1.
The analytical performances of three atmospheric-pressure sources, electrospray (ESI), atmospheric-pressure chemical ionization (APCI), and atmospheric-pressure photoionization (APPI), were evaluated for the analysis of pentacyclic triterpenes in liquid chromatography-mass spectrometry (LC-MS). Among these sources, APPI and APCI are particularly well adapted to sensitive analyses of pentacyclic triterpenes by LC-MS. Detection parameters were optimized for both the sources, and the effects of three dopants (toluene, acetone and anisole) on the detection (sensitivity and ion fingerprints in MS spectra) were studied in detail for APPI-MS.The limits of quantification were measured under selected ion monitoring conditions, in the range of 0.005-0.015 mg l(-1) and 0.002-0.84 mg l(-1) in APPI and APCI, respectively, depending on the studied pentacyclic triterpene. Overall, APPI was found more sensitive than APCI in positive ion mode, whereas APCI shows the greatest sensitivity for acidic triterpenes in negative ion mode.Following this study, the developed LC-MS method was used for the characterization of pentacyclic triterpenes in three plant extracts. High amounts of betulinic acid, betulinic aldehyde and betulinic aldehyde acetate were observed in plane bark. The main component of birch bark is betulin and extracts of okoume resin exhibit high amounts of alpha- and beta-amyrin.  相似文献   

2.
In this work, ten selected pesticides of different chemical groups, indicated to orange culture, were extracted and determined by liquid chromatography-mass spectrometry using both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) operating in the positive ion detection mode. Applying a variables selection technique verified that cone voltage, source temperature and drying-gas flow-rate are the critical variables when the ESI was used, while cone voltage was found to be the only critical variable for the MS system, operating with the APCI ionization mode. After optimization of the most important parameters through the variables selection technique, the selected ion-recording (SIR) mode, monitoring the [M + H](+) species for all the compounds, was applied for the method validation of the pesticides, in both ionization modes. In orange samples, matrix effects did not interfere with the determination of the pesticides. Pesticides quantification limits ranged from 10 to 50 microg kg(-1) for ESI and from 8.2 to 45 microg kg(-1) for APCI. Linearity was studied from LOQ upto 200 times LOQ values (r > 0.98). Recoveries obtained were in the range of 70.2-100.5% (RSDs less than 10%). In order to guarantee that the identification and confirmation of the studied pesticides in real samples were unequivocal, characteristic fragment ions of the pesticides were obtained by varying the cone voltage (in-source CID).  相似文献   

3.
A sensitive multi-residue analytical method, utilizing ethyl acetate extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS), has been developed and validated for simultaneous determination of 28 pesticides of different chemical classes (polar organophosphates, carbamates, strobilurines, neonicotinoids, amides, pyrimidines, benzimidazoles, imidazoles and triazoles), and their transformation products, in processed fruit and vegetables. Two precursor-product ion transitions were monitored for each pesticide in selected reaction monitoring (SRM) mode. Linearity (r (2) > or = 0.99) was good over the concentration range 0.5 to 100 microg L(-1) for all the pesticides, and instrumental detection limits ranged from 0.1 to 1 microg L(-1). Mean recovery for fruit and vegetables spiked at 0.010 mg kg(-1) ranged from 65 to 94.4%, and relative standard deviations ranged from 9.0 to 20.0%. When the amount spiked was 0.050 mg kg(-1) recoveries ranged from 72.5 to 90% and relative standard deviations were from 6.1 to 19.0%. Method detection limits were from 0.002 to 0.007 mg kg(-1) for the different food matrices studied. The method was used to monitor pesticide residues in a wide variety of fruits and vegetables.  相似文献   

