首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
There is an ongoing debate regarding the mechanism of Pt electrochemical dissolution. However, only off-line methods have so far been used, where separation of Pt species is performed separately from their detection. In this study, ion exchange chromatography coupled to inductively coupled plasma mass spectrometry was used for the first time to separate and detect Pt species generated by the electro-dissolution of a Pt electrode in 0.5 M aqueous H2SO4 solution. Because these species are either neutral or cationic, they were converted to chloro-complexes using 0.1 M KCl to enable their separation by anion exchange chromatography. Chloro-aqua complexes were observed in addition to the two predominant species, namely PtCl42− and PtCl62−. A good linear relationship was observed between the sum of peak areas for all complexes of a given Pt oxidation state and the Pt concentration, with a detection limit of 0.1 μg L−1 being reached for Pt(II) and Pt(IV). Application of this speciation analysis method to real samples generated by potential cycling using cyclic voltammetry (CV) revealed that, in general, at least 80% of Pt was present as Pt(II), irrespectively of the cyclic potential range or of temperature (up to 60 °C). Still, quantitative spike recovery was achieved after adding known amounts of Pt(II) or Pt(IV) to a sample prepared by CV, which demonstrated that no significant species inter-conversion took place.  相似文献   

2.
In this contribution, a novel method is described for the determination of platinum metals. The procedure developed employs a carbon paste electrode modified in situ with cationic surfactants of the quaternary ammonium salt type. The pre-concentration step is based on a specific accumulation mechanism involving ion-pair formation; the detection being performed by cathodic scanning in the differential pulse voltammetric mode. Regarding the individual forms of platinum metals, the method has been found convenient for the determination of three heavy platinum metals in the form of Pt(IV), Ir(III) and Os(IV), whereas for the remaining elements (Ru, Rh, and Pd) was almost inapplicable. Platinum metals of the former group can be pre-concentrated in chloride-containing supporting media via PtCl62−, IrCl63− and OsCl62− complex anions, the central atom of each species being fairly reducible during the voltammetric scan. Stripping signals for both platinum and iridium were proportional to the concentration in a range of 1-10 × 10−6 M Pt(IV) and Ir(III); the response for osmium being linear within 0.1-6 × 10−7 M Os(IV) with a detection limit of about 5 × 10−9 mol l−1. During optimisation, special attention was paid to the accumulation mechanism, choice of key experimental conditions, and to interference effects from foreign ions with potentially ion-pairing capabilities (AuCl4, TlCl4, CrO42−, MnO4, SCN, and I). The method elaborated has been tested on both model solutions and real samples of industrial waste water, showing in both cases satisfactory analytical performance.  相似文献   

3.
Wittaya Ngeontae 《Talanta》2009,78(3):1004-630
Chemically modified silica containing amidoamidoxime group was studied as a sorbent for solid-phase extraction (SPE) and preconcentration of Cu(II) prior to determination by flame atomic absorption spectrometry (FAAS). The sorbent showed an extremely high selectivity towards Cu(II) in the pH range of 4-6, while the extraction of Pb(II), Cd(II), Ni(II) and Co(II) was low. The adsorption isotherm followed the Langmuir model and the maximum sorption capacity of 0.0163 mmol Cu(II) g−1 was achieved. In the flow system, Cu(II) was completely retained on a column containing 40 mg of the modified silica at the flow rate of 4.0 mL min−1 and quantitatively eluted by 5 mL of 1% (v/v) HNO3. No interference from Na+, K+, Mg2+, Ca2+, Cl and SO42− at 10, 100 and 1000 mg L−1 was observed. When applied for preconcentration and determination of Cu(II) in tap water, pond water, and seawater, the recoveries were 96, 101, and 95%, respectively, with high precision (% relative standard deviation (R.S.D.) < 4) and low method detection limit (9 μg L−1).  相似文献   

