首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple analytical procedure based on single-drop microextraction combined with in-syringe derivatization and GC-MS was developed for determination of some phenolic acids in fruits and fruit juices. Cinnamic acid, o-coumaric acid, caffeic acid, and p-hydroxybenzoic acid were used as model compounds. The analytes were extracted from a 3-mL sample solution using 2.5 microL of hexyl acetate. The extracted phenolic acids were derivatized inside the syringe barrel using 0.7 microL of N,O-bis(trimethylsilyl)acetamide before injection into the GC-MS. The influence of derivatization conditions on the yield of in-syringe silylation was studied. Experimental SDME parameters such as selection of organic solvent, solvent volume, extraction time, extraction temperature, pH, and ionic strength of the solution on the extraction performance were studied. The method provided fairly good precision for all compounds (2.4-11.9%). Detection limits were found to be between 0.6 and 164 ng/mL within an extraction time of 20 min in the GC-MS full scan mode.  相似文献   

2.
Quantification of trace concentrations of transformation products of rocket fuel unsymmetrical dimethylhydrazine (UDMH) in water requires complex analytical instrumentation and tedious sample preparation. The goal of this research was to develop a simple and automated method for sensitive quantification of UDMH transformation products in water using headspace (HS) solid-phase microextraction (SPME) in combination with GC-MS and GC-MS/MS. HS SPME is based on extraction of analytes from a gas phase above samples by a micro polymer coating followed by a thermal desorption of analytes in a GC inlet. Extraction by 85 µm Carboxen/polydimethylsiloxane fiber at 50 °C during 60 min provides the best combination of sensitivity and precision. Tandem mass spectrometric detection with positive chemical ionization improves method accuracy and selectivity. Detection limits of twelve analytes by GC-MS/MS with chemical ionization are about 10 ng L?1. GC-MS provides similar detection limits for five studied analytes; however, the list of analytes detected by this method can be further expanded. Accuracies determined by GC-MS were in the range of 75–125% for six analytes. Compared to other available methods based on non-SPME sample preparation approaches (e.g., liquid–liquid and solid-phase extraction), the developed method is simpler, automated and provides lower detection limits. It covers more UDMH transformation products than available SPME-based methods. The list of analytes could be further expanded if new standards become available. The developed method is recommended for assessing water quality in the territories affected by space activities and other related studies.  相似文献   

3.
A solid-phase extraction (SPE) method was developed for the simultaneous extraction of dicarboxylic acids and diols formed during hydrolysis of poly(butylene succinate), PBS, and poly(butylene adipate), PBA. Four commercial non-polar SPE columns, three silica based: C8, C18, C18 (EC), and one resin based: ENV+, were tested for the extraction of succinic acid, adipic acid and 1,4-butanediol, the expected final hydrolysis products of PBS and PBA. ENV+ resin was chosen as a solid-phase, because it displayed the best extraction efficiency for 1,4-butanediol and succinic acid. Linear range for the extracted analytes was 1-500 ng/microl for adipic acid and 2-500 ng/microl for 1,4-butanediol and succinic acid. Detection and quantification limits for the analytes were between 1-2 and 2-7 ng/microl, respectively, and relative standard deviations were between 3 and 7%. Good repeatability and low detection limits made the developed SPE method and subsequent gas chromatography-mass spectrometry (GC-MS) analysis a sensitive tool for identification and quantification of hydrolysis products at early stages of degradation.  相似文献   

4.
Helaleh MI  Fujii S  Korenaga T 《Talanta》2001,54(6):1039-1047
In solid phase micro-extraction (SPME), the analyte is partitioned between the coating and the sample and then desorption of the concentrated analyte is followed by GC-MS, where the analytes are thermally desorbed and subsequently separated on the column and quantified by the detector. The SPME method preserves all the advantages, such as simplicity, low cost, on site sampling and does not require solvents. Poly(acrylate) coating fibers have been developed for the extraction of phenols (such as 4-tert-butylphenol, 2,4-dichlorophenol, 4-n-pentylphenol, 4-n-hexylphenol, 4-tert-octylphenol, 4-n-heptylphenol, 4-n-nonylphenol, 4-n-octylphenol, pentachlorophenol and bisphenol A) in different water samples. The precision of the HS-SPME method ranges from 3–12% RSDs, depending on the compounds analyzed. More accurate results were obtained by HS-SPME with acidification and salting out, where the fiber is located above the liquid sample. The extraction period was 60 min, followed by desorption for 5 min at 300°C. After the analytes were completely desorbed, 1 μl of bis(trimethylsilyl)trifluoroacetamide (BSTFA) was injected by ordinary GC-MS injection. The trimethylsilylate peaks were improved significantly compared with free phenol peaks. The addition of salt (saturated sodium chloride) and acidification by hydrochloric acid (pH 2.0) were found to be very important for enhancing the partitioning of the polar phenols into the polymer coating and preventing ionization of the analytes. The method is capable of limits of detection of subparts per billion of the total phenols extracted from environmental water samples.  相似文献   