4.
Amnesic shellfish poisoning (ASP) is a potentially lethal human toxic syndrome which is caused by domoic acid (DA) that originates in marine phytoplankton belonging to the Pseudonitzschia genus. A confirmatory and sensitive procedure has been developed and validated for the determination of DA in shellfish. The proposed method includes pressurised liquid extraction (PLE) with methanol/acetone (9:1), florisil clean-up purification inside the PLE extraction cell and detection by liquid chromatography (LC) coupled to electrospray ionization in positive mode tandem mass spectrometry (ESI-MS-MS). Comparison of ionization sources (ESI, atmospheric pressure ionization (APCI) atmospheric pressure photoionization (APPI) and combined APCI/APPI) were carried out in order to improve the analytical signal. The main parameters affecting the performance of the different ionization sources and PLE parameters were previously optimised using statistical design of experiments (DOE). Linear calibrations were obtained using mussel tissue extracts 0.05-5 microg DA/ml (R2>0.999). The limits of detection (LOD) and quantitation (LOQ) of the method were 0.2 and 0.5 microg/g respectively and recoveries ranged from 81 to 95%. This method was successfully applied to determine DA levels in 46 shellfish samples collected from Valencian (Spain) supermarkets, showing high sample throughput.  相似文献   

5.
A rapid analytical method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) using electrospray ionization in negative ion detection mode was developed for the analysis of underivatized iodoacetic acid in water. The method was applied to model reaction mixtures in the study of the formation of iodoacetic acid after chlorinated tap water was boiled in the presence of potassium iodide or iodized table salt. Samples can be directly analyzed by the LC/MS/MS system without extraction or chemical derivatization. Limit of detection was determined to be 0.3 microg/L (or 0.3 ng/mL) and limit of quantitation was about 1 microg/L (1 ng/mL).  相似文献   

6.
A rapid and simple analytical method has been established for the determination of methyl tert.-butyl ether (MTBE) and tert.-butyl alcohol (TBA), in seawater. The method involves purge-and-trap enrichment followed by gas chromatographic (GC) determination. Two different detection systems have been compared: atomic emission detection (AED) and MS (selected ion monitoring mode). Validation parameters and possible matrix effects have been evaluated. The linearity and analytical precision was good with both methods, but limits of detection reached by AED (10 microg l(-1)) were not low enough to evaluate current environmental concentrations. GC-MS detection presented much better sensitivity [limits of detection (LODs) of 0.04 microg l(-1) for MTBE and 0.09 microg l(-1) for TBA] and selectivity, providing a more reliable determination. The analysis of samples collected from various marinas in the south of Spain (Almería and Málaga) showed, in all cases, detectable concentrations of MTBE that ranged from below LOD to 1842 microg l(-1), depending on the sampling point and time. TBA was also detected in some cases, with concentration levels that ranged from 400 to 600 microg l(-1). These preliminary results should be followed by monitoring programs in coastal waters, in order to establish real levels of presence of MTBE in our coasts and its possible effect on the marine environment.  相似文献   

7.
Low level exposure to organophosphate (OP) pesticides can be determined by the measurement of dialkylphosphate (DAP) metabolites in urine. An analytical method is presented here which can measure the metabolites dimethyl phosphate (DMP), diethyl phosphate (DEP), dimethyl thiophosphate (DMTP), dimethyl dithiophosphate (DMDTP), diethyl thiophosphate (DETP), and diethyl dithiophosphate (DEDTP) at low levels. This was achieved by lyophilization of the urine, derivatization with pentafluorobenzyl bromide (PFBBr) and quantification by negative ion chemical ionization GC/MS-MS. The detection limits for the metabolites were 0.5 microg L(-1) DMP, 0.1 microg L(-1) DEP, 0.1 microg L(-1) DMTP, 0.04 microg L(-1) DMDTP, 0.04 microg L(-1) DETP and 0.02 microg L(-1) DEDTP. The RSD for the analytical method was 4-14% for the six metabolites. The method was used to monitor a group of non-occupationally exposed individuals in Sydney, Australia. The metabolites DMP, DEP, DMTP, DMDTP, DETP and DEDTP occurred in 73, 77, 96, 48, 100 and 2% of the samples with median values of 13, 3, 12, <1, 1 and 1 microg L(-1) respectively. The method is simple to use, sensitive and suitable for routine analysis of non-occupational exposure levels. These detection limits are between one and two orders of magnitude lower than those previously reported in the literature.  相似文献   

