首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Silica-based, tentacular weak cation-exchanger particles were prepared for use as the stationary phase in the separation of positively charged sample components by capillary electrochromatography (CEC). Silica beads were first silanized with 3-(trimethoxysilyl) propyl methacrylate that served as a heterobifunctional linker, which reacted with 2-acrylarmidoglycolic acid in a second step by radical polymerization in aqueous solution. Baseline separation of basic peptides with good column efficiency was obtained on packed capillary columns by isocratic elution CEC with NaCl as the mobile phase modulator. The retention mechanism in the electrochromatographic process was studied by examining the effect of salt concentration on the migration behavior of the peptides. The chromatographic retention factor k'(lc) for charged sample components in the electrochromatographic process was estimated on the assumption that the overall migration rate of a charged migrant can be taken as the sum of the rate of chromatographic elution and the rate of electrophoretic migration. The estimated k(lc) values from experimental results were plotted against the molal salt concentration on a double logarithmic scale. The linear correlation is in good agreement with the prediction by the theory on the basis of traditional ion-exchange chromatography. The comparison of CEC results, obtained with open tubular and packed capillary columns having the same retentive functions as the stationary phase, supports the notion that variation of the phase ratio in the column offers an additional means to modulate the electrochromatographic migration behavior.  相似文献   

2.
Chromatographic retention factor, k', as defined in high-performance liquid chromatography (HPLC) in terms of the migration times of the separand and the inert tracer, has limited applicability to capillary electrochromatography (CEC) when both chromatographic and electrophoretic processes determine the magnitude of the overall migration rates of the separands. This situation is unlike that in HPLC, where k' serves as a useful peak locator for the various sample components, as well as, provides thermodynamic insights into the interactions between the components and the stationary phase. Most publications have borrowed the definition of k' from HPLC and applied it on CEC. However, due to the dual separation mechanisms that are in action in CEC, the system is significantly complicated in comparison to that of HPLC. This paper discusses the impossibility of defining with a k' which would have all the attributes that it has in regular chromatography. The interplay of the two separation mechanisms in determining the overall migration process in CEC is discussed and the various definitions of the electrochromatographic retention factor are presented.  相似文献   

3.
The potential of methacrylate-based mixed-mode monolithic stationary phases bearing sulfonic acid groups for the separation of positively charged analytes (alkylanilines, amino acids, and peptides) by capillary electrochromatography (CEC) is investigated. The retention mechanism of protonated alkylanilines as positively charged model solutes on these negatively charged mixed-mode stationary phases is investigated by studying the influence of mobile phase and stationary phase parameters on the corrected retention factor which was calculated by taking the electrophoretic mobility of the solutes into consideration. It is shown that both solvophobic and ion-exchange interactions contribute to the retention of these analytes. The dependence of the corrected retention factor on (1) the concentration of the counter ion ammonium and (2) the number of methylene groups in the alkyl chain of the model analytes investigated shows clearly that a one-site model (solvophobic and ion-exchange interactions take place simultaneously at a single type of site) has to be taken to describe the retention behaviour observed. Comparison of the CEC separation of these charged analytes with electrophoretic mobilities determined by open-tubular capillary electrophoresis shows that mainly chromatographic interactions (solvophobic and ion-exchange interactions) are responsible for the selectivity observed in CEC, while the electrophoretic migration of these analytes plays only a minor role.  相似文献   

4.
For the separation of proteins and peptides by capillary electrochromatography (CEC), columns with a monolithic stationary phase were prepared from silanized fused-silica capillaries of 50 microm I.D. by in situ copolymerization of glycidyl methacrylate, methyl methacrylate and ethylene glycol dimethacrylate in the presence of propanol and formamide as porogens. The epoxide groups at the surface of the porous monolith were reacted with N-ethylbutylamine to form fixed tertiary amino functions with ethyl- and butyl-chains. A mixture of ribonuclease A, insulin, alpha-lactalbumin and myoglobin was separated isocratically by counterdirectional CEC with hydro-organic mobile phases containing acetonitrile and sodium phosphate buffer, pH 2.5. The separation of four angiotensin type peptides by CEC was also achieved under similar conditions. The elution order of proteins was similar to that obtained in reversed-phase chromatography. Plots of the migration factors for proteins and peptides against the acetonitrile concentration exhibit opposite trends. This is most likely due to the greater chromatographic retention and lower electrophoretic migration velocity of proteins than that of peptides in the counterdirectional CEC system. From this it is concluded that the separation is governed by a dual mechanism that involves the complex interplay between selective chromatographic retention and differential electrophoretic migration.  相似文献   

