首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Salmonella enterica subsp. enterica ser. enteritidis and Salmonella enterica subsp. enterica ser. typhimurium are the most common and severe food-borne pathogens responsible for causing salmonellosis in humans and animals. The development of an early and ultra-sensitive detection system is the first critical step in controlling this disease. To accomplish this, we used the cell systematic evolution of ligands by exponential enrichment (Cell-SELEX) technique to identify single-stranded DNA (ssDNA) aptamers to be used as detection probes that can specifically bind to S. enteritidis and S. typhimurium. A total of 12 target-specific ssDNA aptamers were obtained through ten rounds of Cell-SELEX under stringent selection conditions, and negative selection further enhanced the selectivity among these aptamers. Aptamer specificity was investigated using the gram-negative bacteria E. coli and P. aeruginosa and was found to be much higher towards S. enteritidis and S. typhimurium. Importantly, three candidate aptamers demonstrated higher binding affinities and the dissociation constants (Kd) were found to be in the range of nanomolar to submicromolar levels. Furthermore, individual aptamers were conjugated onto polyvalent directed aptamer polymer, which led to 100-fold increase in binding affinity compared to the individual aptamers alone. Taken together, this study reports the identification of higher affinity and specificity ssDNA aptamers (30mer), which may be useful as capture and detection probes in biosensor-based detection systems for salmonellosis.  相似文献   

2.
A novel CuS–graphene (CuS-Gr) composite was synthesized to achieve excellent electrochemical properties for application as a DNA electrochemical biosensor. CuS-Gr composite was prepared by a hydrothermal method, in which two-dimensional graphene served as a two-dimensional conductive skeleton to support CuS nanoparticles. A sensitive electrochemical DNA biosensor was fabricated by immobilizing single-stranded DNA (ss-DNA) labeled at the 5′ end using 6-mercapto-1-hexane (HS-ssDNA) on the surface of Au nanoparticles (AuNPs) to form ssDNA-S–AuNPs/CuS-Gr, and hybridization sensing was done in phosphate buffer. Cyclic voltammetry and electrochemical impedance spectroscopy were performed for the characterization of the modified electrodes. Differential pulse voltammetry was applied to monitor the DNA hybridization using an [Fe(CN)6]3?/4? solution as a probe. Under optimum conditions, the biosensor developed exhibited a good linear relationship between the current and the logarithm of the target DNA concentration ranging from 0.001 to 1 nM, with a low detection limit of 0.1 pM (3σ/S). The biosensor exhibited high selectivity to differentiate one-base-mismatched DNA and three-base-mismatched DNA. The results indicated that the sensing platform based on CuS-Gr provides a stable and conductive interface for electrochemical detection of DNA hybridization, and could easily be extended to the detection of other nucleic acids. Graphical abstracts
?  相似文献   

3.
We report on a lab-on-a-chip approach for on-site detection of Phytophthora species that allows visual signal readout. The results demonstrate the significance of single-stranded DNA (ssDNA) generation in terms of improving the intensity of the hybridization signal and to improve the reliability of the method. Conventional PCR with subsequent heat denaturation, sodium hydroxide-based denaturation, lambda exonuclease digestion and two asymmetric PCR methods were investigated for the species P. fragariae, P. kernoviae, and P. ramorum. The positioning of the capture probe within the amplified yeast GTP-binding protein (YPT1) target DNA was also of interest because it significantly influences the intensity of the signal. Statistical tests were used to validate the impact of the ssDNA generation methods and the capture-target probe position. The single-stranded target DNA generated by Linear-After-The-Exponential PCR (LATE-PCR) was found to produce signal intensities comparable to post-PCR exonuclease treatment. The LATE-PCR is the best method for the on-site detection of Phytophthora because the enzymatic digestion after PCR is more laborious and time-consuming. Figure
?  相似文献   

