首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 796 毫秒
1.
A simple, sensitive and rapid HPLC method was developed and validated for the simultaneous determination of famotidine (FMT) and related impurities in pharmaceuticals. Chromatographic separation was accomplished within 10 min on a porous graphitic carbon (PGC) column using 50:50 v/v ACN-water containing 0.5% pentane sulphonic acid (PSA) as the mobile phase. Separation was achieved with a flow rate of 1 mL/min and a detection wavelength of 265 nm. The calibration curves were linear over a concentration range of 1.5-100 microg/mL. The intra- and interday RSDs (n = 5) for the retention times and peak area were all less than 2%. The method was sensitive with an LOD (S/N = 3) of 0.1 microg/mL for FMT, imp. C and 0.05 microg/mL for imp. 2, A and D. All recoveries were greater than 98%. The method was demonstrated to be precise, accurate and specific with no interference from the tablet ingredients and separation of the drug peak from the peaks of the degradation products (oxidative degradation and acid and base degradation). The results indicated that the proposed method could be used for the determination of FMT in commercial dosage forms and as a stability-indicating assay.  相似文献   

2.
S M Wu  Y H Ho  H L Wu  S H Chen  H S Ko 《Electrophoresis》2001,22(13):2717-2722
In this study, low concentrations of histamine2-receptor (H2-)antagonists were effected across a water plug, with separation taking place in a binary buffer comprising ethylene glycol and NaH2PO4 (pH 5.0), and detection at 214 nm. Liquid-liquid extraction with ethyl acetate- isopropanol is shown to provide extracts that are sufficiently clean. The calibration curves were linear over a concentration range of 0.1-2.00 microg/mL cimetidine, 0.2-5.0 microg/mL ranitidine-HCl, 0.3-5.0 microg/mL nizatidine, and 0.1-3.0 microg/mL famotidine. Mean recoveries were > 82%, while the intra- and interday relative standard deviations (RSDs) and relative errors (REs) were all < 13%. The method is sensitive with a detection limit of 3 ng/mL cimetidine, 30 ng/mL ranitidine HCl, 50 ng/mL nizatidine and 10 ng/mL famotidine (S/N = 3, electric-driven injection 90 s). This newly developed capillary electrophoresis (CE) method was applied for the determination of analytes extracted from plasma taken from a volunteer dosing a cimetidine, ranitidine, and nizatidine tablet simultaneously. These three H2-antagonists can be detected in real samples by this method, excluding the low dosing of famotidine tablet.  相似文献   

3.
A capillary electrophoresis coupling with indirect chemiluminescence detection method for the simultaneous determination of benserazide and levodopa has been developed. The detection interface was improved to simplify the capillary electrophoresis-chemiluminescence (CE-CL) system and the features of this improved interface were illustrated in this paper. The CE-CL conditions for the simultaneous determination of benserazide and levodopa were optimized. Under the optimal conditions, the CL intensity was linear with concentrations of levodopa in the range of 1.0 to 100.0 microg ml(-1), and benserazide in the range of 10.0 to 1,000 microg ml(-1), respectively. The detection limits (S/N=3) in turn were 1.85 microg ml(-1) for BS and 0.12 microg ml(-1) for L-dopa with relative standard deviations of less than 3%. The proposed method has been successfully applied to the determination of benserazide and levodopa in medopar tablets and spiked urine samples, demonstrating the feasibility and reliability of the proposed method.  相似文献   

