首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Cyclic voltammetry was used to investigate the electrochemical behaviour of triclosan (2,2,4′-trichloro-2′-hydroxydiphenyl ether) at a screen-printed carbon electrode (SPCE). It was found that a single anodic peak occurred over the pH range 6.0–12.0; this peak was considered to result from an irreversible oxidation reaction at the phenolic moiety. A plot of Ep versus pH was constructed and from the break point a pKa value of 7.9 was obtained, thus agreeing with the literature value. Detailed voltammetric studies were performed at pH 10, where the analyte exists as an anion. It was demonstrated that, at an initial potential of 0 V, the anion underwent electrosorption prior to electrochemical oxidation. The oxidation reaction appeared to involve a one-electron transfer, as deduced from a calculated na value of 0.5; the same value was obtained at pH 7.0. In contrast to triclosan, triclosan monophosphate was found to be electrochemically inactive when subjected to voltammetry under the stated conditions.

The electrochemical oxidation of triclosan at a SPCE was exploited for its determination (0.3%) in commercial toothpaste and mouthrinse products using differential pulse voltammetry. The recovery and precision data indicated that this approach may have application in routine quality control analysis.  相似文献   


2.
The electrochemical synthesis of silver nanoparticles (nano‐Ag) has been successfully carried out on glassy carbon electrode (GCE) and indium tin oxide electrode (ITO) using 1‐butyl‐3‐methylimidazolium tetrafluoroborate (BMT) as green electrolytes. Further the electrodeposited nano‐Ag modified ITO electrode has been examined using atomic force microscopy (AFM), and X‐ray diffraction studies (XRD). The electrodeposited Ag nanoparticles on ITO were found in the size range of 5 to 35 nm. The nano‐Ag film modified GCE was further coated with nafion (Nf) and BMT (1 : 1 ratio) mixture and found to be stable in BMT and in pH 7 phosphate buffer solution (PBS). The nano‐Ag/BMT‐Nf film modified GCE successfully applied for the oxygen reduction reaction in neutral pH (pH 7.0 PBS). The proposed film modified GCE successfully reduces the over potential and show well defined reduction peaks for the detection of dissolved oxygen using cyclic voltammetry (CV) and rotating disc voltammetry (RDE). The film also applied for the detection of dissolved oxygen using electrochemical impedance spectroscopic studies (EIS).  相似文献   

3.
Carboxylated multiwalled carbon nanotubes (MWCNT-COOH) dissolved in a mixture of DMF:water were used to modify the surfaces of commercially available screen-printed electrodes (SPEs). The morphology of the MWCNT-COOH and the modified SPEs was characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM), respectively. SEM analysis showed a porous structure formed by a film of disordered nanotubes on the surface of the working electrode.The modification procedure with MWCNT-COOH was optimised and it was applied to unify the electrochemical behaviour of different gold and carbon SPEs by using p-aminophenol as the benchmark redox system. The analytical advantages of the MWCNT-COOH-modified SPEs as voltammetric and amperometric detectors as well as their catalytic properties were discussed through the analysis, for instance, of dopamine and hydrogen peroxide. Experimental results show that the electrochemical active area of the nanotube-modified electrode increased around 50%. The repeatability of the modification methodology is around 6% (R.S.D.) and the stability of MWCNT-COOH-modified SPEs is ensured for, at least, 2 months.  相似文献   

4.
In this article, a study of novel screen-printed electrodes bulk-modified with five potential bismuth precursor compounds (bismuth citrate, bismuth titanate, bismuth oxide, bismuth aluminate and bismuth zirconate) is presented for the determination of Cd(II) and Pb(II) by anodic stripping voltammetry. During the electrolytic deposition step, the precursor was reduced and served as the source of bismuth. Different key parameters were investigated in detail such as the nature of the bismuth precursor compound, the precursor content in the carbon ink, the polarisation range of the sensors, the supporting electrolyte, the stripping waveform, the deposition time, the deposition potential and the long-term stability of the sensors under continuous use. Using bismuth citrate as the precursor, the limit of detection was 0.9 μg L−1 for Pb(II) and 1.1 μg L−1 for Cd(II). The reproducibility on the same sensor (expressed as % relative standard deviation, (n = 8)) was 5.4% for Pb(II) and 7.2% for Cd(II) at the 20 μg L−1 level. Finally, the sensors were applied to the determination of Cd(II) and Pb(II) in water samples.  相似文献   

