首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
A method has been developed for the determination of beryllium in urine by graphite-furnace atomic absorption spectrometry. Ammonium 12-molybdophosphate and ascorbic acid were employed as a matrix modifier. The tolerable charring temperature for beryllium in both aqueous solution and urine was raised to 1400 °C in the presence of a matrix modifier. The sensitivity for the determination of beryllium was also improved by a factor of 1.5 in comparison with that obtained by using magnesium nitrate as a matrix modifier. The mechanism of the enhancement effect of ammonium molybdophosphate was ascribed to the effectiveness of the formation of gaseous BeO, which is a precursor of free beryllium. Beryllium in urine can be determined simply by dilution with ascorbic acid solution. The relative standard deviation for seven replicate determinations of beryllium was 1.9% for a urine sample containing 0.029 μg ml?1 of beryllium.  相似文献   

2.
Low-temperature ashing and dry ashing at 500°C are compared for the analysis of urine and human milk. Dry ashing gives superior accuracy. The importance of contamination control, background correction and temperature control are stressed. Both urine and human milk contain about 1 ng Cr ml-1.  相似文献   

3.
Wet digestion using a mixture of nitric, sulfuric, and perchloric acids and an aluminum block digester effectively and rapidly decomposed meat samples for selenium determination by hydride generation atomic absorption spectrophotometry. Digestion did not require constant attention by an operator. Selenium recoveries (range, 94-105%) from National Institute of Standards and Technology standard reference materials and spiked samples were used to validate method accuracy. Coefficients of variation (CVs) of repeatability of in-house reference materials used for precision study were 6.4 and 5.6%, respectively, for seafood mix and mutton liver. Selenium levels in meat products from Brisbane markets varied widely: 0.042-0.142, 0.081-0.42, and 0.050-0.198 microgram/g (wet weight) respectively, for beef, chicken, and pork. Overall, selenium levels in manufactured meat ranged from 0.041 to 0.189 microgram/g. The levels of selenium found in this study were generally lower than those reported in Finland but comparable with those reported in some parts of the United States.  相似文献   

4.
The problems involved in the determination of selenium by atomic absorption spectrophotometry are discussed. A practical method is described for which the sensitivity is approximately 1 p.p.m. Such concentrations can be determined in organic samples, but with mineral samples the preliminary treatment renders the procedure unsuitable for concentrations lower than 50 p.p.m. in a sulphide ore.  相似文献   

5.
6.
A simple method is described for the determination of selenium in human tissues without the use of perchloric acid. Digestion with nitric and sulphuric acids is followed by hydride generation and atomic absorption spectrometry. Results for NBS bovine liver and IAEA horse kidney reference materials were in good agreement with assigned concentrations, as was also achieved with the perchloric acid digestion. Recovery of added selenium was >90%, and the relative standard deviation was 5.5% for within-batch and 6.9% for between-batch analyses. The values of selenium in heart tissue were 0.9–1.3 μg g?1 dry weight.  相似文献   

7.
For the determination of total mercury in hair, an amount (25.0 mg) of hair sample was digested with conc. HNO3 (400 microl) at 90 degrees C for 10 min in a 7-ml teflon microreaction vessel. After digestion, the pH of the acidic hair mixture was adjusted to 5.0-6.0 by NaOH and was then passed through a clean-up Sep-Pak C18 cartridge. To the eluate, 2,3-dimercaptopropane-1-sulfonate (DMPS) and sodium acetate buffer (pH = 6.0) were added to form a mercury-DMPS complex. This complex was preconcentrated on two Sep-Pak C18 cartridges in series, and each cartridge was eluted with methanol and adjusted to 2.00 ml. A portion (50 microl) was introduced into a graphite cuvette and then atomized according to a temperature program. The method detection limit (MDL, 3sigma) was 0.064 (microg g(-1)); the calibration graph was linear up to 7.52 microg g(-1). Good accuracies were obtained when testing two human hair certified reference materials (GBW 09101 and BCR-397). Six real samples were analyzed, and the recoveries were 95.8 - 98.2% with a relative standard deviation (RSD, n = 3) < 2.1%. For the determination of methylmercury (CH3Hg+), 25.0 mg of hair sample was extracted with 2.0 mol dm(-3) HCl (1.0 ml) by ultrasonicating for 1 h. The supernatant solution was used for CH3Hg+ analysis and the hair residue was used for the analysis of inorganic mercury (Hg2+). The MDL of CH3Hg+ was 0.068 microg g(-1); the calibration graph was linear up to 6.00 microg g(-1). Six real samples were analyzed, and the recoveries were 96.0-99.2% with RSD (n = 3) < 2.3%. The sum of the concentrations of CH3Hg+ and Hg2+ was very close to that of the total mercury measured with a relative error within 3.6%. The proposed method can be accurately applied to the measurement of CH3Hg+, Hg2+, and total mercury in hair samples.  相似文献   