4.
A fast and highly selective micellar electrokinetic capillary chromatography (MEKC) method for quantitative analysis of vancomycin and related impurities is described. Among the tested surfactants, cetyltrimethylammonium chloride (CTAC) offered the best selectivity. Another important parameter, which strongly influenced the selectivity, was buffer pH. It was found that the selectivity increased with buffer pH decreasing from 9 to 5. Using Tris-phosphate buffer containing CTAC, satisfactory separation could be obtained in the pH range from 5.0 to 5.5. Excellent repeatability in terms of migration time and peak area could be obtained when the capillary was carefully washed between two runs. In order to obtain optimal conditions and to evaluate the method robustness, a central composite experimental design was carried out. The optimal conditions were: 44 cm length of fused-silica capillary with 50 microm ID, 120 mM Tris-phosphate buffer (pH 5.2) containing 50 mM CTAC, -15 kV applied voltage, UV detection at 210 nm, and a column temperature of 25 degrees C. Under the optimal conditions, more than 20 peaks could be separated within 8 min. The method has a linearity range from 0.004 to 1.2 mg/ml (concentration of vancomycin B, active component). The limit of detection (LOD) and limit of quantitation (LOQ) were 0.4 microg/mL vancomycin, equivalent to 0.3 microg/mL vancomycin B (0.04%) and 1.1 microg/mL vancomycin, equivalent to 0.9 microg/mL vancomycin B (0.1%), respectively.  相似文献   

5.
Song J  Liu H  Han P  Zhao C  Wu Y  Zhang S 《Electrophoresis》2006,27(22):4480-4486
A practical NACE method was developed for simultaneous determination of three adenosine monophosphate (AMP) isomers. Separation of three AMP isomers was achieved using 200 mM Tris/H(3)BO(3) in acetontrile/water (2:1 v/v) at pH* 10.0 as the running buffer and +25 kV as the applied voltage over a bare fused-silica capillary of 50 microm id x 375 microm od x 54.5 cm (46 cm to the detector window). At 260 nm, the calibration curves were linear in the range of 1-100 microg/mL. The detection limits were less than 0.70 microg/mL. The recovery ranged from 94.5 to 106.4%. The intraday RSDs of the migration times were between 2.1 and 3.0%. The developed NACE method has been successfully applied for the determination of three AMP isomers in the real samples of biomimicking prebiotic synthesis reaction between N-(O,O-diisopropyl) phosphoryl amino acid and adenosine.  相似文献   

6.
A simple kinetic spectrophotometric method is described for the determination of famotidine. The method is based on the oxidation of the drug with alkaline potassium permanganate. The reaction is followed spectrometrically by measuring the rate of change of the absorbance at 610 nm. The initial-rate and fixed-time (at 12 min) methods are adopted for determining the drug concentration. The calibration graphs are linear in the ranges of 2-10 microg mL(-1) and 1-8 microg mL(-1) using the initial-rate and fixed-time methods, respectively. The method has been applied to the determination of famotidine in tablet formulations. The obtained results are compared statistically with those given by a reference spectrophotometric method.  相似文献   

7.
A selective stability-indicating HPLC-UV method for simultaneous determination of glipizide and four impurities (DPs I-IV) formed under hydrolytic conditions was developed and validated. The drug and impurities were resolved on an XTerra C18 column (250 x 4.5 mm id) in a single gradient run using buffer (0.005 M KH2PO4; pH 3.0)-methanol (60 + 40, v/v; mobile phase A) and (20 + 80, v/v; mobile phase B) at a flow rate of 0.5 mL/min with 230 nm detection wavelength. The method was linear across concentration ranges of 0.2-100, 0.1-100, 0.5-100, 0.2-100, and 0.1-50 microg/mL for glipizide and DPs I-IV, respectively. The RSD for intraday and interday precision for the drug and impurities was < 1 and < 1.2%, respectively. Satisfactory recoveries (96.58-99.97%) of each of the three concentrations selected across the linearity range of each analyte were obtained, proving the method was sufficiently accurate. The LOD was 0.07, 0.05, 0.16, 0.08, and 0.05 microg/mL and the LOQ was 0.20, 0.14, 0.50, 0.23, and 0.14 microg/mL for the drug and DPs I-IV, respectively. Each peak was resolved with resolution of > 2 from the nearest peak. Insignificant changes in retention time (< 4%) and calculated amount (< 1.65%) of drug and each impurity upon small but deliberate changes in various chromatographic parameters were observed, suggesting the method was robust. The method was applied successfully to stability testing of glipizide tablets.  相似文献   