8.
A method for determination of nitrated polycyclic aromatic hydrocarbons (NPAHs) in diesel soot by high-performance liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization (APCI) and detection by ion-trap following ultrasonic extraction is described. The determination of 1-nitropyrene that it is the predominant NPAH in diesel soot was emphasized. Vaporization and drying temperatures of the APCI interface, electronic parameters of the MS detector and the analytical conditions in reversed-phase HPLC were optimized. The patterns of fragmentation of representative NPAHs were evaluated by single and multiple fragmentation steps and negative ionization led to the largest signals. The transition (247-->217) was employed for quantitative analysis of 1-nitropyrene. Calibration curves were linear between 1 and 15 microgL(-1) with correlation coefficients better than 0.999. Typical detection limit (DL) of 0.2 microgL(-1) was obtained. Samples of diesel soot and of the reference material (SRM-2975, NIST, USA) were extracted with methylene chloride. Recoveries were estimated by analysis of SRM 2975 and were between 82 and 105%. DL for 1-nitropyrene was better than 1.5 mg kg(-1), but the inclusion of an evaporation step in the sample processing procedure lowered the DL. The application of the method to diesel soot samples from bench motors showed levels 相似文献   

9.
熊治渝  董英  周洪斌  余杨  李静  孙莉 《色谱》2014,32(2):145-150
建立了在线富集方式结合离子色谱-质谱(IC-MS)快速分离分析16种有机酸的方法。离子色谱配备自制富集柱和分离柱对有机酸进行在线富集和分离;质谱采用大气压化学电离源负离子电离方式(APCI-),在选择离子监控(SIM)模式下对有机酸进行定性和定量分析。采用200 μL大体积进样,在线富集时间为3 min,以NaOH溶液作为淋洗液,梯度洗脱。结果表明,富集柱和分离柱对有机酸有很好的富集分离能力;16种有机酸在30 min内完全洗脱,并在一定浓度范围内线性关系良好;方法检出限(LODs)为0.01~0.22 mg/L;加标回收率为70.6%~110.8%,相对标准偏差(RSD)≤6.3%。该方法样品前处理简单,分离速度快,有机酸检测灵敏度高,适用于多种饲料添加剂样品中有机酸添加剂的检测。  相似文献   

10.
A simultaneous method for the trace determination of acidic, neutral herbicides and their transformation products in estuarine waters has been developed through an on-line solid-phase extraction method followed by liquid chromatography with diode array and mass spectrometric detection. An atmospheric pressure chemical ionization (APCI) interface was used in the negative ionization mode after optimization of the main APCI parameters. Limits of detection ranged from 0.1 to 0.02 ng/ml for 50 ml of acidified estuarine waters preconcentrated into polymeric precolumns and using time-scheduled selected ion monitoring mode. Two degradation products of the acidic herbicides (4-chloro-2-methylphenol and 2,4-dichlorophenol) did not show good signal response using APCI-MS at the concentration studied due to the higher fragmentor voltage needed for their determination. For molinate and the major degradation product of propanil, 3,4-dichloroaniline, positive ion mode was needed for APCI-MS detection. The proposed method was applied to the determination of herbicides in drainage waters from rice fields of the Delta del Ebro (Spain). During the 3-month monitoring of the herbicides, 8-hydroxybentazone and 4-chloro-2-methylphenoxyacetic acid were successively found in those samples.  相似文献   

