首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chiang JS  Huang SD 《Talanta》2008,75(1):70-75
The one-step derivatization and extraction technique for the determination of anilines in river water by dispersive liquid-liquid microextraction (DLLME) is presented. In this method the anilines are extracted by DLLME and derivatized with pentafluorobenzaldehyde (PFBAY) in aqueous solution simultaneously. In this derivatization/extraction method, 0.5 ml acetone (disperser solvent) containing 10 microl chlorobenzene (extraction solvent) and 30 g/l pentafluorobenzaldehyde (PFBAY) dissolved in methanol was rapidly injected by syringe into 5 ml aqueous sample (pH 4.6). Within 20 min the analytes extracted and derivatized were almost finished. After centrifugation, 2 microl sedimented phase containing enriched analytes was determined by GC-MS. The effects of extraction and disperser solvent type and their volume, pH value of sample solution, derivatization and extraction time, derivatization and extraction temperature were investigated. Linearity in this developed method was ranging from 0.25 to 70 microg/l, and the correlation coefficients (R2) were between 0.9955 and 0.9989, and reasonable reproducibility ranging from 5.8 to 11.8% (n=5). Method detection limits (MDLs) ranged from 0.04 to 0.09 microg/l (n=5).  相似文献   

2.
A simple, low-cost and sensitive method is demonstrated for derivatization and extraction of iodine from milk samples using hollow fiber liquid-phase microextraction (HF-LPME) and gas chromatography-electron capture detection. Iodide ions are converted to iodine under acidic medium and in the presence of an oxidant. The generated iodine reacted with 3-pentanone in extraction vial to give 2-iodo-3-pentanone and was extracted into 4 μL of 1-octanol located in the lumen of a hollow fiber. Organic solvent was selected using one variable at a time optimization method and the other main factors affecting derivatization and HF-LPME procedures were evaluated using a Taguchi’s L16 (45) orthogonal array. Under optimal conditions, the method showed low limit of detection (0.5 ng mL?1), wide linear range (1–2,000 ng mL?1) with good correlation coefficient (0.9997) and acceptable relative standard deviation (4.6 %, n = 5). Finally, the developed method was successfully applied for determination of iodide in real samples including infant milk formulas and cow milk with reasonable relative recoveries (99.8–110.5 %).  相似文献   

3.
A new method is reported for the simultaneous extraction and derivatization of amphetamine (AM) and methylenedioxyamphetamine (MDA) using headspace hollow fiber protected liquid-phase microextraction (HS-HF-LPME); quantitation is by gas chromatograph-mass spectrometry in the selected ion monitoring (SIM) mode. The derivatizing reagent, pentafluorobenzaldehyde (PFBAY), was added to the extraction solvent. The analytes, volatile and basic, were released from the sample matrix into the headspace first, then extracted and derivatized in the solvent. After that, 2 microl of extract was directly injected into the GC-MS system. Parameters affecting extraction efficiency were investigated and optimized. This method showed good linearity in the concentration range investigated (50-350 ng ml(-1) for AM and 50-700 ng ml(-1) for MDA). Excellent repeatability of the extraction (RSD< or = 4%, n=5), and low limits of quantitation (0.25 ng ml(-1) for AM and 1.00 ng ml(-1) for MDA) were achieved. The feasibility of the method was demonstrated by analyzing human urine samples.  相似文献   

4.
Trace analysis of phenolic compounds in water was performed by coupling single-drop microextraction (SDME) with in-syringe derivatization of the analytes and GC-MS analysis. The analytes were extracted from a 3ml sample solution using 2.5microl of hexyl acetate. After extraction, derivatization was carried out in syringe barrel using 0.5microl of N,O-bis(trimethylsilyl)acetamide. The influence of derivatizing reagent volume, derivatization time and temperature on the yield of the in-syringe silylation was investigated. Derivatization reaction is completed in 5min at 50 degrees C. Experimental SDME parameters, such as selection of organic solvent, sample pH, addition of salt, extraction time and temperature of extraction were studied. Analytical parameters, such as enrichment factor, precision, linearity and detection limits were also determined. The limits of detection were in the range of 4-61ng/l (S/N=3). The relative standard deviations obtained were between 4.8 and 12% (n=5).  相似文献   