8.
Fang C  Wan X  Tan H  Jiang C 《Annali di chimica》2006,96(1-2):117-124
Pueraria lobata is a rich source of isoflavonoids. The detection and identification of isoflavonoid components from root, stem, leaf, callus and cell samples, is very important for the best, safest and most efficacious use of kudzu as a medicinal plant, and for the studies on quantitative analysis in the secondary metabolism of isoflavonoids. In this paper, a simple, rapid and precise high-performance capillary electrophoresis (HPCE) method with diode array detection (DAD) has been developed for separation and determination of isoflavonoids in several kudzu samples. The isoflavonoids could be well separated within 15 min in a 40 cm length capillary at a separation voltage of 15kV in a 30 mmol L(-1) borax buffer (pH9.29), and this proposed method demonstrated excellent reproducibility and accuracy with relative standard deviations of less than 5% for isoflavonoid content (n = 5) of different kudzu samples. The relationship between peak areas and isoflavone concentrations, in a specified working range with linear response, was determined by first-order polynomial regression over the range 0.05-0.5 mg mL(-1) for puerarin and 2.5-50 microg mL(-1) for 3'-methoxypuerarin, daidzin and daidzein, respectively, and quantitative evaluation of those four main isoflavonoid components was determined by ultraviolet absorption at lambda = 192 nm. The differences were also illustrated by comparison of the determination of isoflavonoid components from kudzu root, stem, leaf samples and plant tissue cultures in vitro.  相似文献   

9.
A novel capillary zone electrophoresis method is described for the determination of taurine in plasma. The method is rapidly executed and is highly selective for taurine as separation is based on the difference in ionisation of this amino acid from that of other amino acids. Following addition of homotaurine as internal standard, plasma proteins were precipitated with acetonitrile and the supernatant was derivatised with fluorescamine in the presence of a borate buffer. Capillary electrophoresis (CE) separations were carried out in reverse polarity mode at 27.5 kV on a Beckman P/ACE MDQ CE instrument, equipped with a diode array detector (DAD) set at 266 nm. The sample tray was cooled to 5 degrees C and separations were carried out at 20 degrees C. The fused-silica capillary was 50.2 cm in length (40.2 cm to detector) with an internal diameter of 75 microm. A capillary conditioning solution was applied daily in order to suppress the residual electroosmotic flow (EOF). The method, which was validated using feline plasma as the blank matrix, was shown to be linear and reproducible over the concentration range 2.5-100 microg/mL. The coefficients of variation (CVs) of replicate analyses were less than 4.5% at 1 microg/mL taurine in feline plasma and less than 3% for 2.5 microg/mL in human plasma. Recovery was estimated at 99.2% with a CV of 4.85%. It has been demonstrated that quantitation in aqueous solution yields similar results to those obtained by interpolation on a plasma calibration curve provided that subtraction for the taurine peak in unspiked plasma is carried out and that a suitable internal standard is employed.  相似文献   

10.
A rapid, accurate and reliable analytical method was developed for the simultaneous determination of five major anthraquinones, aloe-emodin, chrysophanol, emodin, physcion, and rhein, in radix Polygoni multiflori, a traditional Chinese herbal medicine. The method comprises a fast ultrasonic extraction with methanol and derivatization with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA)+1% trimethylchlorosilane (TMCS) followed by capillary gas chromatographic (GC) separation. The effect of reaction time on the derivatization of anthraquinones was examined. A baseline separation of the anthraquinone and internal standard derivatives was achieved in 15min. The detection limits range from 0.22 to 0.60microg/mL for the five anthraquinones. The calibration curves are linear over the concentration range studied (from the detection limits to 40.0microg/mL) with the squares of correlation coefficients, R2, greater than 0.998. The developed method was successfully applied to the simultaneous determination of anthraquinones in radix P. multiflori samples. The peak identification was confirmed using GC-MS. The contents of anthraquinones in radix P. multiflori samples studied were 27.41, 289.6, 64.22, 202.1, 288.6microg/g for chrysophanol, emodin, aloe-emodin, physcion, rhein, respectively. All relative standard deviations are less than 3.2%. The recoveries range from 80.2% to 119.3% for the five analytes. To the authors' best knowledge, this is the first GC method reported for the simultaneous determination of the five anthraquinones in radix P. multiflori.  相似文献   

