首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 859 毫秒
1.
A sensitive high-performance liquid chromatographic method with fluorescence detection to determine 3,4-methylenedioxymethamphethamine (MDMA) and 3,4-methylenedioxyamphethamine (MDA) in human and rat whole blood or plasma samples was developed by using 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) as a label. MDMA and MDA in a small amount of blood sample (ca 100 microL) were extracted by liquid-liquid extraction with ethyl acetate, and were derivatized with DIB-Cl under mild conditions (10 min at room temperature). A good separation of DIB-derivatives could be achieved within 45 min using a commercially available ODS column with an isocratic eluent of 10 mM citric acid-20 mM Na(2)HPO(4) aqueous buffer (pH 4.0)-CH(3)CN-CH(3)OH (50:45:5, v/v/v %). The calibration curves prepared with 1-methyl-3-phenylpropylamine (MPPA) as an internal standard showed good linearity (r = 0.999) with 0.36-0.83 ng/mL detection limit at a signal-to-noise ratio of 3. MDMA and MDA in rat whole blood could be monitored for 6 h after a single administration of MDMA (2.2 mg/kg, i.p.). The pharmacokinetic parameters for MDMA and MDA obtained by triplicate measurements were 426 +/- 23 and 39 +/- 6 ng/mL (C(max)), 20 +/- 5 and 100 +/- 10 min (T(max)), respectively.  相似文献   

2.
A sensitive high-performance liquid chromatographic method with fluorescence detection was developed to determine memantine (MT) in rat plasma. The method consists of pre-column labeling of MT with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) and a clean-up step with solid-phase extraction. A good separation of DIB-MT was achieved within 12 min on an octadecylsilica (ODS) column (150 × 4.6 mm i.d.; 5 μm) with a mobile phase of acetonitrile-water (70:30, v/v). The calibration curve prepared with fluoxetine as an internal standard showed good linearity in the range of 10-400 ng/mL (r = .999). The limits of detection and quantitation at signal-to-noise ratios of 3 and 10 were 2.0 and 6.6 ng/mL, respectively. The method was shown to be reliable with precisions of <5% for intra-day and <9% for inter-day as relative standard deviation. The fluorescence property and reaction yield of authentic DIB-MT were also examined. The proposed method was successfully applied to study the pharmacokinetic interaction between MT and methazolamide.  相似文献   

3.
罗宁  刘平怀  吴晓娜  陈晨  张玲  何沂飞 《色谱》2015,33(4):419-422
建立了高效液相色谱分析方法用来测定药品中乙二醇二乙醚二胺四乙酸(EGTA)含量,通过检测EGTA与Cu2+的配合物EGTA-Cu来检测EGTA。采用Ultimate-AQ C18色谱柱(250 mm×4.6 mm, 5 μm),流动相为乙腈-四丁基氢氧化铵水溶液(质量分数约0.3%四丁基氢氧化铵水溶液,醋酸调pH 6.50)-醋酸钠溶液(35 mmol/L醋酸钠,醋酸调pH 6.50)(20:20:60, v/v/v),检测波长为245 nm,流速为1.50 mL/min,柱温为40 ℃,进样量为100 μL。结果表明,EGTA质量浓度在0.10~15.00 mg/L范围内线性关系良好(R=0.9998);以信噪比(S/N)为3及10确定检出限和定量限,分别为0.05 mg/L和0.17 mg/L;样品加标平均回收率为98.34%~99.03%, RSD为1.08%~3.33%(n=9)。该方法操作简便,具有分离度好、灵敏度高、重复性好、回收率高等特点,适合药品中EGTA含量的检测,为EGTA检测提供了一种有效的检测方法。  相似文献   

4.
A sensitive and convenient high-performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS) assay is described for the (5-HT(lB/lD)) receptor agonist sumatriptan in human plasma. Sumatriptan was recovered from plasma (81.8 +/- 6.8%) by liquid-liquid extraction. The mobile phase flow rate was 0.3 mL/min and consisted of methanol:water:formic acid (90:10:0.1, v/v/v). The analytical column (4.6 x 100 mm) was packed with Partisil C(8) (5 micro m). The standard curve was linear from 0.7 to 70.4 ng/mL (r(2) > 0.99). The lower limit of quantitation was 0.7 ng/mL. The assay was specific, accurate (percentage deviation from nominal concentrations were <15%), precise and reproducible (within- and between-day coefficients of variation <10.3%). Sumatriptan in plasma was stable over three freeze/thaw cycles and at room temperature for one day. The utility of the assay was demonstrated by following sumatriptan plasma concentrations in two healthy subjects for 8-12 h following a single 20 mg intranasal dose.  相似文献   

