首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 45 毫秒
1.
A rapid, sensitive and selective high-performance liquid chromatographic method for the determination of the neuroprotectant 6-nitro-7-sulphamoylbenzo[f]quinoxaline-2,3-dione in rat plasma has been established and validated. Samples of 0.5 ml of plasma are extracted by elution from a Bond-Elut column with methanol and analysed on a reversed-phase column. The wavelength of UV detection is 254 nm. The method is linear at least up to 30 micrograms/ml, with a lowest reliable determination level of 4 mg/ml. The assays has a coefficient of variation of 13% at 10 ng/ml and 4% at 1000 ng/ml. Small variations in the extraction procedure and the liquid chromatographic conditions have minimal or no influence on the assay.  相似文献   

2.
Abstract

A high performance liquid chromatographic assay has been developed for the estimation of cyclosporine and its four major metabolites in blood and for cyclosporine alone in plasma and urine samples. This assay employs a rapid and very reproducible solid-liquid extraction system. Isocratic chromatographic conditions allow the simultaneous measurement of cyclosporine and its four major metabolites in blood. The method is linear up to 2500 ng/ml and the minimum quantifiable limit for cyclosporine is 30 ng/ml, when 1 ml of sample is analyzed.  相似文献   

3.
A liquid chromatographic method using a solid-phase extraction procedure for the quantification of sotalol in plasma and urine is described. Sotalol is eluted from an extraction column with ethyl acetate-acetonitrile (1:2) and, after separation by reversed-phase high-performance liquid chromatography on a mu Bondapak C18 column, is quantified by fluorescence detection at excitation and emission wavelengths of 240 and 310 nm, respectively. The method has been demonstrated to be linear over the concentration ranges 10-6000 ng/ml in plasma and 0.5-100 micrograms/ml in urine. Mean inter-assay accuracy of the method for plasma ranged from 93 to 100% and for urine from 102 to 114%; precision ranged from 0.5 to 1.6% for plasma over a concentration range of 200-4000 ng/ml and for urine from 0.7 to 2.0% at concentrations of 2-50 micrograms/ml. Mass spectrometry confirmed the presence of sotalol in isolated chromatographic fractions of plasma and urine extracts from subjects given sotalol orally.  相似文献   

4.
A high-performance liquid chromatographic method for the determination of disodium dihydrogen(cycloheptylamino)methylene-bisphosphonate monohydrate (YM175) in plasma, urine and bone is described. Plasma obtained in high-dose animal studies is pretreated by Method A, a simple method using 1 ml of plasma, which is based on deproteinization of plasma followed by coprecipitation of the drug with calcium phosphate and removal of excess calcium ions by AG 50W-X8 resin. Plasma obtained in lower-dose clinical studies is treated by Method B, a more sensitive method using 10 ml of plasma, which is based on solid-phase extraction using a Sep-Pak C18 cartridge coupled with Method A. Urine and bone are treated similarly to Method B. The chromatographic system consists of a mobile phase at pH 11, an alkali-stable column and an electrochemical detector operating in the oxidation mode. The determination limit is 5 ng/ml for Method A and 0.5 ng/ml for Method B in plasma, 1 ng/ml in urine, and 25 ng/g in bone.  相似文献   

5.
Clean-up and high-performance liquid chromatographic methods for the simultaneous determination of sulphadiazine and trimethoprim in fish plasma and tissues have been developed. The average recovery of sulphadiazine varied from 74% in liver to 92% in plasma, whereas that of trimethoprim varied from 60% in liver to 97% in plasma. The sample pretreatment procedures were simple, selective and robust, having a limit of quantification of 250 ng/ml for trimethoprim and 50 ng/ml for sulphadiazine in plasma, 15 ng/g for sulphadiazine and 80 ng/g for trimethoprim in muscle, and 30 ng/g for sulphadiazine and 160 ng/g for trimethoprim in liver. The assay was tested on plasma from Atlantic salmon treated with Tribrissen.  相似文献   