5.
The electrochemical behavior of a platinum electrode in a set of 1-alkyl ether (and 1-alkyl)-3-methylimidazolium room-temperature ionic liquids (RTILs) 1–3 ([CxOyMim]+[Anion] or [CxMim]+[Anion], where Mim = 3-methylimidazolium; CxOy = 1-alkyl ether; C7O3 = -(CH2)2O(CH2)2O(CH2)2OCH3; C3O1 = -(CH2)2OCH3; Cx = 1-alkyl; C10 = C10H21; C4 = C4H9; and ) was studied by cyclic voltammetry and electrical conductivity. This complementary set of imidazolium RTILs allowed us to explore the effect of the imidazolium cation and the counter-ion, both of which affected the electrochemical window of these RTILs. Various electrochemical events with low current values were observed, which diminished the electrochemical windows. Interestingly, RTILs 2b [1-(2-methoxyethyl)-3-methylimidazolium tetrafluoroborate] and 2d [1-butyl-3-methylimidazolium tetrafluoroborate] showed quasireversible charge transfer processes. The length of the functional group attached to the imidazolium cation was shown to be of great influence as larger electrochemical windows, as well as lower electrical conductivities, were obtained with the longer C7O3 and C10 functional groups. The largest electrochemical window of 2.0 V was achieved with RTIL 2c, 1-decyl-3-methylimidazolium tetrafluoroborate. Dedicated to the memory of Prof. Francisco Nart.  相似文献   

6.
V. Meucci  S. Laschi  C. Pretti  G. Soldani 《Talanta》2009,77(3):1143-674
An optimized digestion method coupled to electrochemical detection to monitor lead, copper, cadmium and mercury in fish tissues was developed. Square wave anodic stripping voltammetry (SWASV) coupled to disposable screen-printed electrodes (SPEs) was employed as fast and sensitive electroanalytical method for heavy metals detection. Different approaches in digestion protocols were assessed. The study was focused on Atlantic hake fillets because of their wide diffusion in the human nutrition. Best results were obtained by digesting fish tissue with hydrogen peroxide/hydrochloric acid mixture coupled to solid phase (SP) purification of the digested material. This combined treatment allowed quantitative extraction from fish tissue (muscle) of the target analytes, with fast execution times, high sensitivity and avoiding organic residues eventually affecting electrochemical measurements. Finally, the method has been validated with reference standard materials such as dogfish muscle (DORM-2) and mussel tissues (NIST 2977).  相似文献   

7.
An approximate mathematical model for electrochemical dissolution/growth processes of diffusionally independent and well-separated particles randomly dispersed on an inert conducting electrode surface is presented and solved using numerical simulation. The model, mimicking abrasively modified electrodes where particles of electroactive voltammograms solid are immobilised on an electrode surface, provides clear insights into the effects of different parameters on the voltammetric response of such systems and permits the exploration of the competition taking place between mass transport and surface processes. The mathematical model is then compared with experimental data obtained with basal plane pyrolytic graphite electrode abrasively modified with solid particles of perinaphthenone and studied in aqueous solution.Dedicated to Professor Dr. Alan M. Bond on the occasion of his 60th birthday.  相似文献   

8.
An ionic liquid (IL) modified carbon ceramic electrode (CCE) was designed and further used for the voltammetric detection of rutin in this paper. IL-CCE was prepared by mixing graphite powder with 1-butyl-3-methylimidazolium tetrafluoroborate (EMIMBF4) doped silicate sol-gel matrix together and further characterized by different methods. Then electrochemical behaviors of rutin on the IL-CCE were investigated by different electrochemical methods such as cyclic voltammetry and differential pulse voltammetry (DPV). Due to the presence of IL in the CCE, an enhanced electrochemical response of rutin appeared with a pair of well-defined redox peaks in pH 2.5 phosphate buffer solution (PBS). The electrochemical behaviors of rutin on the IL-CCE were carefully investigated. Under the selected conditions the oxidation peak currents exhibited good linear relationship with the rutin concentration in the range from 0.3 to 100.0 μmol/L with the detection limit as 0.09 μmol/L (3σ). The proposed method was further applied to the rutin tablets sample detection with satisfactory results.  相似文献   