5.
Simultaneous determination of 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA) in rat blood and brain microdialysates by high-performance liquid chromatography with fluorescence detection (HPLC-FL) was developed. Microdialysates were directly subjected to derivatization with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl). The DIB-derivatives of MDMA, MDA and the internal standard, 1-methyl-3-phenylpropylamine (MPPA), were isocratically separated on an ODS column using a mixture of 50 mm phosphate buffer (pH 7.0)-acetonitrile-methanol-2-propanol (50:45:5:2, v/v/v/v %) as an eluent at a flow rate of 1.5 mL/min. The calibration curves of MDA and MDMA spiked to blood and brain microdialysates were linear over the ranges 2.5-500 and 5.0-1000 ng/mL, respectively. The detection limits of MDA and MDMA were 1.2 and 4.2 for blood and 1.3 and 4.8 ng/mL for brain, respectively. Additionally, the intra- and the inter-assay precisions were lower than 5.6% for the blood and brain microdialysates (n = 4). The proposed method was successfully applied for the monitoring of MDMA and its metabolite MDA in rat blood and brain microdialysates, and the pharmacokinetic parameters of MDMA and MDA in the microdialysates after administration of MDMA (5 mg/kg, i.p.) with or without caffeine (20 mg/kg, i.p.) were evaluated.  相似文献   

6.
Lin YH  Chiang JF  Lee MR  Lee RJ  Ko WK  Wu SM 《Electrophoresis》2008,29(11):2340-2347
A cation-selective exhaustive injection and sweeping micellar EKC (CSEI-Sweep-MEKC) was established to analyze morphine and its four metabolites, including codeine, normorphine (NM), morphine-3-glucuronide (M3G), and morphine-6-glucuronide (M6G). After SPE, the urine samples were analyzed by this CE method. The phosphate buffer (75 mM, pH 2.5) containing 30% methanol was first filled into an uncoated fused-silica capillary (40 cm, 50 microm id), then a high-conductivity buffer (120 mM phosphate, 10.3 kPa for 99.9 s) followed. The pretreated urine sample was loaded by electrokinetic injection (10 kV, 600 s). The stacking and separation were performed by using phosphate buffer (25 mM, pH 2.5) containing 22% methanol and 100 mM SDS at -20 kV, and detected at 200 nm. During method validation, calibration plots were linear (r > or = 0.998) over a range of 30-3000 ng/mL for morphine, NM, and codeine, 100-2000 ng/mL for M6G, and 80-3200 ng/mL for M3G. The LODs (S/N = 5, sampling 600 s at 10 kV) were 10 ng/mL for morphine, NM, and codeine, 35 ng/mL for M6G, and 25 ng/mL for M3G. This stacking CE method could increase 2500-fold sensitivity of codeine, when comparing with CZE. Five addicts' urine specimens were analyzed. Their results were compared with those of LC-MS-MS, and showed good coincidence. This method could be feasible for monitoring morphine and its metabolites in forensic interest and pharmacokinetic investigations.  相似文献   

7.
An LC‐MS/MS method for the simultaneous quantitation of niacin (NA) and its metabolites, i.e. nicotinamide (NAM), nicotinuric acid (NUA) and N‐methyl‐2‐pyridone‐5‐carboxamide (2‐Pyr), in human plasma (1 mL) was developed and validated using nevirapine as an internal standard (IS). Extraction of the NA and its metabolites along with the IS from human plasma was accomplished using a simple liquid–liquid extraction. The chromatographic separation of NA, NAM, NUA, 2‐Pyr and IS was achieved on a Hypersil‐BDS column (150 ¥ 4.6 mm, 5 mm) column using a mobile phase consisting of 0.1% formic acid : acetonitrile (20:80 v/v) at a flow rate of 1 mL/min. The total run time of analysis was 2 min and elution of NA, NAM, NUA, 2‐Pyr and IS occurred at 1.37, 1.46, 1.40, 1.06 and 1.27 min, respectively. A detailed validation of the method was performed as per the FDA guidelines and the standard curves were found to be linear in the range of 100–20000 ng/mL for NA; 10–1600 ng/mL for NUA and NAM and 50–5000 ng/mL for 2‐Pyr with mean correlation coefficient of ≥0.99 for each analyte. The method was sensitive, specific, precise, accurate and suitable for bioequivalence and pharmacokinetic studies. The developed assay method was successfully applied to a pharmacokinetic study in humans. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
The development and validation of an LC-MS/MS method for the simultaneous determination of albendazole metabolites (albendazole sulfoxide and albendazole sulfone) in human plasma are described. Samples of 200 μL were extracted with ether-dichloromethane-chloroform (60:30:10, v/v/v). The chromatographic separation was performed using a C(18) column with methanol-formic acid 20 mmol/L (70:30) as the mobile phase. The method was linear in a range of 20-5000 ng/mL for albendazole sulfoxide and 10-1500 ng/mL for albendazole sulfone. For both analytes the method was precise (RSD < 12%) and accurate (RE <7%) with high recovery (>90%). The method was successfully applied to determine the plasma and cerebrospinal fluid levels of albendazole sulfoxide and albendazole sulfone in patients with subarachnoidal neurocysticercosis who received albendazole at 30 mg/kg per day for 7 days. This LC-MS/MS method yielded a quick, simple and reliable protocol for determining albendazole sulfoxide and albendazole sulfone concentrations in plasma and cerebrospinal fluid samples and is applicable to therapeutic monitoring.  相似文献   