5.
Dynamic liquid-phase microextraction (LPME) controlled by a programmable syringe pump was evaluated for extracting pesticides in water prior to GC-MS analysis. A conventional microsyringe with a 1.3-cm length of hollow fiber attached to its needle was connected to a syringe pump to perform the extraction. The microsyringe was used as both the microextraction device as well as the sample introduction device for GC-MS analysis. The attached hollow fiber served as the "holder" and protector" of 3 microl of organic solvent. The solvent was repeatedly withdrawn into and discharged from the hollow fiber by the syringe pump. Pesticides were extracted from 4-ml water samples into the organic solvent impregnated in the hollow fiber. The effects of organic solvents, plunger movement pattern, agitation and extraction time were investigated. Good repeatabilities of extraction performance were obtained, with the RSD values ranging from 3.0% (alachlor) to 9.8% (4-chlorophenol) for the 14 pesticides; most RSD values were under 5.0%. The method provided a 490-fold preconcentration of the target pesticides. The limits of detection were in the range of 0.01-5.1 microg/l (S/N = 3) in the GC-MS selected ion monitoring mode. In addition, sample clean-up was achieved during LPME because of the selectivity of the hollow fiber, which prevented undesirable large molecules from being extracted. A slurry sample (mixture of 40 mg soil/ml of water) containing seven pesticides was extracted using this method which also gave good linearity and precision (most RSDs <7.0%, n = 3).  相似文献   

6.
The application of dynamic hollow fiber liquid-phase microextraction (dynamic HF-LPME) and gas chromatography-mass spectrometry (GC-MS) for the determination of trace amounts of polychlorinated biphenyls (PCBs) in water was investigated. The experimental parameters were optimized. Under the optimum conditions, the concentration enrichment factors for PCBs were from 718-fold to 840-fold. The calibration curves were linear over a range of 0.05-90mug/L, with a correlation coefficient (r(2)) of 0.9957-0.9979. The relative standard deviation (RSD) ranged from 3.4% to 5.8% for intra-day variation and from 4.1% to 7.3% for inter-day variation. The limits of detection (LODs, S/N=3:1) were in the range of 13-41ng/L. The recoveries for spiked water samples ranged from 85.9% to 92.0%.  相似文献   

7.
A simple analytical procedure based on single-drop microextraction combined with in-syringe derivatization and GC-MS was developed for determination of some phenolic acids in fruits and fruit juices. Cinnamic acid, o-coumaric acid, caffeic acid, and p-hydroxybenzoic acid were used as model compounds. The analytes were extracted from a 3-mL sample solution using 2.5 microL of hexyl acetate. The extracted phenolic acids were derivatized inside the syringe barrel using 0.7 microL of N,O-bis(trimethylsilyl)acetamide before injection into the GC-MS. The influence of derivatization conditions on the yield of in-syringe silylation was studied. Experimental SDME parameters such as selection of organic solvent, solvent volume, extraction time, extraction temperature, pH, and ionic strength of the solution on the extraction performance were studied. The method provided fairly good precision for all compounds (2.4-11.9%). Detection limits were found to be between 0.6 and 164 ng/mL within an extraction time of 20 min in the GC-MS full scan mode.  相似文献   

8.
Hollow fibre-protected liquid-phase microextraction (HF-LPME) together with gas chromatography/mass spectrometry was investigated for the analysis of degradation products of chemical warfare agents in water samples. The degradation products studied were those of nerve and blister agents, and a psychotomimetic agent. Extractions were successfully performed coupled with in-situ derivatisation using a mixture of solvent and derivatising agent. The protection of the moisture-sensitive derivatising agent was afforded by the hollow fibre. Parameters such as extraction solvent, pH, salt concentration, stirring speed and extraction time were optimised using spiked deionised water samples. The linear range established was between 0.005 and 5 microg ml(-1) depending on analyte, with squared regression coefficients ranging from 0.9929 to 1.0000. Relative standard deviations ranged from 9% to 22%. As compared to those of solid-phase microextraction, the limits of detection (0.01-0.54 microg l(-1)) of the newly-developed approach were significantly improved.  相似文献   

9.
A simple and solvent-minimised sample preparation technique based on hollow fibre-protected liquid-phase microextraction was investigated for the gas chromatography/mass spectrometric analysis of chemical warfare agents in water and slurry samples. The chemical warfare agents included four nerve agents and a blister agent. Parameters such as extraction solvent, salt concentration, stirring speed and extraction time were optimised using spiked deionised water samples. The technique provided a linear range of two orders of magnitude, good repeatability (RSDs < 10%, n = 6), good linearity (r2 >or= 0.995) and limits of detection (LODs) in the range of 0.02-0.09 microg l(-1) (S/N = 3) under full scan mode. The optimised technique was also applied to more complex slurry samples and similar precision (RSD < 15%, n = 3) and limits of detection (0.02-0.2 microgl(-1), S/N = 3) were obtained.  相似文献   