4.
Enass M. Ghoneim 《Talanta》2010,82(2):646-652
A simple and precise square-wave adsorptive cathodic stripping voltammetry (SW-AdCSV) method has been described for simultaneous determination of Mn(II), Cu(II) and Fe(III) in water samples using a carbon paste electrode. In 0.1 mol L−1 acetate buffer (pH 5) containing 50 μmol L−1 of 2-(5′-bromo-2′-pyridylazo)-5-diethylaminophenol (5-Br-PADAP), Mn(II), Cu(II) and Fe(III) were simultaneously determined as metal-complexes with 5-Br-PADAP following preconcentration onto the carbon paste electrode by adsorptive accumulation at +1.0 V (vs. Ag/AgCl/3 M KCl). Insignificant interference from various cations (K+, Na+, Mg2+, Ca2+, Al3+, Bi3+, Sb3+, Se4+, Zn2+, Ni2+, Co2+, Cd2+, Pb2+, V5+, Ti4+ and NH4+), anions (HCO3, Cl, NO3−, SO42− and PO43−) and ascorbic acid was noticed. Limits of detection of 0.066, 0.108 and 0.093 μg L−1 and limits of quantitation of 0.22, 0.36 and 0.31 μg L−1 Mn(II), Cu(II) and Fe(III), respectively, were achieved by the described method. The described stripping voltammetry method was successfully applied for simultaneous determination of Mn(II), Cu(II) and Fe(III) in ground, tap and bottled natural water samples.  相似文献   

5.
Electrochemical behavior of hexafluoroniobate (Nb(V)F6), heptafluorotungstate (W(VI)F7), and oxotetrafluorovanadate (V(V)OF4) anions has been investigated in N-butyl-N-methylpyrrolidinium bis(trifluoromethylsulfonyl)amide (BMPyrTFSA) ionic liquid at 298 K by means of cyclic voltammetry and chronoamperometry. Cyclic voltammograms at a Pt electrode showed that Nb(V)F6 anion is reduced to Nb(IV)F62− by a one-electron reversible reaction. Electrochemical reductions of W(VI)F7 and V(V)OF4 anions at a Pt electrode are quasi-reversible and irreversible reactions, respectively, according to cyclic voltammetry. The diffusion coefficients of Nb(V)F6, W(VI)F7 and V(V)OF4 determined by chronoamperometry are 1.34 × 10−7, 7.45 × 10−8 and 2.49 × 10−7 cm2 s−1, respectively. The Stokes radii of Nb(V)F6, W(VI)F7, and V(V)OF4 in BMPyrTFSA have been calculated to be 0.23, 0.38, and 0.12 nm, from the diffusion coefficients and viscosities obtained.  相似文献   

6.
Matsumiya H  Iki N  Miyano S 《Talanta》2004,62(2):337-342
Sulfonylcalix[4]arenetetrasulfonate (SO2CAS) has been examined as a pre-column chelating reagent for ultratrace determination of metal ions by ion-pair reversed-phase high-performance liquid chromatography with spectrophotometric detection. Metal ions were converted into the SO2CAS chelates in an acetic buffer solution (pH 4.7). The chelates were injected onto a n-octadecylsilanized silica-type Chromolith™ Performance RP-18e column and were eluted using a methanol (50 wt.%)-water eluent (pH 5.6) containing tetra-n-butylammonium bromide (7.0 mmol kg−1), acetate buffer (5.0 mmol kg−1), and disodium ethylendiamine-N,N,N′,N′-tetraacetate (0.10 mmol kg−1). Under the conditions used, Al(III), Fe(III), and Ti(IV) were selectively detected among 21 kinds of metal ions [Al(III), Ba(II), Be(II), Ca(II), Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Ga(III), Hf(IV), In(III), Mg(II), Mn(II), Mo(VI), Ni(II), Pb(II), Ti(IV), V(V), Zn(II), and Zr(IV)]. The detection limits on a 3σ blank basis were 8.8 nmol dm−3 (0.24 ng cm−3) for Al(III), 7.6 nmol dm−3 (0.42 ng cm−3) for Fe(III), and 17 nmol dm−3 (0.80 ng cm−3) for Ti(IV). The practical applicability of the proposed method was checked using river and tap water samples.  相似文献   

