首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 247 毫秒
1.
An efficient and simple method for the determination of furan in baby-food (vegetables and fruits) by solid phase micro-extraction-gas chromatography-mass spectrometry (SPME-GC-MS) was developed and validated. Experimental design was used to investigate the effects of temperature and time of extraction. The calculated regression model was used to find the experimental conditions providing the optimal SPME extraction yield. Validation was carried out in terms of limit of detection (LOD), limit of quantitation (LOQ), linearity, precision and trueness. LOD and LOQ values in the low ngkg(-1) were achieved, whereas linearity was established over two order of magnitude. Good precision was obtained both in terms of intra-day repeatability and between-day precision on two concentration levels (RSD% lower than 3.6%). Recovery values of 91.5+/-6.2% and of 96.1+/-1.3% (n=3) were calculated at 75 ngkg(-1) and 75 microgkg(-1) level. Finally, the applicability of the method to the determination of furan in a number of commercial and home-made baby-food samples was demonstrated.  相似文献   

2.
A rapid and accurate method using reversed-phase liquid chromatography-tandem mass spectrometry interfaced with electrospray was developed for determination of acrylamide in cooked food samples. A simplified sample treatment procedure using an extraction step with acidified water without cleanup was developed. A C18 column with an aqueous formic acid-methanol mixture as the mobile phase was used under isocratic conditions. The method was validated in-house for robustness, limits of detection (LOD) and quantitation (LOQ), linearity, recovery, and accuracy both on standard and baked-product and potato flour matrixes. Good results in the low ppb level were obtained for LOD (< 15 microg/kg) and LOQ (< 25 microg/kg) of acrylamide in samples. Excellent linearity (r2 = 0.999-1.000) was established over 2 orders of magnitude by performing statistical tests. The absence of both constant and proportional systematic errors demonstrated good method accuracy. Excellent results were obtained for intraday repeatability (RSD < 1.5%) and between-day precision (RSD < 5%). Extraction recoveries from food products were calculated in the 97 +/- 3-99 +/- 2% (n = 6) range with a labeled internal standard (13C3-acrylamide). The applicability of the method to determination of acrylamide in cooked food products was demonstrated.  相似文献   

3.
A simple and specific method for the simultaneous determination of eleutherosides B and E in powdered rhizomes of Eleutherococcus senticosus extract and in solid and liquid dietary supplements was developed and validated. E. senticosus extracts, often mixed with other plants or herbal extracts, are widely used in food supplements because of the tonic and adaptogenic activities referred to the eleutherosides B and E. In this study, samples were analyzed by a liquid chromatography-electrospray tandem mass spectrometry (LC–ESI-MS/MS) method operated in single reaction monitoring (SRM). Validation was carried out in terms of limit of detection (LOD), limit of quantitation (LOQ), linearity, precision and trueness. LOD and LOQ values were fixed at 3 μg L?1 and 10 μg L?1, respectively, whereas linearity was established within 10–1,000 μg L?1 range for both compounds. Good precision was obtained for both eleutherosides in terms of intra-day precision (RSD % lower than 4 %) and inter-day precision (RSD % lower than 6 %). Good percentage recoveries were obtained for both eleutherosides (91.5–103.6 %). Finally, the developed method was successfully applied to analyze a number of solid and liquid commercial dietary supplements containing E. senticosus extracts, also mixed with other herbal extracts.  相似文献   

4.
A simple, sensitive and fast method for the determination of melamine and its derivatives in milk powder using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was developed. Neither time-consuming sample preparation, nor special target plates, or other extra equipment are necessary. The common matrix sinapinic acid (SA) was used with a dried-droplet preparation. Detection limits (signal-to-noise (S/N) ratio = 3) for standard solutions of melamine, ammeline and cyanuric acid were 10, 25 and 10 μg/L, respectively. The limit of quantification (LOQ) for melamine was 25 μg/L and excellent linearity (R(2): 0.9990) was maintained over the range of 10-2000 μg/L. Ammeline and cyanuric acid were analyzed with an LOQ of 50 μg/L and also excellent linearity (R(2): 0.9997 and R(2): 0.9998). Good accuracy and precision were obtained for all concentrations within the range of the standard curve. The developed method was successfully used for the determination of melamine, ammeline and cyanuric acid in milk powder samples with a simple sample preparation. The LOQ of melamine was 0.5 μg/g. Ammeline and cyanuric acid were detectable at 0.5 and 5 μg/g. This method showed excellent accuracy, precision and linearity and significantly reduces the needed analysis time, as only approximately 10 s/sample measuring time is required. To the authors' knowledge, this is the first published method to quantify melamine and derivatives by MALDI-TOF-MS.  相似文献   