9.
A liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of N-methyl-4-isoleucine-cyclosporin (NIM811) was developed and validated over the concentration range 1-2500 ng/mL in human whole blood using a 0.05 mL sample volume. NIM811 and the internal standard, d(12)-cyclosporin A (d(12)-CsA), were extracted from blood using MTBE via liquid-liquid extraction. After evaporation of the organic solvent and reconstitution, a 10 microL aliquot of the resulting extract was injected onto the LC-MS/MS system. Chromatographic separation of NIM811 and internal standard was performed using a Waters Symmetry RP-8 (50 x 4.6 mm, 3 microm particle size) column. The mobile phase consists of 10 mm ammonium acetate in water (A) and acetonitrile (B), with 45% B from 0 to 0.2 min, 45 to 85% B from 0.2 to 0.8 min and 85% B from 0.8 to 2.2 min. The total run time was 3.5 min with a flow rate of 0.8 mL/min. The method was validated for sensitivity, linearity, reproducibility, stability, dilution integrity and recovery. The precision and accuracy of quality control samples at low (2.00 ng/mL), medium (20.0 and 400 ng/mL) and high (2000 ng/mL) concentrations were in the range 1.1-4.3% relative standard deviation (RSD) and -2.5-10.0% (bias), respectively, from three validation runs. The method has been used to measure the exposure of NIM811 in human subjects.  相似文献   

10.
A simple and sensitive liquid chromatography–electrospray ionization–tandem mass spectrometry (LC‐ESI‐MS/MS) technique was developed and validated for the determination of sibutramine and its N‐desmethyl metabolites (M1 and M2) in human plasma. After extraction with methyl t‐butyl ether, chromatographic separation of analytes in human plasma was performed using a reverse‐phase Luna C18 column with a mobile phase of acetonitrile–10 mm ammonium formate buffer (50:50, v/v) and quantified by ESI‐MS/MS detection in positive ion mode. The flow rate of the mobile phase was 200 μL/min and the retention times of sibutramine, M1, M2 and internal standard (chlorpheniramine) were 1.5, 1.4, 1.3 and 0.9 min, respectively. The calibration curves were linear over the range 0.05–20 ng/mL, for sibutramine, M1 and M2. The lower limit of quantification was 0.05 ng/mL using 500 μL of human plasma. The mean accuracy and the precision in the intra‐ and inter‐day validation for sibutramine, M1 and M2 were acceptable. This LC‐MS/MS method showed improved sensitivity and a short run time for the quantification of sibutramine and its two active metabolites in plasma. The validated method was successfully applied to a pharmacokinetic study in human. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
A simple, robust, and rapid LC‐MS/MS method was developed for the quantitation of U0126 and validated in rat plasma. Plasma samples (20 μL) were deproteinized using 200 μL ACN containing 30 ng/mL of chlorpropamide, internal standard. Chromatographic separation performed on an Agilent Poroshell 120 EC‐C18 column (4.6 × 50 mm, 2.7 μm particle size) with an isocratic mobile phase consisting of a 70:30 v/v mixture of ACN and 0.1% aqueous formic acid. Each sample was run at 0.6 mL/min for a total run time of 2 min per sample. Detection and quantification were performed using a mass spectrometer in selected reaction‐monitoring mode with positive ESI at m/z 381 → 123.9 for U0126 and m/z 277 → 175 for the internal standard. The standard curve was linear over a concentration range of 20–5000 ng/mL with correlation coefficients greater than 0.9965. Precision, both intra‐ and interday, was less than 10.1% with an accuracy of 90.7–99.4%. No matrix effects were observed. U0126 in rat plasma degraded approximately 41.3% after 3‐h storage at room temperature. To prevent degradation, sample handling should be on an ice bath and all solutions kept at 4°C. This method was successfully applied to a pharmacokinetic study of U0126 at various doses in rats.  相似文献   

