首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Selected agrochemicals (s-triazines and phenoxy acids) have been investigated with partial-filling micellar electrokinetic chromatography (PFMEKC) and non-aqueous capillary electrophoresis (NACE). Because these two techniques are compatible for coupling of capillary electrophoresis with mass spectrometry, different conditions affecting the separation efficiency (reproducibility, method linearity) were systematically tested, and the results were compared with those from classical MEKC. The conditions tested included buffer molarity, pH, the concentrations of the organic modifier and surfactant, the applied voltage, the injection time of the sample, and the length of the partial-filling plug. The respective limits of detection (LOD) using UV-detection were determined. Reduction of the electrophoretic raw data using the mobility scale transformation (micro-scale) improved qualitative comparison of the electropherograms and the reproducibility of quantitative data (integrated peak area) thus extending this data treatment from CZE to other endoosmotic flow-driven CE-techniques such as PFMEKC and NACE.  相似文献   

2.
Capillary electrophoresis with postcolumn laser-induced fluorescence detection was used to individually detect 6.0, 1.0, 0.5, and 0.2 num diameter polystyrene microspheres and individually measure their electrophoretic mobility. The analysis of a nanoliter-size volume from a microsphere suspension results in an electropherogram characterized by several narrow spikes in a well-defined migration time window. Each spike is associated with one microsphere because, when one single microsphere is introduced into the capillary by micromanipulation, the electropherogram has only one spike in the same migration time window. The distributions of individual measurements resulting from an electropherogram were used to evaluate the reproducibility from run to run, observe the effect of sodium dodecyl sulfate (SDS) added to the running buffer, and to investigate the origin of electrophoretic dispersion. As expected from the interactions between microspheres and SDS, the addition of this surfactant to the running buffer narrowed the range and shifted the average electrophoretic mobility to more negative values. After evaluating common sources of broadening in capillary electrophoresis, electrophoretic dispersion was attributed to microsphere heterogeneity. Unlike electropherograms displaying Gaussian-like profiles, the two-dimensional representations of the individual measurements provide a new alternative to evaluate and study electrophoretic-related properties of microspheres.  相似文献   

3.
Method development approaches for capillary ion electrophoresis   总被引:1,自引:0,他引:1  
Capillary ion electrophoresis (CIE) is a capillary electrophoretic technique optimized for rapid determination of low-molecular-mass inorganic and organic ions. CIE predominantly employs indirect UV detection since the majority of the analytes lack specific chromophores. Described are three methods for detection and electrolyte optimization. The first method discussed approaches for optimizing sensitivity, selectivity and peak confirmation using a chromate electrolyte and selected detection wavelengths. Peak confirmation is aided by using both direct detection of analytes. The second and third methods involve an unattended electrolyte development approach for instruments that only provide fresh electrolyte on the injection side of the capillary. The electrolyte composition is changed in both the injection side vial and in capillary before each sample injection while leaving the receiving side electrolyte vial constant at the initial electrolyte composition. In one mode, the concentration of the electroosmotic flow (EOF) modifier used to induce anodic flow is varied while keeping the background electrolyte composition constant. In a second experiment, the background electrolyte co-ion is sequentially changed from high mobility to low mobility while keeping the EOF modifier concentration constant. The end effect is to achieve a broad range of controlled peak symmetry for analytes in a simple matrix. The results are compared to separations obtained when the injection side and receiving side electrolytes are manually matched.  相似文献   

4.
It is demonstrated that the use of pressure extends the possibilities of capillary zone electrophoresis in studying aggregative states of substances, ensuring the detection of the presence of several types of aggregates with different electrophoretic mobilities. The electropherograms of chitosan 2-hydroxybutoxypropylcarbamate (CHBPC) in citrate solutions with pH 3.1, 4.5, and 5.8 indicate the dependence of aggregation on pH. A comparison of the data for CHBPC obtained by capillary zone electrophoresis, static light scattering, and scanning electron microscopy revealed a relationship between the electrophoretic mobility and sizes of aggregates, varying from 140 nm to several micrometers. The size of aggregates can be estimated by hydrodynamic contribution to their mobility. The effectiveness of the use of CHBPC for the dynamic modification of capillaries is shown.  相似文献   

