首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Cholesterol oxidase (ChOx) has been immobilized onto conducting poly[2-methoxy,5-(2′-ethyl-hexyloxy)-1,4-phenylene vinylene] (MEH-PPV)/stearic acid (SA) Langmuir-Blodgett film transferred onto octadecanethiol (ODT) modified gold plate. The ChOx/MEH-PPV/SA LB film bioelectrode exhibits has been characterized by FT-IR, contact angle, and atomic force microscopy. The response of the ChOx/MEH-PPV/SA LB film bioelectrode carried out using differential pulse voltammetry (DPV) studies reveal linearity from 1.29 to 12.91 mM of cholesterol concentration and response time as 30 s. This ChOx/MEH-PPV/SA bioelectrode exhibits values of correlation coefficient as 0.9939, standard deviation as 0.0029 μA and limit of detection as 1.66 mM. UV-visible spectrophotometer studies reveal that 5.2 × 10−3 U of ChOx are actively working per cm2 area of ChOx/MEH-PPV/SA LB film bioelectrode and this bioelectrode is thermally stable upto 55 °C with reusability of about 60 times.  相似文献   

2.
Cholesterol oxidase (ChOx) and cholesterol esterase (ChEt) have been covalently immobilized onto tetraethylorthosilicate (TEOS) sol-gel films. The tetraethylorthosilicate sol-gel/ChEt/ChOx enzyme films thus prepared have been characterized using scanning electron microscopic (SEM), UV-vis spectroscopic, Fourier-transform-infrared (FTIR) spectroscopic and amperometric techniques, respectively. The results of photometric measurements carried out on tetraethylorthosilicate sol-gel/ChEt/ChOx reveal thermal stability up to 55 °C, response time as 180 s, linearity up to 780 mg dL−1 (12 mM), shelf life of 1 month, detection limit of 12 mg dL−1 and sensitivity as 5.4 × 10−5 Abs. mg−1 dL−1.  相似文献   

3.
A chitosan (CS)‐tin oxide (SnO2) nanobiocomposite film has been deposited onto an indium‐tin‐oxide glass plate to immobilize cholesterol oxidase (ChOx) for cholesterol detection. The value of the Michaelis–Menten constant (Km) obtained as 3.8 mM for ChOx/CS‐SnO2/ITO is lower (8 mM) than that of a ChOx/CS/ITO bioelectrode revealing enhancement in affinity and/or activity of ChOx towards cholesterol and also revealing strong binding of ChOx onto CS‐SnO2/ITO electrode. This ChOx/CS‐SnO2/ITO cholesterol sensor retains 95% of enzyme activity after 4–6 weeks at 4 °C with response time of 5 s, sensitivity of 34.7 μA/mg dL?1 cm2 and detection limit of 5 mg/dL.  相似文献   

4.
A nanostructured iron oxide (NanoFe3O4, particle size ca. 25 nm and roughness ca. 21 nm) film deposited onto a hydrolyzed indium‐tin‐oxide (ITO) coated glass plate has been used to immobilize cholesterol oxidase (ChOx) to fabricate an impedimetric cholesterol sensor. Electrochemical studies reveal that surface charged Fe3O4 nanoparticles provide better conformation for ChOx loading resulting in enhanced electron transfer between ChOx and the electrode. Impedimetric response studies of the ChOx/NanoFe3O4/ITO bioelectrode exhibit improved linearity (2.5–400 mg/dL), low detection limit (0.25 mg/dL), fast response time (25 s), high sensitivity (86 Ω/mg dL?1/cm?2) and a low value of the Michaelis‐Menten constant (Km, 0.8 mg/dL) with a regression coefficient of 0.997.  相似文献   

5.
Fabrication of an amperometric cholesterol biosensor by co-immobilization of cholesterol esterase (ChEt) and cholesterol oxidase (ChOx) onto conducting polypyrrole (PPY) films using electrochemical entrapment technique is described. Electrochemical polymerization was carried out using a two-electrode cell configuration at 0.8 V. Characterization of resulting amperometric biosensor for the estimation of cholesterol has been experimentally determined in terms of linear response range, optimum pH, applied potential, temperature, and shelf-life. These PPY/ChEt/ChOx electrodes can be used for cholesterol ester estimation from 1 to 8 mM and have shelf-life of about 4 weeks at 4 °C during which about 15 estimations of cholesterol ester could be made. The sensitivity of PPY/ChEt/ChOx electrode has been found to be 0.15 μA/mM and the apparent Km value for this electrode is 9.8 mM. Conductivity of the polymer films found to be about 3×10−3 S/cm.  相似文献   