11.
A capillary electrophoresis/mass spectrometry method for the simultaneous chiral analysis of enantiomers of methamphetamine (MA), amphetamine (AP), dimethylamphetamine (DMA), ephedrine (EP), norephedrine (NE) and methylephedrine (ME) in urine has been developed. The background electrolyte was 1 M formic acid (pH 1.7). Using 0.85 mM heptakis(2,6-diacethyl-6-sulfato)-beta-cyclodextrin as the chiral selector, the 12 enantiomers were completely separated within 25 min. The detection limits were 0.01 microg mL(-1) for the enantiomers of MA, AP, DMA, EP and ME, and 0.02 microg mL(-1) for the enantiomers of NE using selected ion monitoring. The reproducibilities of within-run (n = 4) for the migration times and peak areas of the standard mixture were under 0.58% and 7.83%, respectively. The calibration curves of the peak areas of the 12 enantiomers were linear in the range of 0.05 - 10 microg mL(-1). This method was applicable to the analysis of urine samples.  相似文献   

12.
A simple, rapid and accurate method for the simultaneous determination of four purine and pyrimidine bases (cytosine, 5-methylcytosine, adenine and N6-methyladenine) has been developed. The quantitative determination of these bases was accomplished by ion chromatography (IC) with direct conductivity detection (CD) based on their ionization in acidic medium without chemical suppression. The recovery of cytosine, 5-methylcytosine, and adenine in calf thymus DNA was more than 98% (n=3) and the relative standard deviation (RSD, n=5) less than 2.4%. In a single chromatographic run, the four bases could be separated and determined in less than 10 min. The detection limits were found to be 0.05 microg/mL for cytosine, 0.08 microg/mL for 5-methylcytosine, 0.07 microg/mL for adenine, and 0.07 microg/mL for N6-methyladenine. Linear ranges were 0.2-95.1 microg/mL for cytosine (r2=0.9996), 0.3-196.6 microg/mL for 5-methylcytosine (r2=0.9994), 0.3-105.5 microg/mL for adenine (r2=0.9998), and 0.3-159.1 microg/mL for N6-methyladenine (r2=0.9999). With the proposed method, purine and pyrimidine bases could be successfully detected in calf thymus DNA. We also determined these bases in calf thymus DNA using RP-HPLC. Compared to RP-HPLC, the IC method offers advantages such as high selectivity and simple mobile phase.  相似文献   

13.
The adsorptive and electrochemical behaviors of azithromycin were investigated on a glassy carbon electrode that was electrochemically treated by anodic oxidation at +1.8 V, following potential cycling in the potential range from -0.8 to +1.0 V. The resulting electrode showed good activity to improve the electrochemical response of the drug. An adsorptive stripping voltammetric method for the determination of azithromycin at an electrochemically activated glassy carbon electrode has been developed. Azithromycin was accumulated in phosphate buffer, pH 6, at a potential of +0.3 V (vs. Ag/AgCl electrode) for a certain time, and then determined by differential pulse voltammetry. The oxidative peak current at +0.82 V, at a scan rate of 20 mV s(-1), was a linear function of the concentration in the ranges of 0.25 - 2 microg mL(-1) and 1 - 10 microg mL(-1) using a 240 or 60 s(-1) preconcentration time, respectively. Application of the method to the determination of azithromycin in pharmaceuticals resulted in an acceptable deviation from the stated concentration. The preconcentration medium-exchange approach was utilized for the selective determination of the drug in spiked urine samples with satisfactory results. The peak current was linear with the drug concentration in the range of 0.5 - 3.5 microg per mL urine. The detection limit was 0.2 microg mL(-1) urine. The recovery levels of the method reached 96.3%.  相似文献   