9.
The oxidative behaviour of pimozide was studied in hydroalcoholic media (10+90 methanol-H2O, pH range 2-7.5) at carbon based electrodes. Pimozide was irreversibly oxidized at high positive potentials, resulting in the formation of a couple with a reduction and re-oxidation peak at much lower potentials. The response was evaluated with respect to pH, scan rate, addition of surfactant and other variables. Using differential pulse voltammetry (DPV), the drug yielded a well-defined voltammetric response in Britton-Robinson buffer, pH 2.1 at +1.1 V (versus Ag/AgCl) on glassy carbon electrode. The process could be used to determine pimozide concentrations in the range 8×10−7-1×10−4 M. Applicability to tablets and human serum analysis was illustrated. Furthermore, a high-performance liquid chromatographic method with electrochemical detection (HPLC-EC) was developed, which allowed pimozide to be detected down to a level of 2.7×10−10 M (0.25 ppb).  相似文献   

10.
Competitive electrochemical enzyme-linked immunosorbent assays based on disposable screen-printed electrodes have been developed for quantitative determination of ochratoxin A (OTA). The assays were carried out using monoclonal antibodies in the direct and indirect format. OTA working range, I50 and detection limits were 0.05-2.5 and 0.1-7.5 μg L−1, 0.35 (±0.04) μg L−1 and 0.9 (±0.1) μg L−1, 60 and 100 μg L−1 in the direct and indirect assay format, respectively. The immunosensor in the direct format was selected for the determination of OTA in wheat. Samples were extracted with aqueous acetonitrile and the extract analyzed directly by the assay without clean-up. The I50 in real samples was 0.2 μg L−1 corresponding to 1.6 μg/kg in the wheat sample with a detection limit of 0.4 μg/kg (calculated as blank signal −3σ). Within- and between-assay variability were less than 5 and 10%, respectively. A good correlation (r = 0.9992) was found by comparative analysis of naturally contaminated wheat samples using this assay and an HPLC/immunoaffinity clean-up method based on the AOAC Official Method 2000.03 for the determination of OTA in barley.  相似文献   

11.
Modified graphite electrodes were prepared with materials containing carbonyl functional groups, including polypyrrole containing poly(methyl vinyl ketone). The effect of the modification on the electrochemical response of 2,6-diaminopurin-8-ol, a small, electrochemically fast biological molecule with primary amine groups which absorbs on active graphite, was evaluated. The results show that the chemical interactions between 2,6-diaminopurin-8-ol and the surface carbonyl functional groups do not by themselves contribute to the reactivity of the probe molecule.  相似文献   

12.
二茂铁在几种离子液体中的迁移行为   总被引:2,自引:1,他引:2  
采用循环伏安法研究了二茂铁(Fc)在几种离子液体中的迁移行为. 计算了Fc在各离子液体中的扩散系数和粘度系数,探讨了离子液体粘度与离子液体结构之间的关系. 实验结果表明, 离子液体的粘度随阳离子取代基碳链长度的增加而增加, 随阴离子对称性的增加而增加.  相似文献   

13.
This paper describes the voltammetric determination of cocaine in presence of three different interferences that could be found in street samples using disposable sensors. The electrochemical analysis of this alkaloid can be affected by the presence of codeine, paracetamol or caffeine, whose oxidation peaks may overlap and lead to false positives. This work describes two different solutions to this problem. On one hand, the modification of disposable carbon sensors with carbon nanotubes allows the voltammetric quantification of cocaine by using ordinary least squares regressions in the concentration range from 10 to 155 μmol L−1, with a reproducibility of 5.6% (RSD, n = 7. On the other hand, partial least squares regressions are used for the resolution of the overlapped voltammetric signals when using screen-printed carbon electrodes without any modification. Both procedures have been successfully applied to the evaluation of the purity of cocaine street samples.  相似文献   

