首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The metabolic profile of polar (methanol) and non‐polar (hexane) extracts of Curcuma domestica, a widely used medicinal plant, was established using various different analytical techniques, including GC‐FID, GC‐MS, HR‐GC‐MS and analytical HPLC‐ESI‐MS/MS by means of LTQ‐Orbitrap technology. The major non‐volatile curcuminoids curcumin, demethoxycurcumin and bisdemethoxycurcumin were identified when their chromatographic and precursor ion masses were compared with those of authentic standard compounds. In this paper we describe for the first time a GC/MS‐based method for metabolic profiling of the hydrophilic extract. We also identified 61 polar metabolites as TMS derivatives. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
An accelerated solvent extraction coupled with gas chromatography‐tandem mass spectrometry (ASE‐GC‐MS/MS) method for detecting dinitolmide residue and its metabolite (3‐amino‐2‐methyl‐5‐nitrobenzamide, 3‐ANOT) in eggs was developed and optimized. The samples were extracted using ASE with acetonitrile as the extractant and were purified by passage through a neutral alumina solid‐phase extraction column. Then, the samples were analyzed using the GC‐MS/MS method. The optimized method parameters were validated according to the requirements set forth by the European Union and the Food and Drug Administration. The average recoveries of dinitolmide and 3‐ANOT from eggs (egg white, egg yolk, and whole egg) at the limit of quantification (LOQ), 0.5 maximum residue limit (MRL), 1 MRL, and 2 MRL were 82.74% to 87.49%, the relative standard deviations (RSDs) were less than 4.63%, and the intra‐day RSDs and the inter‐day RSDs were 2.96% to 5.21% and 3.94% to 6.34%, respectively. The limits of detection and the LOQ were 0.8 to 2.8 μg/kg and 3.0 to 10.0 μg/kg, respectively. The decision limits (CCα) were 3001.69 to 3006.48 μg/kg, and the detection capabilities (CCβ) were 3001.74 to 3005.22 μg/kg. Finally, the new method was successfully applied to the quantitative determination of dinitolmide and 3‐ANOT in 50 commercial eggs from local supermarkets.  相似文献   

3.
In this study, GC–MS‐ and MEKC‐based methods for determination of caffeine (CAF) in preworkout supplements were developed and validated. The proposed protocols utilized minimal sample preparation (simple dilution and syringe filtration). The developed methods achieved satisfactory validation parameters, i.e. good linearity (R2 > 0.9988 and R2 > 0.9985 for GC–MS‐ and MEKC‐based method, respectively), satisfactory intra‐ and interaccuracy (within 92.6–100.7% for method utilizing GC–MS and 92.1–110.3% for protocol based on MEKC) and precision (CV < 15.9% and CV < 6.3% for GC–MS‐ and MEKC‐based method, respectively) and recovery (within 100.1–100.8% for method utilizing GC–MS and 101.5–106.2% for protocol based on MEKC). The LOD was 0.03 and 3 μg/mL for method utilizing GC–MS and MEKC, respectively. The CAF concentrations determined by GC–MS‐ and MEKC‐based methods were found to be in the range of 8.53–11.23 and 8.20–11.61 μg/mL, respectively. Taking into consideration information on the labels, the investigated supplements were found to contain from 110.0 to 167.3% of the declared CAF content, which confirmed the literature reports on incompatibility of the declared product compositions with real ones. Nevertheless, the consumption of examined supplements as recommended by producers did not lead to exceeding the CAF safe limit of 400 mg per day. Additionally, the MEKC‐based method allowed for detection and identification of vitamin B3 and B6 in all of the investigated supplement samples, which demonstrated that MEKC‐based protocols may be an appropriate assays for simultaneous determination of CAF and vitamins.  相似文献   