8.
Inorganic anions and organic compounds are determined using conventional atomic absorption apparatus. Several methods are studied in which the desired compound either limits or interferes with the determination or absorption of a metal. A direct relationship is obtained between the absorption by the metal and the amount of substance sought. Substances determined include orthophosphate, sulfate, iodide, sulfide, iodate, glucose, protein, 8-hydroxyquinoline, ethylenediaminetetraacetic acid, and ammonium pyrrolidine dithiocarbamate.  相似文献   

9.
Methods for the determination of vanadium, in the range 0.5–100 mg/l, by atomic absorption spectroscopy in an oxy-acetylene as well as in a nitrous oxideacetylene flame are presented. For use with oxy-acetylene flames, vanadium is extracted as vanadium cupferrate into a mixture of methyl isobutyl ketone and oleic acid (78:22, v/v) and the organic phase is aspirated to the flame. The sensitivity is 0.7 mg/l of vanadium in the organic phase. For nitrous oxide-acetylene flames, an aqueous solution of vanadium is aspirated directly. The sensitivity is further improved by the use of methyl isobutyl ketone, the addition of Al3+ and diethylene glycol diethyl ether. Many potential interferences were examined and methods to overcome those found are given.  相似文献   

10.
Summary The determination of thallium by atomic-absorption Spectrophotometry is described. Many substances interfere with the direct analysis of thallium under the conditions chosen. However, these interferences can be overcome by adding a lithium, potassium, or sodium buffer (5000 ppm). In this way the deviations caused by foreign substances can be reduced to less than ten per cent. Under the same conditions the effect of organic solvents has been studied.
Zusammenfassung Die Bestimmung von Thallium mit Hilfe der atomaren Absorptionsspektrophotometrie wird beschrieben. Die direkte Bestimmung von Thallium wird im allgemeinen durch viele Fremdionen in höheren Konzentrationen gestört. Durch Verwendung eines Li-, K-, oder Na-Puffers (5000 ppm) können die Störungen auf weniger als 10% herabgesetzt werden. Unter den gleichen experimentellen Bedingungen wird die Wirkung von organischen Lösungsmitteln untersucht.
  相似文献   

11.
Hao DQ  Xie GH  Zhang YM  Tian GJ 《Talanta》1996,43(4):595-600
Serum is rapidly digested with a mixture of nitric and perchloric acids at a temperature of 180 +/- 10 degrees C, and hydrochloric acid is used to reduce selenium(VI) to selenium(IV). Selenium is determined by hydride generation flame atomic absorption spectrometry. The results show that this method has the advantages of being sensitive, accurate, rapid and simple. After the serum is digested and diluted, 4.0 ml is taken for the determination. The characteristic concentration, detection limit, variation coefficient, recovery rate and linear range are 2.93 mug 1(-1), 1.55 mug l(-1), 1.6-5.0%, 97.3-99.2% and 0.0-320.0 mug l(-1) respectively. Serum at 4 degrees C and in frozen state can be preserved for at least 7 and 14 days, respectively.  相似文献   

12.
Manganese is determined in serum and urine by graphite-furnace atomic absorption spectrometry after dilution (1 + 1) with distilled water. Simple aqueous standards are used for calibration. Background absorption from the matrix is decreased by attention to the heating programme, sample dilution and gas flow-rate during atomisation. Remaining background absorption is removed by a deuterium-arc background correction system. To obtain accurate results, great care is needed in collecting samples to avoid contamination. Blood is collected through a plastic cannula, because stainless steel needles introduce considerable contamination. The mean normal concentration of manganese in serum was found to be 0.58 μg l?1 (it- = 9) which is in agreement with other literature values. For urine, the mean normal concentration found was 0.7 μg l?1 (it- = 16). Patients on total parenteral nutrition with manganese supplements show elevated serum and urine manganese concentrations.  相似文献   

13.
A simple and rapid acid digestion method for the decomposition of estuarine sediments is described. Quantitative recovery of Cd, Pb, Cu, Ni, Co, Be and Co is demonstrated. Sensitive, precise and accurate determination of these trace metals by graphite-furnace atomic absorption spectrometry in combination with the L'vov Platform provides an interference-free technique that permits calibration with simple aqueous solutions of metal standards. The accuracy of the method has been confirmed by analysis of two marine sediment reference materials, MESS-1 and BCSS-1.  相似文献   