10.
Jing-Shan Chiang 《Talanta》2007,71(2):882-886
Dynamic hollow fiber liquid-phase microextraction (HF-LPME) coupled with gas chromatography with flame ionization detection (GC-FID) and GC-electron capture detecion (GC-ECD) was used for quantification of toxic haloethers in lake water. The analytes were extracted from 5 ml of aqueous sample using 4 μl of organic solvent through a porous polypropylene hollow fiber. The effects on extraction performance of solvent selection, agitation rate, extraction time, extraction temperature, concentration of salt added and volumes of solvent for extraction and injection were optimized. The proposed method provided a good average enrichment factor of up to 231-fold, reasonable reproducibility ranging from 9 to 12% (n = 3), and good linearity (R2 ≧ 0.9973) for spiked water samples. Method detection limits (MDLs) ranged from 0.55 to 4.30 μg/l for FID and 0.11-0.34 μg/l for ECD (n = 7).  相似文献   

11.
In this paper, extraction kinetics was investigated experimentally and theoretically in hollow fiber liquid-phase microextraction (HF-LPME) and electromembrane extraction (EME) with the basic drugs droperidol, haloperidol, nortriptyline, clomipramine, and clemastine as model analytes. In HF-LPME, the analytes were extracted by passive diffusion from an alkaline sample, through a (organic) supported liquid membrane (SLM) and into an acidic acceptor solution. In EME, the analytes were extracted by electrokinetic migration from an acidic sample, through the SLM, and into an acidic acceptor solution by application of an electrical potential across the SLM. In both HF-LPME and EME, the sample (donor solution) was found to be rapidly depleted for analyte. In HF-LPME, the mass transfer across the SLM was slow, and this was found to be the rate limiting step of HF-LPME. This finding is in contrast to earlier discussions in the literature suggesting that mass transfer across the boundary layer at the donor–SLM interface is the rate limiting step of HF-LPME. In EME, mass transfer across the SLM was much more rapid due to electrokinetic migration. Nevertheless, mass transfer across the SLM was rate limiting even in EME. Theoretical models were developed to describe the kinetics in HF-LPME, in agreement with the experimental findings. In HF-LPME, the extraction efficiency was found to be maintained even if pH in the donor solution was lowered from 10 to 7–8, which was below the pKa-value for several of the analytes. Similarly, in EME, the extraction efficiency was found to be maintained even if pH in the donor solution increased from 4 to 11, which was above the pKa-value for several of the analytes. The two latter experiments suggested that both techniques may be used to effectively extract analytes from samples in a broader pH range as compared to the pH range recommended in the literature.  相似文献   

12.

Preconcentration followed by ultraviolet spectrophotometric determination of amoxicillin (Amox) in pharmaceuticals and water samples by using a three-phase hollow fiber microextraction technique based on carrier-mediated transport has been presented. Amox was extracted from an aqueous solution (source phase) at pH 9.0 into 1-octanol containing 5% (w/v) Aliquat-336 impregnated in the pores of a hollow fiber. It was then back-extracted into NaCl solution (pH = 4.0) which was already positioned as the receiving phase inside the lumen of the hollow fiber. The extraction took place due to the concentration gradient of the counterion between the source and the receiving phases. Under the optimized conditions, an enrichment factor of 240 and a limit of detection of 0.2 μmol L−1 were obtained. The calibration curve was linear (R2 = 0.9967) in the concentration range of 0.5–10.0 µmol L−1 Amox. The interday relative standard deviation (n = 9) and the intraday relative standard deviation (n = 3) for 1.0 × 10−6 mol L−1 Amox solution were 7.3 and 6.4%, respectively.