7.
A flow solid phase extraction procedure based on biosorption of Pt(IV) and Pd(II) on Aspergillus sp. immobilized on cellulose resin Cellex-T was proposed for the separation and preconcentration of Pt and Pd before their determination by electrothermal atomic absorption spectrometry (ETAAS). The analytical conditions including sample pH, eluent type, flow rates of sample and eluent solutions were examined. The analytes were selectively retained on the biosorbent in acidic medium (pH 1) and subsequently eluted from the column with 1 mL of thiourea solution (0.25 mol L− 1 thiourea in 0.3 mol L− 1 HCl). The reproducibility of the procedure was below 5%. The limit of detection of the method was 0.020 ng mL− 1 for Pt and 0.012 ng mL− 1 for Pd. The method validation was performed by analysis of certified reference materials BCR-723 (tunnel dust) and SARM-76 (platinum ore). The developed separation procedure was applied to the determination of Pt and Pd in road dust samples by ETAAS.The applied biosorbent is characterized by high sorption capacity: 0.47 mg g− 1 for Pt and 1.24 mg g− 1 for Pd.  相似文献   

8.
A new microflow injection chemiluminescence (μFI-CL) system was described for the determination of cisplatin in human serum. By using the microchip with double spiral channel configuration, the sensitivity was greatly enhanced due to more efficient mixing of the analyte and reagent solutions. Experimental results revealed that common ions in human serum, such as Mn2+, Co2+, Fe3+, Cu2+, Zn2+, Ni2+, Na+, K+, Ca2+, Cl, NO3, Ac, CO32−, PO43−, SO42− did not cause interference with the detection of Pt(II) by using 1,10-phenanthroline as the masking agent. Under the optimized conditions, a linear calibration curve (R2 = 0.998) over the range 2.0 × 10−8 to 2.0 × 10−6 mol L−1 was obtained with the detection limit of 1.24 × 10−9 mol L−1. The relative standard deviation was found to be 3.46% (n = 12) for 2.0 × 10−7 mol L−1. The sample consumption was only 2 μL with the sample throughput of 72 h−1. It had been used for trace platinum determination in cisplatin injection and human serum samples after the dosage of cisplatin. The recovery varied from 97.6 to 103.9%. The results proved that the proposed μFI-CL system had the advantages of high sensitivity and precision, low sample and reagents consumption, and high analytical throughput.  相似文献   

9.
A plasticized poly (vinyl chloride) membrane electrode based on 1,3-bis(2-cyanobenzene)triazene (CBT) for highly selective determination of platinum(II) (in PtCl42− form) is developed. The electrode showed a good Nernstian response (29.8 ± 0.3 mV decade−1) over a wide concentration range (1.0 × 10−6 to 1.0 × 10−2 mol L−1). The limit of detection was 5.0 × 10−7 mol L−1. The electrode has a response time of about 40 s, and it can be used for at least 1 month without observing any considerable deviation from Nernstian response. The proposed electrode revealed an excellent selectivity toward platinum(II) ion over a wide variety of alkali, alkaline earth, transition, and heavy metal ions, and it could be used in the pH range of 3.2-5.1. The practical utility of the electrode has been demonstrated by its use in determination of platinum ion in, alloy, tap, mineral and river water samples.  相似文献   

10.
Pt nanospheres with an average diameter of 60±10 nm have been successfully synthesized at room temperature through a facile polyoxometalate(POM)-assisted process. Characterization by scanning electron microscopy (SEM) and transmission electron microscopy (TEM) clearly showed that these Pt nanospheres consisted of 2-7 nm Pt nanodots. During the formation of such unique nanostructures, POMs were found to serve as both catalyst and stabilizer. The size of the as-synthesized Pt nanospheres could be controlled solely by adjusting the molar ratio of POMs to H2PtCl6. A possible formation mechanism based on POMs-mediated electron transfer from ascorbic acid (AA) to PtCl62− and AA-assisted aggregation was tentatively proposed to rationalize the formation of such nanostructures. Importantly, these specific Pt nanospheres exhibited good electrocatalytic activity towards the oxidation of methanol, making them promising for applications in direct methanol fuel cells.  相似文献   