5.
A new method is described for the qualitative and quantitative analysis of cyanide, a very short-acting and powerful toxic agent, in human whole blood. It involves the conversion of cyanide into hydrogen cyanide and its subsequent headspace solid-phase microextraction (HS-SPME) and detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode. Optimizing the conditions for the GC/MS (type of column, injection conditions, temperature program) and SPME (choice of SPME fiber, effect of salts, adsorption and desorption times, adsorption temperature) led to the choice of a 75-microm carboxen/polydimethylsiloxane SPME fiber, with D3-acetonitrile as internal standard, and a capillary GC column with a polar stationary phase. Method validation was carried out in terms of linearity, precision and accuracy in both aqueous solutions and blood. The limit of detection (LOD) and limit of quantitation (LOQ) were determined only in aqueous solutions. The assay is linear over three orders of magnitude (water 0.01-10, blood 0.05-10 microg/mL); and the LOD and LOQ in water were 0.006 and 0.01 microg/mL, respectively. Good intra- and inter-assay precision was obtained, always <8%. The method is simple, fast and sensitive enough for the rapid diagnosis of cyanide intoxication in clinical and forensic toxicology.  相似文献   

6.
A fast and reliable method for the determination of repaglinide is highly desirable to support formulation screening and quality control. A first-derivative UV spectroscopic method was developed for the determination of repaglinide in tablet dosage form and for dissolution testing. First-derivative UV absorbance was measured at 253 nm. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ) in comparison to the U.S. Pharmacopeia (USP) column high-performance liquid chromatographic (HPLC) method. The first-derivative UV spectrophotometric method showed excellent linearity [correlation coefficient (r) = 0.9999] in the concentration range of 1-35 microg/mL and precision (relative standard deviation < 1.5%). The LOD and LOQ were 0.23 and 0.72 microg/mL, respectively, and good recoveries were achieved (98-101.8%). Statistical comparison of results of the first-derivative UV spectrophotometric and the USP HPLC methods using the t-test showed that there was no significant difference between the 2 methods. Additionally, the method was successfully used for the dissolution test of repaglinide and was found to be reliable, simple, fast, and inexpensive.  相似文献   

7.
An efficient method for the simultaneous determination of methyl tert.-butyl ether, tert.-butyl alcohol, benzene, toluene, ethylbenzene and xylene isomers in groundwater by purge-and-trap-gas chromatography-mass spectrometry was developed and validated. Experimental design was used to investigate the effects of temperature of extraction, time of extraction and percentage of salt added to the water samples. Regression models and desirability functions were applied to find the experimental conditions providing the highest global extraction yield. Validation was carried out in terms of limits of detection (LOD), limits of quantitation (LOQ), linearity and precision. LOD values ranging from 2.6 to 23 ng l(-1) were achieved, whereas linearity was statistically verified over two orders of magnitude for each compound. Precision was evaluated testing two concentration levels. Good results were obtained both in terms of intra-day repeatability and intermediate precision: RSD% lower than 4.5% at the highest concentration and lower than 13% at the lowest one were calculated for intra-day repeatability. A groundwater sample suspected of contamination by leaking underground petroleum storage tanks was analysed and some of the analytes were detected and quantitated.  相似文献   

8.
A new method based on surface-enhanced Raman spectroscopy (SERS) has been developed for sensitive and rapid detection of melamine. Spherical magnetic-core gold-shell nanoparticles (AuNPs) and rod-shaped gold nanoparticles (nanorods) labeled with a Raman-active compound were used to form a complex with the melamine molecules. 5,5'-Dithiobis(2-nitrobenzoic acid) was used as Raman-active compound because it is readily adsorbed by a gold nanoparticle surface forming a self-assembled monolayer (SAM) and has strong Raman scattering at 1330 cm(-1), because of the symmetric NO(2) stretch. The calibration curve was obtained by plotting Raman band area at 1330 cm(-1) against melamine concentration. A linear relationship was obtained with a high determination coefficient (R(2)=0.997). The method was validated for linearity, sensitivity, precision (intra-day and inter-day repeatability), and recovery. In the model system, the limits of detection (LOD) and quantification (LOQ) were 0.38 and 1.27 mg L(-1), respectively. For melamine-spiked milk samples, LOD and LOQ values were 0.39 mg L(-1) and 1.30 mg L(-1), respectively. Intra and inter-day precision were 3.73 and 4.94 %, respectively. This method was applied to samples of skimmed milk that had been spiked with melamine at different concentrations. The recovery of the method was 95-109 % in the concentration range 2-15 mg L(-1), and average RSD was 1.71 %. Total analysis time was less than 15 min.  相似文献   