4.
One of the many issues of designer drugs of abuse like synthetic cannabinoids (SCs) such as JWH‐018 is that details on their metabolism has yet to be fully elucidated and that multiple metabolites exist. The presence of isomeric compounds poses further challenges in their identification. Our group has previously shown the effectiveness of gas chromatography‐electron ionization‐tandem mass spectrometry (GC‐EI‐MS/MS) in the mass spectrometric differentiation of the positional isomers of the naphthoylindole‐type SC JWH‐081, and speculated that the same approach could be used for the metabolite isomers. Using JWH‐018 as a model SC, the aim of this study was to differentiate the positional isomers of its hydroxyindole metabolites by GC‐MS/MS. Standard compounds of JWH‐018 and its hydroxyindole metabolite positional isomers were first analyzed by GC‐EI‐MS in full scan mode, which was only able to differentiate the 4‐hydroxyindole isomer. Further GC‐MS/MS analysis was performed by selecting m/z 302 as the precursor ion. All four isomers produced characteristic product ions that enabled the differentiation between them. Using these ions, MRM analysis was performed on the urine of JWH‐018 administered mice and determined the hydroxyl positions to be at the 6‐position on the indole ring. GC‐EI‐MS/MS allowed for the regioisomeric differentiation of the hydroxyindole metabolite isomers of JWH‐018. Furthermore, analysis of the fragmentation patterns suggests that the present method has high potential to be extended to hydroxyindole metabolites of other naphthoylindole type SCs in identifying the position of the hydroxyl group on the indole ring. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
Like many new designer drugs of abuse, synthetic cannabinoids (SC) have structural or positional isomers which may or may not all be regulated under law. Differences in acute toxicity may exist between isomers which impose further burden in the fields of forensic toxicology, medicine and legislation. Isomer differentiation therefore becomes crucial from these standpoints as new designer drugs continuously emerge with just minor positional modifications to their preexisting analogs. The aim of this study was to differentiate the positional isomers of JWH‐081. Purchased standard compounds of JWH‐081 and its positional isomers were analyzed by gas chromatography‐electron ionization‐mass spectrometry (GC‐EI‐MS) first in scan mode to investigate those isomers who could be differentiated by EI scan spectra. Isomers with identical or near‐identical EI spectra were further subjected to GC‐tandem mass spectrometry (MS/MS) analysis with appropriate precursor ions. EI scan was able to distinguish 3 of the 7 isomers: 2‐methoxy, 7‐methoxy and 8‐methoxy. The remaining isomers exhibited near‐identical spectra; hence, MS/MS was performed by selecting m/z 185 and 157 as precursor ions. 3‐Methoxy and 5‐methoxy isomers produced characteristic product ions that enabled the differentiation between them. Product ion spectrum of 6‐methoxy isomer resembled that of JWH‐081; however, the relative ion intensities were clearly different from one another. The combination of EI scan and MS/MS allowed for the regioisomeric differentiation of the targeted compounds in this study. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
Precise measurement of low enrichment of stable isotope labeled amino‐acid tracers in tissue samples is a prerequisite in measuring tissue protein synthesis rates. The challenge of this analysis is augmented when small sample size is a critical factor. Muscle samples from human participants following an 8 h intravenous infusion of L‐[ring‐13C6]phenylalanine and a bolus dose of L‐[ring‐13C6]phenylalanine in a mouse were utilized. Liquid chromatography tandem mass spectrometry (LC/MS/MS), gas chromatography (GC) MS/MS and GC/MS were compared to the GC‐combustion‐isotope ratio MS (GC/C/IRMS), to measure mixed muscle protein enrichment of [ring‐13C6]phenylalanine enrichment. The sample isotope enrichment ranged from 0.0091 to 0.1312 molar percent excess. As compared with GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS showed coefficients of determination of R2 = 0.9962 and R2 = 0.9942, and 0.9217 respectively. However, the precision of measurements (coefficients of variation) for intra‐assay are 13.0%, 1.7%, 6.3% and 13.5% and for inter‐assay are 9.2%, 3.2%, 10.2% and 25% for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS, respectively. The muscle sample sizes required to obtain these results were 8 µg, 0.8 µg, 3 µg and 3 µg for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS, respectively. We conclude that LC/MS/MS is optimally suited for precise measurements of L‐[ring‐13C6]phenylalanine tracer enrichment in low abundance and in small quantity samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
张素艳  耿昱  郭寅龙  王浩  吕龙 《中国化学》2005,23(7):870-874
High performance liquid chromatography (HPLC) and electrospray ionization mass spectrometry (ESI-MS) have been utilized to analyze the synthesized 2-(2-arylaminomethylphenoxy)pyrimidine derivatives, which are a new kind of environmentally benign herbicides and have passed the temporary pesticide registration. The identification of main product and impurities has been achieved according to the UV and mass spectra. Moreover, one impurity, introduced by the raw material in the last step of the synthetic route, was identified by GC-MS analysis. It can be concluded that the combination of chromatography and mass spectrometry, including LC-MS and GC-MS, provided a vital tool of the pesticide science.  相似文献   