14.
The use of 3-indoxyl phosphate (3-IP) as an electrochemical substrate for ELISAs with voltammetric detection was investigated. Indirect measurements of alkaline phosphatase (AP) and horseradish peroxidase (HRP) activity in solution were carried out. Picomolar levels of both enzymes can be detected, which enables the design of electrochemical immunoassays using this substrate. The enzymatic turnover of the substrate gives indigo blue, insoluble in aqueous solutions. This product is easily converted into its soluble parent compound, indigo carmine (IC), by addition of fuming sulphuric acid to the reaction media. IC shows a reversible voltammetric peak at the formal potential of −0.15 V (versus Ag pseudo-reference electrode) when a screen-printed carbon electrode (SPCE) is used. The peak current of this process constitutes the analytical signal. Using this approach an ELISA assay to quantify pneumolysin (PLY, a toxin related to respiratory infections) was carried out using AP or HRP as enzymatic label. Calibration plots obtained are reported. 3-IP is demonstrated to be the first suitable substrate for the two most common enzyme labels used in immunoassays.  相似文献   

15.
A simple procedure for the chemical synthesis of bismuth nanoparticles and subsequent adsorption on commercial screen-printed carbon electrodes offer reliable quantitation of trace zinc, cadmium and lead by anodic stripping square-wave voltammetry in nondeareated water samples. The influence of two hydrodynamic configurations (convective cell and flow cell) and the effect of various experimental variables upon the stripping signals at the bismuth-coated sensor are explored. The square-wave peak current signal is linear over the low ng mL−1 range (120 s deposition), with detections limits ranging from 0.9 to 4.9 ng mL−1 and good precision. Applicability to waste water certified reference material and drinking water samples is demonstrated. The attractive behaviour of the new disposable Bi nanoparticles modified carbon strip electrodes, coupled with the negligible toxicity of bismuth, hold great promise for decentralized heavy metal testing in environmental and industrial effluents waters.  相似文献   

16.
A glassy carbon electrode was modified with carbon nanotubes and the ionic liquid N‐butyl pyridinium trifluoromethyl methanesulfonate for the determination of methyldopa in urine samples. Methyldopa exhibited a well‐defined anodic signal over a broad pH range of 2–10 and the peak current increased approximately 100 fold over that of the unmodified electrode. Accordingly, a novel method for the determination of methyldopa was proposed using differential pulse voltammetry. The peak current was linear over a methyldopa concentration range from 21 to 2111 ng mL?1 with a LOD of 6.9 ng mL?1 and a LOQ of 7.4 ng mL?1. The method was applied to determine the excretion profile of methyldopa in urine without sample pretreatment.  相似文献   

17.
Zeng H  Wang Y  Kong J  Nie C  Yuan Y 《Talanta》2010,83(2):582-590
An ionic liquid-based microwave-assisted extraction (ILMAE) method has been developed for the effective extraction of rutin from Chinese medicinal plants including Saururus chinensis (Lour.) Bail. (S. chinensis) and Flos Sophorae. A series of 1-butyl-3-methylimidazolium ionic liquids with different anions were investigated. The results indicated that the characteristics of anions have remarkable effects on the extraction efficiency of rutin and among the investigated ionic liquids, 1-butyl-3-methylimidazolium bromide ([bmim]Br) aqueous solution was the best. In addition, the ILMAE procedures for the two kinds of medicinal herbs were also optimized by means of a series of single factor experiments and an L9 (34) orthogonal design. Compared with the optimal ionic liquid-based heating extraction (ILHE), marinated extraction (ILME), ultrasonic-assisted extraction (ILUAE), the optimized approach of ILMAE gained higher extraction efficiency which is 4.879 mg/g in S. chinensis with RSD 1.33% and 171.82 mg/g in Flos Sophorae with RSD 1.47% within the shortest extraction time. Reversed phase high performance liquid chromatography (RP-HPLC) with ultraviolet detection was employed for the analysis of rutin in Chinese medicinal plants. Under the optimum conditions, the average recoveries of rutin from S. chinensis and Flos Sophorae were 101.23% and 99.62% with RSD lower than 3%, respectively. The developed approach is linear at concentrations from 42 to 252 mg L−1 of rutin solution, with the regression coefficient (r) at 0.99917. Moreover, the extraction mechanism of ILMAE and the microstructures and chemical structures of the two researched samples before and after extraction were also investigated. With the help of LC-MS, it was future demonstrated that the two researched herbs do contain active ingredient of rutin and ionic liquids would not influence the structure of rutin.  相似文献   