5.
Our dynamic capillary electrophoresis model which uses material specific input data for estimation of electroosmosis was applied to investigate fundamental aspects of isoelectric focusing (IEF) in capillaries or microchannels made from bare fused-silica (FS), FS coated with a sulfonated polymer, polymethylmethacrylate (PMMA) and poly(dimethylsiloxane) (PDMS). Input data were generated via determination of the electroosmotic flow (EOF) using buffers with varying pH and ionic strength. Two models are distinguished, one that neglects changes of ionic strength and one that includes the dependence between electroosmotic mobility and ionic strength. For each configuration, the models provide insight into the magnitude and dynamics of electroosmosis. The contribution of each electrophoretic zone to the net EOF is thereby visualized and the amount of EOF required for the detection of the zone structures at a particular location along the capillary, including at its end for MS detection, is predicted. For bare FS, PDMS and PMMA, simulations reveal that EOF is decreasing with time and that the entire IEF process is characterized by the asymptotic formation of a stationary steady-state zone configuration in which electrophoretic transport and electroosmotic zone displacement are opposite and of equal magnitude. The location of immobilization of the boundary between anolyte and most acidic carrier ampholyte is dependent on EOF, i.e. capillary material and anolyte. Overall time intervals for reaching this state in microchannels produced by PDMS and PMMA are predicted to be similar and about twice as long compared to uncoated FS. Additional mobilization for the detection of the entire pH gradient at the capillary end is required. Using concomitant electrophoretic mobilization with an acid as coanion in the catholyte is shown to provide sufficient additional cathodic transport for that purpose. FS capillaries dynamically double coated with polybrene and poly(vinylsulfonate) are predicted to provide sufficient electroosmotic pumping for detection of the entire IEF gradient at the cathodic column end.  相似文献   

6.
The analysis of mitochondria by capillary electrophoresis usually takes longer than 20 min per replicate which may compromise the quality of the mitochondria due to degradation. In addition, low sample consumption may be beneficial in the analysis of rare or difficult samples. In this report, we demonstrate the ability to analyze individual mitochondrial events in picoliter-volume samples (approximately 80 pL) taken from a bovine liver preparation using microchip capillary electrophoresis with laser-induced fluorescence detection (micro-chip CE-LIF). Using a commercial "double-T" glass microchip, the sample was electrokinetically loaded in the "double-T" intersection and then subjected to electrophoretic separation along the main separation channel. In order to decrease interactions of mitochondria with channel walls during the analysis, poly(vinyl alcohol) was used as a dynamic coating. This procedure eliminates the need for complicated covalent surface modifications within the channels that were previously used in capillary electrophoresis methods. For analysis, mitochondria, isolated from bovine liver tissue, were selectively labelled using 10-nonyl acridine orange (NAO). The results consist of electropherograms where each mitochondrial event is a narrow spike (240 +/- 44 ms). While the spike intensity is representative of its NAO content, its migration time is used to calculate and describe its electrophoretic mobility, which is a property still largely unexplored for intracellular organelles. The five-fold decrease in separation time (4 min for microchip versus 20 min for capillary electrophoresis) makes microchip electrophoretic separations of organelles a faster, sensitive, low-sample volume alternative for the characterization of individual organelle properties and for investigations of subcellular heterogeneity.  相似文献   

7.
Dynamic computer simulation data are compared for the first time with CE data obtained with a laboratory made system comprising an array of 8 contactless conductivity detectors (C4Ds). The experimental setup featured a 50 μm id linear polyacrylamide (LPA) coated fused‐silica capillary of 70 cm length and a purpose built sequential injection analysis manifold for fluid handling of continuous or discontinuous buffer configurations and sample injection. The LPA coated capillary exhibits a low EOF and the manifold allows the placement of the first detector at about 2.7 cm from the sample inlet. Agreement of simulated electropherograms with experimental data was obtained for the migration and separation of cationic and anionic analyte and system zones in CZE configurations in which EOF and other column properties are constant. For configurations with discontinuous buffer systems, including ITP, experimental data obtained with the array detector revealed that the EOF is not constant. Comparison of simulation and experimental data of ITP systems provided the insight that the EOF can be estimated with an ionic strength dependent model similar to that previously used to describe EOF in fused‐silica capillaries dynamically double coated with Polybrene and poly(vinylsulfonate). For the LPA coated capillaries, the electroosmotic mobility was determined to be 17‐fold smaller compared to the case with the charged double coating. Simulation and array detection provide means for quickly investigating electrophoretic transport and separation properties. Without realistic input parameters, modeling alone is not providing data that match CE results.  相似文献   

