首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Damping gas flow was optimized for 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) determination using ion trap mass spectrometer. A tandem mass spectrometry (MS-MS) method with better than unit-mass resolution (mass width, 0.3 u) was developed at a damping gas flow of 1.5 ml/min and a collision-induced dissociation (CID) voltage of 3.30 V. The relative standard deviation (R.S.D.) at the enhanced resolution was 2.9% in 24 h of consecutive injections. The detection limit was significantly improved because the efficiency of both precursor ion trapping and fragmentation increased with the damping gas flow. Product ion yield was 4.5 times higher and limit of detection was 3.2 times lower than at the default flow (0.3 ml/min and 1.65 V).  相似文献   

2.
Due to the proteomics revolution, multi-dimensional separation and detection instruments are required to evaluate many peptides and proteins in single samples. In this study, electrospray ionization (ESI) ion mobility spectrometry (IMS) was evaluated as an additional separation after HPLC separations. Common HPLC mobile phase compositions (solvents, acid modifiers, and buffers) were assessed for the effect on ESI-IMS response. Up to 5 mM sodium phosphate, a non-volatile buffer, was able to be electrosprayed into the IMS without degradation of the instrumental performance. Due to the rapid separation times of IMS, multiple IMS spectra were obtained within a single HPLC peak. A five-peptide mixture was separated in a capillary HPLC column under isocratic conditions within 3 min. Coelution of two peaks due to non-optimal HPLC conditions occurred and these two peaks could not be distinguished by HPLC with UV detection. In contrast, the single ion mobility chromatograms provided separation of each peptide as well as providing a second degree of analyte identification (HPLC retention time and IMS mobility). Furthermore, IMS-MS analysis of the five peptides and comparison with HPLC retention times showed that each peptide had a unique retention time-ion mobility-mass to charge value. This work showed that IMS could be employed for direct separation and detection of HPLC eluents and also could be combined with HPLC-MS for three unique dimensions of separation.  相似文献   

3.
The use of CO2 as a massive and polarizable drift gas is shown to greatly improve peak‐to‐peak resolution (Rp‐p), as compared with N2, for the separation of disaccharides in a Synapt G2 traveling wave ion mobility cell. Near or baseline Rp‐p was achieved for three pairs of sodiated molecules of disaccharide isomers, that is, cellobiose and sucrose (Rp‐p = 0.76), maltose and sucrose (Rp‐p = 1.04), and maltose and lactose (Rp‐p = 0.74). Ion mobility mass spectrometry using CO2 as the drift gas offers therefore an attractive alternative for fast and efficient separation of isomeric disaccharides. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
M.T. Jafari 《Talanta》2009,77(5):1632-1639
An improved design for high resolution electrospray ionization ion mobility spectrometry (ESI-IMS) was developed by making some salient modifications to the IMS cell and its performance was investigated. To enhance desolvation of electrospray droplets at high sample flow rates in this new design, volume of the desolvation region was decreased by reducing its diameter and the entrance position of the desolvation gas was shifted to the end of the desolvation region (near the ion gate). In addition, the ESI source (both needle and counter electrode) was positioned outside of the heating oven of the IMS. This modification made it possible to use the instrument at higher temperatures, and preventing needle clogging in the electrospray process. The ion mobility spectra of different chemical compounds were obtained. The resolving power and resolution of the instrument were increased by about 15-30% relative to previous design. In this work, the baseline separation of the two adjacent ion peaks of morphine and those of codeine was achieved for the first time with resolutions of 1.5 and 1.3, respectively. These four ion peaks were well separated from each other using carbon dioxide (CO2) rather than nitrogen as the drift gas. Finally, the analytical parameters obtained for ethion, metalaxyl, and tributylamine indicated the high performance of the instrument for quantitative analysis.  相似文献   

5.
In the past decade, Ion Mobility Spectrometry has established a very strong foot hold in medical and biological applications due to its numerous advantages including sensitivity, ruggedness and reproducibility. During the analysis of complex samples such as human breath, it is very probable that two or more analytes form peak clusters due to similar drift times and pre-separation times, thus hindering the identification of the analytes. Furthermore, such overlapping of signal makes quantification very difficult or even impossible. Resolving these peak clusters is important to enable proper identification and quantification of analytes detected for diagnosis. Hence, we designed a drift tube with variable length for investigating the influence of varying drift lengths and electric field on resolution. Peak cluster formations usually seen between acetone and the reactant ion peak, between the dimer peaks of 2-Heptanone and 4-Heptanone have been resolved with the new drift tube after optimisation. These novel drift tubes could easily negate the peak clusters often encountered when complex medical and biological samples are measured with the ion mobility spectrometer. Furthermore, the fact that these drift tubes can be altered in length thereby providing a wide range of electric fields (from 50 to 3300 V.cm−1), opens up new research options in ion motions in an electric field.  相似文献   

