首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
We have employed a light-absorbing electrically conductive polymer as a matrix to determine the molecular mass of small organic molecules using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. This method, which is in contrast to the usual MALDI strategy for matrix selection in which a small molecule matrix is used with a high molecular mass analyte, addresses the problem of matrix interference which limits the usefulness of MALDI-TOF for small molecule analysis. Use of negative ion mode offers advantages for this application. Using this approach, we have obtained clean molecular ion mass spectra of small organic molecules in the mass range 100-300 Da.  相似文献   

2.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has successfully been used to differentiate pseudo-enantiomeric (isotopically labelled) amino acids by using cyclodextrin as complexing host. By using different pseudo-enantiomeric mixtures (i.e. R(Dn) + S; and R + S(Dn)), it has been demonstrated that the preference of cyclodextrin for S-enantiomers is not due to the size differences caused by the hydrogen/deuterium substitution. It is postulated that this method can be extended to differentiate enantiomers (and determine enantiomeric excess) by using a pair of enantiomeric hosts, as demonstrated previously using other ionization techniques, but with much higher sensitivity.  相似文献   

3.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) has been used successfully to detect phosphorylation sites in proteins. Applications may be limited by the low response of phosphopeptides compared to nonphosphorylated peptides in MALDI MS. The addition of ammonium salts to the matrix/analyte solution substantially enhances the signal for phosphopeptides. In examples shown for equimolar mixtures, the phosphorylated peptide peaks become the largest peaks in the spectrum upon ammonium ion addition. This can allow for the identification of phosphopeptides in an unfractionated proteolytic digestion mixture. Sufficient numbers of protonated phosphopeptides can be generated such that they can be subjected to postsource decay analysis, in order to confirm the number of phosphate groups present. The approach works well with the common MALDI matrices such as α-cyano-4-hydroxycinnamic acid and 2,5-dihydroxybenzoic acid, and with ammonium salts such as diammonium citrate and ammonium acetate.  相似文献   

4.
The identification of isoforms is one of the great challenges in proteomics due to the large number of identical amino acids preventing their separations by two-dimensional electrophoresis. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has become a rapid and sensitive tool in proteomics, notably with the new instrumental improvements. In this study, we used several acquisition modes of MALDI-TOFMS to identify isoforms of porcine glutathiones S-transferase. The use of multiple proteases coupled to the different acquisition modes of MALDI-TOFMS (linear, reflectron, post-source decay (PSD) and in-source decay, positive and negative modes) allowed the identification of two sequences. Moreover, a third sequence is pointed out from a PSD study of a tryptic ion revealing the modification of the amino acid tyrosine 146 to phenylalanine.  相似文献   

5.
In this report, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was used to study the binding interactions between calmodulin and two target peptides (melittin and substance P). Various matrix conditions were tested and the less acidic matrix DHAP and THAP were found to favor the survival of the intact calcium-calmodulin as well as the calmodulin-peptide complexes. However, the application of direct MALDI-MS to detect the intact complexes turned out to be very difficult due to the dissociation of the complexes and the formation of nonspecific aggregates. In contrast, the specific binding of the target peptides to calmodulin could be easily deduced using intensity-fading (IF) MALDI-MS. Compared with the nonbinding control, clear reduction in the ion abundances of the target peptides was observed with the addition of calmodulin. Relative binding affinities of different peptides towards the protein could also be estimated using IF-MALDI-MS. This study may extend the application of IF-MALDI-MS in the analysis of noncovalent complexes and offer a perspective into the utility of MALDI-MS as an alternative approach to study the peptides binding to calmodulin.  相似文献   