8.
In this study, a rapid and sensitive analytical method for the determination of methyl‐, ethyl‐, propyl‐, and butyl esters of para‐hydroxy benzoic acid (parabens) in personal care products was developed and fully validated. Test portions were extracted with methanol followed by vortexing, sonication, centrifugation, and filtration without derivatization. The four parabens were quantified by GC‐MS/MS in the electron ionization mode. Four corresponding isotopically labeled parabens were selected as internal standards, which were added at the beginning of the sample preparation and used to correct for recovery and matrix effects. Sensitivity, extraction efficiency, and recovery of the respective analytes were evaluated. The coefficients of determination (r2) were all greater than 0.995 for the four parabens investigated. The recoveries ranged from 97 to 107% at three spiked levels and a one‐time (single) extraction efficiency greater than 97% was obtained. This method has been applied to screen 26 personal care products. This is the first time that a unique GC‐MS/MS method with dynamic selected reaction monitoring and confirmation of analytes has been used to determine these parabens in cosmetic personal care products.  相似文献   

9.
对硅-550交联剂的组分进行了研究报道。通过GC对样品进行了研究分析,得到了七个分离很好的色谱峰以及样品中各组分的含量,再利用GC/MS联用技术和质谱裂解规律鉴定出样品各组分的分子结构。  相似文献   

10.
A simple and sensitive method was developed and validated for the simultaneous determination of 103 pesticide residues in tea by LC‐MS/MS. For the analysis of the pesticide with polarity, thermal lability or low volatility, this LC‐MS/MS method has an advantage over GC. In this work, residual pesticides were extracted from the tea sample with ACN and then purified using Carb‐NH2 SPE cartridges. Using the multiple reaction monitoring mode, the pesticides were quantified and identified by the most abundant and characteristic fragment ions. The recoveries obtained for each pesticide ranged between 65 and 114% at three spiked concentration levels. The intra‐day precisions were lower than 19.6%. Good linear relationships were observed with the correlation coefficients r2 >0.996 for all analytes. The established method was successfully applied to the determination of pesticide residues in real tea samples.  相似文献   

11.
《Analytical letters》2012,45(9):1865-1873
Abstract

Medroxyprogesterone acetate is a xenobiotic growth promoter of meat‐producing animals. In this study, the liver, kidney, and muscle of rabbits were obtained after the medroxyprogesterone acetate was administrated successively for 5 days at 0.8 mg/kg and withdrawn for 7 days before slaughter. The medroxyprogesterone acetate residues were determined by ELISA method. The average residue in muscle, liver, and kidney, as 7, 6, and 23 µg/kg, respectively. Residues were confirmed by GC/MS by monitoring four ions, 373, 283, 265, and 145 m/z. A good correlation was observed between the GC/MS and ELISA methods.  相似文献   

12.
GC/MS和ESI/MS/MS同位素内标法检测甲基丙二酸血症   总被引:6,自引:0,他引:6  
以甲基丙二酸血症为对象,分别用GC/MS和ESI/MS/MS方法对该疾病进行了定性和定量检测.通过对样品前处理和分离条件的改善,对疾病的标识化合物之一甲基丙二酸进行了定量测定,其稳定性、精密度和回收率结果很好.同时比较了GC/MS和ESI/MS/MS两种方法的特点,发现两种方法的结合不仅可满足新生儿代谢疾病筛查的要求,同时还可对高危人群进行诊断.  相似文献   

13.
A novel approach for differentiation and dating of red ink entries of seals on documents was developed based on ion‐pairing HPLC (IP‐HPLC) and GC/MS. Sixty‐nine red ink pastes of seals were collected and the chromatographic conditions for separation of the dye components by IP‐HPLC and the volatile additives by GC/MS in the ink entries were optimized. According to the dye components and additives, the ink entries were classified by HPLC with a multi‐wavelength UV detector. The volatile components of the inks were identified by GC/MS and the classification of the ink entries was also investigated based on these volatile additives. The results showed that most of the ink entries of the seals can be differentiated by combining HPLC with a multi‐wavelength detector and GC/MS methods. The degradation of the standard dye mixtures and the compositional changes of the ink entries of seals were investigated in light or natural aging conditions. The results indicated that the dye components decomposed in light or natural storage conditions, while the rates of the degradation depended on the structures of the dye components, the aging conditions, even the additives of the ink pastes. The results also showed that there existed good relationships between the compositional changes of the ink entries and the aging time, which can provide scientific evidences and valuable clues for dating of the ink entries.  相似文献   