12.
建立了一种利用反相高效液相色谱-电化学阵列检测器同时检测烟草中主要次生代谢产物的方法。在Hypersil BDS C-18(4.6 mm×200 mm)色谱柱上,以30 mmol/L磷酸二氢钠(pH 3.5)-5%~70%(体积分数)乙腈(含0.25 mmol/L十二烷基磺酸钠)进行梯度洗脱,流速为1 mL/min,柱温为30 ℃。电化学阵列检测器的检测电势依次为:-20,140,210,310,400,450,490,730,800,900 mV时,可以较好地分离和检测烟草中常见的次生代谢产物绿原酸、咖啡酸、对羟基肉桂酸、莨菪葶、芦丁和烟碱。该方法的相对标准偏差为0.71%~15.31%,回收率为52.0%~85.2%,各种次生代谢产物的检测限为0.2~2 ng;进样量在20~500 ng范围内呈现良好的线性关系,线性相关系数为0.9910~0.9998;具有较高的准确度和精确度。方法简便,可应用于烟草中次生代谢产物的检测。  相似文献   

13.
A validated high-performance liquid chromatography (HPLC) method was developed for simultaneous determination and pharmacokinetic study of aloe emodin and chrysophanol in rats. It was performed on a reverse-phase C(18) column and a mobile phase made up of methanol and 0.2% acetic acid (83:17, v/v). The ultraviolet detection was 254 nm. 1,8-dihydroxyanthraquinone was used as the internal standard. The assay was linear over the range 28-2800 ng/mL (r(2) = 0.9993) for aloe emodin and 25.6-2560 ng/mL (r(2) = 0.9991) for chrysophanol. The average percentage recoveries of three spiked plasmas were 98.8-104.8% and 97.7-103.2% for aloe emodin and chrysophanol, respectively. Their RSD of intra-day and inter-day precision at concentrations of 56, 280 and 1400 ng/mL for aloe emodin and 51.6, 258 and 1290 ng/mL for chrysophanol were less than 3.5%. This method was applied for the first time to simultaneously determinate aloe emodin and chrysophanol in rats following oral administration of traditional Chinese medicine of Da-Cheng-Qi decoction. The pharmacokinetic parameters showed that chrysophanol was better absorbed with higher concentrations in plasma than aloe emodin did. They both eliminated slowly in male rats. The assay is suitable for identifying the plasma and tissue levels of aloe emodin and chrysophanol in preclinical investigations.  相似文献   

14.
An improved HPLC method was developed for the determination of piperacillin and tazobactam in human plasma and pharmacokinetic study in Chinese healthy volunteers. Piperacillin and tazobactam in human plasma were extracted by solid-phase extraction and separated on a C(18) column and detected at 220 nm. The mobile phase for piepracillin consisted of 0.01 mol/L sodium dihydrogen phosphate (pH = 4.65) and acetonitrile (71:29, v/v), and that for tazobactam was 0.05 mol/L sodium dihydrogen phosphate (pH = 4.45) and methanol (90:10, v/v). The method was linear in the range 0.25-320.00 microg/mL for piperacillin (r(2) = 0.995) and 0.25-64.00 microg/mL for tazobactam (r(2) = 0.994). The lower limit of quantification of both compounds was 0.25 microg/mL. The intra- and inter-day precisions of piperacillin and tazobactam at three concentrations were all less than 9.2% and accuracies were within the range 97.0-108.0%. The method was used to investigate the pharmacokinetics of piperacillin and tazobactam in 12 volunteers who were intravenously given a dosage of 1.25, 2.50 and 3.75 g in three periods. The results showed that piperacillin sodium-tazobactom sodium (4:1) for injection in Chinese people fits linear dynamics, and the administred dosage can be adjusted with therapeutic effect.  相似文献   