6.
Novel experimental methods are described for controlling the levels of dopant or drift gas modifier with piezoelectric actuation. The piezoelectric jetting of 2-butanol, acetone, 4-heptanone and dichloromethane was first optimised by applying a fractional factorial experimental design to the waveform required to actuate the dopants. The concentration of dopant entering a transverse ion mobility cell was dynamically controlled by a series of air flows at the interface between the actuator and the ion source, as well as the droplet injection frequency, as defined by the optimised waveform parameters. The optimisation methodology indicated that dwell time and dwell voltage were the most important factors in controlling the process. The optimised approach was then used to deliver varying levels of candidate dopants; 20.5 to 196.6 μg?m?3 for 2-butanol, 35.4 to 164.3 μg?m?3 for acetone, 17.8 to 58.2 μg?m?3 for 4-heptanone and 27.6 to 270.2 μg?m?3 for dichloromethane. The method enables reactant ion chemistry to be switched in the order of 3 to 5 sec, indicating the potential for introducing multiple dopants at varying concentrations into ion mobility spectrometers. The most volatile material dichloromethane was more difficult to control and the reproducibility and stability of the instrument responses to this compound was not as good as the other less volatile ones. The concept of extending this approach to mixtures and dual use formulations, doping and modification was proposed.  相似文献   

7.
8.
Abu B. Kanu 《Talanta》2007,73(4):692-699
This work demonstrated the potential of using a secondary drift gas of differing polarizability from the primary drift gas for confirmation of a positive response for drugs or explosives by ion mobility spectrometry (IMS). The gas phase mobilities of response ions for selected drugs and explosives were measured in four drift gases. The drift gases chosen for this study were air, nitrogen, carbon dioxide and nitrous oxide providing a range of polarizability and molecular weights. Four other drift gases (helium, neon, argon and sulfur hexafluoride) were also investigated but design limitations of the commercial instrument prevented their use for this application. When ion mobility was plotted against drift gas polarizability, the resulting slopes were often unique for individual ions, indicating that selectivity factors between any two analytes varied with the choice of drift gas. In some cases, drugs like THC and heroin, which are unresolved in air or nitrogen, were well resolved in carbon dioxide or nitrous oxide.  相似文献   

9.
Current commercially available ion mobility spectrometers are intended for the analysis of chemicals in the gas phase. Sample introduction methods, such as direct air sampling, a GC injector or a thermal desorber, are commonly an integral part of these instruments. This paper describes an electrospray ionization ion mobility spectrometer system that allows direct introduction samples in solution phase. This allows direct analysis of non-volatile organic and biological samples, and avoids decomposition of thermally liable samples, providing reliable chemical identification. In addition, the new ion mobility spectrometer allows mobility analysis with high resolving power. Commonly used commercial IMS systems provide resolving powers between 10 and 30; this new ion mobility spectrometer has resolving power greater than 60 for routine analysis. A high resolution instrument is necessary for many applications where a complex mixture needs to be separated and quantified. This paper demonstrates the advantages of using a high resolution ion mobility spectrometer and an electrospray ionization source for the analysis of non-volatile pharmaceuticals as well as dissolved explosive in solution phase.  相似文献   

10.
A radio-frequency powered glow discharge ion source has been developed for a double-focusing mass spectrometer. The sputtering and ionization of conducting, semiconducting and insulating materials have been realized using a 13.56 MHz generator to supply the discharge operating potential. The glow discharge ion source operates stably at argon pressures of 0.1–1 hPa and radio frequency powers of 10–50 W. The influence of discharge parameters and gas inlet system on sputtering rates and ion signal intensities for semi-insulating gallium arsenide wafers has been investigated.  相似文献   

11.
This paper explains the effect of pressure on separation factor, resolving power (defined based on a single peak), and resolution (defined based on two adjacent peaks) in ion mobility spectrometry. IMS spectra were recorded at various pressures ranging from 39 hPa (29 Torr) up to atmospheric pressure and various ion gates ranging from 50 to 225 μs. The results show that the IMS peaks shift perfectly linear with pressure so that separation factors remain unaffected by pressure. However, pressure has strong influence on resolving power and resolution. Reducing pressure at constant pulse width decreases the resolving power and resolution. On the other hand, the decrease in resolution can be compensated by shortening the ion pulse width since reducing pressure results in a higher ion current.  相似文献   

