首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid and sensitive substoichiometric radiochemical method has been developed for the comparative extraction and quantification of silver with potassium salts of ethyl, propyl, butyl, pentyl and benzyl xanthates from hydrochloric, nitric and sulfuric acid media into chloroform. The effect of 0.1–4M H+ ion concentration of the respective acid on the substoichiometric extraction of silver was critically studied. The efficiency of the method developed was tested by the determination of 10–100 g silver in standard solutions with an average percentage of error better than 2. The methods developed have been utilized to determine silver content in photofilm washing collected from various photostudios in Tirupati, India.  相似文献   

2.
A comparative study of the extractability of cadmium with potassium salts of ethyl, propyl, butyl, pentyl and benzyl xanthates into chloroform and a mixture of 14 pyridine and ethyl acetate from pH 1–7 buffers and sodium formate media, respectively, has been carried out employing an accurate and highly sensitive substoichiometric radiochemical method. The effect of foreign ions on the extractability was studied. The method developed was utilized for the determination of cadmium content in standard as well as in geological water samples.  相似文献   

3.
A rapid and sensitive substoichiometric radiochemical method has been developed for the comparative extraction and quantification of silver with potassium salts of ethyl, propyl, butyl, pentyl and benzyl xanthates from hydrochloric, nitric and sulfuric acid media into chloroform. The effect of 0.1–4M H+ ion concentration of the respective acid on the substoichiometric extraction of silver was critically studied. The efficiency of the method developed was tested by the determination of 10–100 μg silver in standard solutions with an average percentage of error better than 2. The methods developed have been utilized to determine silver content in photofilm washing collected from various photostudios in Tirupati, India.  相似文献   

4.
The relative extent of extraction of mercury with potassium salts of ethyl, propyl, butyl, pentyl and benzyl xanthates has been studied employing a sensitive and rapid substoichiometric radiochemical method. The effect of pH on the extractability of mercury xanthate complexes into chloroform was investigated. Buffer solutions of pH 12, 11, 10, 9 and 5.5 were found to be suitable media for the maximum extraction of mercury as ethyl, propyl, butyl, pentyl and benzyl xanthate complexes, respectively. The procedures developed were utilized for the determination of mercury content in standard solutions and geological water samples collected in eight parts of Chittoor district of Andhra Pradesh.  相似文献   

5.
A rapid and sensitive substoichiometric radiochemical procedure has been developed for the extraction of cobalt with potassium salts of ethyl, propyl, butyl, pentyl and benzyl xanthates. The relative extractabilities of the cobalt-xanthate complexes into chloroform and carbon tetrachloride were studied. Substoichiometric quantification methods were developed in each case and utilised to determine the cobalt content present in standard solutions as well as biological samples.  相似文献   

6.
Donaldson EM 《Talanta》1976,23(6):411-416
The chloroform extraction of 32 elements (Fe, Co, Ni, Zn, Cd, Ge, Sn, Pb, V, As, Sb, Bi, Cu, Ag, Au, Mn, Re, Ga, In, Tl, Ce, Se, Te, Cr, Mo, U, Pt, Pd, Rh, Ir, Ru and Os) from O.1-10M hydrochloric acid media in the presence of potassium ethyl xanthate has been studied. The oxidation states in which some elements react, and potential analytical separations, are discussed. Pd(II), As(III) and Se(IV) are completely extracted as ethyl xanthate complexes, Te(IV) is almost completely extracted, and Au(III) is largely extracted over the range of acid concentration investigated. Mn(II), Zn, Rh(III), Ir(IV), Ru(III), Os(IV), Cr(III), Cr(VI), Ce(III) and Ce(IV) are not extracted. Ge is partly extracted from 6-10M media as the chloro-complex. Depending on the acid concentration, the remaining elements are all partially extracted as xanthate complexes.  相似文献   

7.
A rapid radiochemical method has been designed for the determination of microgram quantities of zinc, based on the substoichiometric isotope dilution, using potassium ethyl xanthate as the extraction reagent. pH 5.5 in acetate buffers and chloroform as the extractant were found to be suitable for quantitative substoichiometric extraction. The influence of the diverse ions on the extraction was studied. The zinc contents of a medicinal preparation and biological samples were determined by the present method.  相似文献   

8.
A sensitive and rapid radiochemical method has been developed for the determination of microgram amounts of indium(III) based on the substoichiometric extraction of its 13 complex with potassium ethyl xanthate from pH 7 ammonia buffer into chloroform. 5–50 g of indium was determined with an average error of 1.56%. The effect of associated species on the extraction was studied.  相似文献   