14.
This article explores the use of capillary electrochromatography for the analysis of chamomile (Chamomilla recutita L.) extracts. After a thorough study of analytical parameters such as mobile and stationary phase composition, applied voltage, and temperature, a methodology to determine 11 bioactive phenolic compounds (coumarins: herniarin, umbelliferone; phenylpropanoids: chlorogenic acid, caffeic acid; flavones: apigenin, apigenin-7-O-glucoside, luteolin, luteolin-7-O-glucoside; flavonols: quercetin, rutin and flavanone: naringenin) in chamomile extracts was proposed. The method was performed in a Hypersil SCX/C18 column with pH 2.8 phosphate buffer at 50 mmol L(-1) containing 50% acetonitrile (pH adjusted before the addition of the organic solvent). All compounds were separated in less than 7.5 min under isocratic conditions. Figures of merit include linearity (peak area versus apigenin concentration) from 50.0-1000 microg/mL (r2=0.995), and intra-day precision of retention time and peak area better than 1.3% CV and 15%, respectively. The limits of detection and quantification for apigenin were 35.0 microg/mL and 150.0 microg/mL, respectively. This article also describes an NMR 1H study, carried out to monitor a new clean-up procedure for extracts containing propyleneglycol, whose components are poorly retained in conventional octadecyl silica cartridges.  相似文献   

15.
In this study, the development and validation of an analytical method for the assay of 4,7-phenanthroline-5,6-dione I (dione I) using high-performance liquid chromatography (HPLC) and the determination of its synthetic impurities by employing the method in HPLC-mass spectrometry with atmospheric-pressure chemical ionization and photodiode-array UV detection is reported. The results show that dione I is eluted as a spectrally pure peak resolved from its impurities. 5-Bromo,4-7-phenanthroline is identified as the main impurity. This is supported by elemental analysis of the dione I, which demonstrated the presence of bromine. Validation parameters such as specificity and selectivity, linearity, accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ), ruggedness, stability, and system suitability, which are evaluated for this method. The LOD and LOQ are 2.0 microg/mL and 50 microg/mL with a 0.50% relative standard deviation (%RSD), respectively. The calibration curves showed good linearity over the concentration range of 0.05-1.50 mg/mL. The correlation coefficient is > 0.9991 in each case. The %RSD values for intra- and interday precision studies are < 0.40%.  相似文献   

16.
A simple, fast, inexpensive and reliable capillary zone electrophoresis (CZE) method for the determination of econazole nitrate in cream formulations has been developed and validated. Optimum conditions comprised a pH 2.5 phosphate buffer at 20 mmol L(-1) concentration, +30 kV applied voltage in a 31.5 cm x 50 microm I.D. capillary. Direct UV detection at 200 nm led to an adequate sensitivity without interference from sample excipients. A single extraction step of the cream sample in hydrochloric acid was performed prior to injection. Imidazole (100 microg mL(-1)) was used as internal standard. Econazole nitrate migrates in approximately 1.2 min. The analytical curve presented a coefficient of correlation of 0.9995. Detection and quantitation limits were 1.85 and 5.62 microg mL(-1), respectively. Excellent accuracy and precision were obtained. Recoveries varied from 98.1 to 102.5% and intra- and inter-day precisions, calculated as relative standard deviation (RSD), were better than 2.0%. The proposed CZE method presented advantageous performance characteristics and it can be considered suitable for the quality control of econazole nitrate cream formulations.  相似文献   