12.
Tabrizchi M 《Talanta》2004,62(1):65-70
The separation efficiency of ion mobility spectrometry (IMS) may be measured in terms of either resolving power, based on a single-peak definition, or peak-to-peak resolution, based on the separation of pairs of adjacent peaks. Usually resolving power decreases with temperature. However, the experimental results show that the peak-to-peak resolution may be increased in some cases. Negative ion mobility spectra of halide ions are better resolved at elevated temperatures. In addition, the peaks corresponding to protonated monomer of amylacetate and the proton-bound dimer of ethylacetate are well separated at 100 °C while they fully overlap at 18 °C. This paper focuses on the effect of temperature on peak-to-peak resolution. It was also observed that in some cases peak-to-peak resolution decreases with temperature. Examples are the spectra of cyclohexanone and methyl-iso-butyl ketone (MIBK) as well as dimethyl methyl phosphonate (DMMP) and MIBK. The increase or decrease in resolution at elevated temperatures has been attributed to the changes in separation factor (α) which is governed by the different hydration and clustering tendency of ions.  相似文献   

13.
A key component in the design of every drift tube ion mobility spectrometer (IMS) is the ion shutter which controls the injection of ions into the drift tube. Especially, compact drift tube IMS require very short injection pulses to achieve high resolution and therefore require fast ion shutters. Thus, it is important to find an ion shutter principle that can be readily scaled towards these short injection widths without causing major non-idealities in the injection process, such as drift field inhomogeneities, ion loss and ion discrimination by mobility. In this paper, we compare different ion shutter principles, foremost the Bradbury-Nielsen gate and a field switching design. It is shown through theoretical considerations and field simulations that the Bradbury-Nielsen shutter is more universally applicable and typically less complex for long injections widths but field inhomogeneities associated with its operating principle impede the scaling process. Thus, the currently less used field switching shutters will become the superior principle when very short injection widths are required, as this shutter principle allows for single digit microsecond widths.  相似文献   

14.
In recent years, the resolving power of ion mobility instruments has been increased significantly, enabling ion mobility spectrometry (IMS) to be utilized as an analytical separation technique for complex mixtures. In theory, decreasing the drift tube temperature results in increased resolution due to decreased ion diffusion. However, the heat requirements for complete ion desolvation with electrospray ionization (ESI) have limited the reduction of temperatures in atmospheric pressure ion mobility instruments. Micro-electrospray conditions were investigated in this study to enable more efficient droplet formation and ionization with the objective of reducing drift tube temperatures and increasing IMS resolution. For small molecules (peptides), the drift tube temperature was reduced to ambient temperature with good resolution by employing reduced capillary diameters and flow rates. By employing micro-spray conditions, experimental resolution values approaching theoretically predicted resolution were achieved over a wide temperature range (30 to 250 °C). The historical heat requirements of atmospheric pressure IMS due to ESI desolvation were eliminated due to the use of micro-spray conditions and the high-resolution IMS spectra of GLY-HIS-LYS was obtained at ambient temperature. The desolvation of proteins (cytochrome c) was found to achieve optimal resolution at temperatures greater than 125 °C. This is significantly improved from earlier IMS studies that required drift tube temperatures of 250°C for protein desolvation.  相似文献   

15.
Ion mobility mass spectrometry (IM-MS) peptide mass mapping experiments were performed using a variety of drift gases (He, N2, Ar and CH4). The drift gases studied cover a range of polarizabilities ((0.2-2.6) x 10(-24) cm3) and the peak capacities obtained for tryptic peptides in each gas are compared. Although the different gases exhibit similar peak capacities (5430 (Ar) to 7580 (N2)) in some cases separation selectivity presumably based on peptide conformers (or conformer populations), is observed. For example the drift time profiles observed for some tryptic peptide ions from aldolase (rabbit muscle) show a dependence on drift gas. The transmission of high-mass ions (m/z > 2000) is also influenced by increased scattering cross-section of the more massive drift gases. Consequently the practical peak capacity for IM-MS separation cannot be assumed to be solely a function of resolution and the ability of a gas to distribute signals in two-dimensional space; rather, peak capacity estimates must account for the transmission losses experienced for peptide ions as the drift gas mass increases.  相似文献   

