1.
The use of a novel electrophoric derivatisation reagent, o-(pentafluorobenzyloxycarbonyl)-benzoyl chloride, for the quantitative determination of methylphenidate in plasma is described. The drug can be quantitatively measured down to 72 pg/mL plasma using only 250 μL of sample due to the extraordinary sensitivity of the derivatives under negative ion chemical ionisation mass spectrometry. Plasma samples were made alkaline with carbonate buffer and treated with extraction solvent n-hexane and reagent solution for 30 min, which, after concentration, was measured by GC-NICI-MS. The method is rapid as extraction and derivatisation occur in one single step. A stable isotope-labelled internal standard was used and its synthesis described. Full validation data are given to demonstrate the usefulness of the assay, including specificity, linearity, accuracy and precision, long-term stability, short-term stability, freeze–thaw stability, stock solution stability, autosampler stability, aliquot analysis, robustness, matrix effect, and prospective analytical batch size accuracy. The method has been successfully applied to pharmacokinetic profiling of the drug after oral application.  相似文献   

2.
Quantitative determination of amphetamine in plasma by the use of a novel electrophoric derivatization reagent, o‐(pentafluorobenzyloxycarbonyl)‐2,3,4,5‐tetrafluorobenzoyl chloride is described. Amphetamine can be quantitatively measured down to 49 pg/mL plasma using only 250 μL of sample due to the extraordinary sensitivity of the derivatives under negative ion chemical ionization MS. Plasma samples were made alkaline with carbonate buffer and treated with n‐hexane and reagent solution for 20 min, which, after concentration was measured by negative ion chemical ionization GC‐MS. The method is rapid as extraction and derivatization occur in one single step. [2H5]‐Amphetamine was used as an internal standard. Validation data are given to demonstrate the usefulness of the assay, including specificity, linearity, accuracy and precision, benchtop stability, freeze–thaw stability, autosampler stability, aliquot analysis, and prospective analytical batch size accuracy.  相似文献   

3.
The use of a novel electrophoric derivatisation reagent, o-(pentafluorobenzyloxycarbonyl)-benzoyl chloride is described for the quantitative determination of amphetamine in plasma. Amphetamine can be quantitatively measured down to 49 pg/mL plasma using only 250 μL of sample due to the extraordinary sensitivity of the derivatives under negative ion chemical ionisation mass spectrometry. Plasma samples were made alkaline with carbonate buffer and treated with n-hexane and reagent solution for 20 min, which, after concentration was measured by negative ion chemical ionisation gas chromatography-mass spectrometry. The method is rapid as extraction and derivatisation occur in one single step. [(2) H(5) ]-Amphetamine was used as an internal standard. Validation data are given to demonstrate the usefulness of the assay, including specificity, linearity, accuracy and precision, benchtop stability, freeze-thaw stability, autosampler stability, aliquot analysis and prospective analytical batch size accuracy.  相似文献   

4.
The chemical ionization mass spectrometric (CIMS) analysis of doxylamine, N,N-dimethyl-2-[1-phenyl-1-(2-pyridinyl)ethoxy]ethanamine, and related compounds, using both ammonia and methane as reagent gases, is discussed. The two reagent gases did not produce the same major fragment ion for doxylamine. Mechanisms for the fragmentation of doxylamine under either ammonia or methane CIMS conditions are proposed. The mechanisms explain the observation of an m/z 182 fragment ion for doxylamine analyzed under methane CIMS conditions and an m/z 184 product ion detected under ammonia CIMS conditions.  相似文献   

5.
In the mass spectrometry of sofosbuvir, a new orally administered antihepatitis C drug, a weak peak is detected at the m/z value of the parent ion (m/z 530) as a result of in‐source dissociation and current methods to its quantification, is based on monitoring of the parent peak using ultra high‐performance liquid chromatography with tandem mass spectrometry. With these methods serum concentration of the drug is quantifiable only up to 4–5 h postdose. However, the fragmentation of the molecule generates a more stable ion at m/z 287 (base peak) with a signal intensity of about tenfold compared to the parent ion. Our study was aimed to improve sensitivity of analysis by acquisition of the m/z value of the daughter ion from which it originated instead of the parent molecule. This novelty allows us to measure serum concentrations of the drug for a longer time postdose and provides more opportunity for pharmacokinetic studies of sofosbuvir. Our method was linear over the concentration range of 2–2560 ng/mL of sofosbuvir in human serum with a limit of quantification of 2 ng/mL compared to 10 ng/mL reported previously. The coefficient variation values of both inter and intraday analysis were less than 13.8%, and the percentage error was less than 6.3.  相似文献   