5.
A method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the direct quantification of glucuronides of testosterone (TG), epitestosterone (EPG), androsterone (AG) and etiocholanolone (ETG) has been developed. The method allowed for the direct determination of these analytes avoiding hydrolysis and derivatization, which are usual steps in commonly used methods based on gas chromatography-mass spectrometry (GC-MS). The electrospray ionization and the product ion spectra of the glucuronides have been studied in order to obtain the most specific transitions. The use of the selected transitions is necessary for the determination of the analytes at low ng/ml concentration levels. Two different approaches have been tested for sample preparation: direct injection after filtration and acidic liquid-liquid extraction (LLE) with ethyl acetate. Both approaches have been validated obtaining satisfactory values for accuracy and precision with limits of detection lower than 1 ng/ml for TG and EPG. Ion suppression was more pronounced after LLE probably due to the concentration of interferences from acidic urine. The applicability of the method has been checked by the analysis of 40 urine samples. The results were compared with those obtained with the common GC-MS method. Results have shown a good correlation between both methods with correlation coefficients higher than 0.97. A slope close to 1 was obtained for all analytes except for AG possibly due to losses during the extraction process prior to GC-MS.  相似文献   

6.
A headspace solid-phase microextraction (HS-SPME) method for the determination of 12 haloanisoles in wine and spirit samples using gas chromatography with atomic emission detection (GC-AED) was developed. The different factors affecting the efficiency of the extraction were carefully optimized. The divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber was the most suitable for preconcentrating the analytes from the headspace of the sample solution. Sample:water dilutions of 3:4 and 1:6 for wines and spirits, respectively, and the use of a mixed bromochloroanisole compound as internal standard allowed sample quantification against external standards prepared in the presence of 5% (v/v) ethanol. Detection limits ranged from 1.2 to 18.5ngL(-1), depending on the compound and the sample analyzed, with a fiber time exposure of 60min at 75 degrees C. The optimized method was successfully applied to different samples, and several of the studied haloanisoles were detected at concentration levels ranging from 10.3ngL(-1) to 1.14ngmL(-1).  相似文献   

7.
The advent of policies that incentivize or require alternative diesel fuels has increased the demand for the development of fast analytical methods aiming for the quality control of these fuels. This study approached an alternative method for the determination of biodiesel acidity employing capillary zone electrophoresis based on free fatty acids screening and quantification. Sample preparation comprised vortex-assisted liquid-liquid extraction of free fatty acids and was a crucial step for analysis. It was studied through a 32 full factorial design considering sample mass and the stirring time. Then, solvent suitability was evaluated univariately. The free fatty acid screening was carried out employing a capillary zone electrophoresis method able to separate C16:0, C18:0, C18:1 n-9, C18:2 n-6, and C18:3 n-3, major fatty acids in a variety of vegetable oils used for biodiesel synthesis. In addition to the straightforward sample preparation protocol, the running time of the developed method was only 12 min. Moreover, ultraviolet absorption indirect detection of analytes was approached to avoid analytes derivatization, considering the lack of chromophore groups in saturated fatty acids. Statistical tests did not evidence any significant differences in the biodiesel acidity determination expressed in percentage of free fatty acids when comparing the proposed capillary zone electrophoresis method and the traditional potentiometric titration approach within the 95% confidence interval, which demonstrates the suitability of this alternative method for the biodiesel quality control in routine.  相似文献   

