首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry was investigated for the simultaneous detection of several metabolites, as applicable to global metabolite analysis (metabolomics). The commonly employed organic matrices alpha-cyano-4-hydroxycinnamic acid and 3,5-dihydroxybenzoic acid, in both the crystalline and ionic liquid forms, were investigated. The employment of a low matrix-to-analyte molar ratio suppressed matrix peaks and was effective in detecting all the metabolites with a unique mass in a 30-metabolite synthetic cocktail, albeit to varying degrees. These matrix-suppressed laser desorption/ionisation (MSLDI) analyses were performed in the positive ion mode, and metabolites were detected as the protonated [M+H]+, sodiated [M+Na]+ or potassiated [M+K]+ species. The spectral signals were dominated by basic metabolites. It was possible to detect components of a synthetic cocktail when it was spiked quantitatively into a microbial extract, demonstrating the feasibility of using the technique for detecting metabolite signals in a complex biological matrix. However, analyte suppression effects were noted when the relative proportion of one analyte was allowed to increasingly dominate the others in a mixture. The implications of the findings with respect to applications in metabolomic investigations are discussed.  相似文献   

2.
内源性代谢物是机体生命活动的中间体和终产物,对其进行定性和定量分析在生命科学研究中具有重要意义.质谱能够同时提供化合物的定性和定量信息,已经成为一种通用的内源性代谢物分析技术.由于质谱是通过检测离子质荷比获取化合物组成信息,区分生物体内复杂多样代谢物同分异构体仍然是质谱分析亟待解决的难题之一.化学衍生通过放大同分异构体...  相似文献   

3.
This work describes a novel application of capillary-flow ion chromatography mass spectrometry for metabolomic analysis, and comparison of the technique to octadecyl silica and hydrophilic interaction chromatography (HILIC)-based mass spectrometry. While liquid chromatography/mass spectrometry (LC/MS) is rapidly becoming the standard technique for metabolomic analysis, metabolomic samples are extremely heterogeneous, leading to a requirement for multiple methods of analysis and separation techniques to perform a 'global' metabolomic analysis. While C18 is suitable for hydrophobic metabolites and has been used extensively in pharmaceutical drug metabolism studies, HILIC is, in general, efficient at separating polar metabolites. Phosphorylated species and organic acids are challenging to analyse and effectively quantitate on both systems. There is therefore a requirement for an MS-compatible analytical technique that can separate negatively charged compounds, such as ion-exchange chromatography. Evaluation of capillary flow ion chromatography with electrolytic suppression was performed on a library of metabolite standards and was shown to effectively separate organic acids and sugar di- and tri-phosphates. Limits of detection for these compounds range from 0.01 to 100 pmol on-column. Application of capillary ion chromatography to a comparative analysis of energy metabolism in procyclic forms of the parasitic protozoan Trypanosoma brucei where cells were grown on glucose or proline as a carbon source was demonstrated to be more effective than HILIC for detection of the organic acids that comprise glucose central metabolism and the tricarboxylic acid (TCA) cycle.  相似文献   

4.
A liquid chromatographic method using indirect conductimetric detection is proposed for the determination of low levels of organic compounds, which does not require any special functional characteristics of the analyte. The signal detected is proportional to the molar concentration of the analyte and independent of its nature. The detector response is linearly dependent on analyte concentrations over at least three orders of magnitude. The basis of the detection is to create a conducting background, which will decrease on elution of the organic compounds. The theory of the method is discussed, with special reference to the quantitative displacement of the conducting species of the mobile phase from the column by the analyte on sample injection. The proposed method has been applied to study the chromatographic behaviour of twenty-one amino acids, where a 5 -μm Econosil CN column was used as the stationary phase with a mixture of water-acetonitrile-tetrahydrofuran (70:20:3) containing 1 mM perchloric acid or trichloroacetic acid as the mobile phase. The proposed method allows as little as 10 ng of each amino acid to be determined.  相似文献   