6.
A simple and precise high-performance liquid chromatographic procedure has been developed for the determination of temafloxacin and its trace level metabolites in biological matrices. Plasma samples are ultrafiltered after addition of an internal standard in a displacing reagent containing sodium dodecyl sulfate and acetonitrile. Plasma ultrafiltrates or diluted urines are chromatographed on a reversed-phase analytical column, using an ion-pair chromatographic mobile phase and fluorescence detection. The chromatographic system allows resolution and quantitation of temafloxacin's oxidative metabolites, which collectively account for less than 2% of the administered dose. The mean intra-assay coefficient of variation for determination of temafloxacin concentrations in plasma ranging from 0.05 to 10.0 micrograms/ml was 0.7%. The procedure was implemented at four laboratories for the analysis of over 12,000 samples from clinical studies. Inter-assay coefficients of variation estimated from routine analyses of quality control samples in these studies averaged 4% or lower for concentrations in the 0.15-10 micrograms/ml range. The limit of quantitation of the procedure is approximately 10 ng/ml; inter-assay coefficients of variation at 15 ng/ml averaged under 9%. Calibration curves were reproducible and highly linear, with correlation coefficients typically averaging over 0.9995. An alternative, more complex procedure, involving methylene chloride extraction, which extends the detection limits to below 1 ng/ml, is also described.  相似文献   

7.
For proof of the presence of chemical warfare agents sarin, soman and VX, a rapid, accurate and sensitive method which allows us to determine their hydrolysis products ethyl methylphosphonic acid, isopropyl methylphosphonic acid and pinacolyl methyl phosphonic acid was explored by using continuous flow frit fast atom bombardment (FAB) LC-MS and LC-MS-MS. After derivatization of analytes with p-bromophenacyl bromide, LC-MS-MS analyses for screening were performed by a flow injection method. The three alkyl methylphosphonic acids (AMPAs) were eluted within 5 min, and the detection limits for the three AMPAs ranged from 1 to 5 ng/ml. For confirmation of the screening results, LC-MS-MS analysis with chromatographic separation was conducted by using a narrow bore column. The three AMPAs were all eluted with excellent separation within 25 min, and the detection limits ranged from 1 to 20 ng/ml. Quantitative measurement was performed by LC-MS in selected ion monitoring (SIM) mode with chromatographic separation. Linear calibration curves were obtained for the three AMPAs and the detection limits ranged from 0.5 to 3 ng/ml. The relative standard deviation for peak area ranged from 3.4 to 6.0% at 50 ng/ml for the three AMPAs.  相似文献   

8.
The high-performance liquid chromatographic (HPLC) method was developed as a simple, reliable alternative to available methods for measuring plasma concentrations of medroxyprogesterone acetate (MPA). The HPLC method has been successfully automated and is suitable for the rapid, inexpensive analysis of large batches of plasma samples. The best approach involves a solvent extraction followed by HPLC separation and analysis. MPA can be efficiently extracted, at all pH values, by nonpolar solvents. The Spherisorb 5-ODS2 HPLC column provides excellent separation of MPA from endogenous steroids of similar structure and from extraneous plasma blank peaks. A batch of 30-40 samples can be prepared by HPLC analysis in 2-3 hours, with a chromatographic run time of 10 minutes/sample. Calibration curves between 5-250 ng/ml show a good correlation between peak height ratio and MPA concentration, even at low levels. Plasma concentrations of MPA in patients receiving 1 g/day were between 12.6-270 ng/ml in this study, suggesting that the sensitivity of this method, 10 ng/ml, is sufficient for monitoring therapeutic concentrations of MPA. The results show a wide individual variation in plasma concentrations following similar dosing schedules--a finding reported by other workers.  相似文献   

9.
Abstract

A liquid chromatographic method is described for the determination of the new fluoroquinolone Ro 23–6240 and its N-demethyl and N-oxide metabolites in plasma and urine. The three substances were extracted from aqueous solution with dichloromethane/isopropanol containing sodium dodecyl sulphate. After evaporation and reconstitution, samples were analysed on a reversed-phase column using ion pair chromatography and fluorescence detection. The limit of quantification was 10–20 ng/ml (RSD 4%) using a 0.5 ml plasma sample, and the inter assay precision was 3–10% over the concentration range 50 ng/ml to 20 μg/ml. Recovery from plasma was 81% (RSD 10%) over the range 10 ng/ml to 5 μg/ml. The method has been applied successfully to the analysis of several thousand samples from human pharmacokinetic studies. Care has to be taken to avoid exposure of samples to direct sunlight, and the use of opaque vessels for sample storage and handling is recommended.  相似文献   

10.
A gas-liquid chromatographic method for the quantitative determination of phanquone is described, based on the formation of a dimethoxine prior to its extraction from biological material. The sensitivity of the procedure is about 15 ng/ml in biological fluid.  相似文献   