14.
A simple, rapid and sensitive liquid chromatography with tandem mass spectrometry (LC‐MS/MS) method for the determination of periplocymarin in biological samples was developed and successfully applied to the pharmacokinetic and tissue distribution study of periplocymarin after oral administration of periplocin. Biological samples were processed with ethyl acetate by liquid–liquid extraction, and diazepam was used as the internal standard. Periplocymarin was analyzed on a C18 column with isocratic eluted mobile phase composed of methanol and water (containing 0.1% formic acid) at a flow rate of 0.2 mL/min (73:27, v/v). Detection was performed on a triple‐quadrupole tandem mass spectrometer using positive‐ion mode electrospray ionization in the selected reaction monitoring mode. The MS/MS ion transitions monitored were m/z 535.3→355.1 and 285.1→193.0 for periplocymarin and diazepam, respectively. Good linearity was observed over the concentration ranges. The lower limit of quantification was 0.5 ng/mL in plasma and tested tissues. The intra‐and inter‐day precisions (relative standard deviation) were <10.2 and 10.5%, respectively, and accuracies (relative error) were between ?6.8 and 8.9%. Recoveries in plasma and tissue were >90%. The validated method was successfully applied to the pharmacokinetic and tissue distribution studies of periplocymarin in rats. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

15.
Galanthamine‐type alkaloids produced by plants of the Amaryllidaceae family are potent acetylcholinesterase inhibitors. One of them, galanthamine, has been marketed as a hydrobromide salt for the treatment of Alzheimer's disease. In the present work, gas chromatography with electron impact mass spectrometry (GC‐EIMS) fragmentation of 12 reference compounds isolated from various amaryllidaceous plants and identified by spectroscopic methods (1D and 2D nuclear magnetic resonance, circular dichroism, high‐resolution MS (HRMS) and EIMS) was studied by tandem mass spectrometry (GC‐MS/MS) and accurate mass measurements (GC‐HRMS). The studied compounds showed good peak shape and efficient GC separation with a GC‐MS fragmentation pattern similar to that obtained by direct insertion probe. With the exception of galanthamine‐N‐oxide and N‐formylnorgalanthamine, the galanthamine‐type compounds showed abundant [M]+. and [M‐H]+ ions. A typical fragmentation pattern was also observed, depending on the substituents of the skeleton. Based on the fragmentation pathways of reference compounds, three other galanthamine‐type alkaloids, including 3‐O‐(2′‐butenoyl)sanguinine, which possesses a previously unelucidated structure, were identified in Leucojum aestivum ssp. pulchelum, a species endemic to the Balearic islands. GC‐MS can be successfully applied to Amaryllidaceae plant samples in the routine screening for potentially new or known bioactive molecules, chemotaxonomy, biodiversity and identification of impurities in pharmaceutical substances. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
Benzofurazan derivatization reagents, 4‐[2‐(N,N‐dimethylamino)ethylaminosulfonyl]‐7‐(2‐aminopentylamino)‐2,1,3‐benzoxadiazole (DAABD‐AP) and 4‐[2‐(N,N‐dimethylamino) ethylaminosulfonyl]‐7‐(2‐aminobutylamino)‐2,1,3‐benzoxadiazole (DAABD‐AB), for short‐chain carboxylic acids in liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) were synthesized. These reagents reacted with short chain carboxylic acids in the presence of the condensation reagents at 60°C for 60 min. The generated derivatives were separated on the reversed‐phase column and detected by ESI‐MS/MS with the detection limits of 0.1–0.12 pmol on column. Upon collision‐induced dissociation, a single and intense product ion at m/z 151 was observed. These results indicated that DAABD‐AP and DAABD‐AB are suitable as the derivatization reagents in LC/ESI‐MS/MS analysis. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