8.
A simple and sensitive method has been developed and validated for determining ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA), isobutyl methylphosphonic acid (iBuMPA), and pinacolyl methylphosphonic acid (PMPA) in human urine using gas chromatography-tandem mass spectrometry (GC-MS/MS) coupled with solid phase derivatization (SPD). These four alkyl methylphosphonic acids (AMPAs) are specific hydrolysis products and biomarkers of exposure to classic organophosphorus (OP) nerve agents VX, sarin, RVX, and soman. The AMPAs in urine samples were directly derivatized with pentafluorobenzyl bromide on a solid support and then extracted by liquid–liquid extraction. The analytes were quantified with isotope-dilution by negative chemical ionization (NCI) GC-MS/MS in a selected reaction monitoring (SRM) mode. This method is highly sensitive, with the limits of detection of 0.02 ng/mL for each compound in a 0.2 mL sample of human urine, and an excellent linearity from 0.1 to 50 ng/mL. It is proven to be very suitable for the qualitative and quantitative analyses of degradation markers of OP nerve agents in biomedical samples.  相似文献   

9.
The present report describes a method for the quantification of N-acetyl- and N-glycolylneuraminic acids without any derivatization, using their (13)C(3)-isotopologues as internal standards and a C(18) reversed-phase column modified by decylboronic acid which allows for the first time a complete chromatographic separation between the two analytes. The method is based on high-performance liquid chromatographic coupled with electrospray ion-trap mass spectrometry. The limit of quantification of the method is 0.1mg/L (2.0ng on column) for both analytes. The calibration curves are linear for both sialic acids over the range of 0.1-80mg/L (2.0-1600ng on column) with a correlation coefficient greater than 0.997. The proposed method was applied to the quantitative determination of sialic acids released from fetuin as a model of glycoproteins.  相似文献   

10.
Selective extraction and enrichment of nerve agent degradation products has been achieved using zirconia based commercial solid-phase extraction cartridges. Target analytes were O-alkyl alkylphosphonic acids and alkylphosphonic acids, the environmental markers of nerve agents such as sarin, soman and VX. Critical extraction parameters such as modifier concentration, nature and volume of washing and eluting solvents were investigated. Amongst other anionic compounds, selectivity in extraction was observed for organophosphorus compounds. Recoveries of analytes were determined by GC-MS which ranged from 80% to 115%. Comparison of zirconia based solid-phase extraction method with anion-exchange solid-phase extraction revealed its selectivity towards phosphonic acids. The limits of detection (LOD) and limit of quantification (LOQ) with selected analytes were achieved down to 4.3 and 8.5 ng mL(-1), respectively, in selected ion monitoring mode.  相似文献   

11.
In the present work two second-order calibration methods, generalized rank annihilation method (GRAM) and multivariate curve resolution-alternating least square (MCR-ALS) have been applied on standard addition data matrices obtained by gas chromatography-mass spectrometry (GC-MS) to characterize and quantify four unsaturated fatty acids cis-9-hexadecenoic acid (C16:1ω7c), cis-9-octadecenoic acid (C18:1ω9c), cis-11-eicosenoic acid (C20:1ω9) and cis-13-docosenoic acid (C22:1ω9) in fish oil considering matrix interferences. With these methods, the area does not need to be directly measured and predictions are more accurate. Because of non-trilinear conditions of GC-MS data matrices, at first MCR-ALS and GRAM have been used on uncorrected data matrices. In comparison to MCR-ALS, biased and imprecise concentrations (%R.S.D. = 27.3) were obtained using GRAM without correcting the retention time-shift. As trilinearity is the essential requirement for implementing GRAM, the data need to be corrected. Multivariate rank alignment objectively corrects the run-to-run retention time variations between sample GC-MS data matrix and a standard addition GC-MS data matrix. Then, two second-order algorithms have been compared with each other. The above algorithms provided similar mean predictions, pure concentrations and spectral profiles. The results validated using standard mass spectra of target compounds. In addition, some of the quantification results were compared with the concentration values obtained using the selected mass chromatograms. As in the case of strong peak-overlap and the matrix effect, the classical univariate method of determination of the area of the peaks of the analytes will fail, the “second-order advantage” has solved this problem successfully.  相似文献   

