首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive, precise and automated non-chromatographic method for Sb(III) and Sb(V) analytical speciation based on a continuous tandem on-line separation device in connection with inductively coupled plasma-atomic emission (ICP-AES) detection is proposed. Two on-line successive separation steps are included into this method: a continuous liquid-liquid extraction of Sb(III) with ammonium pyrrolidine dithiocarbamate (APDC) into methylisobuthylketone (MIBK), followed by direct stibine generation from the organic phase. Both separation steps are carried out in a continuous mode and on-line with the ICP-AES detector. Optimization of experimental conditions for the tandem separation and ICP-AES detection are investigated in detail. Detection limits for Sb(III) were 3 ng.mL–1 and for Sb(V) 8 ng.mL–1. Precisions observed are in the range ± 5%. The proposed methodology has been applied to Sb(III) and Sb(V) speciation in sea-water samples.  相似文献   

2.
A new method of hollow fiber supported liquid membrane extraction (HF-SLME) coupled with thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) for the speciation of Sb(III) and Sb(V) in environmental and biological samples has been developed. The method is based on the complex of Sb(III) with sodium diethyldithiocarbamate (DDTC). The formed hydrophobic complex is subsequently extracted into the lumen of hollow fiber, whereas Sb(V) is remained in aqueous solutions. The extraction organic phase was injected into TS-FF-AAS for the determination of Sb(III). Total Sb concentration was determined after reduction of Sb(V) to Sb(III) in the presence of l-cysteine and the extraction procedure mentioned above. Sb(V) was calculated by subtracting of Sb(III) from the total Sb. DDTC was used as complexing reagent. 1-Octanol was immobilized in the pores of the polypropylene hollow fiber as liquid membrane and also used as the acceptor solution. Some parameters that influenced extraction and determination were evaluated in detail, such as concentration of sodium diethyldithiocarbamate (DDTC), type of organic solvent, pH of samples, stirring rates, extraction time, as well as interferences. Under optimized conditions, a detection limit of 0.8 ng mL−1 and an enrichment factor of 160 were achieved. The relative standard deviation (RSD) was 6.2% for Sb(III) (50 ng mL−1, n = 5). The proposed method was successfully applied to the speciation of Sb(III) and Sb(V) in environmental and biological samples with satisfactory results.  相似文献   

3.
A novel absorbent was prepared by dimercaptosuccinic acid chemically modifying mesoporous titanium dioxide and was employed as the micro-column packing material for simultaneous separation/preconcentration of inorganic arsenic and antimony species. It was found that both trivalent and pentavalent of inorganic As and Sb species could be adsorbed quantitatively on dimercaptosuccinic acid modified TiO2 within a pH range of 4–7, and only As(III) and Sb(III) could be quantitatively retained on the micro-column within a pH range of 10–11 while As(V) and Sb(V) were passed through the micro-column without the retention. Based on this fact, a new method of flow injection on-line micro-column separation/preconcentration coupled to inductively coupled plasma optical emission spectrometry was developed for simultaneous speciation of trace inorganic arsenic and antimony in natural waters. Under the optimized conditions, an enrichment factor of 10 and sampling frequency of 10 h− 1 were obtained with on-line mode. The detection limits of As(III), As(V), Sb(III), and Sb(V) are 0.53, 0.49, 0.77 and 0.71 ng mL− 1 for on-line mode and as low as 0.11, 0.10, 0.15 and 0.13 ng mL− 1 for off-line mode due to its higher enrichment factor (50), respectively. The relative standard deviations of two modes are less than 6.7% (C = 20 ng mL− 1, n = 7). The concentration ratio of lower oxidation states/higher oxidation states changing from 1:10 to 10:1 has no obvious effect on the recoveries of As(III) and Sb(III). In order to validate the developed method, two certified reference materials of GSBZ5004-88 and GBW(E)080545 water sample were analyzed and the determined values are in good agreement with the certified values. The proposed method was successfully applied to the simultaneous speciation of inorganic arsenic and antimony in natural waters.  相似文献   