6.
Polymer surface-peptide binding interactions have been shown previously to lead to reductions in peptide matrix assisted laser desorption/ionization (MALDI) ion signals. In previous studies, increases in surface-peptide binding were characterized by the increases in both the initially adsorbed and retained quantities of 125I-radiolabeled peptides. The present studies establish a specific correlation between the peptide retention properties of the polymer surface and the reduction in the peptide MALDI ion signal. This correlation is demonstrated by obtaining MALDI mass spectra of angiotensin I applied to various polymer surfaces having a range of peptide adsorption and retention properties. In addition, the use of a MALDI based method of standard additions is shown to allow the quantitation of the polymer surface-peptide retention affinity for angiotensin I and porcine insulin. The MALDI standard additions method for measurement of surface-peptide retention affinities offers a number of significant advantages over conventional radiolabeled peptide binding methods and promises to be a valuable tool for the determination of this important biomaterial characteristic.  相似文献   

7.
Daniel JM  Ehala S  Friess SD  Zenobi R 《The Analyst》2004,129(7):574-578
A new technique is presented for the coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) mass spectrometry with liquid delivery systems. Mass measurements of polymers and peptides are demonstrated using a co-dissolved matrix, e.g. alpha-cyano-4-hydroxycinnamic acid (HCCA). Improvements in terms of sensitivity are achieved by optimizing the shape und control of the exit capillary and by using a laser (355 nm) at a 1 kHz repetition rate. Two calibration experiments promise a good applicability of the presented coupling method for quantitative measurements. The limit of detection achieved so far is 500 nM for peptides in methanol solution containing 25 mM HCCA.  相似文献   

8.
A new two-component system, consisting of a matrix and an onium salt as comatrix, is described for detection of sulfo-peptides in the positive mode by matrix-assisted desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). Binary iodonium salts were superior to quaternary phosphonium salts in terms of suppression of desulfation and salt formation with the carboxyl group. Of the iodonium salts examined, bis(4-tert-butylphenyl)iodonium (BTI) hexafluorophosphate and bromide were most effective in giving intensive molecular ion signals in the form of [M(BTI)+BTI](+). The conditions optimized for O-sulfated tyrosine-containing peptides could be applicable for O-sulfated serine- and threonine-containing peptides. In the case of a phospho-peptide, a molecular ion appeared more intensively as a proton adduct than as a BTI adduct.  相似文献   

9.
10.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been one of the most powerful tools for analyzing protein phosphorylation. However, it is frequently difficult to detect phosphopeptides with high sensitivity by MALDI-MS. In our investigation of matrix/matrix-additive substances for improving the phosphopeptide ion response in MALDI-MS, we found that the addition of low-concentration alkylphosphonic acid to the matrix/analyte solution significantly enhanced the signal of phosphopeptides. In this study, the combination of methanediphosphonic acid and 2,5-dihydroxybenzoic acid gave the best results. In addition to enhancing the signal of the phosphopeptides, alkylphosphonic acid almost completely eliminated the signals of sodium and potassium ion adducts. We report herein sensitive detection of phosphopeptides by MALDI-MS with the use of alkylphosphonic acids as matrix additives.  相似文献   

11.
Tetrathiofulvalene compounds are important components of charge-transfer complexes, which may be applied in various fields of scientific research and practical applications. Some of these compounds cannot be characterized by mass spectrometry. Here, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry was used for the characterization of tetrathiofulvalenes. The samples could be easily desorbed and ionized to form singly charged ions, and mass spectra with isotopic resolution readily obtained. The mass spectrometric results for 26 compounds have shown that MALDI-TOF is more effective and convenient than other mass spectrometry methods, and resolves the problem of mass spectrometric characterization of tetrathiofulvalene compounds.  相似文献   