5.
Li Y  Xiang R  Horváth C  Wilkins JA 《Electrophoresis》2004,25(4-5):545-553
A new kind of monolithic capillary column was prepared for capillary electrochromatography (CEC) with a positively charged polymer layer on the inner wall of a fused-silica capillary and a neutral monolithic packing as the bulk stationary phase. The fused-silica capillary was first silanized with 3-glycidoxypropyltrimethoxysilane (GPTMS). Polyethyleneimine (PEI) was then covalently bonded to the GPTMS coating to form an annular positively charged polymer layer for the generation of electroosmotic flow (EOF). A neutral bulk monolithic stationary phase was then prepared by in situ copolymerization of vinylbenzyl chloride (VBC) and ethylene glycol dimethacrylate in the presence of 1-propanol and formamide as porogens. Benzyl chloride functionalities on the monolith were subsequently hydrolyzed to benzyl alcohol groups. Effects of pH on the EOF mobility of the column were measured to monitor the completion of reactions. Using a column with this design, we expected general problems in CEC such as irreversible adsorption and electrostatic interaction between stationary phase and analytes to be reduced. A peptide mixture was successfully separated in counter-directional mode CEC. Comparison of peptide separations in isocratic monolithic CEC, gradient HPLC and capillary zone electrophoresis (CZE) indicated that the separation in CEC is governed by a dual mechanism that involves a complex interplay between selective chromatographic retention and differential electrophoretic migration.  相似文献   

6.
A monolithic silica stationary phase functionalized with an enantioselective strong cation exchanger based on an aminosulfonic acid derivative was used for chiral separations of basic test solutes by nonaqueous CEC and capillary LC. The effects of the applied electric field as well as the ionic strength in the eluent on electrokinetic and chromatographic contributions to the overall separation performance in the electrically driven mode were investigated. Hence, under the utilized experimental conditions, i. e., at an electric field strength in the range of approximately 120-720 V/cm (applied voltages 4-24 kV) and an ionic strength of the counterion between 5 and 25 mM (at constant acid-to-base, i. e., co- to counterion ratio of 2:1), no deviations from the expected linearity of the EOF were observed. This led to the conclusion that an occurrence of the so-called electrokinetic effects of the second kind resulting from electric double layer overlap inside the mesopores of the monolithic stationary phase and concentration polarization phenomena were largely negligible. Additional support to this conclusion was inferred from the observed independence of CEC retention factors on the electric field strength across the investigated ionic strength range of the BGE. As a consequence, a simple framework allowing for calculation of the CEC mobilities from the individual separation contributions, viz. electroosmotic and electrophoretic mobilities as well as retention factors, could be applied to model CEC migration. There was a reasonable agreement between calculated and experimental CEC mobility data with deviations typically below 5%. The deconvolution of the individual contributions to CEC migration and separation is of particular value for the understanding of the separation processes in which electrophoretic migration of ionic sample constituents plays a significant role like in ion-exchange CEC and may aid the optimization procedure of the BGE and other experimental conditions such as the optimization of the surface chemistry of the stationary phase. In combination with the remarkable column performance evident from the low theoretical plate heights observed under CEC conditions for all test solutes (3.5-7.5 microm in the flow rate range of 0.4-1.2 mm/s, corresponding to (130,000-300,000 plates per meter), the presented framework provides an attractive tool as the basis for the assessment of chromatographic selectivities in a miniaturized CEC screening of new selectors and chiral stationary phases (CSPs), respectively, from experimental CEC data and known CE mobilities.  相似文献   