4.
We report herein the development of a highly sensitive colorimetric method for detection of d-Penicillamine using citrate-capped gold nanoparticles (AuNPs). This assay relies upon the distance-dependent of gold nanoparticles surface plasmon resonance band of gold nanoparticles. By replacing the thiol-containing chelator drug, d-Penicillamine, with citrate on the gold nanoparticles surface, a new peak appearing at a longer wavelength intensifies and shifts further to the red from the original peak position due to aggregation of gold nanoparticles which depends on ionic strength, gold nanoparticles and d-Penicillamine concentration. During this process, the plasmon band at 521 nm decreases gradually along with the formation of a new red-shifted band at 630 nm. The calibration curve which is derived from the ratio intensities of absorbance at longer wavelength (630 nm) to original wavelength (521 nm) displays a linear relation in the range of 5.0 × 10?6–3.0 × 10?4 M d-Penicillamine. Lower limit of detection for d-Penicillamine, at the signal-to-noise ratio of 3 (3σ), was 3.8 × 10?6 M. The developed methodology was successfully applied for the determination of d-Penicillamine in human urine and plasma.  相似文献   

5.
6.
Graphene is a two-dimensional carbon nanomaterial one atom thick. Interactions between graphene oxide (GO) and ssDNA containing different numbers of bases have been proved to be remarkably different. In this paper we propose a novel approach for turn-on fluorescence sensing determination of glucose. Hydrogen peroxide (H2O2) is produced by glucose oxidase-catalysed oxidation of glucose. In the presence of ferrous iron (Fe2+) the hydroxyl radical (?OH) is generated from H2O2 by the Fenton reaction. This attacks FAM-labelled long ssDNA causing irreversible cleavage, as a result of the oxidative effect of ?OH, producing an FAM-linked DNA fragment. Because of the weak interaction between GO and short FAM-linked DNA fragments, restoration of DNA fluorescence can be achieved by addition of glucose. Due to the excellent fluorescence quenching efficiency of GO and the specific catalysis of glucose oxidase, the sensitivity and selectivity of this method for GO-DNA sensing are extremely high. The linear range is from 0.5 to 10 μmol L?1 and the detection limit for glucose is 0.1 μmol L?1. The method has been successfully used for analysis of glucose in human serum. Figure
?  相似文献   

7.
A novel indicator-free DNA hybridization biosensor with a graphene-based nanocomposite as the enhanced sensing platform was developed for the detection of the BCR/ABL fusion gene in chronic myelogenous leukemia. The platform was constructed by homogenously distributing ordered FePt nanoparticles (NPs) onto the electrochemically reduced graphene oxide (ERGNO). The surface structure and electrochemical performance of the FePt/ERGNO nanocomposite were systematically investigated. Owing to the synergistic effects of FePt NPs and ERGNO with a large surface area and excellent electron transfer ability, the obtained nanocomposite greatly facilitated the sensing behavior for DNA detection, resulting in excellent sensitivity and selectivity. A remarkable change has been observed in the impedance spectra before and after hybridization of the probe single-stranded DNA (ssDNA) with the target DNA. Under the optimized conditions, the complementary target genes could be quantified in a wide range of 1.0?×?10?14 to 1.0?×?10?9 mol/L with a detection limit of 2.6?×?10?15 mol/L. The approach does not need an oligonucleotide probe or target to be labeled previously, which makes it advantageous in terms of simplicity and noninvasiveness.  相似文献   

8.
Small-molecular probe 18F-labeled bis(zinc(II)-dipicolylamine) complex (18F-FB-DPAZn2) was evaluated for PET imaging of sterile inflammation. In comparison with 18F-2-deoxy-β-d-glucose (18F-FDG), 18F-radiolabeled Annexin V (18F-FB-Annexin V) showed rapid clearance of radioactivity from the kidney and low uptake in most tissues. Both the lower radioactivity accumulation in brain and heart and the higher uptakes in the lung, liver, and intestine were observed for the biodistribution of 18F-FB-DPAZn2. In PET imaging, 18F-FDG showed significantly higher tumor and inflammation uptake than did of 18F-FB-DPAZn2 and 18F-FB-Annexin V in the S-180 fibrosarcoma mouse model and sterile inflammation mouse model. Both 18F-FB-DPAZn2 and 18F-FB-Annexin V performed the specifically localization in inflammation, and the ratios of inflammatory lesion-to-muscle and tumor-to-muscle were 1.83 ± 0.20 and 0.90 ± 0.12 (P < 0.05) for 18F-FB-DPAZn2, and 1.51 ± 0.14 and 1.21 ± 0.12 (P > 0.05) for 18F-FB-Annexin V, respectively. Terminal deoxynucleotide end-labeling (TUNEL) assays performed on the dissected tissues showed the significantly more TUNEL-positive nuclei in the inflammatory muscle than in tumor and normal muscle, and these TUNEL results correlated with the uptake of 18F-FB-DPAZn2 in dissected tissues. Biodistribution and PET imaging studies showed that the 18F-FB-DPAZn2 is suitable for imaging sterile inflammation in vivo and is capable of the differentiating tumor from inflammation.  相似文献   