5.
An early assessment of metabolite exposure in preclinical species can provide quantitative estimation on possible active or toxic metabolites. Frequently, synthetic metabolite standards are not available at the preclinical stage, precluding the quantitation of metabolites by means of calibration curves and quality control (QC) samples. We present here an approach to determine the extent of circulating metabolites using 'metabolite standards' generated by in vitro incubations in combination with the correction for mass spectrometry response based on UV response. The study was done by coupling ultra-high-performance liquid chromatography (UHPLC) to LTQ-Orbitrap high-resolution mass spectrometry, and the quantitation was based on full scan high-resolution accurate mass analysis in combination with retention time. First, we investigated the separation capacity of a 10.5 min UHPLC method and the quantitative capability of an LTQ-Orbitrap for full scan accurate mass quantitation by spiking chemical standards of buspirone and its six metabolites in blank plasma. Then we demonstrated the use of a UV correction approach to quantitatively estimate buspirone and its metabolites in plasma samples from a rat pharmacokinetics study. We compared the concentration versus time profiles of buspirone and its six metabolites in rat plasma samples obtained using three different approaches, including using UV correction, using individual standard curves for each metabolite prepared from the synthetic standard, and using a calibration curve of the parent compound buspirone. We demonstrated the estimated metabolite exposure of buspirone using this UV correction approach resulted in rank ordering of metabolite exposure within three-fold of the value obtained with metabolite standards, in contrast to eight-fold without UV correction. The approach presented in this paper provides a practical solution to an unmet bioanalytical need for quantitative information on metabolites without standards in preclinical in vivo studies.  相似文献   

6.
Interferences from biological matrices remain a major challenge to the in vivo detection of drug metabolites. For the last few decades, predicted metabolite masses and fragmentation patterns have been employed to aid in the detection of drug metabolites in liquid chromatography/mass spectrometry (LC/MS) data. Here we report the application of an accurate mass-based background-subtraction approach for comprehensive detection of metabolites formed in vivo using troglitazone as an example. A novel algorithm was applied to check all ions in the spectra of control scans within a specified time window around an analyte scan for potential background subtraction from that analyte spectrum. In this way, chromatographic fluctuations between control and analyte samples were dealt with, and background and matrix-related signals could be effectively subtracted from the data of the analyte sample. Using this algorithm with a +/- 1.0 min control scan time window, a +/- 10 ppm mass error tolerance, and respective predose samples as controls, troglitazone metabolites were reliably identified in rat plasma and bile samples. Identified metabolites included those reported in the literature as well as some that had not previously been reported, including a novel sulfate conjugate in bile. In combination with mass defect filtering, this algorithm also allowed for identification of troglitazone metabolites in rat urine samples. With a generic data acquisition method and a simple algorithm that requires no presumptions of metabolite masses or fragmentation patterns, this high-resolution LC/MS-based background-subtraction approach provides an efficient alternative for comprehensive metabolite identification in complex biological matrices. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

7.
The presented work deals with the development and comprehensive validation of a quantitative LC–electrospray ionization (ESI)–tandem mass spectrometry (MS/MS) method using a triple quadrupole instrument in the MRM mode for the metabolic profiling of amino acids, organic acids, vitamins, some biogenic amines, secondary metabolites of β-lactam antibiotics biosynthesis as well as their intermediates, and degradation products in fermentation broths of β-lactam antibiotics production (in total 57 hydrophilic compounds). A great number of chromatographic systems (22 different stationary phase/mobile phase conditions) were screened for their adequate chromatographic selectivity to cope with isobaric compounds and other critical analyte pairs. Finally, a hydrophilic interaction liquid chromatography (HILIC) method employing a zwitterionic ZIC-HILIC column was selected as best compromise. Particular focus was given on the elucidation of absolute and relative matrix effects via comparison of slopes of calibration functions of spiked matrix and standard solutions. These data as well as precision and accuracy data confirm suitability of the HILIC–ESI–MS/MS assay for metabolic profiling studies in fermentation samples. Detailed comprehensive data sets are presented which should illustrate critical issues, problems, and challenges of multitarget quantitative metabolic profiling and should outline possible strategies to circumvent pitfalls and overcome common problems.  相似文献   

8.
A simple method is described for the simultaneous determination of residues of 2 carbamate herbicides (phenmedipham and desmedipham) and related metabolites (m-aminophenol, aniline, and m-toluidine) in soil. The analytes are extracted from spiked soils with methanol. The solvent/soil suspension is centrifuged, and the supernatant is directly injected, without any further cleanup, into a reversed-phase liquid chromatography/mass spectrometry apparatus equipped with a TurbolonSpray interface. The method was tested on 5 soils having different physicochemical properties. Recoveries from the soil types, spiked over the range of 50-200 ppb, were essentially quantitative for each analyte. The detection limits of the method are < or = 25 ng/g.  相似文献   

