1.
Yu R  Hu Z  Ye M  Che J 《色谱》2012,30(4):409-413
建立了采用快速溶剂萃取-离子色谱同时测定塑料中三价铬和六价铬的方法。三价铬和六价铬分别以吡啶-2,6-二羧酸(PDCA)和1,5-二苯卡巴肼(DPC)作为络合剂在柱前和柱后进行衍生化,分别在紫外和可见波长下采用紫外检测器进行检测,灵敏度高,基体干扰小。本方法对三价铬和六价铬的检出限分别为5.0 μg/L和0.5 μg/L;分别在50~1000 μg/L和5.0~100 μg/L范围内呈现良好的线性关系,线性相关系数分别为0.9994和0.9998;三价铬和六价铬的回收率范围为90.7%~101.1%,相对标准偏差(RSD)为1.7%~4.4%。该方法分析速度快、灵敏度高、重现性好,可用于塑料中三价铬和六价铬的同时测定。  相似文献   

2.
A simple speciation, separation and enrichment method has been developed for the determination of Cr(III) and Cr(VI) ions in different samples by ion-pair solvent extraction with a β-diketone ligand, 2-(4-methoxybenzoyl)-N′-benzylidene-3-(4-methoxyphenyl)-3-oxo-N-phenyl-propono hydrazide (MBMP). Cr(III) was separated from Cr(VI) as Cr(III)-(MBMP)-perchlorate ternary ion-pair complex. The influences of various analytical parameters including pH, amount of reagent, shaking time, sample volume and ionic strength on the recovery of Cr(III) and/or Cr(VI) were investigated. Total chromium was obtained after reducing Cr(VI) to Cr(III) with NH2OH?·?HCl. Recoveries were found to be higher than 95% and the relative standard deviation (RSD) was less than 2%. The method detection limit based on 3σ criterion for Cr(III) was found to be 0.32?µg?L?1. The formed ternary ion-pair complex, Cr(III)?:?MBMP?:?2ClO4, has a molar ratio of 1?:?1?:?2. The developed method has been applied successfully to the speciation of chromium in various natural water, soil, sediment and hair samples with satisfactory results.  相似文献   

3.
A new procedure has been developed for chromium speciation in aqueous solution by the use of micellar, ion-association, solid-phase extraction techniques (SPE) followed by flame atomic absorption spectrometry. The method was based on the use of C-18 bonded phase silica SPE disks for retention of ion-associated Cr(VI) with cetyl trimethyl ammonium bromide (CTAB), elution of the retained species and subsequent detection by flame atomic absorption spectrometry (FAAS). Cr(III) was oxidized by potassium persulfate to Cr(VI), then the total chromium was retained on the disk and determined by FAAS. The amount of Cr(III) was calculated by the difference between the total and Cr(VI) values. The calculated limit of detections (LOD) (based on 3sigma) are 15 microg L(-1) and 20 microg L(-1) for Cr(VI) and Cr(III) respectively. No considerable interferences have been observed from other investigated anions and cations and the method has been successfully applied to water samples taken from the Karoon River in Khuzestan province.  相似文献   

4.
Cloud point extraction (CPE) was applied as a preconcentration step for HPLC speciation of chromium in aqueous solutions. Simultaneous preconcentration of Cr(III) and Cr(VI) in aqueous solutions was achieved by CPE with diethyldithiocarbamate (DDTC) as the chelating agent and Triton X-114 as the extractant. Baseline separation of the DDTC chelates of Cr(III) and Cr(VI) was realized on a RP-C18 column with the use of a mixture of methanol-water-acetonitrile (65:21:14, v/v) buffered with 0.05 M NaAc-HAc solution (pH 3.6) as the mobile phase at a flow rate of 1.0 ml min(-1). The precision (R.S.D.) for eight replicate injections of a mixture of 100 microg l(-1) of Cr(III) and Cr(VI) were 0.6 and 0.5% for the retention time, 4.1 and 4.6% for the peak area measurement, respectively. The concentration factor, which is defined as the concentration ratio of the analyte in the final diluted surfactant-rich extract ready for HPLC separation and in the initial solution, was 65 for Cr(III) and 19 for Cr(VI). The linear concentration range was from 50 to 1000 microg l(-1) for Cr(III) and 50-2000 microg l(-1) for Cr(VI). The detection limits of Cr(III) and Cr(VI) were 3.4 and 5.2 microg l(-1), respectively. The developed method was applied to the speciation of Cr(III) and Cr(VI) in snow water, river water, seawater and wastewater samples.  相似文献   