9.
A glassy carbon electrode was modified with gold nanoparticles (Au-NPs) on a quaternized cellulose support in a film composed of poly(ethylene glycol diglycidyl ether) (PEGDGE), and Hb was immobilized on the Au-NPs. The sensor film was characterized by UV–vis spectra, scanning electron microscopy, and electrochemical impedance spectroscopy. Cyclic voltammetry of the Hb in the Au@Qc/PEGDGE film revealed a pair of well-defined and quasi reversible peaks for the protein heme Fe(III)/Fe(II) redox couple at about ?0.333 V (vs. SCE). The sensor film also exhibited good electrocatalytic activity for the reduction of nitric oxide and hydrogen peroxide. The amperometric response of the biosensor depends linearly on the concentration of nitric oxide in the 0.9 to 160 μM range, and the detection limit is as low as 12 nM (at 3σ). The response to hydrogen peroxide is linear in the 59 nM to 4.6 μM concentration range, and the detection limit is 16 nM (at 3σ). This biosensor is sensitive, reproducible, and long-term stable. Figure
An electrochemical biosensor based on the immobilization of hemoglobin in Au@Qc NPs /Poly ethylene glycol diglycidyl ether composite film is developed.  相似文献   

10.
A novel direct method for the determination of EDTA in alkaline radioactive evaporator residue solution was developed and validated based on ion chromatography with suppressed conductimetric detection and anion exchange columns (A Supp 4, 4 mm × 250 mm and A Supp 5, 4 mm × 150 mm). The yttrium-EDTA complex resulted one single chromatographic peak in the eluent and allowed the correct determination of EDTA in an alkaline, high concentration radioactive waste water. Depending on coexisting substances, suitable eluent is 10.0 mM carbonate buffer/pH 10.6 or 10.75 (t R,Y–EDTA = 7.01 and 6.4 min, respectively). For 10.0 mM carbonate buffer/pH 10.6 and isocratic flow rate of 1.0 cm3/min, a linear calibration curve was obtained from 5 to 40 mg/dm3 (r > 0.999) EDTA. Good resolution was achieved from commonly coexisting anions (chloride, nitrite, nitrate, sulphate, phosphate, bromide and citrate). The developed simple ion chromatographic method was applied for the assay of EDTA in various radioactive alkaline solutions.  相似文献   