9.
1-Hydroxypyrene is a metabolite of pyrene, a member of the class of polycyclic aromatic hydrocarbons (PAHs) whose toxic properties in some cases include carcinogenicity. The determination of 1-hydroxypyrene in human urine is used as a biological indicator for exposure to PAHs, which is related to the combustion of organic materials, like smoking, living in urban environments, and eating grilled or smoked food. The determination of 1-hydroxypyrene by high-performance liquid chromatography (HPLC) with fluorescence detection has very good sensitivity but it is not highly specific: this can reduce accuracy in the quantitative determination of low levels of analyte in a complex matrix like urine. An HPLC method that uses triple quadrupole mass detection has been validated with the objective both to improve the signal-to-noise (S/N) ratio and to achieve the maximum specificity for the analyte in those urine samples that are richer in possible inteferents. The calibration range for 1-hydroxypyrene is from 0.005-0.1 microg/L in the urine of non-smoking healthy volunteers. After solid-phase extraction, samples were analyzed by HPLC/tandem mass spectrometry (MS/MS) in the multiple reaction monitoring (MRM) mode. In order to obtain reliable results quantitative analysis must be performed by means of the internal standard method (we used deuterium-labelled 1-hydroxypyrene): the method accuracy is not less than 85%. The S/N ratio at a concentration of 0.1 microg/L is about 10, and therefore this can be considered the lowest limit of quantitation. The method performance does not change if urine samples are measured using a calibration curve prepared in methanol, thus reducing the time of analysis and costs.  相似文献   

10.
A new contact-free, small droplet deposition method using an induction-based fluidics (IBF) technique to dispense nanoliter drops is described and evaluated for sample preparation in matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). The signal intensities available when using nanoliter spots are greater than those obtained with normal, microliter spots when the same amount of analyte is used. When using an ionic-liquid matrix, the improvement in sensitivity is equal to the concentration enhancement that was achieved by using smaller quantities of matrix. When using a conventional solid matrix, however, the increase in signal intensity shows a more complicated relationship to concentration. The approach of nanoliter deposition also supports multiple spotting to increase sample concentration and, thus, sample signal intensity. Nanoliter spotting not only improves the signal intensity and sensitivity achieved by MALDI-MS but also allows a major fraction of trace samples to be saved for other experiments, thus expanding the application of MALDI-MS to biological studies where sample quantity is limited.  相似文献   

11.
Laser desorption/ionization mass spectrometry (LDI-MS) on porous silicon is a promising analytical strategy for the rapid detection of metabolites in biological matrices. We show that both oxidized and unoxidized porous silicon surfaces are useful in detecting protonated/deprotonated molecules from compounds when analyzed in mixtures. We demonstrate the feasibility of using this technique for the simultaneous detection of multiple analytes using a synthetic cocktail of 30 compounds commonly associated with prokaryotic and eukaryotic primary metabolism. The predominantly detected species were the protonated molecules or their sodium/potassium adducts in the positive-ion mode and the deprotonated molecules in the negative-ion mode, as opposed to fragments or other adducts. Surface oxidation appears to influence mass spectral responses; in particular, in the mixture we studied, the signal intensities of the hydrophobic amino acids were noticeably reduced. We show that whilst quantitative changes in individual analytes can be detected, ion suppression effects interfere when analyte levels are altered significantly. However, the response of most analytes was relatively unaffected by changes in the concentration of one of the analytes, so long as it was not allowed to dominate the mixture, which may limit the dynamic range of this approach. The differences in the response of the analytes when analyzed in mixtures could not be accounted for by considering their gas-phase and aqueous basicities alone. The implications of these findings in using the technique for metabolome analyses are discussed.  相似文献   

12.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been one of the most powerful tools for analyzing protein phosphorylation. However, it is frequently difficult to detect phosphopeptides with high sensitivity by MALDI-MS. In our investigation of matrix/matrix-additive substances for improving the phosphopeptide ion response in MALDI-MS, we found that the addition of low-concentration alkylphosphonic acid to the matrix/analyte solution significantly enhanced the signal of phosphopeptides. In this study, the combination of methanediphosphonic acid and 2,5-dihydroxybenzoic acid gave the best results. In addition to enhancing the signal of the phosphopeptides, alkylphosphonic acid almost completely eliminated the signals of sodium and potassium ion adducts. We report herein sensitive detection of phosphopeptides by MALDI-MS with the use of alkylphosphonic acids as matrix additives.  相似文献   