5.
Zhang N  Suleiman JS  He M  Hu B 《Talanta》2008,75(2):536-543
A new chromium(III)-imprinted 3-(2-aminoethylamino) propyltrimethoxysilane (AAPTS)-functionalized silica gel sorbent was synthesized by a surface imprinting technique and was employed as a selective solid-phase extraction material for speciation analysis of chromium in environmental water samples prior to its determination by inductively coupled plasma mass spectrometry (ICP-MS). The prepared Cr(III)-imprinted silica gel shows the selectivity coefficient of more than 700 for Cr(III) in the presence of Mn(II). The static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Cr(III) were 30.5 mg g(-1) and 13.4 mg g(-1). It was also found that Cr(VI) could be adsorbed at low pH by the prepared imprinted silica gel, and this finding makes it feasible to enrich and determine Cr(VI) at low pH without adding reducing reagents. The imprinted silica gel sorbent offered a fast kinetics for the adsorption and desorption of both chromium species. Under the optimized conditions, the detection limits of 4.43 pg mL(-1) and 8.30 pg mL(-1) with the relative standard deviations (R.S.D.s) of 4.44% and 4.41% (C=0.5 ng mL(-1), n=7) for Cr(III) and Cr(VI) were obtained, respectively. The proposed method was successfully applied to the speciation of trace chromium in environmental water samples. To validate the proposed method, two certified reference materials were analyzed and the determined values were in a good agreement with the certified values. The developed method is rapid, selective, sensitive and applicable for the speciation of trace chromium in environmental water samples.  相似文献   

6.
On the basis of the chromogenic reaction of chromium(VI) with 1,5-diphenylcarbohydrazide (DPC) on the surface of Polysorb C-18 beads and the sequential injection renewable surface technique (SI-RST), a highly sensitive reflect spectrophotometric method for the determination of chromium(III) and chromium(VI) was proposed. Considerations of system and flow cell design, and factors that influence the determination performance were discussed. With 300 microl of sample loaded and 0.6 mg of beads trapped, the linear response range was 0.02 - 0.5 mg l(-1) Cr(VI) with a detection limit (3 sigma) of 2.4 microg l(-1) Cr(VI). The method achieves a precision of 1.3% RSD (n = 11) and a throughput of 53 samples per hour. The determination of Cr(III) was based on the same reaction for the determination of Cr(VI) after being oxidized by (NH4)2S2O8. The precision of the oxidation method was evaluated using a 0.2 mg l(-1) Cr(III) standard, yielding an RSD of 2.5% (n = 11). The average recovery of Cr(III) oxidized was tested to be 99.1%. The proposed method was used in the simultaneous determination of Cr(VI) and Cr(III) in water samples, and the error was less than 3%.  相似文献   

7.
Li BH  Yan XP 《Electrophoresis》2007,28(9):1393-1398
A method was developed for high-throughput speciation analysis of chromium by on-line coupling of short-column capillary electrophoresis (SC-CE) and inductively coupled plasma mass spectrometry (ICP-MS). Baseline separation of Cr(III) and Cr(VI) was achieved within 1 min by SC-CE in a 15 cm x 75 microm id fused-silica capillary at 6 kV using 15 mM HNO(3) as running electrolyte. The precisions (RSD, n = 5) of migration time and peak area for Cr(III) and Cr(VI) were in the range of 1.8-2.4% and 2.2-5.7%, respectively. The limits of detection (3sigma) of Cr(III) and Cr(VI) were 1.8 and 1.9 microg/L, respectively. The synthesized samples containing Cr(III) and Cr(VI) species were determined by the developed SC-CE-ICP-MS hyphenated technique, and the recoveries of Cr(III) and Cr(VI) in the synthesized samples were in the range of 103-110% and 90-108%, respectively.  相似文献   

8.
A novel and selective method for the fast determination of trace amounts of chromium species in water samples has been developed. The procedure is based on the selective formation of chromium diethyldithiocarbamate complexes at different pH in the presence of Mn(II) as an enhancement agent of chromium signals followed by elution with organic eluents and determination by atomic flame absorption spectrometry. The maximum capacity of the employed disks was found to be (396±3) µg and (376±2) µg for Cr(III) and Cr(VI), respectively. The detection limit of the proposed method is 49 and 43 ng·L?1 for Cr(III) and Cr(VI), respectively. The proposed method was successfully applied for determination of chromium species Cr(III) and Cr(VI) in different water samples.  相似文献   