6.
Cholesterol oxidase (ChOx) has been immobilized onto sol–gel derived nano-structured cerium oxide (NS-CeO2) film deposited on indium-tin-oxide (ITO) coated glass substrate. Phase identification of sol–gel NS-CeO2 film carried out using X-ray diffraction (XRD) yields reflection peak at 29.4° corresponding to (1 1 1) plane with oriented crystallite (34 nm) along c-axis normal to the substrate. Electrochemical studies reveal that NS-CeO2 provides electroactive surface for the loading of ChOx and enhances electron transfer rate in the ChOx/NS-CeO2/ITO bioelectrode. The low value of Michaelis–Menten constant (Km) obtained as 2.08 mM indicates enhanced ChOx affinity to cholesterol. The observed results show application of sol–gel derived NS-CeO2 for biosensing without any functionalization.  相似文献   

7.
We report a novel composite electrode made of chitosan‐SiO2‐multiwall carbon nanotube (CHIT‐SiO2‐MWNT) composite coated on the indium‐tin oxide (ITO) glass substrate. Cholesterol oxidase (ChOx) was covalently immobilized on the CHIT‐SiO2‐MWNT/ITO electrode that resulted in a ChOx/CHIT‐SiO2‐MWNT/ITO cholesterolactive bioelectrode. The CHIT‐SiO2‐MWNT/ITO and ChOx/CHIT‐SiO2‐MWNT/ITO electrodes were characterized with Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The influence of various parameters was investigated, including the applied potential, pH of the medium, and the concentration of the enzyme on the performance of the biosensor. The cholesterol bioelectrode exhibited a sensitivity of 3.4 nA/ mgdL?1 with a response time of five seconds. The biosensor using ChOx/CHIT‐SiO2‐MWNT/ITO as the working electrode retained its original response after being stored for six months. The biosensor using ChOx/CHIT‐SiO2‐MWNT/ITO as the working electrode showed a linear current response to the cholesterol concentration in the range of 50–650 mg/dL.  相似文献   

8.
Octadecanethiol (ODT) self-assembled monolayer (SAM) prepared onto gold-coated glass plate has been modified by using nitrene reaction of 1-fluoro-2-nitro-4-azidobenzene (FNAB) that further covalently binds to cholesterol oxidase (ChOx) via thermal reaction. FNAB acts as a bridge (cross-linker) between SAM and ChOx. The ChOx/FNAB/ODT/Au electrode thus fabricated has been characterized using contact angle (CA) measurements, UV-vis spectroscopy, electrochemical techniques and X-ray photoelectron spectroscopy (XPS) technique, respectively. This ChOx/FNAB/ODT/Au bioelectrode has been utilized for estimation of cholesterol in solution using surface plasmon resonance (SPR) technique. This SPR based cholesterol biosensor has linearity from 50 to 500 mg/dl of cholesterol in solution with lower detection limit of 50 mg/dl and shelf life of about 2 months when stored at 4 °C.  相似文献   

9.
Polyaniline nanotube (PANI-NT) based films have been fabricated onto indium-tin-oxide (ITO) coated glass plates via electrophoretic technique. These PANI-NT/ITO electrodes have been utilized for covalent immobilization of cholesterol oxidase (ChOx) using glutaraldehyde (Glu) as cross-linker. Structural, morphological and electrochemical characterization of PANI-NT/ITO electrode and ChOx/Glu/PANI-NT/ITO bioelectrode have been done using FT-IR spectroscopy, SEM, electrochemical impedance spectroscopy and cyclic voltammetry techniques. Response studies of the ChOx/Glu/PANI-NT/ITO bioelectrode have been carried out using both linear sweep voltammetry and UV-Visible spectrophotometry. The results of the biosensing studies reveal that this bioelectrode can be used to detect cholesterol in wide detection range of 25-500 mg/dL with high sensitivity of 3.36 mA mg(-1) dL and fast response time of 30 s at pH 7.4. This bioelectrode exhibits very low value of Michaelis-Menten constant of 1.18 mM indicating enhanced interactions between cholesterol and ChOx immobilized onto this nanostructured PANI matrix.  相似文献   