17.
A simple and sensitive gas chromatography/tandem mass spectrometry (GC/MS/MS) method is described for the detection of anabolic steroids, usually found in keratin matrix at very low concentrations. Hair samples from seven athletes who spontaneously reported their abuse of anabolic steroids, and in a single case cocaine, were analyzed for methyltestosterone, nandrolone, boldenone, fluoxymesterolone, cocaine and its metabolite benzoylecgonine. Anabolic steroids were determinate by digestion of hair samples in 1 m NaOH for 15 min at 95 degrees C. After cooling, samples were purificated by solid-phase and liquid-liquid extraction, then anabolic steroids were converted to their trimethylsilyl derivative and finally analyzed by GC/MS/MS. For detection of cocaine and benzoylecgonine, hair samples were extracted with methanol in an ultrasonic bath for 2 h at 56 degrees C then overnight in a thermostatic bath at the same temperature. After the incubation, methanol was evaporated to dryness, and benzoylecgonine was converted to its trimethylsilyl derivative prior of GC/MS/MS analysis. Results obtained are in agreement with the athletes' reports, confirming that hair is a valid biological matrix to establish long-term intake of drugs.  相似文献   

18.
In this study, a liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated to simultaneously determine the anticancer drugs etoposide and paclitaxel in mouse plasma and tissues including liver, kidney, lung, heart, spleen and brain. The analytes were extracted from the matrices of interest by liquid–liquid extraction using methyl tert‐butyl ether–dichloromethane (1:1, v/v). Chromatographic separation was achieved on an Ultimate XB‐C18 column (100 × 2.1 mm, 3 μm) at 40°C and the total run time was 4 min under a gradient elution. Ionization was conducted using electrospray ionization in the positive mode. Stable isotope etoposide‐d3 and docetaxel were used as the internal standards. The lower limit of quantitation (LLOQ) of etoposide was 1 ng/g tissue for all tissues and 0.5 ng/mL for plasma. The LLOQ of paclitaxel was 0.4 ng/g tissue and 0.2 ng/mL for all tissues and plasma, respectively. The coefficients of correlation for all of the analytes in the tissues and plasma were >0.99. Both intra‐ and inter‐day accuracy and precision were satisfactory. This method was successfully applied to measure plasma and tissue drug concentrations in mice treated with etoposide and paclitaxel‐loaded self‐microemulsifying drug‐delivery systems.  相似文献   

19.
A new analytical technique for the structural elucidation of four representative phenidate analogues possessing a secondary amine residue, which leads to a major/single amine‐representative fragment/product ion at m/z 84 both in their GC‐EI‐MS and LC‐ESI‐MS/MS spectra, making their identification ambiguous, was developed. The method is based on “in vial” chemical derivatization with isobutyl chloroformate in both aqueous and organic solutions, followed by liquid chromatography‐electrospray ionization mass spectrometry (LC‐ESI‐MS/MS). The resulting carbamate derivatives promote rich fragmentation patterns with full coverage of all substructures of the molecule, enabling detailed structural elucidation and unambiguous identification of the original compounds at low ng/mL levels.  相似文献   

20.
《Analytical letters》2012,45(13):2231-2245
Abstract

A rapid and reliable analytical method, at trace level concentration was developed and validated for monitoring polychlorinated biphenyls (PCBs) in Jordanian surface water. The method combines the advantage of liquid extraction together with gas chromatography‐mass spectrometry (GC/MS) and gas chromatography‐electron capture detector (GC/ECD). The performance of the method was evaluated by analyzing certified reference material (CRM) of the analytes and applied on real water samples collected from different sites in Jordan. A mixture of 60∶40 dichloromethan‐petroleum ether was chosen as a convenient binary solvent for liquid–liquid extraction. The GC conditions for GC/MS were optimized using He as a carrier gas, temperature programming, and chlorpropham as an internal standard (IS).

The conditions for GC/ECD were performed using N2 gas and a temperature program from 160 to 280°C with different increasing rates. The method of GC/MS in the selective ion mode (SIM) gave linear relationships for all PCBs tested between 0.60–6.0 µg/l with R 2=0.9934 (n=7×18). Recoveries from spiked water samples ranged between 87.6 and 91.4%. The mean accuracy and precision obtained were 4.9% and 2.16%, respectively. The mean of detection limit was 0.14±0.04 µg/l. In GC/ECD, linear relationships for all PCBs examined over the range of 0.3–2.4 µg/l was verified as characterized by a linear regression equation and correlation coefficient, R 2=0.9915 (n=12). The average precision and accuracy were 4.86% and 5.21%, respectively. Analyses results clarified that none of the examined Jordanian water samples contained any of the searched for PCBs within the detection limit achieved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