11.
N-(n-Propyl)-N-(4-pyridinyl)-1H-indol-1-amine hydrochloride (HP 749, I), a non-receptor-dependent cholinomimetic agent with noradrenergic activity, is a potential agent for the treatment of Alzheimer's disease. Pharmacokinetic studies in animals and humans showed that I was well absorbed and metabolized primarily to the N-despropyl metabolite (P7480, II) after oral administration. To facilitate the kinetic studies, a sensitive and selective high-performance chromatographic assay was developed. I and II are extracted from plasma by a mixture of cyclohexane-ethyl acetate and chromatographed on an isocratic reversed-phase high-performance liquid chromatographic system employing an analytical phenyl column with acetonitrile-ammonium formate as mobile phase. The concentrations of these two compounds, quantitated by internal standardization, are monitored by ultraviolet detection. The method is linear in the plasma assay over a concentration range of 0.5-500 ng/ml for both compounds with a quantitation limit of 0.5 ng/ml. The precision and accuracy of the calibration curves and/or method are less than 10%. The recovery of I and II from plasma is 63-74 and 63-68%, respectively, over a concentration range of 0.5-500 ng/ml.  相似文献   

12.
A rapid and sensitive high-performance liquid chromatographic method is described for the quantitative analysis of dipotassium clorazepate (CZP) and its major metabolite nordiazepam (ND) in fresh human and dog plasma. The method consists of two separate selective ND extractions from a plasma sample without and with conversion of all the CZP to ND. For quantitation, diazepam (DZP) is used as the internal standard. The chromatographic phase utilized in a reversed-phase Hibar EC-RT analytical column prepacked with LiChrosolv RP-18 with a solvent system consisting of acetonitrile-0.05 M sodium acetate buffer, pH 5.0 (45:55). The UV absorbance is monitored at 225 nm using a variable-wavelength detector. The mean assay coefficient of variation over a concentration range of 20-400 ng per ml of plasma is less than 3% for the within-day precision. Recoveries of ND, DZP and CZP (as ND) are essentially quantitative at all levels investigated. The calibration curves of ND are rectilinear (r2 = 0.99) from the lower limit of sensitivity (2 ng/ml) to at least 2000 ng/ml in plasma. Applicability of the method to CZP and ND disposition studies in the anaesthetized mongrel dog is illustrated. When the two separate selective nordiazepam extractions from plasma cannot be performed immediately after blood sampling, an extrapolation kinetic method is suggested for the estimation of CZP concentration. In all previous in vivo studies, CZP has been determined only with gas-liquid chromatographic methods.  相似文献   

13.
A simple, sensitive, selective and precise liquid-column chromatographic assay for clonazepam is described, in which 1 ml of serum containing 50 micrograms/l methylclonazepam as an internal standard is extracted by elution from a Bond-Elut column with 400 microliter of methanol. An aliquot of the eluate is injected on to a reversed-phase column and eluted with a mobile phase of acetonitrile--phosphate buffer (30:70) at a flow-rate of 2 ml/min at a column temperature of 50 degrees C. Detection is at 254 nm. Chromatography is complete in 12 min. A sensitivity of 2 ng/ml is attained when 1 ml of serum is extracted. Analytical recovery of the clonazepam added to serum ranged from 91% to 99% with a coefficient of variation of 6.0%. This assay for clonazepam has good precision, with coefficients of variation of 11% at 15 ng/ml and 2.6% at 50 ng/ml. There was no interference from any of the commonly used antiepileptics.  相似文献   

14.
A rapid, sensitive and specific gas-liquid chromatographic method for the measurement of pinazepam and its metabolites in biological fluids is reported. After a single extraction of the sample with toluene, the organic phase is concentrated and, after chromatography on a 3% OV-17 column, measured with an electron-capture detector. The sensitivity was 1.0 ng/ml for pinazepam and 5.0 ng/ml for its metabolites. Plasma levels and urinary excretion in human volunteers and plasma and milk levels in women suffering from anxiety during breastfeeding are reported.  相似文献   