10.
A novel paper-based analytical device (PAD) coupled with a silver nanoparticle-modified boron-doped diamond (AgNP/BDD) electrode was first developed as a cholesterol sensor. The AgNP/BDD electrode was used as working electrode after modification by AgNPs using an electrodeposition method. Wax printing was used to define the hydrophilic and hydrophobic areas on filter paper, and then counter and reference electrodes were fabricated on the hydrophilic area by screen-printing in house. For the amperometric detection, cholesterol and cholesterol oxidase (ChOx) were directly drop-cast onto the hydrophilic area, and H2O2 produced from the enzymatic reaction was monitored. The fabricated device demonstrated a good linearity (0.39 mg dL−1 to 270.69 mg dL−1), low detection limit (0.25 mg dL−1), and high sensitivity (49.61 μA mM−1 cm−2). The precision value for ten replicates was 3.76% RSD for 1 mM H2O2. In addition, this biosensor exhibited very high selectivity for cholesterol detection and excellent recoveries for bovine serum analysis (in the range of 99.6–100.8%). The results showed that this new sensing platform will be an alternative tool for cholesterol detection in routine diagnosis and offers the advantages of low sample/reagent consumption, low cost, portability, and short analysis time.  相似文献   

11.
The nanocomposite electrode comprising of polypyrrole (PPY) and carboxy functionalized multiwalled carbon nanotubes (MWCNT) has been electrochemically fabricated onto indium–tin–oxide (ITO) electrode using p‐toluene sulfonic acid (PTS). Cholesterol oxidase (ChOx) and cholesterol esterase (ChEt) have been immobilized onto this PPY– MWCNT/ITO nanocomposite electrode using N‐ethyl‐N‐(3‐dimethylaminopropyl) carbodiimide and N‐hydroxy succinimide chemistry for estimation of esterified cholesterol. The ChEt–ChOx/PPY–MWCNT/PTS/ITO bioelectrode has been characterized using Fourier transform infrared spectroscopy, electrochemical techniques, and scanning electron microscope. This ChEt–ChOx/PPY–MWCNT/PTS/ITO nanobioelectrode has a response time of about 9 s, linearity of 4 × 10?4 to 6.5 × 10?3 M/l of cholesterol oleate concentration, Km of 0.02 mM, and thermal stability of upto 45°C. This electrode exhibits improved biosensing characteristics compared with other total cholesterol electrodes reported in literature till date and can be used to estimate cholesterol in blood serum samples. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
RF sputtered p-type nickel oxide (NiO) thin film exhibiting tunable semiconductor character which in turns enhanced its functional properties. NiO thin film with high hole mobility is developed as a potential matrix for the realization of glucose biosensor. NiO thin film prepared under the optimized deposition conditions offer good electrical conductivity (1.5 × 10−3 Ω−1-cm−1) with high hole mobility (2.8 cm2 V−1 s−1). The bioelectrode (GOx/NiO/ITO/glass) exhibits a low value of Michaelis–Menten constant (Km = 1.05 mM), indicating high affinity of the immobilized GOx toward the analyte (glucose). Due to the high surface coverage (2.32 × 10−7 mol cm−2) of the immobilized enzyme on to the NiO matrix and its high electrocatalytic activity, the prepared biosensor exhibits a high sensitivity of 0.1 mA (mM−1-cm−2) and a good linearity from 25 to 300 mg dL−1 of glucose concentration with fast response time of 5 s. Various functional properties of the material (mobility, crystallinity and stress) are found to influence the charge communication feature of NiO thin film matrix to a great extent, resulting in enhanced sensing response characteristics.  相似文献   

13.
Shi H  Yang Y  Huang J  Zhao Z  Xu X  Anzai J  Osa T  Chen Q 《Talanta》2006,70(4):852-858
An amperometric choline biosensor was developed by immobilizing choline oxidase (ChOx) in a layer-by-layer (LBL) multilayer film on a platinum (Pt) electrode modified with Prussian blue (PB). 6-O-Ethoxytrimethylammoniochitosan chloride (EACC) was used to prepare the ChOx LBL films. The choline biosensor was used at 0.0 V versus Ag/AgCl to detect choline and exhibited good characteristics such as relative low detection limit (5 × 10−7 M), short response time (within 10 s), high sensitivity (88.6 μA mM−1 cm−2) and a good selectivity. The results were explained based on the ultrathin nature of the LBL films and the low operating potential that could be due to the efficient catalytic reduction of H2O2 by PB. In addition, the effects of pH, temperature and applied potential on the amperometric response of choline biosensor were evaluated. The apparent Michaelis-Menten constant was found to be (0.083 ± 0.001) ×10−3 M. The biosensor showed excellent long-term storage stability, which originates from a strong adsorption of ChOx in the EACC multilayer film. When the present choline biosensor was applied to the analysis of phosphatidylcholine in serum samples, the measurement values agreed satisfactorily with those by a hospital method.  相似文献   