13.
Quantitative information on drug metabolites with pharmacological or toxicological activities is of great interest during the drug discovery and development process. Because the analyte response with mass spectrometry can change significantly due to small variations in chemical structure, pure standards are required to construct standard curves for quantitation. However, for most programs at the discovery stage, pure metabolite standards are not available. In this work, an evaluation was conducted using a chemiluminescent nitrogen detector (CLND) as a calibrator to obtain the response factor ratio on a mass spectrometer generated from a metabolite and its parent compound in biological fluids. Using the response factor ratio obtained from the CLND, the metabolite could be quantified with the liquid chromatography/tandem mass spectrometry (LC/MS/MS) response obtained from the parent drug's standard curve. For this evaluation, oxazepam and temazepam were chosen as a 'drug/metabolite' pair. Temazepam was treated as the methylated metabolite of oxazepam. A spiked dog urine sample with a known concentration of oxazepam and unknown concentration of temazepam was injected onto the HPLC system and detected by both the CLND and MS/MS. Taking advantage of the equimolar response feature of the CLND, a response factor ratio between temazepam and oxazepam on the mass spectrometer was obtained by comparing the peak areas generated on the CLND and the mass spectrometer. From this ratio, temazepam was quantified using the oxazepam standard curve. The difference between the concentration of temazepam obtained from the reconstructed standard curve and the concentration obtained directly from a real temazepam standard curve was within 13% except the least concentrated standard (31%). This methodology has been successfully applied to measure quantities of the metabolite of a proprietary compound in a dog pharmacokinetic (PK) study.  相似文献   

14.
Yang L  Li H  Miao H  Zeng F  Li R  Chen H  Zhao Y  Wu Y 《色谱》2011,29(10):1010-1019
建立了动物性食品中包括代谢产物在内的54种有机磷农药残留及其代谢产物的双气相色谱-双脉冲火焰光度检测器(GC-PFPD)检测方法。动物组织样品经丙酮提取后以二氯甲烷进行液-液萃取,经凝胶渗透色谱净化后采用配有双脉冲火焰光度检测器的气相色谱仪测定。采用外标法定量,有机磷农药的响应与其浓度在线性范围内均呈良好的线性关系,相关系数在0.9905~0.9999之间。分别在空白鸡肉、羊肉、牛肉和猪肉样品中添加低、中和高3个加标水平的标准品进行了回收试验,回收率在50.5%~128.1%之间,相对标准偏差(n=6)在1.1%~25.5%之间,证明该方法的精密度和准确度良好。各有机磷农药的检出限在0.001~0.170 mg/kg之间,定量限在0.002~0.455 mg/kg之间。对从市场采集的动物组织样品进行了测定,检出敌敌畏、乙拌磷亚砜等有机磷农药残留。本方法灵敏度高、特异性强,且能同时检测有机磷农药多残留及其代谢产物,能够更加真实地反映动物性食品中有机磷农药的残留水平。  相似文献   

15.
建立了超高效液相色谱-串联质谱(UPLC-MS/MS)快速测定鸡蛋中氟虫腈及其代谢物的方法。在2 g鸡蛋中加入2 mL水后,用4 mL乙腈提取,然后加入1 g NaCl,于4℃以9000 r/min离心10 min,稀释后过有机膜。采用C18色谱柱(100 mm×2.1 mm,1.7 μm)分离,在电喷雾电离源、负离子模式下进行多反应监测(MRM)采集。结果表明,氟虫腈及其代谢物在3个添加水平下的回收率为77.4%~112.1%,相对标准偏差为4.0%~13.6%,检出限为0.10~0.43 μg/kg。该法简单、高效,可用于实际样品检测。  相似文献   

16.
During the development of a method for quantitative determination of venlafaxine and its major metabolite O-desmethylvenlafaxine, elevated concentrations of the analyte as well as co-eluting matrix compounds caused ion suppression. This ion suppression was inconsistent and therefore influenced the reproducibility of detection. The use of atmospheric pressure photoionization (APPI) in the positive mode was investigated as a tool to circumvent this problem. Employing APPI resulted in negligible ion suppression and increased linearity of the concentration range. A selective, sensitive and rapid liquid chromatography/tandem mass spectrometry method for the determination of venlafaxine and its major metabolite O-desmethylvenlafaxine in human plasma was developed. The analyte was extracted from plasma into tert-butyl methyl ether followed by back extraction into 2% formic acid. An Agilent 1100 high-performance liquid chromatography (HPLC) system, employing reversed-phase chromatography on a cyano column, coupled to an Applied Biosystems API 3000 triple quadrupole mass spectrometer set to multiple reaction monitoring (MRM) mode, was used for separation and detection of the analytes. The method was validated between 2.36-605 ng per mL with a mean recovery of approximately 88% for both parent compound and metabolite analytes. APPI technology was employed to improve the reproducibility of detection enabling rapid, selective and sensitive quantification of venlafaxine and O-desmethylvenlafaxine in human plasma samples.  相似文献   