17.
研究了离子色谱-直接电导检测法分离测定离子液体中的卤素离子(F~-、Cl~-、Br~-)杂质.采用Shim-pack IC-A3阴离子交换色谱柱,考察了淋洗液种类及浓度、流速和色谱柱温度对分离测定的影响.最佳色谱条件为:以1.25 mmol/L邻苯二甲酸氢钾为淋洗液,流速1.5 mL/min,色谱柱温45 ℃.在此条件下可以基线分离卤素离子,且NO~-_3、BF~-_4、SO~(2-)_4不干扰测定.该法测定卤素离子的检出限(S/N=3)为0.02 ~0.11 mg/L,峰面积的相对标准偏差(n=5)不大于0.7%,F~-、Cl~- 和Br~- 的标准曲线的线性范围分别为0.1 ~50、0.1 ~50、0.5 ~100 mg/L.将方法用于烷基咪唑四氟硼酸盐离子液体中卤素离子杂质的测定,加标回收率为98% ~102%.  相似文献   

18.
A new micelle capillary electrophoresis based on cyclodextrin micellar electrokinetic chromatography (MEKC) for the determination of bisphenol A and 10 alkylphenols in rat serum is reported. Several surfactants and dextrins were studied. Bisphenol A and alkylphenols were separated using a 50 microm x 50 cm capillary with 20 mM borate phosphate buffer (pH 8.0) containing 20 mM sodium dodecylsulfate and 5 mM gamma-cyclodextrin as carrier. The method could determine 0.6-2000 microg/mL of phenols in 100 microL serum by photometric detection at 214 nm. Using 2.0 mL serum, 1.0 ng/mL of phenols could be determined. The relative standards deviations were 6.3-7.7% at 10 microg/mL in serum. The recoveries were 91.8-93.0% with 10 microg/mL serum samples.  相似文献   

19.
A simple, fast, inexpensive capillary zone electrophoresis method for the separation and determination of tiapride hydrochloride and its two related impurities in pharmaceutical formulations has been developed and validated. The successful separation of these compounds was achieved in less than 3 min using a fused silica capillary and photodiode array detector at 218 nm. The best conditions were obtained using a 10 mM sodium tetraborate (pH 8.0) as the running buffer. The linear responses covered the ranges from 1.0 to 100 μg mL?1 (R = 0.9989) for tiapride hydrochloride. The detection (LOD) and quantitation limits (LOQ) for tiapride hydrochloride were 2.7 and 9.0 μg mL?1, respectively. The intra- and inter-day relative standard deviations for migration times and peak areas were less than 0.47 and 5.7%, respectively. The method was validated for the determination of tiapride hydrochloride in commercial tablets.  相似文献   

20.
A method for the determination of cyclamate in food was developed using solid-phase extraction (SPE) and capillary electrophoresis (CE) with indirect ultraviolet (UV) detection. A 5-10 g sample in 0.1 mol/L hydrochloric acid was homogenized and made up to a volume of 50 mL with 0.1 mol/L hydrochloric acid. After the sample was centrifuged, 25 mL of supernatant was loaded into an Oasis HLB SPE cartridge. The cartridge was washed with 2 mL of demineralized water followed by 2 mL of 50% aqueous methanol, and cyclamate was eluted with 4.5 mL of 50% aqueous methanol. The eluate was added to a solution of sodium propionate (internal standard) for CE analysis. The cyclamate in the eluate was electrophoresed on a fused-silica capillary using 1 mmol/L hexadecyltrimethylammonium bromide and 10 mmol/L potassium sorbate as a running buffer. Detection and reference wavelengths of cyclamate determined with a UV detector were 300 and 254 nm, respectively. The calibration curves for cyclamate showed good linearity in the range of 2-1000 microg/mL and the limits of detection in beverage, fruit in syrup, jam, pickles and confectionary are sample dependent and ranged from 5-10 microg/g. The recovery of cyclamate added at a level of 200 microg/g to various kinds of foods was 93.3-108.3% and the relative standard deviation was less than 4.9% (n=3). A number of commercial samples were analyzed using the proposed method. Cyclamate was detected in one waume, two pickles, and two sunflower seeds. The quantitative values determined with CE correlated to those from high-performance liquid chromatography (HPLC) (the detected values of cyclamate in a sunflower seed measured by CE and HPLC were 3.40 g/kg and 3.51 g/kg, respectively). This analytical method for cyclamate using CE is especially suitable for use in the field.  相似文献   