the lyotropic liquid crystal but decreases with SDS content. The diffusion coefficient of SDS droplet in the microemulsions and the diffusion coefficient of SDS molecule in the lyotropic liquid crystal with MB all are less than those without MB. The magnitude order of the diffusion coefficient of MB is as follows: the coefficient in the oil-in-water (O/W) microemulsion is greater than the coefficient in the water-in-oil (W/O) microemulsion which is greater than the coefficient in the lamellar liquid crystal (LLC), which is also greater than the coefficient in the Hex.  相似文献   

9.
This document is a glossary of terms for separations coupled to mass spectrometry. It covers gas chromatography/mass spectrometry, liquid chromatography/mass spectrometry, and supercritical fluid chromatography/mass spectrometry and the sample introduction, ionization, and data analysis methods used with these combined techniques.  相似文献   

10.
本文提出了连续环状色谱分离过程的参数辨识方法,包括其轴向扩散系数的辨识模型,以惰性物CaCl2作示踪剂,001×7树脂为填料,采用扰动-应答法技术在环状色谱床中测定轴向扩散系数。考虑轴向扩散的作用,建立了线性吸附平衡体系的相平衡常数及总传质系数的辨识模型,并对木糖──山梨糖体系,采用扰动-应答技术测定相平衡常数及总传质系数。考察了操作因素对轴向扩散系数与总传质系数的影响规律。结果表明,流速增加,轴向扩散系数加大,环状色谱床中的流动明显地偏离理想活塞流;流速增加,总传质系数也相应增大。  相似文献   

11.
Alkyd resins have been commonly used as binders in artist paints since the 1940s. The characterization of alkyds in samples from artworks can help to solve attribution and dating issues, investigate decay processes, and contribute to the planning of conservation strategies. Being able to assess the components of industrially formulated paint materials and to differentiate between different trademarks and producers is extremely interesting and requires multi-analytical approaches.  相似文献   

12.
The present study aims to describe and exemplify an integrated strategy of the combination of qualitative and quantitative characterization of a multicomponent mixture for the quality control of traditional Chinese medicine injections with the example of Danhong injection (DHI). The standardized chemical profile of DHI has been established based on liquid chromatography with diode array detection. High‐performance liquid chromatography coupled with time‐of‐flight mass spectrometry and high‐performance liquid chromatography with electrospray multistage tandem ion‐trap mass spectrometry have been developed to identify the major constituents in DHI. The structures of 26 compounds including nucleotides, phenolic acids, and flavonoid glycosides were identified or tentatively characterized. Meanwhile, the simultaneous determination of seven marker constituents, including uridine, adenosine, danshensu, protocatechuic aldehyde, p‐coumaric acid, rosmarinic acid, and salvianolic acid B, in DHI was performed by multiwavelength detection based on high‐performance liquid chromatography with diode array detection. The integrated qualitative and quantitative characterization strategy provided an effective and reliable pattern for the comprehensive and systematic characterization of the complex traditional Chinese medicine system.  相似文献   

13.
A simple, rapid, and environmentally friendly method was developed for the determination of acrylamide and trimethylolpropane in paper packaging materials. No organic solvent was used and the matrix effect was investigated. The extract was directly analyzed by liquid chromatography with tandem mass chromatography for quantification and confirmation. The chromatographic separations were performed on a ZORBAX HILIC Plus (2.1 mm × 150 mm, 3μm; Agilent, USA) column with only one mobile phase (100% water). Calibration curves for acrylamide and trimethylopropane were achieved with concentrations ranging from 0.4 to 20 mg/kg and the corresponding r2 values were 0.998 and 0.999, respectively. The recoveries were >85% with relative standard deviations <10%. The validated method was applied to the analysis of 50 real samples, and positive results were obtained for 30 samples. The result indicated that trimethylolpropane is associated with inks and printing activity and acrylamide is widely used as a papermaking additive in many paper packages. The concentrations of acrylamide and trimethylolpropane ranged from 0.41 to 7.5 and 0.50 to 8.8 mg/kg, respectively. The results of this study revealed that this method could be used accurately and precisely.  相似文献   

14.
The reports of this series tabulate a number of features of analytical instruments that should be considered when making comparison between various systems. Scoring these features in a rational manner allows a scientific comparison to be made between instruments as an aid to selection. This is the XXIInd report of the series and deals with instrumentation for liquid chromatography/mass spectrometry.  相似文献   

15.
Mayer-Helm B  Hofbauer L  Müller J 《Talanta》2008,74(5):1184-1190
A method was developed for the quantitative determination of alachlor, benalaxyl, clomazone, diflubenzuron, dimethomorph, diphenamid, ethofumesate, metalaxyl, methoprene, metobromuron and piperonyl butoxide on tobacco. The pesticides were extracted with water and methanol from five different types of tobacco. The extracts were purified by partition on an extraction cartridge containing diatomaceous earth. The purified extracts were analysed by reversed-phase high-performance liquid chromatography connected to an atmospheric pressure ionisation–electrospray-triple quadrupole mass spectrometer operating in the positive ion mode. Two different transitions and their relative intensities were monitored for unambiguous identification. All pesticides presented overall recovery rates between 35% and 110%. The trueness is near 100% and the interday precision is below 15%. The limits of quantifications are equal or below the guidance residue levels proposed by the Agrochemical Advisory Committee of CORESTA, an association of organisations having scientific research relative to tobacco.  相似文献   