7.
Chen JL  Hsieh KH 《Electrophoresis》2010,31(23-24):3937-3948
A new nanoparticle-bound polymer stationary phase was prepared by in situ polymerization of methacrylamide (MAA), bis-acrylamide crosslinker, and carboxylated multi-walled carbon nanotubes (multi-walled CNTs; MWNTs), using the abundant double bonds in the cyclopentadienyl rings in MWNT structure, on a silanized capillary. Each intermediate capillary between the synthesis steps was characterized by SEM, by ATR-IR, and by EOF measurements varying the pH, concentration, and volumetric ratios of ACN in running buffers. The resulting EOF profile was comparable to those of two other capillaries with different phase matrices, silica hydride and polybutyl methacrylate (BMA) phases. With the complex functionality of MWNTs on the hydrophilic polyacrylamide network, the MAA-CNT capillary was capable of separating diverse samples with a wide range of polarity and dissociation properties using open-tubular CEC. Besides optimizing CEC conditions, the migration times of samples were analyzed with respect to velocity and retention factors to evaluate electrophoretic and chromatographic contributions to the CEC mechanism. The migration rates of benzoic acids were determined by the electrophoretic mobilities of the various phenolate ions, while phenolic aldehydes and ketones were additionally influenced by chromatographic interactions, such as π-π, electrostatic effects, hydrogen bonding, and hydrophobic interactions. The retention factors were greater for flavonoids, which are polyphenolic, than for simple phenols, but were smaller than those obtained from the hydrophobic BMA-CNT column. A complete well-resolved separation of the cationic forms of tetracyclines was acheived either by electrophoresis or by chromatography in the MAA-CNT capillary, but not in the BMA-CNT and silica hydride-CNT capillaries.  相似文献   

8.
A phenomenological approach was presented to describe the retention behaviors of solutes in capillary electrochromatography (CEC). Equations for calculation of the retention time and actual chromatographic retention factor for ionic solutes, weak monoprotic acid and weak monoprotic base were derived, which can be described by two general expressions regardless the charge status of the solute. The general expressions enable calculation of the retention time and retention factor in CEC from chromatographic and electrophoretic data, which were experimentally verified with a variety of compounds and a variety of CEC modes. Based on this approach, the chromatographic retention and the electrophoretic migration in the CEC systems studied were found to be two independent processes. The validity of this approach was also discussed.  相似文献   

9.
The recognition mechanism of molecularly imprinted polymer (MIP) in capillary electrochromatography (CEC) is complicated since it possesses a hybrid process, which comprises the features of chromatographic retention, electrophoretic migration and molecular imprinting. For an understanding of the molecular recognition of MIP in CEC, a monolithic MIP in a capillary with 1,1'-binaphthyl-2,2'-diamine (BNA) imprinting was prepared by in situ copolymerization of imprinted molecule, methacrylic acid and ethylene glycol dimethacrylate in porogenic solvent, a mixture of toluene-isooctane. Strong recognition ability and high column performance (theory plates was 43,000 plates/m) of BNA were achieved on this monolithic MIP in CEC mode. In addition, BNA and its structural analogue, 1,1'-bi-2, 2'-naphthol, differing in functional groups, were used as model compounds to study imprinting effect on the resultant BNA-imprinted monolithic column, a reference column without imprinting of BNA and a open capillary. The effects of organic modifier concentration, pH value of buffer, salt concentration of buffer and column temperature on the retention and recognition of two compounds were investigated. The results showed that the molecular recognition on MIP monolith in CEC mode mainly derived from imprinting cavities on BNA-imprinted polymer other than chromatographic retention and electrophoretic migration.  相似文献   