9.
Hagendorfer H  Goessler W 《Talanta》2008,76(3):656-661
Due to its extensive use in industrial processes, large quantities of chromium compounds are discharged into the environment. Common approaches for the speciation of Cr employ the determination of Cr(VI) and total Cr. The focus of the present work was a separation of Cr(III) and Cr(VI) species, with a minimum of sample preparation, by keeping an eye on the more relevant and toxic Cr(VI). For the successful simultaneous separation of both chromium species we implemented a RSpak NN-814 4DP (PEEK, 4 mm x 150 mm) multi-mode column using an eluent containing 90 mM ammonium sulfate and 10 mM ammonium nitrate, adjusted to pH 3.5. At a flow of 0.3 mL min(-1) the separation of both Cr species was possible within 8 min. Further the octopole reaction system of the inductively coupled plasma mass spectrometer was systematically studied and optimised to reduce the influence of polyatomic interferences. The major advantage of the developed method compared to published methods is that a derivatisation of the Cr(III) species--an invasion in the speciation--is not required. With the used multi-mode column both chromium species are retained. Furthermore the pH of the mobile phase (pH 3.5) prevents reduction of Cr(VI) as well as precipitation of Cr(III) during the analysis. A limit of determination of approximately 0.5 microg L(-1) for both chromium species with an injection volume of 25 microL was obtained. The optimised method was successfully applied to the determination of Cr(VI) in cement samples as well as chromium speciation analysis in homeopathic drugs.  相似文献   

10.
A method for the preconcentration and speciation of chromium in seawater was developed. On-line preconcentration and determination were carried out by using inductively coupled plasma atomic emission spectrometry (ICP-AES) with dual mini-columns containing a chelating resin. In this system, Cr(III) was collected on the first column. The effluent containing residual chromium from the first column was collected on the second column after passing through a reduction-switching unit, in which the reducing agent was introduced, or not, for the reduction of Cr(VI) to Cr(lII). Cr(VI) was determined as the difference between the concentration of pre-reduced Cr(VI) and Cr(III) in the effluent from the first column. The detection limits for Cr(III) and Cr(VI) were 0.04 and 0.09 microg l(-1), respectively.  相似文献   

11.
Doğutan M  Filik H  Tor I 《Talanta》2003,59(5):1053-1060
A new melamine based polymeric sequestering resin was prepared for preconcentration and separation of hexavalent chromium from water, and its sequestering action was investigated. The water-insoluble, cross-linked sequestering resin was formed by reaction with bromosuccinic acid and cross-linking of melamine. The active sequestering group on the resin is NH-(Succinic acid) or salt thereof. The resulting chelating resin was characterized by infrared spectra. The newly prepared resin quantitatively retained Cr(VI) at pH 2.0-4.0 when the flow rate was maintained between 1 and 5 ml min−1. The retained Cr(VI) was instantaneously eluted with 25 ml of 0.1 M NaOH. The chromium species were determined by a flame atomic absorption spectrometer. The limits of detection for Cr(VI) and Cr(III) were found to be 5.3 and 4.2 μg l−1, respectively. The precision and accuracy of the proposed procedure was checked by the use synthetic and reference steel samples. The established preconcentration method was successfully applied to the determination and selective separation of Cr(VI) in electroplating industry wastewater. Total concentrations determined by the spectrophotometric method (110.3±0.6 g l−1 Cr(VI) and 1.2±0.3 g l−1 Cr(III)) are compared with those found by FAAS and the obtained results (110.4±1.8 g l−1 Cr(VI) and 1.4±0.5 g l−1 Cr(III)) show good agreement.  相似文献   

12.
Gao RM  Zhao ZQ  Zhou QZ  Yuan DX 《Talanta》1993,40(5):637-640
A new spectrophotometric determination method of hexavalent chromium in waste water and plating baths is described based on the oxidation of beryllon III by chromium(VI) in 0.02M sulphuric acid medium. The decrease in the absorbance of beryllon III was measured at 482 nm with an apparent molar absorptivity of 5.15 x 10(4)1.mole(-1).cm(-1). Beer's law was obeyed for chromium(VI) over the range 0-25 mug/25 ml. After the oxidation of Cr(III) to Cr(VI) by ammonium persulphate, total chromium can be determined. Therefore, chromium(III) can be calculated by subtracting chromium(VI) from total chromium. The detection limit is 0.015 and 0.020 mug/25 ml for chromium(VI) and total chromium, respectively. A sensitive spectrophotometric method for trace Cr(III) and Cr(VI) in waste water and plating baths was developed with good precision and accuracy. The reaction is also discussed.  相似文献   