  相似文献   

13.
Dispersive liquid-liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) with simultaneous derivatization followed by high-performance liquid chromatography-diode array detection (HPLC-DAD) was applied for preconcentration and determination of primary and secondary aliphatic amines in environmental water samples. A ternary mixture consisting of a disperser, an extractant and a derivatization reagent was used for the simultaneous derivatization and extraction of aliphatic amines in different water samples. The effects of various experimental parameters on derivatization and extraction efficiency were studied simultaneously using experimental design. A Plackett-Burman design was performed for screening of variables in order to determine the significant variables affecting the extraction efficiency. Then, the significant factors were optimized by using a Box-Behnken design (BBD) and the response surface equations were derived. Under optimal conditions, the preconcentration factors were between 210 and 290. The limit of detections (LODs) ranged from 0.005 to 0.02 μg/L and dynamic linear ranges (DLRs) of 0.05-500 and 0.1-500 μg/L were obtained for most of analytes. The performance of the method was evaluated for extraction and determination of primary and secondary aliphatic amines in environmental water samples in micrograms per liter and satisfactory results were obtained (RSDs <12.5%).  相似文献   

14.
A simple and rapid liquid-phase microextraction (LPME) method using a hollow fiber membrane (HFM) in conjunction with gas chromatography-mass spectrometry (GC-MS) is presented for the quantitative determination of 16 polycyclic aromatic hydrocarbons (PAHs) and 12 organochlorine pesticides (OCPs) in rainwater samples. The LPME conditions were optimized for achieving high enrichment of the analytes from aqueous samples, in terms of hollow fiber exposure time, stirring rate, sample pH, and composition. Enrichment factors of more than 100 could be achieved within 35 min of extraction with relative standard deviations (R.S.D.s) 1.3-13.6% for PAHs and 1.7-13.8% for OCPs, respectively, over a wide range of analyte concentrations. Detection limits ranged from 0.002 to 0.047 microg l(-1) for PAHs, and from 0.013 to 0.059 microg l(-1) for OCPs, respectively. The newly developed LPME-GC-MS method has been validated for the analysis of PAHs and OCPs in rainwater samples. Extraction recoveries from spiked synthetic rainwater samples varied from 73 to 115% for PAHs and from 75 to 113% for OCPs, respectively. Real rainwater samples were analyzed using the optimized method. The concentrations of PAHs and OCPs in real rainwater samples were between 0.005-0.162, and 0.063 microg l(-1), respectively.  相似文献   

15.
In this paper we describe an environmentally friendly and sensitive method for the determination of ten primary amines in sewage sludge. The method is based on pressurised hot water extraction (PHWE) followed by simultaneous derivatization with pentafluorobenzaldehyde (PFBAY) and headspace solid-phase microextraction (HS-SPME) and subsequent gas-chromatography ion-trap tandem mass spectrometry (GC-IT-MS-MS) analysis. The influence of the main factors on the PHWE of sludge was optimized by a central composite design. For all species the optimal conditions were water at pH 4 as the extracting solvent, an extraction temperature of 100 °C and an extraction time of 15 min. The separation and detection of the ten amines by GC-IT-MS-MS took just 10 min and the entire process took approximately 1 h. Repeatability and reproducibility between days, expressed as RSD (%) (n = 5), were less than 19 and 24%, respectively. The average limit of detection (LOD) was of 65 μg kg−1 s (range found 9-135) and the average limit of quantification (LOQ) was of 230 μg kg−1 (range found 50-450) of dry weight (d.w.). Under optimized conditions we used this method to determine the compounds in industrial and municipal sewage sludge samples and in sludge from a potable water treatment plant. Methylamine and isobutylamine showed the highest levels in one of the industrial sewage sludge samples (404 and 543 mg kg−1 (d.w.), respectively). To our knowledge, this paper presents for the first time the determination of ten primary amines in sewage sludge samples using PHWE.  相似文献   

16.
Deng C  Yang X  Zhang X 《Talanta》2005,68(1):6-11
Panaxynol is a bioactive component in traditional Chinese medicines (TCMs), such as Saposhnikovia divaricata and Panax ginseng. In the work, two solvent-free sample techniques of pressurized hot water extraction (PHWE) and headspace liquid-phase microextraction (HS-LPME) were combined and developed for the determination of panaxynol in a TCM of S. divaricata. Panaxynol in the TCM samples from different growing areas was extracted by PHWE in dynamic mode, followed by extraction and concentration with HS-LPME and analysis with gas chromatography-mass spectrometry (GC-MS). The PHWE and HS-LPME parameters were optimized and the method validations were studied. Panaxynol in S. divaricata from four different growing areas was quantitatively analyzed by internal standard method. These results have shown that PHWE-LPME-GC-MS is a simple, rapid, efficient and low-cost method for the determination of panaxynol in TCMs and is a potential tool for TCM quality assessment.  相似文献   