6.
This study concerns the development and validation of a complete method for the analysis of two highly reactive α-dicarbonyl compounds, glyoxal (Gly) and methylglyoxal (Mgly), in atmospheric fine particulate matter (PM2.5). Method development included optimization of sample preparation procedures, e.g., filter extraction, concentration of extracts, derivatization and solid-phase extraction (SPE) of derivatives, as well as reversed-phase liquid chromatography coupled to electrospray ion-trap mass spectrometry (HPLC-ESI-IT/MS/MS) measurement parameters. Selectivity of detection was enhanced using tandem mass spectrometric analysis in ESI positive ion mode via two multiple reaction monitoring channels, m/z 433 → m/z 250 and m/z 419 → m/z 236 for Mgly and Gly. Retention times were 9.5 and 12.5 min for Gly- and Mgly-bis-hydrazone derivatives. Calibration ranged from 0.5 to 50 ng/mL. Inter-batch precision, expressed as relative standard deviation, was <15%. The method was shown to be unaffected by the sample matrix and to have recoveries of 100% and 60% for Gly and Mgly, respectively. Improved instrumental detection limits of 0.51 and 0.62 ng/mL for Gly and Mgly were achieved using a SPE method for the purification of 2,4-dinitrophenylhydrazine derivatization reagent solutions. This permitted the method to be used for analysis of filter samples obtained during a field study at the Taunus Observatory (mount Kleiner Feldberg, Germany). PM2.5 concentrations ranged from 0.81 to 1.18 ng/m3 for Gly and from 0.83 to 1.92 ng/m3 for Mgly. PM concentrations correlated to the concentration of NO with coefficients (R 2) of 0.67 (Gly) and 0.78 (Mgly).  相似文献   

7.
A liquid chromatographic mass spectrometric assay for the quantification of azithromycin in human plasma was developed. Azithromycin and imipramine (as internal standard, IS) were extracted from 0.5 mL human plasma using extraction with diethyl ether under alkaline conditions. Chromatographic separation of drug and IS was performed using a C18 column at room temperature. A mobile phase consisting of methanol, water, ammonium hydroxide and ammonium acetate was pumped at 0.2 mL/min. The mass spectrometer was operated in positive ion mode and selected ion recording acquisition mode. The ions utilized for quantification of azithromycin and IS were m/z 749.6 (M + H) + and m/z 591.4 (fragment) for azithromycin, and 281.1 m/z for internal standard; retention times were 6.9 and 3.4 min, respectively. The calibration curves were linear (r2 > 0.999) in the concentration ranges of 10–1000 ng/mL. The mean absolute recoveries for 50 and 500 ng/mL azithromycin and 1 µg/ mL IS were >75%. The percentage coefficient of variation and mean error were <11%. Based on validation data, the lower limit of quantification was 10 ng/mL. The present method was successfully applied to determine azithromycin pharmacokinetic parameters in two obese volunteers. The assay had applicability for use in pharmacokinetic studies. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
The synthesis of a novel electrophoric derivatisation reagent, o-(pentafluorobenzyloxycarbonyl)benzoyl chloride, is described. The reagent was tested against selected primary and secondary amino compounds as analytical targets. The derivatives exhibit excellent mass spectral properties under negative ion chemical ionisation (NICI), i.e. reduced fragmentation and thus high ion current for the targeted m/z during analysis. Since the reagent bears a pentafluorobenzyl ester group, resulting mass NICI mass spectra were expectedly dominated by dissociative resonance electron capture typically observed with these compounds. The reagent is suitable for detecting volatile primary and secondary amines with high sensitivity. Background is reduced by a shift in detected m/z and retention time, as demonstrated for the analysis of the drug methylphenidate from human plasma.  相似文献   