9.
In this study, we investigated the kinetics of the nucleophilic substitutions, RX + (BzBu3NBr) ← → RBr + (BzBu3NX), where R = allyl, Bu and Bz, when X = Cl; and X = AcO and BzO when R = Bz. The forward and backward rate constants in addition to the activation energies for R = allyl and Bu were also determined. However, only the rate constants at 35°C were determined for the benzyl compounds with toluene as the solvent to reduce the reaction rate. Moreover, the effects of the structures of the groups R and the leaving groups X on the reactivity were compared. Results in this study can provide valuable information for future studies involving the phase transfer catalyzed displacements. © 1996 John Wiley & Sons, Inc.  相似文献   

10.
A radiochemical method has been developed for the determination of microgram amounts of cadmium based on the substoichiometric extraction of its 1:2 complex with potassium ethyl xanthate into 1:4 v/v mixture of pyridine and ethyl acetate from 2.5 M sodium formate. 10-90 micrograms of cadmium was determined with an average error of +/- 1.96%. The method developed was successfully applied to the determination of Cd contents in water samples.  相似文献   

11.
12.
A method has been developed for the extraction of Zn(II) with ethylthioacetoacetate (HETAcAc) into ethyl acetate from an alkaline medium. Various parameters affecting the extraction of Zn(II) have been investigated. The stoichiometry of the extracted species has been determined by the slope-ratio method.  相似文献   

13.
A substoichiometric radiochemical solventextraction method is described for the determination of cobalt, employing β-hydroxy-naphthaldoxime and chloroform as reagent and extractant, respectively. The extraction behaviour of the complex of cobalt with the reagent in the pH-range 8–9.5 and the effects of various metal ions on the extraction are critically studied. The method is used to determine the cobalt content in some pharmaceutical drugs. Received: 10 January 1997 / Revised: 11 March 1997 / Accepted: 25 March 1997  相似文献   

14.
A substoichiometric radiochemical solventextraction method is described for the determination of cobalt, employing β-hydroxy-naphthaldoxime and chloroform as reagent and extractant, respectively. The extraction behaviour of the complex of cobalt with the reagent in the pH-range 8–9.5 and the effects of various metal ions on the extraction are critically studied. The method is used to determine the cobalt content in some pharmaceutical drugs.  相似文献   

15.
1-Methylallyl, 1,1-dimethylallyl, 1,2-dimethylallyl, 1,3-dimethylallyl, 1,1,2-trimethylallyl, and 1-ethylallyl radicals have been generated in the gas phase at 20 ± 1°C by addition of H atoms, formed by Hg(63P1) photosensitization of H2, to appropriate dienes. Their combination reactions with ethyl radicals have been studied and the relative reactivities of the reaction centers in each allylic radical determined. Similar measurements have been made for some combination reactions of n-propyl, i-propyl, and t-butyl with 1-methylallyl and 1,1,2-trimethylallyl radicals. The more substituted reaction centers are found to be the less reactive. In addition the self-combination and disproportionation of 1-methylallyl radicals has been investigated, as has cross disproportionation of each allylic radical with ethyl. The results establish a general pattern of reactivity for these radicals, which is interpreted primarily in terms of the effects of steric interaction during reaction.  相似文献   

16.
17.
A method for quantitative extraction of zinc with potassium ethyl xanthate into carbon tetrachloride is described. The optimum conditions are: pH 5-6 and Zn(II) to reagent ~1:8 mole ratio. The effects of other ions on the extraction of Zn(2+) have been investigated, and its separation from As(3+), Pb(2+), Cu(2+) and Fe(3+)is described. The possibility of repeated use of the solvent (still loaded with xanthate after the zinc has been stripped) for further extractions (after addition of a little extra xanthate) has been explored. Various stripping agents have been examined, and the optimum conditions found.  相似文献   

18.
19.
Summary A new method for the spectrophotometric determination of bismuth, cobalt and nickel after extraction of their xanthates into molten naphthalene is described. The optimum pH values are 2.4–4.5 for Bi, 7.5–9.0 for Co, 5.5–7.5 for Ni. The naphthalene containing the metal chelates is dissolved in chloroform, and the absorbance is measured against a reagent blank at 362, 350 and 420 nm for Bi, Co and Ni and respectively. Few ions interfere and the method has been applied successfully for the determination of these metal ions in various complex materials.
Zusammenfassung Eine neue Methode für die spektrophotometrische Bestimmung von Wismuth, Kobalt und Nickel nach Extraktion ihrer Xanthate mit geschmolzenem Naphthalin wurde beschrieben. Das optimale pH für Wismut beträgt 2,4–4,5, für Kobalt 7,5–9,0 und für Nickel 5,5–7,5. Das die Metallchelate enthaltende Naphthalin wird in Chloroform gelöst und die Extinktion gegen eine Reagens-Leerlösung bei 362, 350 bzw. 420 nm für Bi, Co bzw. Ni gemessen. Nur wenige Ionen stören. Das Verfahren wurde mit Erfolg zur Bestimmung der genannten Ionen in verschiedenen komplexen Gemischen angewandt.
  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号