首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Peptide mass fingerprinting (PMF) is a powerful technique in which experimentally measured m/z values of peptides resulting from a protein digest form the basis for a characteristic fingerprint of the intact protein. Due to its propensity to generate singly charged ions, along with its relative insensitivity to salts and buffers, matrix-assisted laser desorption and ionization (MALDI)-time-of-flight mass spectrometry (TOFMS) is the MS method of choice for PMF. The qualitative features of the mass spectrum can be selectively tuned by employing different methods to prepare the protein digest and matrix for MALDI-TOFMS. The selective tuning of MALDI mass spectra in order to optimize PMF is addressed here. Bovine serum albumin, carbonic anhydrase, cytochrome c, hemoglobin alpha- and beta-chain, and myoglobin were digested with trypsin and then analyzed by MALDI-TOFMS. 2,5-dihydroxybenzoic acid (DHB) and alpha-cyano-4-hydroxycinnamic acid (CHCA) were prepared using six different sample preparation methods: dried droplet, application of protein digest on MALDI plate followed by addition of matrix, dried droplet with vacuum drying, overlayer, sandwich, and dried droplet with heating. Improved results were obtained for the matrix alpha-cyano-4-hydroxycinnamic acid using a modification of the died droplet method in which the MALDI plate was heated to 80 °C prior to matrix application, which is supported by observations from scanning electron microscopy. Although each protein was found to have a different optimum sample preparation method for PMF, in general higher sequence coverage for PMF was obtained using DHB. The best PMF results were obtained when all of the mass spectral data for a particular protein digest was convolved together.  相似文献   

2.
Separation of a protein mixture by size-exclusion chromatography (SEC) was combined with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). Identification of proteins in the collected fractions was performed both as intact proteins by MALDI-TOFMS and using peptide mass fingerprinting (PMF) after their digestion with trypsin. The presence of salts mostly disturbs the MALDI-TOFMS signal and, therefore, proper purification or desalting procedures must be employed. Four desalting procedures (desalting column packed with Sephadex G-100, on-target washing, centrifugal filter devices and ZipTip C(18)) for purification of fractions of proteins separated by SEC and their tryptic digests prior to determination of their exact molecular masses by MALDI-TOFMS were compared. In the case of intact proteins, the experiments showed that the best desalting procedures are the use of ZipTip C(18) pipette tips and Ultrafree CL centrifugal filter devices. The peptide digests can be purified by using ZipTip C(18) pipette tips or on-target washing when both of these procedures provide similar results. On-target washing can be used as a simple procedure to improve the mass spectra of salt-containing samples. Analyses of the droplets collected after the on-target washing show losses of sample and matrix caused by dissolution of these compounds during this procedure. Further, it was found that protein identification based on PMF is more sensitive than analyses of intact proteins and that multiple on-target washing is very advantageous for analyses of peptide mixtures with a high content of salts.  相似文献   

3.
Peptide Mass Fingerprinting (PMF) is still of significant interest in proteomics because it allows a large number of complex samples to be rapidly screened and characterized. The main part of post-translational modifications is generally preserved. In some specific cases, PMF suffers from ambiguous or unsuccessful identification. In order to improve its reliability, a combined approach using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICRMS) was evaluated. The study was carried out on bovine serum albumin (BSA) digest. The influence of several important parameters (the matrix, the sample preparation method, the amount of the analyte) on the MOWSE score and the protein sequence coverage were evaluated to allow the identification of specific effects. A careful investigation of the sequence coverage obtained by each kind of experiment ensured the detection of specific peptides for each experimental condition. Results highlighted that DHB-FTICRMS and DHB- or CHCA-TOFMS are the most suited combinations of experimental conditions to achieve PMF analysis. The association (convolution) of the data obtained by each of these techniques ensured a significant increase in the MOWSE score and the protein sequence coverage.  相似文献   