14.
An atomic absorption spectrophotometric method for the determination of 0.001–0.10% magnesium in irons has been proposed. After suitable dissolution of the sample, 1500 p.p.m. of strontium is added to suppress aluminium interference and the solution is atomised in an atomic absorption spectrophotometer. The method is rapid, has high sensitivity, is free from interference and no preliminary separations are required.  相似文献   

15.
A method was developed for the determination of selenium in human milk using electrothermal atomic absorption spectrometry. The use of chemical modifiers as well as their implications during the pyrolysis step was examined. The chemical modifiers that were studied were Zr, Ir as well as the mixed modifier Zr-Ir. The Ir modifier stabilized selenium at 1000 °C, Zr at 800 °C, while the mixed modifier at 1200 °C. The effect of modifier mass was studied and was found that better results are achieved with addition of 2 μg Zr and 2 μg Ir. The characteristic masses of selenium in the presence of Zr, Ir and the mixed modifier were found to be 73.3, 18.0 and 14.7 pg, respectively, while the corresponding limits of detection were found 2.0, 0.50 and 0.41 μg l−1. Consequently better results were obtained with the mixed modifier. The developed method was applied for the determination of selenium in human milk, which was digested with a HNO3 + H2O2 mixture in a microwave oven. The limit of detection of the method was 1.37 μg l−1, the characteristic mass, m0, was 48.8 pg and the repeatability was less than 5% as R.S.D.(%). Matrix matched calibration was used. Recoveries were estimated to be 93-105%. The method was applied to breast milk of Greek women (n = 9) and the Se content was found to be in the range 16.7-42.6 μg l−1 with mean value 27.4 ± 5.5 μg l−1.  相似文献   

16.
17.
An efficient method was developed for the determination of nanogram levels of lithium in biological samples. Serum samples from human subjects from southeastern Spain, treated or not treated with lithium carbonate, were analyzed by electrothermal atomic absorption spectrometry. The samples were previously treated with a matrix modifier consisting of 0.1% Triton X-100 and injected through a graphite tube with L'vov platform. The Li concentrations measured by the procedure described for the 3 certified reference samples used were not significantly different (p > 0.05) than certified levels. Sample recoveries and variability during several days, with coefficients of variation from 4.00 to 14.8%, demonstrated the reliability and accuracy of this technique. Mean Li concentration determined in the serum of individuals with psychiatric disorders treated with Li (n = 117, 5.077 +/- 1.795 microg Li/mL) was significantly higher (p < 0.001) than that in individuals not treated with Li (n = 24, 1.902 +/- 2.054 ng Li/mL).  相似文献   

18.
An accurate and sensitive method for serum chromium determinations by graphite-furnace atomic absorption spectrometry is described. Samples containing a small amount of magnesium nitrate as an ashing aid/matrix modifier are lyophilized and dry-ashed in silanized quartz tubes; the residue is dissolved in 0.1 M HCl. Because of the very low levels of chromium in serum, strict contamination control measures must be used throughout the procedures for collection, storage, preparation and quantitation. Standard curves are prepared by using a bovine serum pool, which also serves as a quality control measure. The uniform nature of sera obviates the need to use the method of standard additions. The detection limit of the method is about 0.03 ng ml?1 Cr and the accuracy of the method is evaluated by comparison with stable-isotope-dilution mass spectrometry.  相似文献   

19.
Trace amounts of cobalt and nickel in a water sample were quantitatively coprecipitated with scandium hydroxide at pH 8.0-10.5. Because the coprecipitant could be easily dissolved with 1 mol dm(-3) nitric acid, and the presence of up to 10 mg cm(-1) of scandium did not interfere with the graphite-furnace atomic absorption spectrometric determination of cobalt and nickel, the volume of the final solution prepared for the determination could be minimized down to 0.5 cm3. The concentration factor was 400-fold and the detection limits (signal to noise = 2) were 5.0 pg cm(-3) of cobalt and 10.0 pg cm(-3) of nickel in 200 cm3 of the initial sample solution. The 27 diverse ions investigated did not interfere with the determination in at least a 500-fold mass ratio to cobalt or nickel. The proposed method was successfully applied to the determination of trace amounts of cobalt and nickel in river-water samples.  相似文献   

20.
Summary The electrothermal atomization of selenium has been investigated for the accurate determination of selenium in water samples. Hydrogen seriously affects the atomization temperature of selenium in a molybdenum micro-tube atomizer. The atomization of selenium also suffers from serious interferences caused by salts and other elements. The extraction of selenium diethyldithiocarbamate complex serves to eliminate the interferences from the matrix. The addition of copper allows the suppression of interferences from elements extracted with selenium. The method permits the determination of selenium(IV) and selenium(VI) separately.This research was in part funded by the Ministry of Education, Science and Culture, Japan, under Grant-in-Aid for Scientific Research, for which we express our appreciation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