12.
Cysteine sulfonic acid-containing peptides, being typical acidic peptides, exhibit low response in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. In this study, matrix conditions and the effect of diammonium hydrogencitrate (DAHC) as additive were investigated for ionization of cysteine sulfonic acid-containing peptides in MALDI. A matrix-free ionization method, desorption/ionization on porous silicon (DIOS), was also utilized to evaluate the effect of DAHC. When equimolar three-component mixtures of peptides carrying free cysteine, cysteine sulfonic acid, and carbamidomethyl cysteine were measured by MALDI using a common matrix, alpha-cyano-4-hydroxycinnamic acid (CHCA), no signal corresponding to cysteine sulfonic acid-containing peptide could be observed in the mass spectrum. However, by addition of DAHC to CHCA, the peaks of cysteine sulfonic acid-containing peptides were successfully observed, as well as when using 2,4,6-trihydroxyacetophenone (THAP) and 2,6-dihydroxyacetophenone with DAHC. In the DIOS mass spectra of these analytes, the use of DAHC also enhanced the peak intensity of the cysteine sulfonic acid-containing peptides. On the basis of studies with these model peptides, tryptic digests of oxidized peroxiredoxin 6 were examined as a complex peptide mixture by MALDI and DIOS. In MALDI, the peaks of cysteine sulfonic acid-containing peptides were observed when using THAP/DAHC as the matrix, but this was not so with CHCA. In DIOS, the signal from cysteine sulfonic acid-containing peptides was suppressed; however, the use of DAHC significantly enhanced the signal intensity with an increase in the number of observed peptides and increased signal-to-noise ratio in the DIOS spectra. The results show that DAHC in the matrix or on the DIOS chip decreases discrimination and suppression effects in addition to suppressing alkali-adduct ions, which leads to a beneficial effect on protonation of peptides containing cysteine sulfonic acid.  相似文献   

13.
In this paper, mesoporous tungsten titanate (WTiO) with different nano-pore structures was utilized as matrix for the analysis of short peptides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). Effect of characteristic features of mesoporous matrices on laser desorption/ionization process was investigated. Experiments showed that the ordered two-dimensional and three-dimensional mesoporous matrices were superior in performance to the non-ordered WTiO matrix. The dramatic enhancement of signal sensitivity by the ordered mesoporous matrices can be reasonably attributed to the ordered structure, which facilitated the understanding on structure-function relationship in mesoporous cavity for laser desorption process of adsorbed biomolecules. With the ordered mesoporous matrix, the short peptides are successfully detected. The presence of trace alkali metal salt effectively increased the analyte ion yields and the MALDI-TOFMS using the inorganic mesoporous matrices displayed a high salt tolerance. The developed technique also showed a satisfactory performance in peptide-mapping and amino-acid sequencing analysis.  相似文献   

14.
Mass spectrometry imaging (MSI) of volatile metabolites is challenging, especially in matrix-assisted laser desorption/ionization (MALDI). Most MALDI ion sources operate in vacuum, which leads to the vaporization of volatile metabolites during analysis. In addition, tissue samples are often dried during sample preparation, leading to the loss of volatile metabolites even for other MSI techniques. On-tissue chemical derivatization can dramatically reduce the volatility of analytes. Herein, a derivatization method is proposed utilizing N,N,N-trimethyl-2-(piperazin-1-yl)ethan-1-aminium iodide to chemically modify short-chain fatty acids in chicken cecum, ileum, and jejunum tissue sections before sample preparation for MSI visualization.  相似文献   

15.
3-Hydroxycoumarin (3-HC) was designed, synthesized, and tested as a matrix for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) analyses of a variety of synthetic oligodeoxynucleotides ranging long from three to 70 bases. Using the matrix solution of 3-HC dissolved in a mixed solvent of acetone and diammonium hydrogen citrate, DNA segments over the mass range 800 Da to 6900 Da were isotopically resolved with high signal-to-noise (S/N) ratio. The individual isotopic molecular ion peaks of a group of 23-mer mixed-base oligomers differing by one or two bases with mass differences of 9 or 7 Da were recorded. Larger oligodeoxynucleotide segments of 34-mer, 50-mer, and 70-mer have also been analyzed effectively. Less than 250 attomol of a 10-mer DNA segment was clearly detected without any fragmentation. The new matrix can be used for the analysis of DNA segments in both positive- and negative-ion modes, and the quality of all negative-ion mode spectra are as good as that obtained in positive-ion mode shown in this paper. Compared with conventional matrices of 3-hydroxypicolinic acid (3-HPA) and 6-aza-2-thiothymine (ATT), 3-HC had noticeable improvement in resolution, S/N ratio, spot-to-spot-, and sample-to-sample reproducibility for analyzed DNA segments.  相似文献   