9.
The analysis of the acaricide fenbutatin oxide (FBTO) having a molecular weight of 1052.66 g mol(-1) in water samples by capillary GC/MS after in-situ derivatization with sodium tetraethylborate (NaBEt4) and headspace-SPME enrichment is described. Automated SPME is performed at 80 degrees C for 30 min. Detection is carried out in the ion monitoring mode with deuterated triphenyltin (TPhTd15) as internal standard. Good linearity (R2 = 0.9993) was obtained in the dynamic range 20 to 1000 ng L(-1) with a limit of detection of 16 ng L(1) (LOD at 3 S/N) and a limit of quantitation of 50 ng L(-1) (LOQ at 10 S/N). Intra-day RSD% for n=6 was 8.9 at the LOQ level.  相似文献   

10.
A hydride generation flame atomic absorption spectrometric method was developed and optimized to quantitate arsenic (As) in foods. A wet digestion of the samples with HNO3 + H2O2 was performed and excess oxidants were eliminated by addition of hydrochloric acid and urea. As5+ in As3+ was then reduced by potassium iodide. The As3+ solution was analyzed by generation of arsine with sodium tetrahydroborate. As determination ranged from 2.5 to 20 microg/L, with a determination coefficient of 0.997. The limits of detection (LOD) and quantitation (LOQ) were 0.6 and 2.1 microg/L, respectively. The method was validated and good results were obtained for recovery, precision, accuracy, LOD, and LOQ. This method is now used to analyze foods from Rwanda.  相似文献   

11.
An accurate method based on the use of reversed-phase (RP) liquid chromatography-tandem mass spectrometry interfaced with electrospray (LC-ESI-MS/MS) was devised for the determination of Sudan I, Sudan II, Sudan III and Sudan IV in hot chilli food samples. A simple sample treatment procedure entailing the use of an extraction step with acetone without clean-up was developed. A C18 column with an aqueous formic acid/methanol mixture as the mobile phase was used under isocratic conditions. Mass spectral acquisition was done in positive ion mode by applying selected reaction monitoring of three fragmentation transitions per compound to provide a high degree of selectivity. The method was in-house validated in terms of detection limits (LOD), quantitation limits (LOQ), linearity, sensitivity, accuracy, recovery, and selectivity on two kinds of hot chilli sauces. Good results in the low ng/g level were obtained for LOD and LOQ of all analytes in matrices. Under both intra-day repeatability (R.S.D. between 1 and 13%) and intermediate precision (about 5-15% R.S.D. for both chilli sauce matrices) conditions, precision proved to be typical of determinations based on electrospray LC-MS and acceptable for routine monitoring purposes. Extraction recoveries for all four azo-dyes in chilli tomato sauce ranged from 92 to 103% at a spiking level of 5 microg/kg, whereas values between 72 and 97% were calculated in chilli tomato and cheese sauce at the same concentration level. The applicability of the method to the determination of Sudan azo-dyes in hot chilli products was demonstrated.  相似文献   

12.
A column high-performance liquid chromatography (HPLC) method was developed for the determination of glucosamine in dosage forms. Glucosamine was derivatized by addition of a solution containing orthophthaldialdehyde. The HPLC separation was achieved on a Spherimage 80 ODS2 column (250 x 4 mm id, 5 microm particle size) using an isocratic mobile phase containing phosphate buffer-methanol (90 + 10, v/v, pH 6.50) and methanol-tetrahydrofuran (97 + 3, v/v) in proportions of 85 + 15 at a flow rate of 1 mL/min, followed by fluorescence detection. The method was validated for specificity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). The detector response for glucosamine HCI was linear over the concentration range of 0.1-20 microg/mL with a correlation coefficient of 0.9980. The accuracy was between 99.4 and 100.8%. The LOD and the LOQ were 0.009 and 0.027 microg/mL, respectively. The method was applied to determination of glucosamine in solid dosage forms.  相似文献   