17.
We report a novel peak sorting method for the two-dimensional gas chromatography/time-of-flight mass spectrometry (GC x GC/TOF-MS) system. The objective of peak sorting is to recognize peaks from the same metabolite occurring in different samples from thousands of peaks detected in the analytical procedure. The developed algorithm is based on the fact that the chromatographic peaks for a given analyte have similar retention times in all of the chromatograms. Raw instrument data are first processed by ChromaTOF (Leco) software to provide the peak tables. Our algorithm achieves peak sorting by utilizing the first- and second-dimension retention times in the peak tables and the mass spectra generated during the process of electron impact ionization. The algorithm searches the peak tables for the peaks generated by the same type of metabolite using several search criteria. Our software also includes options to eliminate non-target peaks from the sorting results, e.g., peaks of contaminants. The developed software package has been tested using a mixture of standard metabolites and another mixture of standard metabolites spiked into human serum. Manual validation demonstrates high accuracy of peak sorting with this algorithm.  相似文献   

18.
The current study presents a method for comprehensive untargeted metabolomic fingerprinting of the non-volatile profile of the Graciano Vitis vinifera wine variety, using liquid chromatography/electrospray ionization time of flight mass spectrometry (LC–ESI-QTOF). Pre-treatment of samples, chromatographic columns, mobile phases, elution gradients and ionization sources, were evaluated for the extraction of the maximum number of metabolites in red wine. Putative compounds were extracted from the raw data using the extraction algorithm, molecular feature extractor (MFE). For the metabolite identification the WinMet database was designed based on electronic databases and literature research and includes only the putative metabolites reported to be present in oenological matrices. The results from WinMet were compared with those in the METLIN database to evaluate how much the databases overlap for performing identifications. The reproducibility of the analysis was assessed using manual processing following replicate injections of Vitis vinifera cv. Graciano wine spiked with external standards. In the present work, 411 different metabolites in Graciano Vitis vinifera red wine were identified, including primary wine metabolites such as sugars (4%), amino acids (23%), biogenic amines (4%), fatty acids (2%), and organic acids (32%) and secondary metabolites such as phenols (27%) and esters (8%). Significant differences between varieties Tempranillo and Graciano were related to the presence of fifteen specific compounds.  相似文献   

19.
Solutions obtained by soaking onion (Allium cepa L.) bulbs samples in water are frequently consumed, either directly or as part of dishes, both at home or in the food industry. However, little information is available regarding the extracted metabolites and the extraction mechanisms. In this article, the composition of raw onion extracts and of aqueous solutions where raw onion tissues were soaked was investigated directly by quantitative proton nuclear magnetic resonance spectroscopy (q (1)H NMR). The assignment of NMR signals was performed, with less than 3% (in area) of unidentified peaks. Analyses of one-dimensional (1)H NMR spectra with additional two-dimensional NMR studies showed 20 regions of interest where 3 saccharides, 17 amino acids, and 5 organic acids were detected and quantified. Resonance assignment with chemical shift was done for each saccharide, as well as for each amino acid and organic acid, with additional work on spin-spin coupling pattern and on observed and not observed correlations from correlation spectroscopy studies. Quantification of saccharides was performed and qualified by works on peak decomposition algorithms. Complementary studies by high-performance liquid chromatography, mass spectroscopy and tandem mass spectroscopy, and thin layer chromatography and preparative layer chromatography were carried out in order to validate the NMR results on identification.  相似文献   

20.
Liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS) is a widely utilized analytical tool for quantifying small molecules in complex biological matrices. In certain situations the mass-selection capabilities of the tandem mass spectrometer may be insufficient to discriminate between the analyte of interest and its metabolites, particularly those metabolites that are isobaric with the analyte. One scenario by which isobaric interference may occur is the metabolism of a chlorine- or bromine-containing small molecule to a metabolite with the concomitant loss of 2 Da. This report describes the detection and characterization of two distinct dehydrogenation [M-2] metabolites during LC/MS/MS quantification of a chlorinated small molecule in rat plasma samples derived from a toxicokinetic study. The potential isotope-related impact of these metabolites on quantification of the parent compound was assessed. Several alternate precursor ion and product ion combinations were evaluated and shown to minimize the quantitative impact of the interfering metabolites without having to rely on their stringent chromatographic resolution from the parent compound. These results indicate that when quantifying chlorine- or bromine-containing small molecules from in vivo samples or in vitro metabolic incubations: (1) efforts to detect potential dehydrogenation metabolites should be undertaken and (2) if such metabolites are detected, the judicious choice of alternate multiple-reaction monitoring (MRM) transitions can limit their impact on quantification of the parent molecule without the need for robust chromatographic resolution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号