11.
Point Mutations on the Kirsten rat sarcoma viral oncogene homolog (KRAS) have been identified as an important predictive biomarker for response to cancer therapy targeting the epidermal growth factor receptor. KRAS mutations are prevalent in up to 40 % of all colorectal carcinomas, and routinely conducted KRAS genotyping is becoming mandatory to predict therapy success and to reduce therapy costs. We report a low-cost, disposable and ready-to-use centrifugal microfluidic cartridge (termed GeneSlice) containing preloaded primers and probes. The GeneSlice cartridge enables the parallel detection of the seven most relevant KRAS point mutations by allele-specific real-time PCR. It represents a cost effective alternative to dideoxy-sequencing with a faster time-to-result (~ 2 h versus up to 20 h in case of dd-sequencing). Microfluidic processing of the GeneSlice along with allele-specific amplification and real-time detection are conducted in a slightly modified, commercially available PCR thermocycler. Intra-chip standard deviation of Cq values on the GeneSlices is negligible (GeneSlice 1: Cq,std.dev. = 0.13; GeneSlice 2: Cq,std.dev?=?0.26). In 23 of 24 experiments, the data for genotyping 6 cancer cell lines (n?=?4 per cell line) agreed with dd-sequencing. Additionally, DNA derived from microdissected formalin-fixed and paraffin embedded colorectal carcinomas of two cases was genotyped correctly and reproducibly (n?=?3 per patient; one GeneSlice excluded from evaluation). The GeneSlice therefore clearly demonstrated the potential to become a valuable tool for routine diagnostics of KRAS mutations by reducing costs and hands-on time. Figure
Photograph of a centrifugal microfluidic cartridge “GeneSlice” for multiplex genotyping of KRAS point mutations from tumor cell DNA by allele-specific real-time PCR. Information about the mutation status is required to predict success of state-of-the-art cancer therapy with antibodies  相似文献   

12.
In the present study, purification and properties of an extracellular neutral serine protease from the fungus Penicillium italicum and its potential application as an antioxidant peptides producer are reported. The protease was purified to homogeneity using ammonium sulfate precipitation, Sephacryl S-200 gel filtration, diethylaminoethanol (DEAE)-Sepharose ion exchange chromatography, and TSK-HPLC gel filtration with a 10.2-fold increase in specific activity and 25.8 % recovery. The purified enzyme appeared as single protein band with a molecular mass of 24 kDa in sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). The optimum pH and temperature for the proteolytic activity were pH 7.0 and 50 °C, respectively. The enzyme was stable in the pH range of 6.0–9.0. The protease was activated by divalent cations such as Ca2+ and Mg2+. Complete inhibition of the purified enzyme by phenylmethylsulfonyl fluoride confirmed that the protease was of serine-type. The purified enzyme revealed high stability and relatively broad specificity. Scorpaena notata muscle protein hydrolysates prepared using purified serine protease (protease from P. italicum (Prot-Pen)) showed good in vitro antioxidative activities. The antioxidant activities of Scorpaena muscle protein hydrolyzed by Prot-Pen (SMPH-PP) were evaluated using various antioxidant assays: 1, 1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activity, reducing power, ferrous chelating activity, and DNA nicking assay. SMPH-PP showed varying degrees of antioxidant activity and almost the same strongest protection against hydroxyl radical induced DNA breakage.  相似文献   

13.
Poly(p-chloromethyl styrene)-graft-poly(methyl methacrylate) (PCMS-g-PMMA) and poly(p-chloromethyl styrene)-graft-poly(benzyl methacrylate) (PCMS-g-PBzMA) graft copolymers with asymmetric branches are synthesized via the combination of cationic polymerization and atom transfer radical polymerization (ATRP). The process involves first, the preparation of poly(p-chloromethyl styrene) (PCMS-CH2Cl) macroinitiator without any cross-linking or side reactions through pendant benzyl chloride (?CH2Cl) functionality by cationic polymerization using a simple FeCl3-based initiating system at 25 °C. The as-synthesized PCMS-CH2Cl, without any transformation, is then used as the macroinitiator to graft PMMA and PBzMA branches by ATRP to produce PCMS-g-PMMA and PCMS-g-PBzMA graft copolymers of varying compositions with controlled molecular weight and moderately narrow polydispersities (M w/M n?≤?1.32). The resulting PCMS21 -g-PMMA232 graft copolymer in thin film form phase separates into spherical morphology with an average diameter of 170?±?72 nm. Whereas the PCMS21 -g-PBzMA156 graft copolymer gives worm-like nanostructures with an average length of 94 nm and width of 31 nm due to phase separation as visualized through atomic force microscopy. On the other hand, the phase-separated morphology is not very well-defined for other graft copolymers (PCMS113 -g-PMMA227 and PCMS113 -g-PBzMA154) thin films containing longer PCMS chains. This approach represents a rapid and convenient route to prepare unique spherical/worm-like polymer nanostructures. Figure
Well-defined poly(p-chloromethyl styrene)-graft-poly(methyl methacrylate) (PCMS-g-PMMA) and poly(p-chloromethyl styrene)-graft-poly(benzyl methacrylate) (PCMS-g-PBzMA) graft copolymers with asymmetric branches are synthesized by the combination of living cationic polymerization and atom transfer radical polymerization (ATRP). The resulting PCMS21 -g-PMMA232 and PCMS21 -g-PBzMA156 graft copolymers phase separate into nanostructured spherical and worm-like morphologies, respectively, in thin film form. The phase-separated morphology is not very well-defined for graft copolymers (PCMS113 -g-PMMA227 and PCMS113 -g-PBzMA154) thin films containing longer PCMS chains.  相似文献   