14.
Cholesterol oxidase (ChOx) has been covalently linked to Langmuir-Blodgett (LB) monolayers of polyaniline (PANI)-stearic acid (SA) prepared onto indium-tin-oxide (ITO) coated glass plates via glutaraldehyde (Glu) chemistry. These ChOx/Glu/PANI-SA LB film/ITO electrodes have been characterized by FT-IR, cyclic voltammetry, and scanning electron microscopy, respectively. The results of response measurements carried out on these bioelectrodes using linear sweep voltammetry (LSV) reveal linearity from 25 to 400 mg/dL of cholesterol concentration with sensitivity of 88.9 nA mg(-1) dL. The linear regression analysis of bioelectrode reveals standard deviation and correlation coefficient of 0.737 microA and 0.9988, respectively. The low value of the Michaelis-Menten constant of these bioelectrodes obtained as 1.21 mM for the immobilized enzyme indicates increased interaction between ChOx and cholesterol in the PANI-SA LB film.  相似文献   

15.
Fabrication of an amperometric-rotating biosensor for the enzymatic determination of cholesterol is reported. The assay utilizes a combination of three enzymes: cholesterol esterase (ChE), cholesterol oxidase (ChOx) and peroxidase (HRP); which were co-immobilizing on a rotatory disk. The method is developed by the use of a glassy carbon electrode as detector versus Ag/AgCl/3 M NaCl in conjunction with a soluble-redox mediator 4-tert-butylcatechol (TBC). ChE converts esterified cholesterol to free cholesterol, which is then oxidized by ChOx with hydrogen peroxide as product. TBC is converted to 4-tert-butylbenzoquinone (TBB) by hydrogen peroxide, catalyzed by HRP, and the glassy carbon electrode responds to the TBB concentration. The system has integrated a micro packed-column with immobilized ascorbate oxidase (AAOx) that works as prereactor to eliminate l-ascorbic acid (AA) interference. This method could be used to determine total cholesterol concentration in the range 1.2 μM-1 mM (r = 0.999). A fast response time of 2 min has been observed with this amperometric-rotating biosensor. Lifetime is up to 25 days of use. The calculated detection limits was 11.9 nM. Reproducibility assays were made using repetitive standards solutions (n = 5) and the percentage standard error was less than 4%.  相似文献   

16.
α-Fe2O3 nanoparticles prepared using a simple solution-combusting method have been dispersed in chitosan (CH) solution to fabricate nanocomposite film on glass carbon electrode (GCE). The as-prepared α-Fe2O3 nanoparticles were characterized by powder X-ray diffraction (XRD), scanning electron microscopy (SEM). The nanocomposite film exhibits high electrocatalytic oxidation for nitric oxide (NO) and reduction for hydrogen peroxide (H2O2). The electrocatalytic oxidation peak is observed at +0.82 V (vs. Ag/AgCl) and controlled by diffusion process. The electrocatalytic reduction peak is observed at −0.45 V (vs. Ag/AgCl) and controlled by diffusion process. This α-Fe2O3-CH/GCE nanocomposite bioelectrode has response time of 5 s, linearity as 5.0 × 10−7 to 15.0 × 10−6 M of NO with a detection limit of 8.0 × 10−8 M and a sensitivity of −283.6 μA/mM. This α-Fe2O3-CH/GCE nanocomposite bioelectrode was further utilized in detection of H2O2 with a detection limit of 4.0 × 10−7 M, linearity as 1.0 × 10−6 to 44.0 × 10−6 M and with a sensitivity of 21.62 μA/mM. The shelf life of this bioelectrode is about 6 weeks under room temperature conditions.  相似文献   

17.
Iron oxide nanoparticles of size ~10 nm have been encapsulated into four nanometer thick shells of Prussian blue and were then electrophoretically deposited onto an indium tin oxide substrate. The immobilization of cholesterol oxidase has been done onto the nanostructured film to investigate the kinetic parameters and biosensing characteristics. The fabricated bioelectrode exhibits an electron transfer coefficient and a charge transfer rate constant of 0.45 and 45.15 s?1, respectively. Direct electron transfer properties of the nanostructured film result in 3rd generation cholesterol biosensor. The bioelectrode exhibits high sensitivity (2.15 mAM?1 cm?2), a low Kmapp value (0.07 mM), good stability and high selectivity towards cholesterol.  相似文献   