11.
With 15 flavonoids as test compounds, the analytical performance of four modes of LC-MS, multiple MS (MSn) and tandem MS operation (atmospheric pressure chemical ionization (APCI), electrospray ionization, positive and negative ionization) was compared for two mass spectrometers, a triple-quadrupole and an ion-trap instrument. Two organic modifiers, methanol and acetonitrile, and two buffers, ammonium acetate and ammonium formate, were used. In general, the use of APCI in the negative ion mode gave the best response, with the signal intensities and the mass-spectral characteristics not differing significantly between the two instruments. The best results were obtained when methanol-ammonium formate (pH 4.0) was used as LC eluent. Under optimum conditions full-scan limits of detection of 0.1-30 mg/l were achieved in the negative APCI mode. Here it needs to be emphasized that up to 2-order response differences were found both between analytes and between modes of ionization. This implies that one should be very cautious when interpreting data on the screening of real-life samples. The main fragmentations observed in the MSn spectra on the ion-trap, or the tandem MS spectra on the triple-quadrupole were generally the same. The advantage of the former approach is the added possibility to ascertain precursor-->product ion relationships.  相似文献   

12.
ESI and APCI ionization techniques in both negative and positive ion modes were evaluated for simultaneous LC-MS analysis of the four tocopherol homologues (alpha, beta, gamma and delta). The ESI and APCI ionization of tocopherols in positive ion mode was not efficient and proceeded via two competitive mechanisms, with the formation of protonated pseudo-molecular ions and molecular ions, which adversely influenced the repeatability of MS signal. Ionization in negative ion mode in both ESI and APCI was more efficient as it only produced target deprotonated pseudo-molecular ions. The APCI in negative ion mode showed larger linearity range, lower detection limits and was less sensitive to the differences in chemical structure of analytes and nature of applied solvents than negative ion ESI. Negative ion APCI was, therefore, chosen for the development of LC-MS method for simultaneous determination of the four tocopherols in foods. A baseline separation of the tocopherols was achieved on novel pentafluorophenyl silica-based column Fluophase PFP. The use of methanol-water (95:5, v/v) as a mobile phase was preferable to the use of acetonitrile-water due to considerable gain in MS signal. The limits of quantifications were 9 ng/mL for alpha-tocopherol, 8 ng/mL for beta- and gamma- and 7.5 ng/mL for delta-tocopherol when 2 microL was injected. This method was successfully applied to determination of tocopherols in sunflower oil and milk.  相似文献   

13.
A practicable and selective liquid chromatography-mass spectrometry assay for the determination of two cyclooxygenase-2 inhibitors, etoricoxib and valdecoxib, in human plasma is presented. The analytical technique is based on reversed-phase high-performance liquid chromatography (HPLC) coupled to atmospheric pressure chemical ionisation (APCI) mass spectrometry (Finnigan Mat LCQ ion trap). Mass analysis was performed in the positive ion mode. The ion trap was operated in the tandem MS mode (MS2) and the transitions of etoricoxib (m/z 359.2 --> 280.3) and valdecoxib (m/z 315.1 --> 235.1) were followed by selected reaction monitoring. Retention times of etoricoxib and valdecoxib were 1.05 and 1.08 min, respectively. The method was validated over a linear range 10-2500 and 5-1000 microg/L using the other substrate as internal standard. After validation, the method was used to study the pharmacokinetic pro fi le of etoricoxib or valdecoxib in a healthy volunteer after administration of a single oral dose (valdecoxib, 20 mg; etoricoxib, 90 mg). The presented method was suf fi cient to cover more than 90% of the area under the plasma concentration time curve.  相似文献   

14.
The effect of nine different eluent compositions on the ionization efficiency of five flavonoids was studied using ion spray (IS), atmospheric pressure chemical ionization (APCI), and the novel atmospheric pressure photoionization (APPI), in positive and negative ion modes. The eluent composition had a great effect on the ionization efficiency, and the optimal ionization conditions were achieved in positive ion IS and APCI using 0.4% formic acid (pH 2.3) as a buffer, and in negative ion IS and APCI using ammonium acetate buffer adjusted to pH 4.0. For APPI work, the eluent of choice appeared to be a mixture of organic solvent and 5 mM aqueous ammonium acetate. The limits of detection (LODs) were determined in scan mode for the analytes by liquid chromatography/mass spectrometry using IS, APCI and APPI interfaces. The results show that negative ion IS with an eluent system consisting of acidic ammonium acetate buffer provides the best conditions for detection of flavonoids in mass spectrometry mode, their LODs being between 0.8 and 13 microM for an injection volume of 20 microl.  相似文献   