14.
Plasmid calibrators are increasingly applied for polymerase chain reaction (PCR) analysis of genetically modified organisms (GMOs). To evaluate the commutability between plasmid DNA (pDNA) and genomic DNA (gDNA) as calibrators, a plasmid molecule, pBSTopas, was constructed, harboring a Topas 19/2 event-specific sequence and a partial sequence of the rapeseed reference gene CruA. Assays of the pDNA showed similar limits of detection (five copies for Topas 19/2 and CruA) and quantification (40 copies for Topas 19/2 and 20 for CruA) as those for the gDNA. Comparisons of plasmid and genomic standard curves indicated that the slopes, intercepts, and PCR efficiency for pBSTopas were significantly different from CRM Topas 19/2 gDNA for quantitative analysis of GMOs. Three correction methods were used to calibrate the quantitative analysis of control samples using pDNA as calibrators: model a, or coefficient value a (Cva); model b, or coefficient value b (Cvb); and the novel model c or coefficient formula (Cf). Cva and Cvb gave similar estimated values for the control samples, and the quantitative bias of the low concentration sample exceeded the acceptable range within ±25 % in two of the four repeats. Using Cfs to normalize the Ct values of test samples, the estimated values were very close to the reference values (bias ?13.27 to 13.05 %). In the validation of control samples, model c was more appropriate than Cva or Cvb. The application of Cf allowed pBSTopas to substitute for Topas 19/2 gDNA as a calibrator to accurately quantify the GMO. Graphical Abstract
?  相似文献   

15.
High-performance liquid chromatography with chemiluminescence detection based on the reaction with acidic potassium permanganate and formaldehyde was explored for the determination of neurotransmitters and their metabolites. The neurotransmitters norepinephrine and dopamine were quantified in the left and right hemispheres of rat hippocampus, nucleus accumbens and prefrontal cortex, and the metabolites vanillylmandelic acid, 3,4-dihydrophenylacetic acid, 5-hydroxyindole-3-acetic acid and homovanillic acid were identified in human urine. Under optimised chemiluminescence reagent conditions, the limits of detection for these analytes ranged from 2.5?×?10?8 to 2.5?×?10?7 M. For the determination of neurotransmitter metabolites in urine, a two-dimensional high-performance liquid chromatography (2D-HPLC) separation operated in heart-cutting mode was developed to overcome the peak capacity limitations of the one-dimensional separation. This approach provided the greater separation power of 2D-HPLC with analysis times comparable to conventional one-dimensional separations. Figure
2D-HPLC separation and permanganate chemiluminescence detection of neurotransmitter metabolites  相似文献   

16.
The binuclear copper(II) complex [Cu2L(CH3COO)] (I), where L3? is the azomethine trianion based on 3-methyl-4-formyl-1-phenylpyrazol-5-one and 1,3-diaminopropan-2-ol, and its DMSO adduct (II) in which the DMSO molecule acts as an additional bridging ligand are synthesized. The structure of complex II is determined by X-ray diffraction analysis, and the structure parameters of the coordination unit of complex I are determined by EXAFS spectroscopy. The μ2-coordination of the DMSO molecule in compound II results in a change in the sign of the exchange interaction parameter. In complex I, the antiferromagnetic exchange interaction (2J = ?169 cm?1) occurs between the copper(II) ions. The exchange interaction of the ferromagnetic type (2J = 174 cm?1) is observed in complex II. The quantum-chemical calculations of the magnetic exchange parameters by the density functional theory method show that the role of the DMSO molecule as a switch of the exchange interaction character is exclusively the stabilization of the “broken” conformation of the metallocycles.  相似文献   