12.
Phthalate esters are additives used in polyvinylchloride and are found as contaminants in many food products. An isotope dilution mass spectrometry technique has been developed for accurate analysis of 16 phthalate esters in Chinese spirits by adopting the 16 corresponding isotope‐labeled phthalate esters. The ethanol in the spirit sample was first removed by heating with a water bath at 100°C with a stream of nitrogen, after which the residue was extracted with n‐hexane twice. The phthalates collected were identified and quantified by gas chromatography with tandem mass spectrometry in multiple reaction monitoring mode. The spiking recoveries of 16 analytes ranged from 94.3 to 105.3% with relative standard deviation values of <6.5%. The detection limits for 16 analytes were <10.0 ng/g. The expanded relative uncertainties were from 3.0 to 14%. A survey was performed on Chinese spirits from the market. Six of the nine analyzed samples were contaminated by phthalates. Di‐n‐butyl phthalate and di‐2‐ethylhexyl phthalate showed higher detection frequency and concentrations. This isotope dilution gas chromatography with tandem mass spectrometry method is simple, rapid, accurate, and highly sensitive, which qualifies as a candidate reference method for the determination of phthalates in spirits.  相似文献   

13.
New methods based on nonaqueous capillary electrophoresis (NACE) were developed as promising alternatives for the simultaneous separation and determination of p-hydroxybenzoic acid (PHBA) and a group of parabens (methyl, ethyl, propyl, butyl and benzyl p-hydroxybenzoates), with good resolution and excellent sensitivity. As an effective on-line preconcentration technique, large-volume sample stacking (LVSS) was successfully combined with NACE allowing significant sensitivity enhancement. Identification and quantification of the analytes were performed by diode array detection (DAD). The influence of different parameters, such as buffer apparent pH, concentration of electrolyte, temperature, applied voltage and sample volume, on the efficiency, resolution and sensitivity of the electrophoretic separation was studied. The analytical performance was evaluated, and both NACE-DAD and LVSS-NACE-DAD methods showed good linearity, precision and instrumental LODs at low ng/mL levels. These LODs were compared with those described in the literature, and it was found that NACE-DAD method was comparable to GC-MS, while LVSS-NACE-DAD procedure achieved sensitivity similar to LC-MS, LC-MS/MS and GC-MS/MS, even using conventional ultraviolet-visible absorption detection. To test their suitability, proposed methods were evaluated for the analysis of PHBA and parabens at low and sub-ng/mL levels in environmental water samples.  相似文献   

14.
A CE-MS method for metabolic profiling of amino acids was developed and used in an integrated functional genomics project to study the response of Medicago truncatula liquid suspension cell cultures to stress. This project required the analysis of more than 500 root cell culture extracts. The CE-MS method profiled 20 biologically important amino acids. The CE-MS method required no sample derivatization prior to injection and used minimal sample preparation. The method is described in terms of CE and MS operational parameters, reproducibility of migration times and response ratios, sample preparation, sample throughput, and reliability. This method was then compared with a previously published report that used GC-MS metabolic profiling for the same tissues. The data reveal a high level of similarity between the CE-MS and GC-MS amino acid profiling methods, thus supporting these as complementary technologies for metabolomics. We conclude that CE-MS is a valid alternative to GC-MS for targeted profiling of metabolites, such as amino acids, and possesses some significant advantages over GC-MS.  相似文献   

15.
猪肉中63种有机磷农药的气相色谱筛选与气质联用确证方法   总被引:19,自引:1,他引:19  
建立了固相萃取-气相色谱筛选和气相色谱-质谱联用确证猪肉中63种有机磷农药的分析方法。样品用正己烷配合乙腈-水溶液均质提取,加入氯化钠继续均质,离心分层后取部分乙腈层经C18柱和PSA柱净化后供GC和GC-MS分析。气相色谱筛选采用火焰光度检测器(FPD),气相色谱-质谱联用确证采用选择离子扫描方式(SIM),外标法定量。该方法简便、快速,优化条件下测定方法的定量下限(S/N=10)为0.001~0.043 mg/kg,在加标水平为0.16 mg/kg时,回收率为70%~121%,相对标准偏差为4.1%~13.9%。  相似文献   

16.
Solid-phase microextraction coupled to GC-MS was optimised for the determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters and polychlorinated biphenyls (PCBs) in water samples. A 30-microm polydimethylsiloxane fiber was immersed in a 30-ml water sample that contained the analytes of interest (PAHs, PCBs and phthalate esters) and the variables studied were extraction time (15-60 min), extraction temperature (30-90 degrees C), desorption time (1-5 min), desorption temperature (220-270 degrees C) and the addition of sodium chloride (0-9 g). The MultiSimplex programme based on the simplex algorithm was used to establish the optimal conditions. MultiSimplex allowed the simultaneous study of the variables mentioned above and considered the answers of all types of compounds studied in this work. Thus, the optimal conditions obtained allowed the simultaneous determination of PAHs, phthalate esters and PCBs. Furthermore, the accuracy and repeatability of the developed method were calculated from water samples spiked at known concentrations of the analytes. Finally, the optimised method was used to analyse water samples from different sampling points of the Urdaibai and Nerbioi-Ibaizabal estuaries (Biscay, Spain).  相似文献   