4.
Abbaspour A  Najafi M 《Talanta》2003,60(5):1079-1084
A method for simultaneous spectrophotometric determination of Sb(III) and Sb(V) using multivariate calibration method is proposed. This method is based on the development of the reaction between the analytes and pyrogallol red at pH 2.00. The selection of variables was studied. A series of synthetic solutions containing different concentrations of Sb(III) and Sb(V) were used to check the prediction ability of the partial least squares model. The calibration curves were linear over the range of 0.3-3.4 and 0.3-3.0 μg ml−1 for Sb(III) and Sb(V), respectively. The detection limits were 0.177 and 0.200 μg ml−1 for Sb(III) and Sb(V), respectively.  相似文献   

5.
Summary A method is described for the speciation of Sb(III) and Sb(V) using HG-AAS. The efficiency of stibine generation using different pH, from Sb(III) and Sb(V) solutions, was tested. At high pH-values Sb(V) is not reduced to form stibine, Sb(III) being selectively determined. The three acids HCl, H2SO4 and H3PO4 at controlled pH were used to generate stibine, H3PO4 being the most satisfactory for antimony speciation. The interference of Sb(V) was studied for the case of Sb(III) determination with stibine generation in H3PO4 medium (pH 1.81). The speciation of Sb(III) and Sb(V) is possible up to a ratio of 1:9.  相似文献   

6.
A novel method for prevention of the oxidation of Sb(III) during sample pretreatment, preconcentration of Sb(III) and Sb(V) with nanometer size titanium dioxide (rutile) and speciation analysis of antimony, has been developed. Antimony(III) could be selectively determined by flow injection-hydride generation-atomic absorption spectrometry, coexisting with Sb(V). Trace Sb(III) and Sb(V) were all adsorbed onto 50 m g TiO2 from 500 ml solution at pH 3.0 within 15 min, then eluted by 10 ml of 5 mol/l HCl solution. One eluent was directly used for the analysis of Sb(III); to the other eluent was added 0.5 g KI and 0.2 g thiourea to reduce Sb(V) to Sb(III), then the mixture was used for the determination of total antimony. The antimony(V) content is the mathematical difference of the two concentrations. Detection limits (based on 3sigma of the blank determinations, n=11) of 0.05 ng/ml for Sb(III) and 0.06 ng/ml for Sb(V), were obtained.  相似文献   

7.
A new analytical procedure for the speciation of antimony in liver tissues is presented here. For this purpose, a flow injection system has been developed for the treatment of samples and the determination of antimony by hydride generation - atomic absorption spectrometry. The method involves the sequential and the on-line extraction of antimony(III) and antimony(V) from solid lyophilized blood and hamsters liver tissues, with 1.5 mol l(-1) acetic acid and 0.5 mol l(-1) sulfuric acid for Sb(III) and Sb(V), respectively. Reduction of Sb(V) to Sb(III) for stibine generation is effected by the on-line pre-reduction with l-cysteine. The linear ranges were 2.5-20 and 1.0-25 mug l(-1) of Sb(III) and Sb(V), respectively. The detection limits (3sigma) were 1.0 mug l(-1) for Sb(III) and 0.5 mug l(-1) for Sb(V). The relative standard deviation values for fifteen independent measurements were 2.1 and 1.8% for Sb(III) and Sb(V), respectively. The recovery studies performed with samples of cattle liver provided results from 98 to 100% for Sb(III) and from 100 to 103% for Sb(V) for samples spiked with single species. For samples spiked with both Sb(III) and Sb(V), the recovery varied from 97 to 103% for Sb(III) and from 101 to 103% for Sb(V).  相似文献   

8.
The use of 1-phenyl-3-methyl-4-benzoylpyrazolone (PMBP) as extractant for separation of Fe(III) and Fe(II) and low-temperature vaporization of the Fe(III)–PMBP chelate into ICP-AES for their speciation analysis was investigated. The factors affecting the formation of Fe(PMBP)3 chelate and its vaporization behavior were investigated in detail. PMBP was used not only as the extractant for the separation of Fe(III) and Fe(II) but also as the chemical modifier for the low-temperature ETV-ICP-AES determination of iron. Under the optimized conditions, the detection limit for iron(III) and iron(II) are both 3.2?ng/mL, with relative standard deviations of 3.9 and 4.5%, respectively. The proposed method was applied to the determination of trace iron in biological standard reference materials and the species in East Lake water samples, and the results obtained were satisfactory.  相似文献   