15.
A high-performance liquid chromatographic method for the determination of the histamine H1-receptor antagonist cetirizine in human urine was developed. Cetirizine and the internal standard are extracted from acidified (pH 5) urine (0.5 ml) into chloroform and the organic layer is evaporated to dryness. The residue is chromatographed on a Spherisorb 5ODS-2 column using Pic A (5 mM aqueous tetrabutylammonium phosphate)-methanol-tetrahydrofuran (33:65:2, v/v) as the mobile phase with ultraviolet detection (230 nm). The calibration graph is linear from 0.1 to 10 micrograms/ml and using 0.5 ml of urine the detection limit is 20 ng/ml. The within-run relative standard deviation is less than 6% and the accuracy is within 10% of the theoretical value at concentrations between 0.1 and 10 micrograms/ml in urine. There is a good correlation (r = 0.99606) with a previously described capillary gas chromatographic assay.  相似文献   

16.
《Analytical letters》2012,45(13):1657-1669
Abstract

A high performance liquid chromatographic method for the determination of tropatepine in human plasma and urines is described here. After addition of an internal standard (2 chloro-11-(4-methyl piprazine 1-yl) dibenzo (b-f)(1–4) thiazepine) to the biological fluid and extraction at pH 12.0 in hexane, the analysis was performed on a reversed phase column (C18 microBondapak) with UV detection at 231 nm. The compound was eluted by a perchlorate buffer-acetonitrile mixture with a flow rate of 1.7 ml/min. The detection limit was about 25 ng/ml; reproducibility was around 7.5% for plasma concentrations below 50 ng/ml. Mass spectrometry by direct insertion probe had validated the chromatographic results. The method was successfully applied to plasma specimen collected from a healthy human volunteer following a single intravenous administration of 20 mg of tropatepine.  相似文献   

17.
The metabolic oxidation of one of the chloroethyl groups of the antitumour drug ifosfamide leads to the formation of the inactive metabolites 2- and 3-dechloroethylifosfamide together with the neurotoxic metabolite chloroacetaldehyde. A very sensitive capillary gas chromatographic method, requiring only 50 microliters of plasma or urine, has been developed to measure the amounts of the drug and the two inactive metabolites in a single run. Calibration curves were linear (r > 0.999) in the concentration ranges from 50 ng/ml to 100 micrograms/ml in plasma and from 100 ng/ml to 1 mg/ml in urine.  相似文献   

18.
An isocratic high-performance liquid chromatographic method has been developed to allow the simple and rapid determination of both vinburnine (I) and its main metabolite, 6-hydroxyvinburnine (II), in heparinized human plasma (0.5 ml). Compounds I and II and p-chlorodisopyramide (internal standard) were first extracted with alkalinized ethyl acetate and then with sulphuric acid. Separation was achieved on a reversed-phase muBondapak C18 column with a mobile phase of acetonitrile-water-0.1 M heptanesulphonate in acetic acid and with detection at 254 nm. Each run required 20 min. The within-day coefficients of variation for identical samples (20 ng/ml) were 7 and 6% and between-day coefficients of variation 8 and 26% for I and II, respectively. The detection limit was 5 ng/ml (normal therapeutic concentration, 10-300 ng/ml). The application of the method to drug monitoring was compared to that of a thin-layer chromatographic procedure.  相似文献   

19.
《Analytical letters》2012,45(9):693-699
Abstract

A high-pressure liquid chromatographic analysis of phenylpropanolamine in plasma following extraction, back extraction and pre-column derivitization with O-phthalaldehyde is presented. The method is improved by the use of phenylethanolamine as internal standard. Using fluorescence detection, the method is sufficiently sensitive to quantitate 5 ng/ml in 0.5 ml plasma with a standard error of estimate of 2.7 ng/ml when calibrated over the O to 240 ng/ml range. Analysis of over 2000 clinical samples have shown the method to be highly specific and reliable.  相似文献   

20.
A high-performance liquid chromatographic method has been developed for the simultaneous determination of metoprolol and its alpha-hydroxylated metabolite in plasma, Metoprolol, alpha-hydroxymetoprolol and alprenolol (internal standard) are extracted from plasma at alkaline pH with diethyl ether-dichloromethane (4:1, v/v) and back-extracted with 0.01 N sulfuric acid. A 100-microliter volume of the acidic extract is injected into the chromatographic system. The compounds are eluted in about 12 min with acetonitrile-acetate buffer (75:25, v/v) on a LiChrosorb RP-8 (5 micron) column. The quantitative determinations are made fluorometrically. Concentrations down to 35 nmol/1 (10 ng/ml) of metoprolol base and 30 nmol/1 (8 ng/ml) of alpha-hydroxymetoprolol base in plasma can be determined with good precision and accuracy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号