11.
For the isocratic ion chromatography (IC) separation of low-molecular-mass organic acids and inorganic anions three different anion-exchange columns were studied: IonPac AS14 (9 μm particle size), Allsep A-2 (7 μm particle size), and IC SI-50 4E (5 μm particle size). A complete baseline separation for all analyzed anions (i.e., F, acetate, formate, Cl, NO2, Br, NO3, HPO42− and SO42−) in one analytical cycle of shorter than 17 min was achieved on the IC SI-50 4E column, using an eluent mixture of 3.2 mM Na2CO3 and 1.0 mM NaHCO3 with a flow rate of 1.0 mL min−1. On the IonPac AS14 column, it was possible to separate acetate from inorganic anions in one run (i.e., less than 9 min), but not formate, under the following conditions: 3.5 mM Na2CO3 plus 1.0 mM NaHCO3 with a flow rate of 1.2 mL min−1. Therefore, it was necessary to adapt a second run with a 2.0 mM Na2B4O7 solution as an eluent under a flow rate of 0.8 mL min−1 for the separation of organic ions, which considerably enlarged the analysis time. For the Allsep A-2 column, using an eluent mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.6 mL min−1, it was possible to separate almost all anions in one run within 25 min, except the fluoride-acetate critical pair. A Certified Multianion Standard Solution PRIMUS for IC was used for the validation of the analytical methods. The lowest RSDs (less than 1%) and the best LODs (0.02, 0.2, 0.16, 0.11, 0.06, 0.05, 0.04, 0.14 and 0.09 mg L−1 for F, Ac, For, Cl, NO2, Br, NO3, HPO42− and SO42−, respectively) were achieved using the IC SI-50 4E column. This column was applied for the separation of concerned ions in environmental precipitation samples such as snow, hail and rainwater.  相似文献   

12.
Summary Platinum(II) and platinum(IV) complexes of 2-amino-4, 6-dimethylpyrimidine, ADMPY, have been prepared. Solids of formula Pt(ADMPYH+)Cl3, Pt(ADMPY)2Cl4 and Pt(ADMPY)2Cl4·2HCl have been isolated and characterized by elemental analyses in conjuction with i.r. and n.m.r. spectra. A paramagnetic tan to reddishbrown complex has been reproducibly prepared from the direct reaction of K2PtCl4 and ADMPY at pH 6.  相似文献   

13.
This paper describes a highly sensitive, selective catalytic-kinetic-spectrophotometric method for the determination of copper(II) concentration as low as 6 ng ml−1. The method is based on the catalytic effect of copper(II) on the oxidation of citric acid by alkaline hexacyanoferrate(III). The reaction was followed by measuring the decrease in absorbance of hexacyanoferrate(III) at 420 nm (λmax of [Fe(CN)6]3−,  = 1020 dm3 mol−1 cm−1). The dependence of rate of the indicator reaction on the reaction variables has been studied and discussed to propose a suitable mechanism to get a relation between the reaction rate and [Cu2+]. A fixed time procedure has been used to obtain a linear calibration curve between the initial rate and lower [Cu2+] or log[Cu2+] in the range 1 × 10−7 to 4 × 10−4 mol l−1 (6.35-25,400 ng ml−1). The detection limit has been calculated to be 4 ng ml−1. The maximum average error is 3.5%. The effect of the presence of various cations, commonly associated with copper(II) and some anions has also been investigated and discussed. The proposed method is sensitive, accurate, rapid and inexpensive compared to other techniques available for determination of copper(II) in such a large range of concentration. The new method has been successfully applied for the determination of copper(II) in various samples.  相似文献   

14.
Svancara I  Foret P  Vytras K 《Talanta》2004,64(4):844-852
A procedure for the determination of chromium is described based on synergistic pre-concentration of the chromate anion at a carbon paste electrode modified in situ with quarternary ammonium salts such as 1-ethoxycarbonylpentadecyltrimethylammonium bromide (Septonex®), cetyltrimethylammonium bromide (CTAB) or cetylpyridinium bromide (CPB). The proper electrochemical detection utilises the reduction Cr(VI) → Cr(III) performed in the differential pulse cathodic voltammetric mode. In discussion, considerable attention has been paid to the accumulation mechanism at the carbon paste electrode in the presence of surfactants. Furthermore, after optimising the corresponding experimental conditions (0.1-0.3 M HCl + 0.1 M NaCl as the supporting electrolyte, 2.5-25 μM as the total concentration of modifier, pre-concentration at +0.7 V versus Ag/AgCl and the stripping from +0.7 to −0.4 V), the analytical performance of the method has been evaluated. The signal of interest was reproducible within ±8% and proportional to the concentration in a range of 0.5-50 μM CrO42−, with a limit of detection (S/N = 3:1) of about 5×10−8 M CrO42− (with accumulation for 300 s). Interference studies were focused mainly on the species capable of forming ion-pairs with the modifier; i.e., TlCl4, AuCl4, PdCl42−, PtCl62−, VO43−, MnO4 and I. Practical applicability of the method was tested on model solutions via the recovery rates (typically 90-110%) or using selected certified reference materials (tea, bush leaves, clover) and two samples of black tea when the respective results were compared to those obtained by the reference determinations with ICP-AES.  相似文献   