15.
A simple and sensitive analytical method based on ultraperformance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) has been developed for determination of moclobemide in human brain cell monolayer as an in vitro model of blood–brain barrier. Brucine was employed as the internal standard. Moclobemide and internal standard were extracted from cell supernatant by ethyl acetate after alkalinizing with sodium hydroxide. The UPLC separation was performed on an Acquity UPLCTM BEH C18 column (50 × 2.1 mm, 1.7 µm, Waters, USA) with a mobile phase consisting of methanol–water (29.5:70.5, v/v); the water in the mobile phase contained 0.05% ammonium acetate and 0.1% formic acid. Detection of the analytes was achieved using positive ion electrospray via multiple reaction monitoring mode. The mass transitions were m/z 269.16 → 182.01 for moclobemide and m/z 395.24 → 324.15 for brucine. The extraction recovery was 83.0–83.4% and the lower limit of quantitation (LLOQ) was 1.0 ng/mL for moclobemide. The method was validated from LLOQ to 1980 ng/mL with a coefficient of determination greater than 0.999. Intra‐ and inter‐day accuracies of the method at three concentrations ranged from 89.1 to 100.9% for moclobemide with precision of 1.1–9.6%. This validated method was successfully applied to bidirectional transport study of moclobemide blood–brain barrier permeability. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
A sensitive and specific LC-MS/MS assay for the determination of paclitaxel and its 3'p- and 6-alpha-hydroxy metabolites is presented. A 200 microL plasma aliquot was spiked with a 13C6-labeled paclitaxel internal standard and extracted with 1.0 mL tert-butylmethylether. Dried extracts were reconstituted in 0.1 M ammonium acetate-acetonitrile (1:1, v/v) and 25 microL volumes were injected onto the HPLC system. Separation was performed on a 150 x 2.1 mm C18 column using an alkaline eluent (10 mm ammonium hydroxide-methanol, 30:70, v/v). Detection was performed by positive ion electrospray followed by tandem mass spectrometry. The assay quantifies a range for paclitaxel from 0.25 to 1000 ng/mL and metabolites from 0.25 to 100 ng/mL using 200 microL human plasma samples. Validation results demonstrate that paclitaxel and metabolite concentrations can be accurately and precisely quantified in human plasma. This assay is now used to support clinical pharmacologic studies with paclitaxel.  相似文献   

17.
Blood orange juice has a high content in anthocyanins, especially represented by delphinidin-3-glucoside (D3G), cyanidin-3-glucoside (C3G) and cyanidin-3-(6-malonylglucoside) (CMG). An LC-MS/MS method for the simultaneous determination of D3G and C3G in human plasma and urine was developed and validated. After sample preparation by SPE, chromatographic separation was performed with an RP-C(18) column, using a water/methanol linear gradient. The quantitation of target compounds was determined by multiple reaction monitoring (MRM) mode, using ESI. The method showed good selectivity, sensitivity (LOD = 0.05 and 0.10 ng/mL for C3G in plasma and urine, respectively; LOD = 0.10 ng/mL for D3G in plasma and urine), linearity (0.20-200 ng/mL; r >or= 0.998), intra- and interday precision and accuracy (相似文献   

18.
A rapid, sensitive and reproducible HPLC method was developed and validated for the analysis of haloperidol and its three main metabolites in human plasma. The analysis was carried out on a monolithic silica column (Chromolith Performance RP-18e, 100 x 4.6 mm). The mobile phase consisted of sodium phosphate (0.1 m, pH 3.5)-acetonitrile (80:20, v/v) at a flow rate of 2.0 mL/min. UV detection at 230 nm was used, with the detection limits of these compounds ranging from 2 to 5 ng. The separation factors of all studied compounds were in the range 2.30-16.32, while the resolution factors were from 1.00 to 5.37.  相似文献   

19.
20.
A method for the simultaneous determination of 4(5)-methylimidazole (4MeI) and 2-acetyl-4(5)-(1,2,3,4-tetrahydroxybutyl)-imidazole (THI) was developed using SPE and HPLC/MS. Solid-phase extraction using SCX Disc cartridges was used for isolation of the analytes from liquid samples. The lower LOQwas 0.1 ng/mL for 4MeI and 0.2 ng/ mL for THI. The linearity of the calibration curves was satisfactory as indicated by correlation coefficients >0.999. The CV for the intra- and inter-day precision was <5% (n = 6); the accuracy was in the range 98-103%. The recovery was > or = 97 and > or = 98% for THI and 4MeI, respectively. The method was used to determine THI and 4MeI in beverages, coffee, caramel colours and other samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号