4.
A novel MALDI LIFT-TOF/TOF mass spectrometer for proteomics   总被引:7,自引:0,他引:7  
A new matrix-assisted laser-desorption/ionization time-of-flight/time-of-flight mass spectrometer with the novel "LIFT" technique (MALDI LIFT-TOF/TOF MS) is described. This instrument provides high sensitivity (attomole range) for peptide mass fingerprints (PMF). It is also possible to analyze fragment ions generated by any one of three different modes of dissociation: laser-induced dissociation (LID) and high-energy collision-induced dissociation (CID) as real MS/MS techniques and in-source decay in the reflector mode of the mass analyzer (reISD) as a pseudo-MS/MS technique. Fully automated operation including spot picking from 2D gels, in-gel digestion, sample preparation on MALDI plates with hydrophilic/hydrophobic spot profiles and spectrum acquisition/processing lead to an identification rate of 66% after the PMF was obtained. The workflow control software subsequently triggered automated acquisition of multiple MS/MS spectra. This information, combined with the PMF increased the identification rate to 77%, thus providing data that allowed protein modifications and sequence errors in the protein sequence database to be detected. The quality of the MS/MS data allowed for automated de novo sequencing and protein identification based on homology searching.  相似文献   

5.
This paper focuses on the technical aspects of chemical screening from 384-well plate nano-scale single-bead combinatorial libraries. The analytical technique utilized is a combination of capillary liquid chromatography with ultraviolet detection and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The HPLC/MALDI-MS hyphenation is achieved by means of a micro-fraction collector with a peak detection system that automatically collects the peaks onto the MALDI targets for subsequent characterization. Several experimental parameters such as type of 384-well plate, well-plate sealing foils, and a column-switching procedure were investigated using a small test library of nine components. Additionally, the influence of different MALDI matrices, different MALDI targets and sample-spotting techniques on the MALDI detection sensitivity as well as the ruggedness and sample throughput capacity of this technique were studied. Optimum results for the analytes investigated were obtained with 2,5-dihydroxybenzoic acid using on-line mixing of HPLC effluent and matrix solution. To demonstrate the potential of this capillary HPLC/MALDI-TOFMS method, its application to several single-bead libraries was investigated. The instrumental method allowed for the rapid identification and purity assessment of combinatorial libraries with detection limits down to the higher femtomole level using both UV detection and MALDI mass spectrometry.  相似文献   

6.
The capabilities and limitations of 384-well formatted sample preparation technologies applied to regulated bioanalysis were evaluated by developing two assays for the simultaneous quantitation of lopinavir and ritonavir, the active ingredients of Kaletra. One method used liquid-liquid extraction (LLE), and the other used solid-phase extraction (SPE). The steps and apparatuses employed by the two methods covered most of those used for bioanalysis. Briefly, the previously validated 96-well formatted assays were adapted to the 384-format with minor modifications. Because the wells of a 384-well plate are clustered together, cross-contamination between adjacent wells was evaluated critically, along with sensitivity, assay throughput, and ruggedness. Samples (35 microL) containing plasma samples (15 microL), internal standard (10 microL), and sodium carbonate (0.5 M, 10 microL to basify the sample) were placed in a 384-well microtiter plate that may contain saquinavir or amprenavir as contamination markers. For LLE preparation, the samples were placed in a deep 384-well plate (300-microL well volume) and extracted with 150 microL of ethyl acetate. Approximately 50 microL of the extracts were removed from each well after phase separation for analysis. For SPE preparation, the fortified samples were transferred to a 384-formatted SPE plate (C18, 5 mg packing). The extracts were eluted from the plate with basified 2-propanol. The LLE or SPE extracts were dried and reconstituted for column-switching high-performance liquid chromatography with tandem mass spectrometric detection (HPLC/MS/MS). The lower limit of quantitation and the assay range were the same as the 96-well formatted assay. If combined with appropriate automation, sample preparation in the 384-well format would be up to five times more efficient than the 96-well format.  相似文献   