15.
A novel method for inductively coupled plasma atomic emission spectrometry (ICP-AES) determination of trace amounts of Pt(II), Pd(II) and Rh(III), based on gaseous compounds introduction into the plasma as their diethyldithiocarbamate complexes by electrothermal vaporization (ETV), was developed. At the temperature of 1100 °C, the trace amounts of Pt, Pd and Rh were vaporized into plasma. The factors affecting the formation of the chelates and their vaporization behaviors, such as ashing temperature and time, vaporization temperature and time, pH and the concentration of chelating reagents were studied in detail. Under the optimized conditions, the limits of detection (LODs) (3σ) of Pt, Pd and Rh for tested solutions were 5.4, 1.4 and 0.8 ng ml−1, and for actual sample (auto-catalyst NIST SRM 2557) were 0.27, 0.07 and 0.04 μg g−1, respectively. The relative standard deviations (RSDs) for Pt, Pd and Rh were 1.4, 2.6 and 2.4% (CPt=0.5 μg ml−1, CPd,Rh=0.25 μg ml−1, n=7), respectively. The linear ranges of calibration graphs for Pt, Pd and Rh cover three orders of magnitude. Compared with conventional electrothermal vaporization technique, using the reagent of diethyldithiocarbamate as chemical modifier could not only enhance the analytical sensitivities, but also reduce the vaporization temperature. By combination with a separation/preconcentration step, the proposed method had been successfully applied to the analysis of the artificial seawater, tap water and urine with recoveries ranging from 91 to 106%. The two certified reference material meager platinpalladium ore GBW 07293 and auto-catalyst NIST SRM 2557 was also analyzed for validation, and the determined values obtained were in good agreement with the certified values.  相似文献   

16.
Drusković V  Vojković V  Miko S 《Talanta》2004,62(3):489-495
A new spectrofluorimetric determination of iridium(IV) with 3-hydroxy-2-methyl-1-phenyl-4-pyridone (HX) or 3-hydroxy-2-methyl-1-(4-tolyl)-4-pyridone (HY) is reported. Iridium(IV) react with HX or HY and chelates were extracted into chloroform or dichloromethane. The organic phase showed fluorescence. The fluorescence measurements to quantify iridium were carried out in its fluorescent band centred at λex=373 nm and λem=480 nm. Under optimal conditions, the calibration graphs were linear over the concentration range of 0.1-7.6 μg ml−1 of iridium for Ir(IV)-HX and 0.1-5.8 μg ml−1 for Ir(IV)-HY with a correlation coefficients of 0.999 and 0.992 and relative standard deviation of ±1.1%.The method is free from interference by Rh(III) and Pt(IV), which normally interfere with other methods. Iridium can be determined in the presence of 300-fold excess of rhodium(III) and 10-fold excess of platinum(IV).The method was applied successfully to the determination of iridium in some synthetic mixtures and mineral sample gave satisfactory results.  相似文献   

17.
Melchert WR  Rocha FR 《Talanta》2005,65(2):461-465
Nitrate determination in waters is generally carried out with cadmium filings and carcinogenic reagents or by reaction with phenolic compounds in highly concentrated sulfuric acid medium. In this work, it was developed a green analytical procedure for nitrate determination in natural waters based on direct spectrophotometric measurements in ultraviolet, using a flow-injection system with an anion-exchange column for separation of nitrate from interfering species. The proposed method employs only one reagent (HClO4) in a minimum amount (equivalent to 18 μL concentrated acid per determination), and allowed nitrate determination within 0.50-25.0 mg L−1, without interference of up to 200.0 mg L−1 humic acid; 1.0 mg L−1 NO2; 200.0 mg L−1 PO43−; 75.0 mg L−1 Cl; 50.0 mg L−1 SO42− and 15.0 mg L−1 Fe3+. The detection limit (99.7% confidence level) and the coefficient of variation (n = 20) were estimated as 0.1 mg L−1 and 0.7%, respectively. The results obtained for natural water samples were in agreement with those achieved by the reference method based on nitrate reduction with copperized cadmium at the 95% confidence level.  相似文献   