9.
A rapid and validated method for analysis of levosulpiride in human plasma using liquid chromatography coupled to tandem mass spectrometry was developed. Levosulpiride and tiapride (IS, internal standard) were extracted from alkalized plasma samples with ethylacetate and separation by RP‐HPLC. Detection was performed by positive ion electrospray ionization in multiple‐reaction monitoring mode, monitoring the transitions m/z 342.1 → m/z 112.2 and m/z 329.1 → m/z 213.2, for quantification of levosulpiride and IS, respectively. The standard calibration curves showed good linearity within the range of 2–200 ng/mL (r2 ≥ 0.9990). The lower limit of quantitation was 2 ng/mL. The retention times of levosulpiride (0.63 min) and IS (0.66 min) presented a significant time saving benefit of the proposed method. No significant metabolic compounds were found to interfere with the analysis. This method offered good precision and accuracy and was successfully applied for the pharmacokinetic and bioequivalence study of a 25 mg of levosulpiride tablet in 24 healthy Korean volunteers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
An accurate and sensitive LC–MS/MS method for determining thalidomide, 5‐hydroxy thalidomide and 5′‐hydroxy thalidomide in human plasma was developed and validated using umbelliferone as an internal standard. The analytes were extracted from plasma (100 μL) by liquid–liquid extraction with ethyl acetate and then separated on a BETASIL C18 column (4.6 × 150 mm, 5 μm) with mobile phase composed of methanol–water containing 0.1% formic acid (70:30, v/v) in isocratic mode at a flow rate of 0.5 mL/min. The detection was performed using an API triple quadrupole mass spectrometer in atmospheric pressure chemical ionization mode. The precursor‐to‐product ion transitions m/z 259.1 → 186.1 for thalidomide, m/z 273.2 → 161.3 for 5‐hydroxy thalidomide, m/z 273.2 → 146.1 for 5′‐hydroxy thalidomide and m/z 163.1 → 107.1 for umbelliferone (internal standard, IS) were used for quantification. The calibration curves were obtained in the concentrations of 10.0–2000.0 ng/mL for thalidomide, 0.2–50.0 ng/mL for 5‐hydroxy thalidomide and 1.0–200.0 ng/mL for 5′‐hydroxy thalidomide. The method was validated with respect to linear, within‐ and between‐batch precision and accuracy, extraction recovery, matrix effect and stability. Then it was successfully applied to estimate the concentration of thalidomide, 5‐hydroxy thalidomide and 5′‐hydroxy thalidomide in plasma samples collected from Crohn's disease patients after a single oral administration of thalidomide 100 mg.  相似文献   

11.
The methane and isobutane chemical ionization mass spectra of alicyclic substituted 2-aryl-1,3-dithianes were examined by gas chromatography mass spectrometry. The protonated molecular ion was found to be of low abundance in the methane spectra, while a protonated cyclic sulfide cation (m/z 107) appeared as the base peak. A protonated molecular ion was the base peak when isobutane was used as the reagent gas. Electron impact mass spectra displayed weak molecular ions and were characterized by the m/z 106 fragment.  相似文献   

12.
A simple, rapid and sensitive method has been developed and validated for the determination of pramipexole in rat plasma by using gas chromatography mass spectrometry. The lower limit of quantification (LLOQ) is superior to the other reported LC‐MS/MS methods. After being made alkaline with NaOH, plasma samples (0.1 mL) were subjected to liquid–liquid exteraction using methyl‐t‐butyl ether. Analytes were determined using electron impact ionization in a single quadrupole mass spectrometer. GC/MS was performed in the selected ion monitoring mode using target ions at m/z 211, 212 and 152 for pramipexole and m/z 194 and 165 for caffeine as internal standard. A linear calibration curve was plotted over the range of 20–1000 pg/mL for pramipexole (r2 > 0.996). The LLOQ was 20.0 pg/mL, respectively, which offered high sensitivity and selectivity enough for bioanalytical investigation. Inter‐ and intraday precisions ranged from 0.3 to 8.8% and from 0.9 to 11.33%, respectively. The recovery of pramipexole from plasma ranged from 82.4 ± 7.1 to 87.8 ± 5.7%. The method fulfills all standards required for bioanalytical methods and can be successfully applied to a pharmacokinetic study of pramipexole in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
Further studies have demonstrated that the site-specific hydrogen transfer process involved in the formation of the m/z 145 anion of β-hydroxyamine pentafluoropropionate (PFP) derivatives observed under electron capture negative ion chemical ionization conditions occurs when the two functional groups are separated by up to five carbon atoms. Deuterium labelling has established that the site specificity, transfer of a hydrogen atom from the carbon adjacent to nitrogen to the OPFP group, is maintained in 4-amino-butan-1-ol-N, O-(PFP)2. The corresponding PFP derivatives of the N-methylaminoalkanol-(PFP)2 derivatives lack the m/z 145 species with m/z 163, [OPFP]? being the base anion. Substitution of alkyl groups on the carbon adjacent to oxygen results in a diminution of the ion intensity at m/z 145. with a marked increase in the intensity of m/z 144. The formation of the m/z 145 and 144 anions to proposed to proceed through the intervention of a fluoride ion-molecule complex as outlined in Scheme 1 with the product ion distribution dependent on which of the two pathways is preferred.  相似文献   