17.
An automated dynamic two-phase hollow fiber microextraction apparatus combined with high-performance liquid chromatography was developed for extraction and determination of chlorophenoxy acid (CPA) herbicides from environmental samples. The extraction device, called TT-extractor, consists of a polypropylene hollow fiber mounted inside a stainless steel tube by means of two tee-connectors in flow system. An organic solvent, which fills the lumen and the pores of the hydrophobic fiber, is pumped through the fiber repeatedly and the sample is pumped along the outer side of the fiber. The factors affecting the dynamic hollow fiber liquid-phase microextraction (DHF-LPME) of target analytes were investigated and the optimal extraction conditions were established. To test the applicability of the designed instrument, CPAs were extracted from environmental aqueous samples. The limits of detection (LODs) as low as 0.5 μg/L, linear dynamic range in the range of 1-100 μg/L and the relative standard deviations of <7% were obtained. The developed method can provide perconcentration factors as large as 230. A hollow fiber membrane can be used at least 20 times with neither loss in the efficiency nor carryover of the analytes between runs. The system is cheap and convenient and requires minimal manual handling.  相似文献   

18.
A new method that involves liquid phase microextraction (LPME) with in situ derivatization and gas chromatography-mass spectrometry (GC-MS) is described for the determination of trace amounts of bisphenol A (BPA) in river water samples. The LPME conditions, such as the type of extraction solvent and the extraction time, are investigated. Then, the extract is directly injected into GC-MS. The detection limit and the quantification limit of BPA in river water sample are 2 and 10pgml(-1) (ppt), respectively. The calibration curve for BPA is linear with a correlation coefficient of >0.999 in the range of 10-10,000pgml(-1). The average recoveries of BPA in river water samples spiked with 100 and 1000pgml(-1) BPA are 104.1 (RSD: 8.9%) and 98.3 (RSD: 3.2%), respectively, with correction using the added surrogate standard, bisphenol A-(13)C(12). This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of BPA in liquid samples.  相似文献   

19.
Chen PS  Huang SD 《Talanta》2006,69(3):669-675
A technique for the analysis of organophosphorus pesticides (ethoprop, diazinon, disulfoton, fenthion) in aqueous sample using liquid-phase microextraction (LPME), coupled with gas chromatography-mass spectrometry (GC-MS) was developed. A small section of a hollow fiber inserted into the needle of GC syringe and filled with the 3.5 μl of organic solvent was used to extract pesticides from a 20 ml aqueous sample. The limits of detection (LOD) with the selected ion monitoring (SIM) mode varied from 0.2 to 0.006 μg/l. The calibration curves were linear over three orders of magnitude with R2 ≥ 0.996. The relative standard deviations of the analysis (inter- and intra-day) were 5-8%, and the relative recoveries from the lake water sample were greater than 83%. The results were compared with results obtained using solid-phase microextraction (SPME/GC/MS).  相似文献   

20.
Hollow fibre liquid-phase microextraction with in situ derivatization using dansyl chloride has been successfully developed for the high-performance liquid chromatography-ultraviolet (HPLC-UV) determination of the biogenic amines (tryptamine, putrescine, cadaverine, histamine, tyramine, spermidine) in food samples. Parameters affecting the performance of the in situ derivatization process such as type of extraction solvent, temperature, extraction time, stirring speed and salt addition were studied and optimized. Under the optimized conditions (extraction solvent, dihexyl ether; acceptor phase, 0.1 M HCl; extraction time, 30 min; extraction temperature, 26 °C; without addition of salt), enrichment factors varying from 47 to 456 were achieved. Good linearity of the analytes was obtained over a concentration range of 0.1–5 μg mL−1 (with correlation coefficients of 0.9901–0.9974). The limits of detection and quantification based on a signal-to-noise ratio of 3–10, ranged from 0.0075 to 0.030 μg mL−1 and 0.03 to 0.10 μg mL−1, respectively. The relative standard deviations based on the peak areas for six replicate analysis of water spiked with 0.5 μg mL−1 of each biogenic amine were lower than 7.5%. The method was successfully applied to shrimp sauce and tomato ketchup samples, offering an interesting alternative to liquid–liquid extraction and solid phase extraction for the analysis of biogenic amines in food samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号