18.
Summary Five Cu(II), Pd(II), Cd(II), Pt(IV), and Au(III) complexes of 6-chloropurine have been obtained. The complexes were characterized by elemental analysis, IR,1H-NMR and13C-NMR spectroscopy. On the basis of these data the structure of the complexes and the coordination of the ligand have been proposed. Thus, the physical and chemical methods supported evidence that in acidic medium, with exception of the Cu(II) complex, 6-chloropurine acts in the monoprotonated form neutralizing the charge of [PdCl4]2–, [CdCl4]2–, [AuCl4] and [PtCl6]2– anions. The thermal behaviour of the complexes has also been studied.
Metallkomplexe von 6-Chlorpurin
Zusammenfassung Es wurden fünf Komplexe von 6-Chlorpurin mit Cu(II), Pd(II), Cd(II), Pt(IV) und Au(III) erhalten. Die Komplexe wurden mittels Elementaranalysen, IR,1H-NMR und13C-NMR charakterisiert. Auf der Basis dieser Daten wurde eine Komplexstruktur und eine bestimmte Koordination der Liganden vorgeschlagen. Physikalische und chemische Methoden beweisen, daß im sauren Bereich [mit der Ausnahme von Cu(II)] das 6-Chlorpurin in der monoprotonierten Form koordiniert, wobei die Ladung von [PdCl4]2–, [CdCl4]2–, [AuCl4] und [PtCl6]2– jeweils neutralisiert wird. Das thermische Verhalten der Komplexe wurde ebenfalls untersucht.
  相似文献   

19.
Hong-Yuan Luo  Chun-Yan Li 《Talanta》2007,72(2):575-581
The design and synthesis of a porphyrin-appended terpyridine, 5-(4-([2,2′:6′,2″]-terpyridin-4-yl-carboxyamidyl)phenyl)-10,15,20-triphenylporphyrin (H2TPPTPy) and its application as potential fluoroionophore for recognition of metal ions are reported. For preparation of the fluoroionophore, a novel simple strategy with improved total yield has been applied for the synthesis of 2,2′:6′,2″-terpyridine-4′-carboxylic acid as a ligand. H2TPPTPy shows chelation-enhanced fluorescence effect with cadmium ion via the interruption of photoinduced electron transfer (PET) process, which has been utilized as the basis of the fabrication of the Cd(II)-sensitive fluorescent chemosensor. The analytical performance characteristics of the proposed Cd(II)-sensitive chemosensor were investigated. It shows a linear response toward Cd(II) in the concentration range of 3.2 × 10−6 to 3.2 × 10−4 M with a limit of detection of 1.2 × 10−6 M. The chemosensor shows good selectivity for Cd(II) over a large number of cations, such as alkali, alkali earth and transitional metal ions except Cu(II) and Zn(II). The sensor has been used for determination of Cd(II) in water samples with satisfactory recoveries.  相似文献   

20.
Kaya M  Volkan M 《Talanta》2011,84(1):122-126
A new chloride generation system was designed for the direct, sensitive, rapid and accurate determination of the total germanium in complex matrices. It was aimed to improve the detection limit of chloride generation technique by increasing the vapor pressure of germanium tetrachloride (GeCl4). In order to do so, a novel joint vapor production and gas-liquid separation unit equipped with a home-made oven was incorporated to an ordinary nitrous oxide-acetylene flame atomic absorption spectrometer. Several variables such as reaction time, temperature and acid concentration have been investigated. The linear range for germanium determination was 0.1-10 ng mL−1 for 1 mL sampling volume with a detection limit (3 s) of 0.01 ng mL−1. The relative standard deviation (RSD) was 2.4% for nine replicates of a 1 ng mL−1 germanium solution. The method was validated by the analysis of one non-certified and two certified geochemical reference materials, respectively, CRM GSJ-JR-2 (Rhyolite), and GSJ-JR-1 (Rhyolite), and GBW 07107 (Chinese Rock). Selectivity of the method was investigated for Cd2+, Co2+, Cu2+, Fe3+, Ga3+, Hg2+, Ni2+, Pb2+, Sn2+, and Zn2+ ions and ionic species of As(III), Sb(III), Te(IV), and Se(IV).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号