15.
A solid phase extraction (SPE) method for extraction and clean up of 9 synthetic corticosteroids was optimized for quantification by reversed-phase high-performance liquid chromatography/negative electrospray ionisation mass spectrometry. Clean up was accomplished using a mixed mode polymeric strong anion exchange SPE column. The final method was validated according to EU regulations for determination of residues of veterinarian drugs in products of animal origin. Initial results showed a large difference in ion suppression between samples of porcine and bovine urine. The aim of optimisation was to design a procedure that minimised this difference while using a single SPE procedure and a fast HPLC method that enabled sufficient separation of the epimers beta- and dexamethasone. To include conjugated corticosteroids in the analysis, the sample was hydrolysed with Helix Pomatia beta-glucuronidase/aryl sulfatase. For the final method, which included fluocinolone acetonid, triamcinolone acetonid, beclomethasone, flumethasone, dexamethasone, betamethasone, 6alpha-methylprednisolone, prednisone and prednisolone, a quantification based on spiked samples carried through the entire analytical procedure was used. For quantification of triamcinolone acetonid an internal standard (triamcinolone acetonid-D6) was used. Relative average recoveries from 96 to 103% were found, except for beclomethasone (113%). Absolute average recoveries were 81-99%. Quantification limits (decision limits, CCalpha) were demonstrated to be not higher than 1 microg L(-1) (3 microg L(-1) for prednisone and prednisolone). The internal reproducibility, determined by triplicates from spiking at three different levels in six analytical series was 7-19% (at 2-4 microg L(-1)) except for prednisone and prednisolone (26-27% at 3-6 microg L(-1)).  相似文献   

16.
An ion chromatographic (IC) method with suppressed conductivity detection (CD) was developed and validated for the quantitative determination of several low-molecular-mass aliphatic mono- and dicarboxylic acids as their carboxylate anions together with some inorganic anions (chloride, sulfate, and thiosulfate) from kraft black liquors. To confirm the identification of some carboxylate anions which lack commercial model substances, a qualitative IC method with suppressed electrospray ionization mass spectrometry (ESI-MS) was also developed. The separations were performed on an IonPac AS 11-HC anion-exchange column operated at 25 degrees C within 25 min by a gradient elution with aqueous potassium hydroxide (suppressed CD in the AutoRegen mode) or sodium hydroxide (suppressed ESI-MS in the pressurized bottle mode). In the validation process a mixture of carboxylic acids and inorganic anions in aqueous media and in seven different types of wood and non-wood black liquor samples were quantitatively analyzed by IC-CD. As a result, calibration lines with correlation coefficients of 1.00 for all analytes were achieved at a concentration range from 0.05 to 105 mg L(-1). In black liquor samples intra-day (n=6) precision values ranged from 0.9 to 5%. Day-to-day (n1=3) and intermediate precision values were less than 5% for all other compounds except sulfate and thiosulfate. The variability in the thiosulfate and sulfate results is due in large part to the oxidation of sulfide and thiosulfate, respectively. Recoveries were close to 100% with standard deviations less than 8%. Depending of the analyte, the limits of detection and quantification were, respectively, between 1 and 8 microg L(-1) and between 3 and 27 microg L(-1) for standard compounds in aqueous media and between 6 and 106 microg L(-1) and between 14 and 148 microg L(-1) for black liquor samples. These validation results clearly indicated that with respect to selectivity, linearity, limits of detection and quantification, precision, and accuracy, the IC-CD method showed good applicability in the determinations described above.  相似文献   