18.
Wang J  Lu F  Macdonald D  Lu J  Ozsoz ME  Rogers KR 《Talanta》1998,46(6):1405-1412
Screen-printed carbon electrodes have been developed as disposable voltammetric sensors for 2,4,6-trinitrotoluene (TNT). Thick-film electrodes based on various conventional and modified inks have been compared for this task. The operation is based on placing the selected thick-film carbon sensor in the non-deaerated/quiescent sample and using a fast (<1 s) and sensitive square-wave voltammetric scan. Different experimental variables have been optimized to yield a detection limit of 200 ppb TNT and a wide linear range. The high selectivity, demonstrated in assays of various untreated environmental samples, is attributed to the facts that the reducible nitro group is rare in nature and that most electroactive organic compounds require higher potentials. The new single-use sensor strips should facilitate the on-site environmental screening of TNT.  相似文献   

19.
Kokkinos C  Economou A 《Talanta》2011,84(3):696-701
This work is a study of the analytical utility of Nafion-modified microfabricated bismuth film electrodes (BiFEs) for the determination of Pb(II) and Cd(II) by anodic stripping voltammetry (ASV) in the presence of surfactants. Micro-fabricated BiFEs were prepared by depositing a thin film of bismuth on the surface of a silicon substrate by sputtering while the two-dimensional geometry of the final sensors was defined by photolithography. The BiFEs were further drop-coated with a Nafion film. These devices were applied to the determination of Pb(II) and Cd(II) by square wave ASV (SWASV) in the presence of Triton X-100 (a non-ionic surfactant), cetyltrimethylammonium bromide (CTAB) (a cationic surfactant) and sodium dodecyl sulphate (SDS) (an anionic surfactant). It was found that the presence of Nafion afforded an increase in sensitivity and the tolerance against surfactants but these properties were severely influenced by both the thickness of the Nafion film and the nature of the interfering surfactant. Using a Nafion of 0.4 μm thickness and 120 s of preconcentration, the repeatability (expressed as the % relative standard deviation on the same sensor (n = 8)) at the 20 μg l−1 level was 3.8% for Pb(II) and 3.1% for Cd(II) and the limits of detection were 0.5 μg l−1 for Cd(II) and Pb(II). The sensors were applied to Cd(II) and Pb(II) determination in a certified lake-water sample.  相似文献   

20.
Ionic liquid-based dispersive liquid-liquid microextraction was developed for the extraction and preconcentration of aromatic amine from environmental water. A suitable mixture of extraction solvent (100 μL, 1-butyl-3-methylimidazolium hexafluorophoshate) and dispersive solvent (750 μL, methanol) were injected into the aqueous samples (10.00 mL), forming a cloudy solution. After centrifuging, enriched analytes in the sediment phase were determined by HPLC-UV. The effect of various factors, such as the extraction and dispersive solvent, sample pH, extraction time and salt effect were investigated. Under optimum conditions, enrichment factors for 2-anilinoethanol, o-chloroaniline and 4-bromo-N,N-dimethylaniline were above 50 and the limits of detection (LODs) were 0.023, 0.015 and 0.026 ng/mL, respectively. Their linear ranges were 0.8-400 ng/mL for 2-anilinoethanol, 0.5-200 ng/mL for o-chloroaniline and 0.4-200 ng/mL for 4-bromo-N,N-dimethylaniline, respectively. Relative standard deviations (RSDs) were below 5.0%. The relative recoveries from samples of environmental water were in the range of 82.0-94.0%. Compared with other methods, dispersive liquid-liquid microextraction is simple, rapid, sensitive and economical.  相似文献   