9.
An analytical method was developed for antimony speciation and antimony(III) preconcentration in water samples. The method is based on the selective retention of Sb(III) by modified Saccharomyces cerevisiae in the presence of Sb(V). Heat, caustic and solvent pretreatments of the biomass were investigated to improve the kinetics and thermodynamics of Sb(III) uptake process at room temperature. Heating for 30 min at 80 degrees C was defined as the optimal treatment. Antimony accumulation by the cells was independent of pH (5-10) and ionic strength (0.01-0.1 mol L(-1)). 140 mg of yeast and 2h of contact were necessary to ensure quantitative sequestration of Sb(III) up to 750 microg L(-1). In these conditions, Sb(V) was not retained. Sb(V) was quantified in sorption supernatant by inductively coupled plasma mass spectrometry (ICP-MS) or inductively coupled plasma optical emission spectrometry (ICP-OES). Sb(III) was determined after elution with 40 mmol L(-1) thioglycolic acid at pH 10. A preconcentration factor close to nine was achieved for Sb(III) when 100mL of sample was processed. After preconcentration, the detection limits for Sb(III) and Sb(V) were 2 and 5 ng L(-1), respectively, using ICP-MS, 7 and 0.9 microg L(-1) using ICP-OES. The proposed method was successfully applied to the determination of Sb(III) and Sb(V) in spiked river and mineral water samples. The relative standard deviations (n=3) were in the 2-5% range at the tenth microg L(-1) level and less than 10% at the lowest Sb(III) and Sb(V) tested concentration (0.1 microg L(-1)). Corrected recoveries were in all cases close to 100%.  相似文献   

10.
The biological activity of antimony depends on the oxidation state. The Sb(III) and Sb(V) states can be distinguished, even in the ng l?1 range, by coupling extraction with ammonium pyrrlidenedithiocarbamate into methyl isobutyl ketone (APDC/MIBK), or N-benzoyl-N-phenylhydroxylamine (BPHA) into chloroform, with anodic stripping voltammetry (a.s.v.). After complex formation with APDC in acetate-buffered medium, Sb(III), but not Sb(V), is extracted into MIBK and quantified by a.s.v. Antimony(V) is quantified in the aqueous phase after removal of Sb(III) by extraction with BPHA into chloroform from the medium acidified with nitric acid. The applicability of the proposed separation/a.s.v. method is demonstrated for samples of rain, snow and water from a dredging operation. The stability of the two antimony species is examined for natural waters with Sb(III) and Sb(V) added; possibilities of stabilization are described. The precedures should be suitable for speciation of antimony in relatively unpolluted waters.  相似文献   

11.
l-proline was immobilized on controlled pore glass to study the ability of this material for the separation and preconcentration of Sb(III) and Sb(V). The substrate was packed in a minicolumn and incorporated in a flow injection system. The effluents of the on-line solid phase extraction (before and after elution) were directly coupled to the hydride generation inductively coupled plasma optical emission spectrometry system. The effect of pH, sample (and eluent) volume, flow rates of sample loading and elution on separation of Sb(III) e Sb(V) were evaluated. Our experiments demonstrated that Sb(V) was not retained and it was selectively determined during the loading step, while retained Sb(III) was determined after elution. The proposed system was also used for the selective preconcentration of Sb(III). In this case, a preconcentration factor of 11 and a limit of detection of 90 ng L−1 for Sb(III) were achieved when 8 mL of sample were loaded into the column. The speciation analysis of inorganic Sb in river water and effluent samples was performed using the proposed method. The values obtained for total Sb (obtained by sum of Sb(III) and Sb(V)) were in good agreement with expected values. Recoveries of Sb(III) and Sb(V) in the river water Standard Reference Material 1640 (from National Institute of Standard and Technology) and spiked river waters were between 83 and 111%.  相似文献   

12.
A new method was developed for the simultaneous speciation of inorganic arsenic and antimony in water by on-line solid-phase extraction coupled with hydride generation-double channel atomic fluorescence spectrometry (HG-DC-AFS). The speciation scheme involved the on-line formation and retention of the ammonium pyrrolidine dithiocarbamate complexes of As(III) and Sb(III) on a single-walled carbon nanotubes packed micro-column, followed by on-line elution and simultaneous detection of As(III) and Sb(III) by HG-DC-AFS; the total As and total Sb were determined by the same protocol after As(V) and Sb(V) were reduced by thiourea, with As(V) and Sb(V) concentrations obtained by subtraction. Various experimental parameters affecting the on-line solid-phase extraction and determination of the analytes species have been investigated in detail. With 180 s preconcentration time, the enrichment factors were found to be 25.4 for As(III) and 24.6 for Sb(III), with the limits of detection (LODs) of 3.8 ng L− 1 for As(III) and 2.1 ng L− 1 for Sb(III). The precisions (RSD) for five replicate measurements of 0.5 μg L−1 of As(III) and 0.2 μg L−1 of Sb(III) were 4.2 and 4.8%, respectively. The developed method was validated by the analysis of standard reference materials (NIST SRM 1640a), and was applied to the speciation of inorganic As and Sb in natural water samples.  相似文献   