17.
An HPLC-MS-MS method with selected reaction monitoring (SRM) for the determination of patulin in apple juice samples is described. Mass spectrometric detection was accomplished following atmospheric pressure chemical ionization (APCI) in both positive and negative ion modes. Collision induced dissociation (CID) of the protonated molecular ion led initially to the loss of H2O (fragment m/z 137). At higher energies CO is lost from both the protonated parent molecule (fragment m/z 127) and the dehydrated molecular ion (fragment m/z 109). In contrast, CID of the deprotonated molecular ion led initially to the fragment at m/z 109 corresponding to the loss of either CO2 or acetaldehyde, followed at higher CID energy by the loss of H2O (fragment m/z 135) and CO (fragment m/z 125) from the deprotonated molecular ion. Detection in the negative ion mode proved superior and a linear response was observed over the injected range from 6 to 200 ng patulin. Apple juice samples spiked with patulin between 10 and 135 microg/l were analyzed following liquid-liquid extraction with ethyl acetate and clean up with sodium carbonate. Utilizing reversed-phase HPLC with acetonitrile-water (10:90) at 0.5 ml/min, levels down to 10 microg/l were readily quantified and a detection limit of 4 microg/l was attainable at a signal-to-noise (SIN) ratio of 4. The MS data for the spiked samples compared well to the UV data and when plotted against each other displayed a correlation coefficient (R) of 0.99.  相似文献   

18.
A rapid, selective and simple analytical procedure using tetrabutylammonium as ion pair in conjunction with solid-phase microextraction followed by in-port derivatization-GC-negative ion chemical ionization mass spectrometry was developed. The procedure allows an accurate determination of perfluoroalkylcarboxylic acids in aqueous samples at ng L(-1) levels (i.e. method detection limit 20 ng L(-1) forperfluorodecanoic acid) improving previous GC methods in terms of analysis time and sensitivity. Ammonia as reagent gas in the negative ion chemical ionization mass spectrometry increased the sensitivity at least 3-fold compared to methane for perfluorocarboxylic acid butyl esters. The developed procedure was successfully applied to effluents from wastewater treatment plants (i.e. 0.05-8.2 microg L(-1)) and harbor seawaters.  相似文献   

19.
开展了动物内脏中14种酞酸酯类(PAEs)环境激素残留的气相色谱-电子轰击离子源/质谱(GC-EI/MS)的分析方法研究。优化与选择了动物内脏样品的前处理条件,动物内脏样品经正己烷/二氯甲烷(1/1,v/v)混合提取剂超声提取、Florisil硅藻土固相萃取柱净化与乙酸乙酯/正己烷(2/3,v/v)混合洗脱剂洗脱和浓缩后,以邻苯二甲酸二苯基酯(DPhP)为内标物,采用GC-EI/MS的选择离子监测方式(SIM)进行定性和定量分析。当猪肝样品的加标浓度水平为100、200、400 μg/kg时,加标回收率为:60%~110%,相对标准偏差为:0.78%~10.3%;除邻苯二甲酸二(2-甲氧基乙基)酯(DMEP)与邻苯二甲酸二(2-乙氧基乙基)酯(DEEP)的检测限(MDL)分别为3.30与2.25 μg/kg外,其余的12种PAEs的MDL ≦ 1.74 μg/kg;线性范围为50 ~ 800 μg/kg,相关系数都大于0.9994。此分析方法成功地应用于6种动物内脏中14种痕量PAEs残留的分析。  相似文献   

20.
An analytical procedure that enables routine analysis for trace determination of six anabolic macrocyclic lactones (zearalenone, alpha- and beta-zearalenol, zearalanone, zeranol, and taleranol) in sewage treatment plant (STP) samples has been developed. The method uses solid-phase extraction, followed by high-performance liquid chromatography with on-line tandem mass spectrometry using atmospheric pressure chemical ionization (LC/APCI-MS/MS). The extraction of these compounds from filtered water samples was performed off-line with C(18) solid-phase cartridges. The detection was achieved by isocratic reversed-phase high-performance liquid chromatography coupled with an heated nebulizer (HN) APCI interface operating in negative ion mode. Mean recovery of the analytes in STP effluent samples generally exceeded 81%. This method was used to determine the occurrence of target analytes in the aquatic environment. In the selected STP effluent samples, zearalenone and alpha-zearalenol were detected in the ng/L range.  相似文献   