13.
An ultraviolet spectrophotometric method was validated for total flavonoid quantitation, as rutin equivalents, present in the Trichilia catigua Adr. Juss (Meliaceae) and Ptychopetalum olacoides Bentham (Olacaceae) commercial extract. Parameters as linearity, interval (range), specificity, estimated limit of detection (LOD, microg/mL), estimated limit of quantitation (LOQ, microg/mL), recovery (R, %), precision or relative standard deviation (RSD, %), and accuracy (E, %) were established. The analytical method was validated according to the experimental results: correlation coefficient (r = 0.9997); interval (RSD = 0.15-0.47%; E = 98.98-101.24%); specificity to total flavonoids quantitation, as rutin equivalents, at wavelength 361.0 nm; LOD = 0.09 microg/mL and LOQ = 0.27 microg/mL; R = 99.36-102.14%; adequate intra- and interrun precision (0.30-0.49% and 0.31-0.81%), and intra- and interrun accuracy (100.60-102.38% and 98.58-100.38%).  相似文献   

14.
Bioremediation of toluene and naphthalene in liquid cultures of bacteria grown in the presence of these aromatic compounds as unique sources of carbon was investigated by gas chromatography (GC). For this purpose, a method based on the use of GC with flame ionization detection was developed and validated. Validation was carried out in terms of limit of detection (LOD), limit of quantitation (LOQ), linearity, precision and trueness. In the case of naphthalene, LOD and LOQ values of 0.43 and 0.72 mg kg(-1) were achieved. Linearity was established over one order of magnitude in the range of interest, i.e. 10-100 mg kg(-1). Excellent precision was obtained both in terms of intra-day repeatability and between-day precision on two concentration levels (RSD% lower than 0.5%). A recovery of 97.9 +/- 0.2% (n=3) was calculated by addition of 640 mg kg(-1) of naphthalene to the Bushnell & Haas mineral salts basal solution containing the micro-organisms. Findings clearly showed a reduction of the naphthalene content equal to 50% and 75% after two and four weeks of contact with the micro-organisms, whereas a lower degradation was shown in the case of toluene. Finally bioremediation activity was ascribed to two different microbial populations, Bordetella Petrii and Bacillus Sphericus, which survived in the polluted medium.  相似文献   

15.
A rapid method has been devised for the direct determination of chlormequat in tomato samples. No clean-up is required, and analysis uses ion-exchange liquid chromatography/tandem mass spectrometry interfaced with electrospray ionization (LC/ESI-MS/MS). A cation-exchange column was used with an aqueous ammonium acetate/acetonitrile mixture as the mobile phase under isocratic conditions. The method was validated in terms of detection limits (LOD), quantitation limits (LOQ), linearity, recovery, precision and accuracy. Good results in the low micro g kg(-1) level were obtained for the LOD and LOQ of chlormequat in tomato samples. Comparison of solvent and matrix-matched calibration curves demonstrated the absence of significant matrix effects and the feasibility of using external calibration. Linearity was established over two orders of magnitude by performing homoscedasticity and Mandel fitting statistical tests. The absence of both constant and proportional systematic errors was verified by evaluating the recovery function, demonstrating good method accuracy. Excellent precision in terms of intra-day repeatability was calculated (RSD% <3.4). Extraction recoveries from tomato products were calculated, by using a labelled internal standard (d(4)-chlormequat), to be in the 93 +/- 5-99 +/- 7% range. The applicability of the method to the determination of chlormequat residues in tomato products was demonstrated.  相似文献   

16.
A microemulsion electrokinetic chromatography (MEEKC) method has been developed and validated for the determination of folic acid, a water-soluble vitamin, in a commercial tablet formulation. The analysis was performed using a microemulsion containing 0.5% (w/w) ethyl acetate, 1.2% (w/w) butan-1-ol, 0.6% (w/w) sodium dodecyl sulfate, 15% (v/v) 2-propanol and 82.7% (w/w) 10 mmol L(-1) sodium tetraborate aqueous buffer at pH 9.2. Direct UV detection at 214nm led to an adequate sensitivity without interference from sample excipients. For quantitative purposes, niacin was used as internal standard. Acceptable precision (<1.2% relative standard deviation (R.S.D.)), linearity (r = 0.9992; range from 160.0 to 240.0 microg/mL), sensitivity (limit of detection (LOD) = 2.98 microg/mL; limit of quantification (LOQ) = 9.05 microg/mL) and recovery (99.8 +/- 1.8% at three concentration levels) were obtained. Based on the performance characteristics, the proposed methodology was found suitable for the determination of folic acid in tablet formulations.  相似文献   