7.
In this study various methods of sample preparation and matrices were investigated to determine optimum collection and analysis criteria for fungal analysis by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Intact spores and/or hyphae of Aspergillus niger, Rhizopus oryzae, Trichoderma reesei and Phanerochaete chrysosporium were analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The fungal samples were applied to the MALDI sample target as untreated, sonicated, or acid/heat treated samples, or blotted directly from the fungal culture with double-stick tape. Ferulic acid or sinapinic acid matrix solution was layered over the dried samples and analyzed by MALDI-MS. Statistical analysis showed that simply using double-stick tape to collect and transfer to a MALDI sample plate typically worked as well as the other preparation methods, and required the least sample handling.  相似文献   

8.
In this work, a high repetition rate laser matrix-assisted laser desorption/ionization (MALDI) source is studied on a quadrupole-time-of-flight (QqTOF) and a triple quadrupole (QqQ) mass spectrometer for rapid quantification of small pharmaceutical drugs. The high repetition rate laser allows an up to 100-fold higher pulse frequency as compared with regular MALDI lasers, resulting in much larger sample throughput and number of accumulated spectra. This increases the reproducibility of signal intensities considerably, with average values being around 5% relative standard deviation after taking into account the area ratio of the analyte to an internal standard. Experiments were conducted in MS/MS mode to circumvent the large chemical background due to MALDI matrix ions in the low mass range. The dynamic range of calibration curves on the QqTOF mass spectrometer extended over at least two orders of magnitude, whereas on the QqQ it extended over at least three orders of magnitude. Detection limits ranged from 60-400 pg/microL on the QqTOF and from 6-70 pg/microL on the QqQ for a series of benzodiazepines. The benzodiazepine content of commercial pill formulations was quantified, and less than 5% error was obtained between the present method and the manufacturer's certified values. Furthermore, a high sample throughput was achieved with this method, so that a single MALDI spot could be quantitatively scanned in as little as 15 s, and an entire 96-well MALDI plate in 24 min.  相似文献   

9.
Recent developments in proteomics have revealed a bottleneck in bioinformatics: high-quality interpretation of acquired MS data. The ability to generate thousands of MS spectra per day, and the demand for this, makes manual methods inadequate for analysis and underlines the need to transfer the advanced capabilities of an expert human user into sophisticated MS interpretation algorithms. The identification rate in current high-throughput proteomics studies is not only a matter of instrumentation. We present software for high-throughput PMF identification, which enables robust and confident protein identification at higher rates. This has been achieved by automated calibration, peak rejection, and use of a meta search approach which employs various PMF search engines. The automatic calibration consists of a dynamic, spectral information-dependent algorithm, which combines various known calibration methods and iteratively establishes an optimised calibration. The peak rejection algorithm filters signals that are unrelated to the analysed protein by use of automatically generated and dataset-dependent exclusion lists. In the "meta search" several known PMF search engines are triggered and their results are merged by use of a meta score. The significance of the meta score was assessed by simulation of PMF identification with 10,000 artificial spectra resembling a data situation close to the measured dataset. By means of this simulation the meta score is linked to expectation values as a statistical measure. The presented software is part of the proteome database ProteinScape which links the information derived from MS data to other relevant proteomics data. We demonstrate the performance of the presented system with MS data from 1891 PMF spectra. As a result of automatic calibration and peak rejection the identification rate increased from 6% to 44%.Abbreviations 2-DE Two-dimensional gel electrophoresis - MALDI Matrix-assisted laser desorption ionisation - PMF Peptide mass fingerprinting - MS Mass spectrometry - TOF Time of flight  相似文献   

10.
A limitation of any current approach using solvent-free MALDI mass spectrometry is that only one sample at a time can be prepared and transferred to the MALDI-plate. For this reason, multiple-sample preparation approaches for solvent-free MALDI MS analysis of synthetic polymers were developed that are simple and practical. One approach multiplexed sample preparation by simultaneously preparing multiple samples. With this approach, as many as 384 samples could be prepared by addition of analyte, matrix, salt, and 1-mm metal beads to each well of a 384-well disposable bacti plate, capping the plate with the lid and homogenizing all samples simultaneously using a common laboratory vortex device. Besides the time savings achieved by a single vortex step for multiple samples, an additional advantage of this method relative to previously reported solvent-free preparation methods is that the mixing volume per sample is reduced, which allows a reduction in the amount of analyte required. This method, however, still requires the transfer of each homogenized sample to the MALDI plate for subsequent analysis. Here we report a novel approach that combines multiple simultaneous solvent-free sample preparation with automatic sample transfer to the MALDI target plate. This approach reduces the possibility of cross-contamination, the amount of sample and matrix consumed for an analysis, and the time required for preparation of multiple samples. These methods were shown to provide high-quality mass spectra for various synthetic polymer standards with M(n) values to 10 kDa. The methods are efficient in that small sample amounts are required, the sample/salt/matrix ratio is not critical, and the time necessary to achieve sufficient homogenization of multiple samples is less than 5 min.  相似文献   