13.
Wei Q  Duan C  Wang J  Ma H  Du B 《Annali di chimica》2006,96(7-8):451-461
A new catalytic kinetic spectrophotometric method for the determination of trace amount of chromium (VI) in microemulsion medium has been developed. The method is based on the catalytic effect of chromium (VI) on the oxidation of nuclear fast red in the presence of Tween-80 microemulsion and HAc-NaAc buffer solution (pH = 5.2). The linear ranges are in the range of 0 approximately 0.0480 microg mL(-1) of Cr (VI) at 528 nm and the detection limit is 1.56x10(-9)g mL(-1). The method has been applied in determination of Cr (VI) in water and food samples with satisfactory results. The relative standard deviation is less than 4.6 % and the recovery is 93.5 approximately 104 %.  相似文献   

14.
The construction and performance characteristics of a novel chromate ion-selective membrane sensor are described and used for determining chromium(III) and chromium(VI) ions. The sensor is based on the use of a rhodamine-B chromate ion-associate complex as an electroactive material in a poly(vinyl chloride) membrane plasticized with o-nitrophenyloctyl ether as a solvent mediator. In a phosphate buffer solution of pH 6 - 7, the sensor displays a stable, reproducible and linear potential response over the concentration range of 1 x 10(-1) - 5 x 10(-6) mol l(-1) with an anionic Nernstian slope of 30.8 +/- 0.5 mV decade(-1) and a detection limit of 1 x 10(-6) mol l(-1) Cr(VI). High selectivity for Cr(VI) is offered over many common anions (e.g., I-, Br-, Cl-, IO4-, CN-, acetate, oxalate, citrate, sulfate, phosphate, thiosulfate, selenite, nitrate) and cations (e.g., Ag+, Ca2+, Sr2+, Co2+, Ni2+, Cu2+, Mn2+, Fe2+, Zn2+, Cd2+, Al3+, Cr3+). The sensor is used for determining Cr(VI) and/or Cr(III) ions in separate or mixed solutions after the oxidation of Cr(III) into Cr(VI) with H2O2. As low as 0.2 microg ml(-1) of chromium is determined with a precision of +/-1.2%. The chromium contents of some wastewater samples were accurately assessed, and the results agreed fairly well with data obtained by atomic absorption spectrometry.  相似文献   

15.
A simple and sensitive method has been developed for species selective determination of chromium(III) and chromium(VI) in water by electrothermal atomic absorption spectrometry. The procedure is based on selective absorption of Cr(III) on a cellulose micro column (pH 11, 0.5 mol L(-1) NaCl). Total chromium was subsequently determined after appropriate reduction of Cr(VI) to Cr(III). Recoveries of more than 97% were found. A concentration factor of 100 was achieved. The relative standard deviations (n=10) at the 40 ng L(-1) level for chromium(III) and chromium(VI) were 2.3% and 1.8% and corresponding limits of detection (based on 36) were 1.8 ng L(-1) and 5.1 ng L(-1), respectively. No interference effects have been observed from other investigated species and the method has been successfully applied to natural water samples.  相似文献   

16.
The presence of chromium in chromium-tanned leather represents a considerable health problem since it can lead to chronic allergic contact dermatitis. Apart from trivalent chromium (Cr(III)), which is used for tanning, leather often contains hexavalent chromium (Cr(VI)), resulting from the oxidation of Cr(III) during the tanning process. This study deals with the chromium compounds in simulated sweat when brought into contact with Cr(III) or Cr(VI) and with chromium-tanned leathers. A capillary electrophoresis (CE) method was developed, with inductively coupled plasma-sector field-mass spectrometry (ICP-SF-MS) for element-specific detection. Two different electrophoretic runs, applying once the positive and once the negative polarity mode, were necessary for the detection of positively and negatively charged chromium species. Although sometimes described in the literature, a pre-run derivatization of the chromium-species was not performed here to prevent species transformation. 50 mmol.L(-1) sodium phosphate at a pH of 2.5 was used as CE separation buffer and as make-up liquid for the CE-ICP-SF-MS interface. When applied to simulated sweat samples incubated with Cr(VI), this method showed that methionine is responsible for the reduction of Cr(VI) into Cr(III), which, at its turn, forms a complex with lactic acid. In the case of sweat plus Cr(III), the latter step was also seen. Applied to simulated sweat in contact with leather samples, the method developed showed the presence of the former species among a much more complex pattern.  相似文献   