8.
We have plotted electropherograms in capillary zone electrophoresis (CZE) as a function of the quantity of electric charge (Q) in order to eliminate the dependency of the analyte peak areas, as well as that of the migration times, upon both the capillary temperature and the applied voltage. The procedure is based on an idea of a migration index (MI) and an adjusted migration index (AMI) which were originally proposed by Lee and Yeung. The value of Q is measured accurately and calculated easily because it is given by a product of the electrophoretic current and the migration times, where the index MI is derived by dividing the value of Q by the effective volume of the capillary. By calculating the CZE peak area from the newly plotted electropherogram, improvement in precision in quantitative analysis is expected. Concerning AMI, careful treatment is required in its application to analyte peaks whose migration time is close to that of the neutral marker. Experimental data and discussions concerning the migration indices are presented.  相似文献   

9.
氨基酸的毛细管电泳分离及激光干涉检测的研究   总被引:2,自引:0,他引:2  
任吉存  邓延倬 《分析化学》1995,23(6):644-647
  相似文献   

10.
A hydrophilic polymer, poly(vinylpyrrolidone) (PVP), was employed for suppressing the electroosmotic flow (EOF). A capillary was filled with aqueous PVP solution for coating the capillary wall with PVP; the PVP solution was then replaced by a migration buffer solution containing no PVP. Three types of PVP with different molecular weights were examined. The EOF was suppressed more effectively as the molecular weight of PVP increased. The EOF in the coated capillary was approximately 10-fold smaller than that of a bare capillary and was constant in the pH range of 6-8. The suppressed EOF was stable even when no PVP was added to the migration buffer. However, the EOF increased significantly when sodium dodecyl sulfate was added into the migration buffer. The method was applied for determining the electrophoretic mobilities of inorganic anions that have negative electrophoretic mobilities larger than the electroosmotic mobility of the bare capillary. A novel method for determining the electrophoretic mobilities was proposed based on the linear relationship between electric current and electrophoretic mobility. The electrophoretic mobility was proportional to the electric current. Therefore, the intercept of the regression equation represents the electrophoretic mobility at room temperature. The electrophoretic mobilities were in good agreement with the absolute electrophoretic mobilities.  相似文献   

11.
The migration process in capillary electrophoresis is obtained by using a high-voltage power supply, and the basic idea is to keep the control on the migration velocity of the analytes by controlling either the applied voltage or current. The effectiveness of this control has impact on the resulting electropherogram and, thus, in the identification and quantification of the analytes. Although the usual electropherogram is the record of the detector signal as a function of time, other two domains should be considered: charge and mobility. Both mathematical modeling and experimental results were used to evaluate the two different approaches for controlling the electrophoretic migration and the resulting time-, charge-, and mobility-based electropherograms. The main conclusions are (1) the current-controlled mode is superior to the voltage-controlled mode; (2) when the first mode cannot be implemented, the electrophoretic current should be monitored to improve the identification and quantification procedures; and (3) the consistent monitoring of the electrophoretic current allows the implementation of the charge-based electropherogram and the mobility spectrum. The first one is advantageous because the peak position is more reproducible, and the peak area is more resistant to change than the ones from the time-based electropherogram. The mobility spectrum has the additional advantage of being more informative about the mobility of the analytes. Although peak area is less robust, the spectrum may also be used for quantitation when the number of plates is greater than 103.  相似文献   