13.
Nanometer titanium dioxide immobilized on silica gel (immobilized nanometer-scale TiO2 particles) was prepared by a sol-gel method and characterized by X-ray diffraction and scanning electron microscopy. The adsorptive behavior of Cr(III) and Cr(VI) on immobilized nanometer TiO2 was assessed. Cr(III) was selectively sorbed on immobilized nanometer TiO2 in the pH range of 7-9, while Cr(VI) was found to remain in solution. A sensitive and selective method has been developed for the speciation of chromium in water samples using an immobilized nanometer TiO2 microcolumn and inductively coupled plasma atomic emission spectrometry. Under optimized conditions (pH 7.0, flow rate 2.0 mL/min), Cr(III) was retained on the column, then eluted with 0.5 mol/L HNO3 and determined by ICP-AES. Total chromium was determined after the reduction of Cr(VI) to Cr(III) by ascorbic acid. The adsorption capacity of immobilized nanometer TiO2 for Cr(III) was found to be 7.04 mg/g. The detection limit for Cr(III) was 0.22 ng/mL and the RSD was 3.5% (n = 11, c = 100 ng/ mL) with an enrichment factor of 50. The proposed method has been applied to the speciation of chromium in water samples with satisfactory results.  相似文献   

14.
Yu C  Cai Q  Guo ZX  Yang Z  Khoo SB 《The Analyst》2002,127(10):1380-1385
A novel and simple method for inorganic antimony speciation is described based on selective solid phase extraction (SPE) separation of antimony(III) and highly sensitive inductively coupled plasma mass spectrometric (ICP-MS) detection of total antimony and antimony(V) in the aqueous phase of the sample. Non-polar SPE cartridges, such as the Isolute silica-based octyl (C8) sorbent-containing cartridge, selectively retained the Sb(III) complex with ammonium pyrrolidine dithiocarbamate (APDC), while the uncomplexed Sb(V) remained as a free species in the solution and passed through the cartridge. The Sb(III) concentration was calculated as the difference between total antimony and Sb(V) concentrations. The detection limit was 1 ng L(-1) antimony. Factors affecting the separation and detection of antimony species were investigated. Acidification of samples led to partial or complete retention of Sb(V) on C8 cartridge. Foreign ions tending to complex with Sb(III) or APDC did not interfere with the retention behavior of the Sb(III)-APDC complex. This method has been successfully applied to antimony speciation of various types of water samples.  相似文献   

15.
The H-point standard addition method (HPSAM) was applied to kinetic data for simultaneous determination of Sb(V) and Sb(III) and also selectively determines Sb(V) in the presence of Sb(III). The method is based on the differences between rate of complexation of pyrogallol red with Sb(V) and Sb(III) at pH=2. Sb(V) can be determined in the range of 0.3-2.0 μg ml−1 with satisfactory accuracy and precision in the presence of excess Sb(III). Good selectivity was obtained over the variety of metal ions. The proposed method was used for determination of Sb(V) and Sb(III) in river and spring water samples.  相似文献   

16.
Huang X  Zhang W  Han S  Yin Y  Xu G  Wang X 《Talanta》1997,45(1):127-135
Different micellar media had different effects on the absorption spectra of the complexes of bromopyrogallol red with Sb(III) and Sb(V). The mixed micellar medium composed of 0.7 ml of 0.2% sodium dodecylsulfate (SDS) and 0.3 ml of 2% nonylphenoxypolyethoxyethanol (OP) at 80 degrees C could be used for the sensitive determination of Sb(III) in Sb(III)/Sb(V) binary mixtures. Under the optimal conditions, Beer's Law was obeyed over the range 0.1-2.3 mug ml(-1) Sb(III) with molar absorptivity at 538 nm being 4.8 x 10(4) l mol(-1) cm(-1) and detection limit 0.04 mug ml(-1). For 10 mug Sb(III), more than 100 mug Sb(V) could be tolerated (error < 3%) in the presence of SDS/OP micellar medium as compared with 0.1 mug Sb(V) in the absence of SDS/OP micellar medium. In addition, the sensitivity of Sb(III) in the micellar medium was much higher than that in pure water medium. As compared with conventional extraction spectrometry, the proposed method produced a reproducible result. It did not need the conversion of Sb(III) to Sb(V) and a time-consuming extraction process. A detailed discussion on the selection of surfactants, the effect of temperature, and the role played by the mixed surfactants were also made.  相似文献   