18.
Cholesterol oxidase (ChOx), cholesterol esterase (ChEt), and horseradish peroxidase (HRP) have been co-immobilized covalently on a self-assembled monolayer (SAM) of N-(2-aminoethyl)-3-aminopropyltrimethoxysilane (AEAPTS) deposited on an indium–tin–oxide (ITO) glass surface. These enzyme-modified (ChOx-ChEt-HRP/AEAPTS/ITO) biosensing electrodes have been used to estimate cholesteryl oleate from 10 to 500 mg dL−1. The sensitivity, K m value, and shelf-life of these ChEt-ChOx-HRP/AEAPTS/ITO biosensing electrodes have been found to be 124 nA mg−1 dL, 95.098 mg dL−1 (1.46 mmol L−1), and ten weeks, respectively. The ChEt-ChOx-HRP/AEAPTS/ITO bio-electrodes have been used to estimate total cholesterol in serum samples. Figure Covalent immobilization of enzymes onto AEAPTS/ITO surface using EDC/NHS chemistry Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

19.
The rapidly increasing demand for cultured fish as a food resource requires simple, effective methods for controlling fish health in culture conditions. Plasma total cholesterol levels are significantly related to fish mortality following bacterial challenge, and are thus a good indicator of the general health of fish. We developed a wireless biosensor system to continuously monitor the total cholesterol concentration in fish (Nile tilapia, Oreochromis niloticus). The biosensor was constructed with Pt-Ir wire (φ0.178 mm) as the working electrode and Ag/AgCl paste as the reference electrode. Cholesterol oxidase and cholesterol esterase were immobilized on the working electrode using glutaraldehyde. The sensor output was linear and strongly correlated with the cholesterol level (R = 0.9970) in the range of 2.65-403 mg dl−1. This range covers the range of total cholesterol levels in fish. To avoid blood coagulation and proteins coalescing on the sensor, we implanted the sensor in the fluid under the scleral surface of the eyeball (EISF). The EISF is presumed to reflect the levels of most blood components and does not include the substances contained in blood that inhibit sensor measurement. Total cholesterol concentrations in blood and EISF were strongly correlated (R = 0.8818, n = 72) in the blood total cholesterol range of 74-480 mg dl−1. Therefore, we used EISF as an alternative to blood and performed continuous in vivo-monitoring of the total cholesterol concentration in fish. We also investigated the application of the calibration method and wireless monitoring system. These applications enabled us to securely monitor total cholesterol levels in free-swimming fish in an aquarium for over 40 h. Thus, our newly developed sensor provided a rapid and convenient method for real-time monitoring of total cholesterol concentrations in free-swimming fish.  相似文献   

20.
Three cholesterol biosensor configurations based on the formation of a layer of Prussian-Blue (PB) on a Pt electrode for the electrocatalytic detection of the H2O2 generated during the enzymatic reaction of cholesterol with cholesterol oxidase (ChOx) were constructed. The enzyme was entrapped within a polypyrrole (PPy) layer electropolymerized onto the PB film. The influence of the formation of self-assembled monolayers (SAMs) on the Pt surface on the adherence and stability of the PB layer and the formation of an outer layer of nafion (Nf) as a means of improving selectivity were both studied. A comparative study was made of the analytical properties of the biosensors corresponding to the three configurations named: Pt/PB/PPy-ChOx, Pt/SAM/PB/PPy-ChOx and Pt/SAM/PB/PPy-ChOx/Nf. The sensitivity (from 600 to 8500 nA mM−1 cm−2) and selectivity of the developed biosensors permitted the determination of the cholesterol content in reference and synthetic serum samples. The detection limit for the Pt/SAM/PB/PPy-ChOx/Nf biosensor was 8 μM. Formation of the SAM on the electrode surface and covering with a Nf film considerably improved the stability and lifetime of the biosensor based on the catalytic effect of the PB layer (as the PB layer was retained longer on the electrode), and the Nf layer protects the enzyme from the external flowing solutions. Lifetime is up to 25 days of use. The formation of the SAM also has an effect on the charge transfer and the formation of the PB layer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号