11.
To enhance sample signals and improve homogeneity in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF) analysis, a simple, rapid, and efficient sample preparation method was developed in this study. Polydimethylsiloxane (PDMS) was coated on a stainless steel MALDI plate, forming a transparent, hydrophobic surface that enhanced sample signals without producing observable background signals. Compared to the use of an unmodified commercial metal MALDI plate, peptide signals were enhanced by ~7.1–11.0-fold due to the reduced sample spot area of the PDMS-coated plate, and showed improved peptide mass fingerprinting (PMF) and MS/MS peptide sequencing results. In the analysis of phosphopeptides and carbohydrates with a 2,5-dihydroxybenzoic acid (DHB) matrix, the PDMS-coated plate showed improved sample homogeneity and signal enhancements of ~5.2–8.2-fold and ~2.8–3.2-fold, respectively. Improved sensitivity in the observation of more unique fragment ions by MS/MS analysis, to successfully distinguish isomeric carbohydrates, was also illustrated. In protein analysis with a sinapinic acid (SA) matrix, a ~3.4-fold signal enhancement was observed. The PDMS film coating was easily removed and refabricated to avoid sample carryover, and was applicable to diverse commercial MALDI plates. The PDMS-coated approach is a simple, practical, and attractive method for enhancing analyte signals and homogeneity.  相似文献   

12.
A simple reversed-phase nano-column purification and sample preparation technique is described, which markedly improves the mass spectrometric analysis of complex and contaminated peptide mixtures by matrix-assisted laser desorption/ionization (MALDI). The method is simple, fast and utilizes only low-cost disposables. After loading the sample on the column and a subsequent washing step, the analyte molecules are eluted with 50-100 nl of matrix solution directly on to the MALDI/MS target. The washing step ensures removal of a wide range of contaminants. The small bed volume of the column allows efficient sample concentration and the elution process yields very small sample spots. This simplifies the analysis and minimizes discrimination effects due to sample heterogeneity, because the desorption/ionization laser simultaneously irradiates a large portion of the sample. Taken together, these features of the method significantly improve the sensitivity for MALDI/MS analysis of contaminated peptide samples compared with the commonly used sample preparation procedures. This is demonstrated with in-gel tryptic digests of proteins from human brain that were separated by 2D gel electrophoresis. Furthermore, it is shown that with this method 2,5-dihydroxybenzoic acid (DHB) acts as an efficient matrix for peptide mapping. Both detection sensitivity and sequence coverage are comparable to those obtained with the currently preferred matrix alpha-cyano-4-hydroxycinnamic acid (CHCA). The higher stability of peptide ions generated with DHB compared with CHCA is advantageous when analyzing fragile sample molecules. Therefore, the method described here is also of interest for the use of Fourier transform ion cyclotron resonance (FT-ICR) or ion-trap mass analyzers.  相似文献   