17.
 An on-line method for the separation and analysis of Sb(V) and Me3Sb in the presence of Sb(III) in liquid samples is described. Inorganic and organic antimony species were separated using anion-exchange high-performance liquid chromatography (HPLC) coupled with hydride generation-atomic fluorescence detection (HG-AFS). Optimum conditions for the separation of antimony species by HPLC and the hydride generation conditions for the determination by HG-AFS were established. Matrix interference of the chromatographic determination was studied in relation to MgSO4 and NaCl. The method developed was applied to the separation and determination of antimony species in spiked and natural water samples. The suitability of the method for analysis in microbial growth media and physiological studies involving methylantimony species is discussed. Received December 11, 2000. Revision April 26, 2001.  相似文献   

18.
An accurate, precise, sensitive and automated non-chromatographic method for methylmercury speciation based on a selective continuous liquid-liquid extraction of methylmercury, into xylene, as bromide and cold mercury vapour generation directly from the organic phase and final ICP-AES mercury detection is proposed. Both separation steps, liquid-liquid and gas-liquid are accomplished in a continuous mode and on line with ICP-AES as detector. The detection limit attained for methylmercury was 4ng·ml–1 (as mercury). The precision of the determination at a concentration level around 20 times the detection limit was +-5%. The proposed methodology has been applied successfully to the speciation of methylmercury and inorganic mercury in spiked sea water and spiked urine samples.  相似文献   

19.
The yeast Saccharomyces cerevisiae was immobilized in cubes of polyurethane foam and the ability of this immobilized material to separate Sb(III) and Sb(V) was investigated. A method based on sequential determination of total Sb (after on-line reduction of Sb(V) to Sb(III) with thiourea) and Sb(III) (after on-line solid–liquid phase extraction) by hydride generation inductively coupled plasma optical emission spectrometry is proposed. A flow system assembled with solenoid valves was used to manage all stages of the process. The effects of pH, sample loading and elution flow rates on solid–liquid phase extraction of Sb(III) were evaluated. Also, the parameters related to on-line pre-reduction (reaction coil and flow rates) were optimized. Detection limits of 0.8 and 0.15 μg L 1 were obtained for total Sb and Sb(III), respectively. The proposed method was applied to the analysis of river water and effluent samples. The results obtained for the determination of total Sb were in agreement with expected values, including the river water Standard Reference Material 1640 certified by the National Institute of Standards and Technology (NIST). Recoveries of Sb(III) and Sb(V) in spiked samples were between 81 ± 19 and 111 ±15% when 120 s of sample loading were used.  相似文献   

20.
The speciation of inorganic Sb(III) and Sb(V) ions in aqueous solution was studied. The adsorption behavior of Sb(III) and Sb(V) ions were investigated as iodo and ammonium pyrollidine dithiocarbamate (APDC) complexes on a column filled with Amberlite XAD-8 resin. Sb(III) and Sb(V) ions were recovered quantitatively and simultaneously from a solution containing 0.8 M NaI and 0.2 M H2SO4 by the XAD-8 column. Sb(III) ions were also adsorbed quantitatively as an APDC complex, but the recovery of the Sb(V)-APDC complex was found to be <10% at pH 5. According to these data, the concentrations of total antimony as Sb(III)+Sb(V) ions and Sb(III) ion were determined with XAD-8/NaI+H2SO4 and XAD-8/APDC systems, respectively. The Sb(V) ion concentration was calculated by subtracting the Sb(III) concentration found with XAD-8/APDC system from the total antimony concentration found with XAD-8/NaI+H2SO4 system. The developed method was applied to determine Sb(III) and Sb(V) ions in samples of artificial seawater and wastewater.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