12.
We studied system peaks present in the electropherograms obtained in the separation of anions by capillary electrophoresis with indirect spectrophotometric detection and cathode electroosmotic flow (EOF) with a chromate background electrolyte. The system peaks correspond to the zones with changed concentration of the background electrolyte; they formed when the zones of each analyte passed through the outlet of the capillary and then moved towards the EOF detector. It has been revealed that the height and area of the system peaks linearly depends on the concentration of the corresponding anion and the areas of the system peaks can achieve 10% of the anion peak area. An algorithm has been proposed for the determination of the optimal conditions for anion separation using hydrodynamic pressure for the regulation of the EOF flow rate. This algorithm prevents the overlapping of the anion and system peaks.  相似文献   

13.
The application of the combination of experimental design (ED) and artificial neural networks (ANNs) for the quantification of overlapped peaks in capillary zone electrophoresis is described. When the total separation cannot be achieved by separation techniques, the use of ED-ANN can be a suitable approach. The unstability of EOF causes peak shift that has to be corrected in order to apply ED-ANN methods. In this work, normalization procedure of electropherograms with consequent application of ANNs for quantification purpose was developed. Both, spectra and electropherograms can be used as multivariate data. In general, both kinds of data were found to be suitable for unresolved peaks quantification by ED-ANN approach.  相似文献   

14.
We present an experimental study of the effect of pH, ionic strength, and concentrations of the electroosmotic flow (EOF)-suppressing polymer polyvinylpyrrolidone (PVP) on the electrophoretic mobilities of commonly used fluorescent dyes (fluorescein, Rhodamine 6G, and Alexa Fluor 488). We performed on-chip capillary zone electrophoresis experiments to directly quantify the effective electrophoretic mobility. We use Rhodamine B as a fluorescent neutral marker (to quantify EOF) and CCD detection. We also report relevant acid dissociation constants and analyte diffusivities based on our absolute estimate (as per Nernst-Einstein diffusion). We perform well-controlled experiments in a pH range of 3-11 and ionic strengths ranging from 30 to 90 mM. We account for the influence of ionic strength on the electrophoretic transport of sample analytes through the Onsager and Fuoss theory extended for finite radii ions to obtain the absolute mobility of the fluorophores. Lastly, we briefly explore the effect of PVP on adsorption-desorption dynamics of all three analytes, with particular attention to cationic R6G.  相似文献   

15.
Phthalate buffers are currently used in capillary electrophoresis as robust electrolyte systems for indirect detection. This contribution demonstrates that these buffers show regularly not only successful regions of mobilities of analytes (sample window) but also regions of failure where the migration of analytes is strongly deteriorated due to the presence of a system zone. System zones in phthalate buffers may be easily detected by UV detection and manifest themselves as peaks or dips. Peak shape diagrams are advantageously used for the prediction of the migration behavior of system zones in phthalate background electrolyte (BGE) systems at various pH. It is shown that the mobility of the system zone varies strongly with pH, is practically zero at pH values below 4 and above 7, and shows a maximum at pH 5. Thus, the system peak may coincide either with the peaks of various analytes or with the electroosmotic flow (EOF) peak. Experiments are given showing the effects of such coincidences as, e.g., zigzag detection patterns, double EOF peaks, and/or unusually broad peaks/dips. The message of this contribution is to show how to understand the electrophoretic properties of phthalate BGEs that, regardless of possible failure regions, may be successfully used in the analytical practice of capillary zone electrophoresis (CZE).  相似文献   

16.
The influence of separation conditions on peak broadening is usually estimated by the number of theoretical plates. Using the data available in literature and experimental data, it is shown that in pressure‐assisted capillary electrophoresis the plate number is not directly related to the separation capability of conditions used. The experiments at different electrolyte flow velocities demonstrate that a higher plate number (the best separation efficiency) can be obtained with a lower peak resolution. Since ions are separated by electrophoresis due to the difference in electrophoretic mobilities, the peak width in terms of electrophoretic mobility is suggested as a new peak broadening parameter describing the separation capability of the conditions used. The parameter can be calculated using the tailing factor and the temporal peak width at 5% of the peak height. A simple equation for the resolution calculation is derived using the parameter. The advantage of the peak width in terms of mobility over other parameters is shown. The new parameter is recommended to be used not only in pressure‐assisted capillary electrophoresis but also in general capillary electrophoresis when in a number of runs the virtual separative migration distance and separation capability of the conditions used change widely.  相似文献   