17.
Detection and identification of environmental signatures of chemical warfare agents is an important aspect of verification program of Chemical Weapons Convention (CWC). Alkylphosphonic acids (APAs) are ultimate and persistent degradation products of nerve agents. Their identification in a sample submitted for off-site analysis infers possible indication of contamination with nerve agents. This paper describes the development of a new sample preparation method which involves 'in situ derivatization and extraction' (INDEX) of acids from water. Derivatization is performed by alkylation of APAs with alkylbromides in surfactant less microemulsion (SLME). The derivatized analytes were analyzed by gas chromatography coupled with mass spectrometry. The developed method involves simultaneous derivatization (alkylation) and extraction of acidic analytes mediated by surfactant less microemulsion. Various derivatization-extraction parameters such as solvent, reaction time and temperature, base and alkyl bromides were optimized. Pentyl bromide in the presence of potassium carbonate and diisopropylamine at 100 degrees C derivatized the selected acids efficiently. Kinetic data for alkylation of methylphosphonic acids and some carboxylic acids were obtained to assess their relative susceptibility for alkylation in microemulsion. Methylphosphonic acid and isopropyl methylphosphonic acid took 140-150 min to reach completion while carboxylic acids took 100 min to complete the reaction. INDEX could be successfully performed even in the presence of interfering Ca(2+) and Mg(2+) ions.  相似文献   

18.
微波消解同时衍生化GC-MS法测定血浆中脂肪酸的研究   总被引:3,自引:0,他引:3  
研究了利用微波能对样品进行加热, 以H2SO4 - 甲苯- 甲醇体系作衍生化试剂, 在消化的同时对血浆中的脂肪酸进行衍生化, 然后用GC- MS 法测定血浆中脂肪酸。 对微波功率、微波加热时间、消解及衍生化试剂等条件进行了优化, 测定结果较好。该法整个消化及衍生化过程只需2 min , 与传统方法相比大大缩短了实验操作时间, 特别适用于大量样品的测定。  相似文献   

19.
Matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry was used for the rapid detection of cocaine, benzoylecgonine and cocaethylene in hair. Different MALDI sample preparation procedures have been tested and the employment of a multi-layer 'graphite-sample-electrosprayed alpha-cyano-4-hydroxycinnamic acid (HCCA)' yielded the best results for standard solutions of the target analytes. The same approach was subsequently applied to hair samples that were known to contain cocaine, benzoylecgonine and cocaethylene, as determined by a classical GC-MS method. It was however necessary to extract hair samples by incubating them in methanol/trifluoroacetic acid for a short time (15 min) at 45 degrees C; 1 microl of the obtained supernatant was deposed on a metal surface treated with graphite, and HCCA was electrosprayed on it. This procedure successfully suppressed matrix peaks and was effective in detecting all the target analytes as their protonated species. The results obtained give further confirmation of the effectiveness of the MALDI for detecting drugs and their metabolites in complex biological matrices. The method can be useful as a fast screening procedure to detect the presence of cocaine and metabolites in hair samples.  相似文献   

20.
侯英  杨蕾  王保兴  徐济仓  杨勇  杨燕  曹秋娥  谢小光 《色谱》2006,24(6):601-605
应用搅拌棒吸附萃取法(SBSE)提取烟用香料的化学成分,并利用热脱附(TD)和色谱-质谱联用(GC-MS)进行分析。对影响萃取效果的因素(萃取时间和氯化钠的加入量)进行了考察,并采用正交试验法对影响热脱附的3个主要因素(脱附温度、脱附时间和冷阱温度)进行了优化,得到了较优的实验条件。对方法的重现性进行了考察,同一样品6次测定所得30个组分的峰面积的相对标准偏差(RSD)平均值小于10%,说明所建立方法的重现性较好。在样品中鉴别出酯类、酮类和醛类等30种不同化学组分,这些物质反映了该香料的香气特点。实验证明SBSE和TD适用于烟用香料的快速分析测定。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号