13.
The reagent 4-sulfophenyl isothiocyanate (SPITC) is an effective, stable, and inexpensive alternative to commercially available reagents used in the N-terminal sulfonation of peptides for enhanced postsource decay (PSD) in matrix-assisted laser desorption/ionization time-of-flight mass spectrometric (MALDI-TOFMS) analyses. However, suppression of ionization of sulfonated peptides due to sample and matrix contaminants such as sodium can be a problem when using prestructured MALDI target sample supports, such as the Bruker Daltonics AnchorChip. We show that use of the salt-tolerant matrix 2,4,6-trihydroxyacetophenone containing diammonium citrate (THAP/DAC) as an alternative to alpha-cyanohydroxycinnamic acid (HCCA) reduces the need for extensive washing of ZipTip-bound peptides or additional on-target sample clean-up steps. Use of the THAP/DAC matrix results in selective ionization of sulfonated peptides with greater peptide coverage, as well as detection of higher mass derivatized peptides, than was observed for HCCA or THAP alone. The THAP/DAC matrix is quite tolerant of sodium contamination, with SPITC-peptides detectable in preparations containing up to 50 mM NaCl. In addition, THAP/DAC matrix was found to promote efficient PSD fragmentation of sulfonated peptides. We demonstrated the utility of using the THAP/DAC MALDI matrix for peptide sequencing with DNA polymerase beta tryptic peptide mixture, as well as tryptic peptides derived from Xiphophorus maculatus brain extract proteins previously separated by two-dimensional polyacrylamide gel electrophoresis (2D-PAGE).  相似文献   

14.
An automated flow injection analysis (FIA) mass spectrometry system (AutoScan) was developed to allow rapid unattended determination of optimal conditions during mass (ms) and tandem mass spectrometry (ms/ms) on new chemical entities (NCEs) arranged in 96-well plates. The 96-well plate is placed on the deck of a modified Gilson Multiprobe autosampler for injection into a PE Sciex API 2000 triple quadrupole mass spectrometer. A customized software interface is used to create the necessary scan experiments by associating each 96-well plate of NCEs to be scanned with an index file containing data on the identity of each analyte and its expected molecular weight. Analytes are injected four at a time into a custom injection manifold and conventional mass spectra are acquired in both polarities (+/-) using an alternating positive/negative Q1 scan function. The software determines the optimal polarity and definitive precursor ion for all analytes and uses the results to build the injection sequence for product ion scanning. The samples are automatically re-injected under MS/MS conditions, and product ion scans that loop among different collision energies are collected for each analyte. The resulting data are processed automatically and the optimal MS/MS transitions for each analyte are selected. A color-coded graphical interface facilitates data review. Any unusual ion transitions or transposition errors made during plate preparation are noted and corrected. Complete MS and MS/MS conditions are obtained for 96 compounds in about one hour and the resulting data are available for download as sample control injection sequence files.  相似文献   

15.
This paper presents a highly efficient sample preparation technique for matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The purpose of the research is to use a conventional MALDI support to directly and conveniently detect sub-nM levels of peptides from volume-limited samples with physiological salt levels. In this new method, highly uniform matrix-nitrocellulose spots with a 500 microm diameter were conveniently generated by direct contact of a capillary tip to a stainless steel MALDI plate. An array of 50 microspots can be blotted from 1 microL matrix-nitrocellulose solution within 1 min. It was found that the addition of high concentration nitrocellulose to the alpha-cyano-4-hydroxycinnamic acid (CHCA) matrix solution is critical for the formation of microspots. Samples are deposited on top of those microspots and incubated for 3 min. The CHCA-nitrocellulose surface shows a significant peptide binding capability for sub-nM levels of peptide. Restricting the matrix spot diameter to 500 microm gives an analyte enrichment effect because the peptides are confined to a small solid-phase surface area. Selective peptide binding is seen even with >0.15 M salt levels. Loading small aliquots of samples with multiple applications allows low level peptide detection down to 100 pM. Push-pull perfusates collected from the rat striatum were successfully analyzed with the microspot method.  相似文献   

16.
We investigated a variant of desorption/ionization on porous silicon (DIOS) mass spectrometry utilizing an aqueous suspension of either porous silica gel or porous alumina (pore size of 60 and 90 A, respectively). Laser desorption/ionization (LDI) from samples directly deposited on a stainless steel surface without any inorganic substrates was also achieved. Synthetic peptides designed to cover large sequence diversity constituted our model compounds. Sample preparation, including material conditioning, peptide solubilization, and deposition protocol onto standard matrix-assisted laser desorption/ionization (MALDI) probe, as well as ionization source tuning were optimized to perform sensitive reproducible LDI analyses. The addition of either a cationizing agent or an alkali metal scavenger to the sample suspension allowed modification of the ionization output. Comparing hydrophilic silica gel to hydrophobic reversed-phase silica gel as well as increasing material pore size provided further insights into desorption/ionization processes. Furthermore, mixtures of peptides were analyzed to probe the spectral suppression phenomenon when no interfering organic matrix was present. The results gathered from synthetic peptide cocktails indicated that LDI mass spectrometry on silica gel or alumina constitutes a promising complementary method to MALDI in proteomics for peptide mass fingerprinting.  相似文献   