14.
A selective, sensitive and rapid ultra‐performance liquid chromatography tandem mass spectrometry method was developed and validated for the simultaneous determination of etonogestrel (ENG) and ethinyl estradiol (EE) in human plasma. The analytes and their deuterated internal standards, ENG‐d7 and EE‐d4, were extracted from plasma samples by solid‐phase extraction on HyperSep™ Retain PEP cartridges. The chromatographic analysis was performed on an Acquity UPLC HSS Cyano column, 100 Å (50 × 2.1 mm, 1.8 μm), column using gradient mobile phase, acetonitrile and 2.0 mm ammonium trifluoroacetate at 0–1.7 min (65:35, v/v) and 1.8–2.7 min (95:5, v/v) with 0.250 mL/min flow rate. Analytes and IS protonated precursor → product ion transitions (ENG, m/z 325.2 → 257.2; EE, m/z 530.2 → 171.2; ENG‐d7, m/z 332.2 → 263.2; EE‐d4, m/z 534.2 → 171.2) were monitored on a Triple Quadrupole Mass spectrometer (TQMS), operating in multiple reaction monitoring and positive ionization mode. The calibration curves were established at 10.00–2500 pg/mL for ENG and 1.500–150.0 pg/mL for EE with a correlation coefficient (r2) ≥0.9996 for both. The validated method was successfully applied to support a bioequivalence study of 0.15 mg ENG and EE 0.03 mg tablet formulation, administered in 24 healthy Indian females. Method reliability was assessed by reanalysis of 94 incurred study samples.  相似文献   

15.
The vaginal administration route suffers from relatively low absorption efficiency, which may hinder the identification of the toxicokinetics of curdione in pregnant women. A sensitive analytical method for determining the plasma concentration of curdione was developed and applied in the determination of curdione in pregnant Sprague–Dawley rats as a simulated model. Glimepiride was used as an internal standard and chromatographic separation was achieved on a Capcell Pak C18 MGIII column. A gradient elution profile with 0.5% formic acid (A)–0.5% formic acid–acetonitrile (B) was selected as mobile phase. The selected reaction monitoring mode was used for quantification based on the target fragment ions m/z 237.2 to m/z 135.1 for curdione and m/z 491.3 to m/z 352.1 for the glimepiride. The standard curve was linear over the range of 0.5–500 ng/mL for curdione in rat plasma and yielded a consistent peak pattern, even at the lower limit of quantitation of 0.5 ng/mL. The retention times of curdione and IS were 6.55 and 6.59 min, respectively. The mean recovery of curdione in rat plasma was 95.5–101.1%. The intra‐day and inter‐day precisions were between 2.35 and 9.08%. This LC‐MS/MS method provides a simple and sensitive means for determining the plasma concentration. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
Nitazoxanide (NTZ) is a broad‐spectrum antimicrobial agent. Tizoxanide (T) and tizoxanide glucuronide (TG) are the major circulating metabolites after oral administration of NTZ. A rapid and specific LC–MS/MS method for the simultaneous quantification of T and TG in mouse plasma was developed and validated. A simple acetonitrile‐induced protein precipitation method was employed to extract two analytes and the internal standard glipizide from 50 μL of mouse plasma. The purified samples were resolved using a C18 column with a mobile phase consisting of acetonitrile and 5 mm ammonium formate buffer (containing 0.05% formic acid) following a gradient elution. An API 3000 triple quadrupole mass spectrometer was operated under multiple reaction‐monitoring mode with electrospray ionization. The precursor‐to‐product ion transitions m/z 264 → m/z 217 for T and m/z 440 → m/z 264 for TG were used for quantification. The developed method was linear in the concentration ranges of 1.0–500.0 ng/mL for T and 5.0–1000.0 ng/mL for TG. The intra‐ and inter‐day precision and accuracy of the quality control samples at low, medium and high concentrations exhibited an RSD of <13.2% and the accuracy values ranged from ?9.6 to 9.3%. We used this validated method to study the pharmacokinetics of T and TG in mice following oral administration of NTZ. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