17.
A simple, inexpensive method based on solid-phase extraction (SPE) on sawdust from Cedrus deodera has been developed for speciation of Cr(III) and Cr(VI) in environmental water samples. Because different exchange capacities were observed for the two forms of chromium at different pH—Cr(III) was selectively retained at pH 3 to 4 whereas Cr(VI) was retained at pH 1—complete separation of the two forms of chromium is possible. Retained species were eluted with 2.5 mL 0.1 mol L−1 HCl and 0.1 mol L−1 NaOH. Detection limits of 0.05 and 0.04 μg mL−1 were achieved for Cr(III) and Cr(VI), respectively, with enrichment factors of 100 and 80. Recovery was quantitative using 250 mL sample volume for Cr(III) and 200 mL for Cr(VI). Different kinetic and thermodynamic properties that affect sorption of the chromium species on the sawdust were also determined. Metal ion concentration was measured as the Cr(VI)–diphenylcarbazide complex by UV–visible spectroscopy. The method was successfully applied for speciation of chromium in environmental and industrial water samples.  相似文献   

18.
Zhu G  Li S 《The Analyst》2001,126(8):1453-1455
A novel method for the separation and preconcentration of Cr(III)/Cr(VI) with Lemna minor and determination by slurry atomization electrothermal atomic absorption spectrometry (ETAAS) was developed. A sample solution was added to a polyethylene beaker containing 10 mg of 160 mesh pre-treated Lemna minor, adjusted to pH 1.0, stirred for 8 min for selective absorption of Cr(III) and then centrifuged. The upper layer of solution was transferred into another polyethylene beaker containing 10 mg of 160 mesh pre-treated Lemna minor, adjusted to pH 5.0, stirred for 12 min for adsorption of the residual Cr(VI) and centrifuged. The two residues in two centrifuge tubes were washed twice with water, 2 ml of agar solution added, stirred for 2 min, then two slurries were prepared and used for the determination of Cr(III) and Cr(VI) by ETAAS. Detection limits (3sigma) of 0.01 microg L(-1) for Cr(III) and 0.03 microg L(-1) for Cr(VI) were obtained. The relative standard deviation was 2.8% for Cr(III) and 3.3% for Cr(VI) at the 1 microg L(-1) level. The method was applied to the determination of Cr(III)/Cr(VI) in water samples. The analytical recoveries of Cr(III) and Cr(VI) added to samples were 97-102 and 96-103%, respectively.  相似文献   

19.
Hexavalent chromium detection in the presence of a high load of colourants without any false positive and in-procedure oxidation of Cr(III) is an important area of study. Colourants are a class of interfering substances in many spectroscopic analyses and chromatographic separations and detection. A purification method using an on-line dialysis technique for ion chromatography (IC) has been developed to remove water-soluble anionic dyes and particulate colourants and other substances to facilitate Cr(VI) quantification and the method is discussed. The dialysis was optimized with Cr(VI) standard solutions for quantification. The efficacy of the procedure for the removal of anionic dyes and detection of Cr(VI) was checked with a Cr(VI) spiked synthetic preparation containing a water-soluble dye and trivalent chromium. Soluble Cr(VI) extracted with organic dyes from environmental samples was analyzed. The method has a detection limit of 5 microg/l, recovery rate of 100% and analysis time less than 20 min.  相似文献   

20.
A novel type of solvent named deep eutectic solvent (DES) has been considered as a green ionic liquid analogue. A novel method was developed for enrichment and speciation of chromium ion from water and food samples based on deep eutectic solvent and ultrasonic extraction. The procedure for this method was comprised of Cr(III) complex formation with a hydrophobic complexing agent (Z)‐N‐(3,5‐diphenyl‐1H‐pyrrol‐2‐yl)‐3,5‐diphenyl‐2H‐pyrrol‐2‐imine (azadipyrromethene dye). Metal complex was entrapped in a deep eutectic solvent as an extracting solvent. While Cr(III) recovery was quantitative, the recovery of Cr(VI) was found 5%. After reduction of Cr(VI) to Cr(III), the method was applied for determination of total chromium(III) ion. The amount of Cr(VI) was calculated as subtracting of Cr(III) from total chromium ion. Various analytical parameters were optimized. The certified reference materials were analyzed and standard addition method also carried out to real samples to check the accuracy of the developed method. Preconcentration factor was found to be 50. The limit of detection of chromium(III) was found to be 4.3 ng l‐1. The precision of developed method as the relative standard deviation (RSD) was found as 3.5 %. The developed method was applied successfully for the speciation of chromium ions in water and food samples.  相似文献   