17.
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOFMS) can be used to determine number- and weight-average molecular weights of narrow polydispersity polymers. In this work, several possible sources of error in determining molecular weights of polymers with narrow polydispersity by MALDI-TOFMS are rigorously examined. These include the change in polymer distribution function, broadening or narrowing of the overall distribution, and the truncation of selected oligomer peaks within a distribution (i.e., the oligomer peaks at the high-and low-mass tails expected to be observed are not detected). These variations could be brought about by a limited detection sensitivity, background interference, and/or mass discrimination of oligomer analysis in MALDI-TOFMS. For narrow polydispersity polystyrenes, it is shown that by using an appropriate MALDI matrix and sample preparation protocol and a sensitive ion detection instrument, no systematic errors from these possible variations were detected within the experimental precision (0.5% relative standard deviation) of the MALDI method. It is concluded that MALDI mass spectrometry can provide accurate molecular weight and molecular weight distribution information for narrow polydispersity polymers, at least for polystyrenes examined in this work. The implications of this finding for polymer analysis are discussed.  相似文献   

18.
High-sensitivity, high-throughput analysis of proteins for proteomics studies is usually performed by polyacrylamide gel electrophoresis in combination with mass spectrometry. However, the quality of the data obtained depends on the in-gel digestion procedure employed. This work describes an improvement in the in-gel digestion efficiency for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) analysis. A dramatic improvement in the coverage of tryptic peptides was observed when n-octyl glucoside was added to the buffer. Whole cell extracted proteins from S. cerevisiae were separated by two-dimensional gel electrophoresis and stained with silver. Protein spots were identified using our improved in-gel digestion method and MALDI-TOFMS. In addition, the mass spectra obtained by using the matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) were compared with those obtained using 2,5-dihydroxybenzoic acid (DHB). The DHB matrix usually gave more peaks, which led to higher sequence coverage and, consequently, to higher confidence in protein identification. This improved in-gel digestion protocol is simple and useful for protein identification by MALDI-TOFMS.  相似文献   

19.
A rapid method for analysis of glycans of glycoproteins is presented. This method comprised deglycosylation, sample cleanup and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analysis of glycans. The enzymatic deglycosylation of N-linked glycoproteins was enhanced in terms of speed and reproducibility using an enzyme-friendly surfactant. The released glycans were desalted using a micro-scale solid phase extraction (SPE) device packed with a hydrophilic interaction chromatography (HILIC) sorbent. Hydrophilic glycans were well retained by SPE, while salts and surfactants were removed from the sample. The glycans were eluted using 25-50 microL of solvent and analyzed directly without derivatization using MALDI-MS. MALDI quadrupole time-of-flight (Q-Tof) instrumentation was utilized for glycan profiling and structure characterization by tandem mass spectrometry (MS/MS). The presented method allows sensitive analysis of glycans benefiting from optimized deglycosylation reactions and efficient sample cleanup.  相似文献   

20.
Capillary electrophoresis (CE) was coupled off-line with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) for the analysis of proteins and peptides. CE fractions were collected directly on a matrix-coated MALDI target, using a sheath-flow interface. Protein adsorption during CE separations was prevented by coating the capillaries with the physically adsorbed, cationic polymer PolyE-323. The CE/MALDI-MS system was used for the analysis of model proteins and peptides at physiological pH as well as analysis of proteins in tear fluid. Moreover, tryptic on-target digestion of the collected protein fractions, with subsequent MALDI-MS and MS/MS peptide analysis, was demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号