17.
Association of carbonyl compounds with protons to give cluster ions can be observed in conventional chemical ionization mass spectrometry. The variation of the relative ion currents of proton bound ‘dimers’ formed with acetone and methylethyl ketone have been examined as a function of ion source partial pressures. Multiple ion/molecule reactions with N-methylol derivatives of amides and carbamates and repetitive losses of water give protonated oligomeric species. Ions having m/z values as large as 625 [M6H? 5H2O]+ have been detected in the chemical ionization spectrum of N-hydroxymethylurethane (M).  相似文献   

18.
This study describes a method for the screening of methylenedioxyamphetamine‐ and piperazine‐derived compounds in urine by liquid chromatography‐tandem mass spectrometry. These substances, characterized by possessing common moieties, are screened using precursor ion and neutral loss scan mode and then quantified in multiple reaction monitoring acquisition mode. Based on the product‐ion spectra of different known molecules, chosen as ‘model’, characteristic neutral losses and product ions were selected: piperazines were detected in precursor ion scan of m/z 44 and neutral loss of 43 and 86 while amphetamines in precursor ion scan of m/z 133, 135 and 163. The applicability of the screening approach was studied in blank urine spiked with selected analytes and processed by solid‐phase extraction. Linearity, matrix effect, precision, accuracy, limits of detection and limits of quantification were evaluated both for the screening and the quantification methods. The ability of the screening method to provide semi‐quantitative data was demonstrated. This method appears to be a useful tool for the identification of designer drugs derived from piperazines or methylenedioxyamphetamines and can be potentially applied to other drug classes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
Plasmatic chlorophacinone is commonly measured with liquid chromatographic assay, which convenient but lacks sensitivity and selectivity and usually requires ion pair reagents to reduce the chromatographic tailed peak. In this paper, a novel method using eluent generator reagent‐free ion chromatography coupled with electrospray ionization ion trap mass spectrometric detection for the determination of chlorophacinone in plasma has been developed. After samples were extracted with 10% (v/v) methanol in acetonitrile and cleaned by solid‐phase extraction, chromatographic separation was performed on an IonPac® AS11 analytical column (250 × 4.0 mm) using 40.0 mmol/L KOH containing 10% (v/v) methanol as organic modifier. Quantification was performed by negative electrospray ionization in multiple reaction monitoring mode. The transition m/z 373 → 201 was for the quantification ion; the transitions m/z 373 → 172 and m/z 373 → 145, as well as the isotope ions m/z 375 and m/z 203, were for the qualitative ions. All the method parameters were validated. It was confirmed that this method can be used in clinical diagnosis and forensic toxicology. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
A sensitive and selective liquid chromatography mass spectrometry method for determination of chidamide in rat plasma was developed. After addition of linezolid as internal standard, protein precipitation by acetonitrile–methanol (9:1, v/v) was used as sample preparation. Chromatographic separation was achieved on a Zorbax SB‐C18 (2.1 × 150 mm, 5 µm) column with acetonitrile–0.1% formic acid as mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; selective ion monitoring mode was used for quantification using target fragment ions m/z 391.5 for chidamide and m/z 338.5 for the IS. Calibration plots were linear over the range of 10–2000 ng/mL for chidamide in rat plasma. The lower limit of quantification for chidamide was 10 ng/mL. The mean recovery of chidamide in plasma was in the range of 86.6–92.1%. The coefficients of variation of intra‐day and inter‐day precision were both <12%. This method is simple and sensitive and was applied successfully in a pharmacokinetic study of chidamide to rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   