16.
We describe the application of silver nanoparticles (Ag NPs) as matrices for the determination of three estrogens using surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS). Because Ag NPs have extremely high absorption coefficients (1.2 x 10(8) M(-1) cm(-1)) at 337 nm, they are effective SALDI matrices when using a nitrogen laser. Three tested estrogens-estrone (E1), estradiol (E2), and estriol (E3)-adsorb weakly onto the surfaces of the Ag NPs, through van der Waals forces. After centrifugation, the concentrated analytes adsorbed on the Ag NPs were subjected directly to SALDI-MS analyses, with the limits of detection for E1, E2, and E3 being 2.23, 0.23, and 2.11 muM, respectively. The shot-to-shot and batch-to-batch variations for the three analytes were less than 9% and 13%, respectively. We validated the practicality of this present approach through the quantitation of E2 in human urine. Using this approach, we determined the concentration of E2 in a sample of a pregnant woman's urine to be 0.16 +/- 0.05 muM (n = 10).  相似文献   

17.
Quantitative analysis of partially soluble and insoluble polydisperse materials is challenging due to the lack of both appropriate standards and reliable analytical techniques. To this end, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) incorporating a solvent-free sample preparation technique was investigated for the quantitative analysis of partially soluble, polydisperse, polycyclic aromatic hydrocarbon (PAH) oligomers. Molecular weight standards consisting of narrow molecular weight dimer and trimer oligomers of the starting M-50 petroleum pitch were produced using both dense-gas/supercritical extraction (DGE/SCE) and preparative-scale, gel permeation chromatography (GPC). The validity of a MALDI-based, quantitative analysis technique using solvent-free sample preparation was first demonstrated by applying the method of standard addition to a pitch of known composition. The standard addition method was then applied to the quantitative analysis of two insoluble petroleum pitch fractions of unknown oligomeric compositions, with both the dimer and trimer compositions of these fractions being accurately determined. To our knowledge, this study represents the first successful MALDI application of solvent-free quantitative analysis to insoluble, polydisperse materials.  相似文献   

18.
A mixture of 2',4',6'-trihydroxyacetophenone in acetonitrile and aqueous triammonium citrate solution in a 1:1 molar proportion (0.2 M concentration) was found to be a good matrix for the detection of synthetic oligodeoxynucleotide samples. A high proportion of volatile solvent as well as the high salt content ensure fast co-crystallization of the matrix, co-matrix and analyte molecules. Matrix-assisted laser desorption/ionization (MALDI) mass spectra obtained in negative ion reflectron mode from samples prepared with this protocol show deprotonated molecules [M - H](-), rather than sodium adducts, as the most abundant ions even when up to 50 mM of sodium chloride is present in the sample. The matrix is shown to be effective for low mass modified single nucleotides as well as for longer oligodeoxynucleotides (up to 18mer). Post-source decay (PSD) mass spectra can also be obtained by increasing the laser fluence. Simple sequence information such as the identity and localization of a deleted base or the 5'/3' orientation can then easily be obtained. The calibration method and mass accuracy required are discussed depending on the type of information required.  相似文献   

19.
A novel method for acquisition and numerical analysis of matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectral data is described. The digitized ion current transient from each consecutive laser shot is first acquired and stored independently. Subsequently, statistical correlation parameters between all stored transients are computed. We illustrate the uses of this event-by-event analysis method for studies of sample surface heterogeneity as well as for elucidating the mechanisms of ion formation in MALDI. Other potential applications of the method are also outlined.  相似文献   

20.
The trend of miniaturization in bioanalytical chemistry is shifting from technical development to practical application. In matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), progress in miniaturizing sample spots has been driven by the needs to increase sensitivity and speed, to interface with other analytical microtechnologies, and to develop miniaturized instrumentation.We review recent developments in miniaturizing sample spots for MALDI-MS. We cover both target modification and microdispensing technologies, and we emphasize the benefits with respect to sensitivity, throughput and automation.We hope that this review will encourage further method development and application of miniaturized sample spots for MALDI-MS, so as to expand applications in analytical chemistry, protein science and molecular biology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号