17.
An electrochemical glucose biosensor was developed by immobilizing glucose oxidase (GOx) on a glass carbon electrode that was modified with molybdenum disulfide (MoS2) nanosheets that were decorated with gold nanoparticles (AuNPs). The electrochemical performance of the modified electrode was investigated by cyclic voltammetry, and it is found that use of the AuNPs-decorated MoS2 nanocomposite accelerates the electron transfer from electrode to the immobilized enzyme. This enables the direct electrochemistry of GOx without any electron mediator. The synergistic effect the MoS2 nanosheets and the AuNPs result in excellent electrocatalytic activity. Glucose can be detected in the concentration range from 10 to 300 μM, and down to levels as low as 2.8 μM. The biosensor also displays good reproducibility and long-term stability, suggesting that it represents a promising tool for biological assays. Figure
A MoS2-based glucose sensor has been prepared by gold nanoparticles-decorated MoS2 nanocomposite, which exhibited excellent electrocatalytic activity, reproducibility and long-term stability. It was applied to determine glucose concentration in human serum, suggest the sensor maybe promising for practical application.  相似文献   

18.
The internal energy distributions for dried and liquid samples that were vaporized with femtosecond duration laser pulses centered at 800 nm and postionized by electrospray ionization-mass spectrometry (LEMS) were measured and compared with conventional electrospray ionization mass spectrometry (ESI-MS). The internal energies of the mass spectral techniques were determined by plotting the ratio of the intact parent molecular features to all integrated ion intensities of the fragments as a function of collisional energy using benzylpyridinium salts and peptides. Measurements of dried p-substituted benzylpyridinium salts using LEMS resulted in a greater extent of fragmentation in addition to the benzyl cation. The mean relative internal energies, int> were determined to be 1.62?±?0.06, 2.0?±?0.5, and 1.6?±?0.3 eV for ESI-MS, dried LEMS, and liquid LEMS studies, respectively. Two-photon resonances with the laser pulses likely caused lower survival yields in LEMS analyses of dried samples but not liquid samples. In studies with larger biomolecules, LEMS analyses of dried samples from glass showed a decrease in survival yield compared with conventional ESI-MS for leucine enkephalin and bradykinin of ~15% and 11%, respectively. The survival yields for liquid LEMS analyses were comparable to or better than ESI-MS for benzylpyridinium salts and large biomolecules. Figure
?  相似文献   

19.
A number of molecular diagnostic methods have been developed for the detection and identification of mutations in tumor samples, which are important for the choice of treatment in the context of personalized medicine. For the treatment of metastatic melanoma, Vemurafenib is recommended for patients with BRAF V600 activating mutations. However, the different assays developed to date for the detection of these mutations lack sensitivity or specificity or do not allow a sequencing-based identification or validation of the mutation. Recently, enhanced improved and complete enrichment co-amplification at lower denaturation temperature-polymerase chain reaction (E-ice-COLD-PCR) has been developed as a sensitive method for the detection and identification of mutations in KRAS codons 12/13. Here, we present the first E-ice-COLD-PCR assay for the detection and identification of BRAF codon 600 mutations, which has a large dynamic range, as 25 pg to 25 ng can be used as DNA input without any reduction in mutation enrichment efficiency, and which can detect down to 0.01 % of mutated alleles in a wild-type background. The assay has been validated on fresh frozen, formalin-fixed paraffin-embedded (FFPE), and plasma samples of melanoma patients and has allowed the detection and identification of BRAF mutations present in samples appearing as wild type using standard pyrosequencing, endpoint genotyping, or Sanger sequencing. Thus, the BRAF V600 E-ice-COLD-PCR assay is currently one of the most powerful molecular diagnostic tools for the ultrasensitive detection and identification of BRAF codon 600 mutations.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号