16.
The three most toxic coplanar PCB 77, 126 and 169 have been identified and quantified at ultra trace levels (0.02-4.8 ng/gdw) in swiss sewage sludge samples applying high resolution capillary gas chromatography (HRGC) and electron impact (EI) as well as negative ion chemical ionization (NCI) mass spectrometry (MS). NCI mass spectra have been dominated by the molecular ion as base peak and virtually no fragmentation has been observed. Detection limits of the planar PCB under single ion monitoring (SIM) conditions have been typically 100 fg for NCI-MS and 1 pg for EI-MS. NCI-MS was the preferred detection method for the determination of very low concentrations of these important contaminants in sewage sludge samples.  相似文献   

17.
The three most toxic coplanar PCB 77, 126 and 169 have been identified and quantified at ultra trace levels (0.02–4.8 ng/gdw) in swiss sewage sludge samples applying high resolution capillary gas chromatography (HRGC) and electron impact (EI) as well as negative ion chemical ionization (NCI) mass spectrometry (MS). NCI mass spectra have been dominated by the molecular ion as base peak and virtually no fragmentation has been observed. Detection limits of the planar PCB under single ion monitoring (SIM) conditions have been typically 100 fg for NCI-MS and 1 pg for EI-MS. NCI-MS was the preferred detection method for the determination of very low concentrations of these important contaminants in sewage sludge samples.  相似文献   

18.
Ion mobility spectrometry (IMS) separates ions while they travel through a buffer gas under the influence of an electrical field. The separation is affected by mass and charge but most particularly by shape (collision cross section). When coupled to MS, IMS-MS offers therefore a powerful tool for structural elucidation and isomer separation. Systematic studies aimed to compare and quantitate the effects of structural changes on drift time such as length and ramification of carbon chain, unsaturation, geometrical isomerism (cis/trans isomers for instance), cyclization and ring size are, however, scarce. Herein we used traveling wave ion mobility mass spectrometry (TWIM-MS) to systematically evaluate the relationship between structure and drift time. For that, a series of deprotonated carboxylic acids were used as model ions with a carboxylate “charge tag” for gas phase MS manipulation. Carboxylic acids showed a near linear correlation between the increase of carbon number and the increase of collision cross section (CCS). The number of double bonds changes slightly the CCS of unsaturated acids. No differences in drift time and no significant differences in CCS of cis- and trans-double bond of oleic and elaidic acids were observed. Cyclization considerably reduces the CCS. In cyclic carboxylic acids, the increase of double bonds and aromatization significantly reduces the CCS and the drift times. The use of a more polarizable drift gas, CO2, improved in some cases the separation, as for biomarker isomers of steranoic acids. The β-isomer (cis-decaline) has smaller CCS and therefore displayed lower drift time compared to the α-isomer (trans-decaline). Structural changes revealed by calculations were correlated with trends in drift times.  相似文献   

19.
This article reviews the available literature on the analysis of brominated dibenzo-p dioxins and furans (PBDD/Fs) by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS). Sample extraction and clean up, injection techniques, chromatographic separation, labelled standards and QA/QC works are discussed. Furthermore, full separation of PBDD/Fs from polybrominated diphenyl ethers (PBDEs) during clean up and control of possible chromatographic interference of PBDEs during instrumental analysis as well as possible actions to further enhance the quality of published data are discussed in detail.  相似文献   

20.
The significance of forensic arson analysis accelerates the applications of new technologies in this area. Based on the previously reported application of differential mobility spectrometry (DMS) as a detection method for gas chromatography (GC) in arson analysis, the performances of DMS and mass spectrometry (MS) were compared using a novel chemometric tool, projected difference resolutions (PDRs). The PDR results show that one-way mass spectra data exhibit higher resolution than DMS data, while total ion chromatograms from GC–DMS show higher resolution than that from GC/MS for differentiating seven kinds of ignitable liquids. Combining the information from both chromatography and spectra, two-way data always have higher resolution than one-way data for these two detection methods, and GC/MS would exhibit better performance than GC–DMS according to the minimum resolution value. To verify the PDR results, a fuzzy rule-building expert system was applied for classifying these seven kinds of ignitable liquids from fire debris based on GC–DMS and GC/MS data, respectively. The prediction accuracies were consistent with PDR results, which proved that PDR is a powerful tool in comparing the performances of different analysis methods for pattern recognition. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   