17.
A rapid, simple, and sensitive RP-HPLC analytical method was developed for the simultaneous determination of triclabendazole and ivermectin in combination using a C18 RP column. The mobile phase was acetonitrile-methanol-water-acetic acid (56 + 36 + 7.5 + 0.5, v/v/v/v) at a pH of 4.35 and flow rate of 1.0 mL/min. A 245 nm UV detection wavelength was used. Complete validation, including linearity, accuracy, recovery, LOD, LOQ, precision, robustness, stability, and peak purity, was performed. The calibration curve was linear over the range 50.09-150.26 microg/mL for triclabendazole with r = 0.9999 and 27.01-81.02 microg/mL for ivermectin with r = 0.9999. Calculated LOD and LOQ for triclabendazole were 0.03 and 0.08 microg/mL, respectively, and for ivermectin 0.07 and 0.20 microg/mL, respectively. The intraday precision obtained was 98.71% with RSD of 0.87% for triclabendazole and 100.79% with RSD 0.73% for ivermectin. The interday precision obtained was 99.51% with RSD of 0.35% for triclabendazole and 100.55% with RSD of 0.59% for ivermectin. Robustness was also studied, and there was no significant variation of the system suitability of the analytical method with small changes in experimental parameters.  相似文献   

18.
建立了牛奶和奶粉中三聚氰酸(CYA)的高效液相色谱-串联质谱(HPLC-MS/MS)测定方法。样品用乙腈提取并沉淀蛋白,经强阴离子交换柱富集和净化,AX色谱柱分离,HPLC-MS/MS法测定,内标法定量。50~2000 μg/L范围内CYA的线性关系良好(r≥0.999);在奶粉和牛奶基质中,添加200、500和1000 μg/kg 3个添加水平的回收率均在97%~121%之间,相对标准偏差(RSD)均小于4.8%;定量限(LOQ)为200 μg/kg。方法的前处理快速简便,净化效果好,准确度和精密度高,可用于牛奶和奶粉中CYA的测定。  相似文献   

19.
In this study, the development and validation of an analytical method for the assay of 4,7-phenanthroline-5,6-dione I (dione I) using high-performance liquid chromatography (HPLC) and the determination of its synthetic impurities by employing the method in HPLC-mass spectrometry with atmospheric-pressure chemical ionization and photodiode-array UV detection is reported. The results show that dione I is eluted as a spectrally pure peak resolved from its impurities. 5-Bromo,4-7-phenanthroline is identified as the main impurity. This is supported by elemental analysis of the dione I, which demonstrated the presence of bromine. Validation parameters such as specificity and selectivity, linearity, accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ), ruggedness, stability, and system suitability, which are evaluated for this method. The LOD and LOQ are 2.0 microg/mL and 50 microg/mL with a 0.50% relative standard deviation (%RSD), respectively. The calibration curves showed good linearity over the concentration range of 0.05-1.50 mg/mL. The correlation coefficient is > 0.9991 in each case. The %RSD values for intra- and interday precision studies are < 0.40%.  相似文献   

20.
A new and accurate HPLC method using sulfobutylether-beta-cyclodextrin (SBE-beta-CD) as chiral mobile phase additive (CMPA) was developed and validated for the determination of R-(+)pantoprazole in S-(-)pantoprazole. The influences of type and concentration of CD, ACN content and buffer pH of mobile phase on the resolution and retention of enantiomers were investigated. A baseline resolution of pantoprazole enantiomers was achieved on a Spherigel C18 column (150 mm x 4.6 mm, 5 microm) using ACN and 10 mM phosphate buffer (pH 2.5) containing 10 mM SBE-beta-CD (15:85 v/v) as mobile phase with a flow rate of 0.9 mL/min at 20 degrees C. The detection wavelength was set at 290 nm. The method was extensively validated in terms of accuracy, precision and linearity according to the International Conference on Harmonisation (ICH) guidelines and proved to be robust. The LOD and LOQ for R-(+)pantoprazole were 0.2 and 0.5 microg/mL, respectively, with 5 microL injection volume. A good linear relationship was obtained in the concentration range of 0.5-6.0 microg/mL with r(2) >0.999 for R-(+)pantoprazole. The percentage recovery of the R-(+)pantoprazole ranged from 92.1 to 101.2 in bulk drug of S-(-)pantoprazole. The method is capable of determining a minimum limit of 0.05% w/w of R-enantiomer in S-(-)pantoprazole bulk samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号