17.
Hartzell B  McCord B 《Electrophoresis》2005,26(6):1046-1056
Divalent metal ions, such as Zn(2+), Co(2+), and Ni(2+), are capable of incorporating into DNA under certain conditions to form complexes termed M-DNA. To better understand the effects of these cations on DNA we used capillary electrophoresis (CE). The presence of these metal ions in a typical genotyping buffer led to broad peaks with low fluorescence intensities. In addition, some of the metal-complexed DNA molecules had different electrophoretic mobilities than their normal DNA counterparts. It is likely that the mobility shifts observed in the electropherograms of these affected fragments are due to the divalent cations causing structural changes in the single-stranded DNA. However, as can be seen from the resulting peak shapes, the structure, charge, and/or mass changes due to metal binding are not conserved among all of the DNA fragments. The extent of both peak-broadening and mobility shifts were found to be dependent on the metal cation and its concentration, the length of time that the DNA sample existed in formamide prior to injection into the capillary, and also the fragment size and sequence. These results suggest that the presence of metal ions might be responsible for the poor CE performance that occurs when genotyping certain kinds of DNA samples.  相似文献   

18.
Zhu Z  Zhang L  Marimuthu A  Yang Z 《Electrophoresis》2002,23(17):2880-2887
A simple, quick, and sensitive capillary electrophoretic technique-large volume stacking using the electroosmotic flow (EOF) pump (LVSEP) - has been developed for determining ethylenediaminetetraacetic acid (EDTA) in drinking water for the first time. It is based on a precapillary complexation of EDTA with Fe(III) ions, followed by large-volume sample stacking and direct UV detection at 258 nm. The curve of peak response versus concentration was linear from 5.0 to 600.0 microg/L, and 0.7 to 30.0 mg/L. The regression coefficients were 0.9988 and 0.9990, respectively. The detection limit of the current technique for EDTA analysis was 0.2 microg/L with an additional 10-fold preconcentration procedure, based on the signal-to-noise ratio of 3. As opposed to the classical capillary zone electrophoresis (CE) method, the detection limit was improved about 1000-fold by using this LVSEP method. To the best of our knowledge, it represents the highest sensitivity for EDTA analysis via CE. Several drinking water samples were tested by this novel method with satisfactory results.  相似文献   

19.
An approach to the detection and determination of chitosan aggregates in acetic acid solutions is proposed using pressure-assisted capillary zone electrophoresis. Processes of chitosan aggregation are studied depending on the composition of dispersion medium and storage time. The presence of several species of positively charged chitosan aggregates is revealed for the first time. Particle sizes in the range 20–2500 nm are determined by scanning electron microscopy and static and dynamic light scattering. The dependence of the shape of electropherograms on particle size distribution obtained under the same conditions is found. A trend to changing electrophoretic mobility depending on the size of the aggregate is observed, which enables the approximate evaluation of the polydispersity of chitosan solutions. Chitosan is used for the effective dynamic modification of capillaries, which does not require the introduction of a modifier into the background electrolyte.  相似文献   

20.
In capillary electrophoresis (CE) analysis of small inorganic anions, the ability to control the electroosmotic flow (EOF) and the ability to alter the electrophoretic mobility of the ions are essential to improve resolution and separation speed. In this work, a CE method for separation of small inorganic anions using indirect detection in mixed methanol/water buffers is presented. The suitability of different UV absorbing probes commonly used for indirect detection including chromate, iodide, phthalate, benzoate, trimellitate, and pyromellitate, in mixed methanol/water buffers is examined. The effect of the electrolyte buffer system, including the pH, buffer concentration and the organic solvent on the electrophoretic mobility of the probes and analytes are also investigated. The EOF was reversed using cationic surfactant, cetyltrimethylammonium bromide (CTAB) so ions were separated under co-EOF mode. The organic solvent alters the electrophoretic mobility of the probes and the analytes differently and hence choice of the appropriate probe is essential to achieve high degree of detection sensitivity. Separations of six anions in less than 2.5 min were accomplished in buffers containing up to 30% MeOH. Adjustment of the methanol content helps to improve the selectivity and resolution of inorganic anions. Limit of detection, reproducibility and application of the method for quantification of anions in water samples will also be discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号