16.
Liquid chromatography with time-of-flight mass spectrometry (LC-TOF-MS) method has been developed for simultaneous confirmation by accurate mass measurement and quantitative determination of antibiotics (enrofloxacin, oxolinic acid, flumequine, erythromycin), fungicides (malachite green MG, leucomalachite green LMG) and parasiticide (emamectin benzoate) residues in edible portion of salmon. Confirmation of chemotherapeutant residues has been based on the system of identification points (IPs) established in the Commission Decision 2002/657/EC concerning the use of mass spectrometry (MS) techniques. A validation study on matrix is presented evaluating accuracy in terms of precision (λppm 0.83-1.15) and trueness (0.22-0.70 Da). Limits of detection (LODs) and limits of quantification (LOQs) were in ranges of 1-3 and 3-9 μg/kg, below the maximum residue limits (MRLs) established in current EU legislation (100-200 μg/kg) for these chemotherapeutants. Considering the EU guidelines, decision limits (CCα) and detection capabilities (CCβ) were determined (ranges of 103-218 and 107-234 μg/kg, respectively) for authorised substances. For no authorised compounds (MG and LMG), LODs were 2 and 1 μg/kg, respectively, but exceed the MRPL (minimum required performance limit) established in the legislation which corresponds to the sum of MG and LMG (2 μg/kg). Acceptable intra-day and inter-day variability, in terms of relative standard deviation (R.S.D.) of the analytical method, were obtained (2-15%). Linearity was demonstrated from the LOQs of the analytes to 600 μg/kg (r > 0.9991). The method has involved an extraction procedure based on solid-liquid extraction (SLE) with recoveries higher than 80% for most target chemotherapeutants, with exception of enrofloxacin (40%).  相似文献   

17.
《Analytical letters》2012,45(8):1334-1347
This paper presents the development and optimization of a liquid chromatographic method for the determination of fluconazole and its impurities by experimental design methodology. Four experimental design types were applied: two-level full factorial design, central composite design, Box-Behnken design, and three-level full factorial design. The advantages and drawbacks of each design are described and detailed statistical evaluation of mathematical models was performed. The central composite design and three-level full factorial design created significantly better models comparing to the other methods. As the central composite design requires a smaller number of experiments, its models were used for theoretical examination of experimental space. Multiobjective optimization aiming to achieve maximal separation of all investigated substances and minimal analysis duration was performed by a grid point search. The defined optimal separation was achieved on a C18 (125 mm × 4 mm, 5 µm particle size) column with a mobile phase consisting of acetonitrile and water (5 mM ammonium formate) (15:85, v/v); a column temperature of 25°C; a flow rate of 1.2 mL min?1; and a detection wavelength of 260 nm.  相似文献   

18.
19.
Zeng D  Shen X  He L  Ding H  Tang Y  Sun Y  Fang B  Zeng Z 《Journal of separation science》2012,35(10-11):1327-1335
A rapid liquid chromatography tandem mass spectrometric method was developed for the simultaneous determination of mequindox and its five metabolites (2-isoethanol mequindox, 2-isoethanol 1-desoxymequindox, 1-desoxymequindox, 1,4-bisdesoxymequindox, and 2-isoethanol bisdesoxymequindox) in porcine muscle, liver, and kidney, fulfilling confirmation criteria with two transitions for each compound with acceptable relative ion intensities. The method involved acid hydrolysis, purification by solid-phase extraction, and subsequent analysis with liquid chromatography tandem mass spectrometry using electrospray ionization operated in positive polarity with a total run time of 15 min. The decision limit values of five analytes in porcine tissues ranged from 0.6 to 2.9 μg/kg, and the detection capability values ranged from 1.2 to 5.7 μg/kg. The results of the inter-day study, which was performed by fortifying porcine muscle (2, 4, and 8 μg/kg), liver, and kidney (10, 20, and 40 μg/kg) samples on three separate days, showed that the accuracy of the method for the various analytes ranged between 75.3 and 107.2% with relative standard deviation less than 12% for each analyte.  相似文献   

20.
An alternative method for the enantiomer specific determination of hexabromocyclododecanes (HBCD) by LC-ESI-MS/MS using an ion trap analyser is proposed. The method is based on the formation of a chlorine adduct (m/z 676.6) of the (±)α-, (±)β-, and (±)γ-HBCD enantiomers and their further fragmentation into their stable quasi-molecular ion (m/z 640.6). In this way, problems related to the ion trap low mass cutoff and variable amounts of other adduct peaks in the samples are solved. Parameters affecting separation, ionisation and MS/MS detection were studied. Method performance was also evaluated: calibration curves were found linear from 20 to 400 pg μL−1 for each enantiomer; detection limits ranged between 1.5 and 4.3 pg μL−1; repeatability and reproducibility, expressed as relative standard deviation, were lower than 6% and 13%, respectively. The application to different types of spiked samples (pork meat, lean fish, and butter) pointed out the occurrence of matrix effects that could be solved by using labelled standards.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号