10.
梯度加压毛细管电色谱分离蛋白质   总被引:2,自引:0,他引:2  
 以1.5 μm无孔硅胶颗粒(non-porous silica,NPS)为固定相,采用电压和压力联合驱动流动相,用反相梯度加压毛细管电色谱(p-CEC)在7.5 min内实现了核糖核酸酶A、细胞色素C、溶菌酶和肌红蛋白等4种蛋白质的快速、高效的分离。比较了梯度加压毛细管电色谱和微柱液相色谱(μ-HPLC)分离蛋白质的结果,同时考察了固定相、离子对试剂三氟醋酸(TFA)浓度和电压等条件对梯度加压毛细管电色谱分离蛋白质的影响。结果表明,梯度p-CEC可以通过调节电压精细调节带电溶质的保留,提高分离选择性,缩短分离时间,得到较高的柱效。该方法在蛋白质分离分析及蛋白质组学的研究中具有很大的应用潜力,为高效快速地分离蛋白质开辟了新的途径。  相似文献   

11.
Packed column capillary electrochromatography (CEC), open-tubular CEC and microcolum liquid chromatography (LC) using a cholesteryl silica bonded phase have been studied to compare the retention behavior for benzodiazepines. It has been found that packed column CEC gives better resolution, faster analysis time than microcolumn LC for benzodiazepines maintaining similar selectivity except for some solutes which are charged species under the separation conditions. However, open-tubular CEC gave different selectivities to a larger extent for charged benzodiazepines from that which should be produced by the chromatographic properties of the cholesteryl silica phase. Charged species migration times are mainly influenced by electrophoretic mobility rather than the chromatographic interactions.  相似文献   

12.
This work describes the separation of acidic, basic and neutral organic compounds as well as inorganic anions in a single run by capillary electrochromatography employing a stationary phase which exhibits both strong anion-exchange and reversed-phase chromatographic characteristics. The positive surface charge of this stationary phase provided a substantial anodic electroosmotic flow. The analytes were separated by a mixed-mode mechanism which comprised chromatographic interactions (hydrophobic interactions, ion-exchange) as well as electrophoretic migration. The influence of ion-exchange and hydrophobic interactions on the retention/migration of the analytes could be manipulated by varying the concentration of a competing ion and/or the amount of organic modifier present in the background electrolyte. Additionally the effects of pH changes on both the chromatographic interactions as well as the electrophoretic migration of the analytes were investigated.  相似文献   

13.
Retention behaviour of biological peptides was investigated on a stationary phase bearing an embedded quaternary ammonium group in a C21 alkyl chain by both high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC). In HPLC experiments, variation of acetonitrile (ACN) content in the mobile phase showed that peptides are mainly separated by RP mechanism. The weak or negative retention factors observed as compared to C18 silica stationary phase suggested the involvement of an electrostatic repulsion phenomenon in acidic conditions. Comparison of HPLC and CEC studies indicated that (i) ion-exclusion phenomenon is more pronounced in HPLC and (ii) higher ACN percentage in mobile phase induce for some peptides an increase of retention in CEC, pointing out the existence of mechanisms of retention other than partitioning mainly involved in chromatographic process. This comparative study demonstrated the critical role of electric field on peptide retention in CEC and supports the solvatation model of hydrolytic pillow proposed by Szumski and Buszewski for CEC using mixed mode stationary phase in CEC.  相似文献   

14.
The potential of 3-(4-sulfo-1,8-naphthalimido)propyl-modified silyl silica gel (SNAIP) as a mixed-mode stationary phase for capillary electrochromatography (CEC) was investigated for the separation of charged analytes, taking four amino acids (tyrosine, phenylalanine, tryptophan, histidine) as model analytes. The elution process of these charged analytes in CEC with SNAIP was dominated by a combination of both electrophoretic process and chromatographic process involving hydrophobic as well as electrostatic interactions. In order to study the retention mechanism, the CEC retention factor k* and the velocity factor ke* were measured for the amino acids, which allowed the assessment of the respective contribution from the differential processes underlying the separation. Migration and retention could be mediated by changing various mobile phase compositions, including buffer pH, buffer concentration, and concentration of organic solvent. Based on the results obtained by separation of the amino acids, the separation of eight peptides (Gly-Val, Gly-Phe, Gly-Ile, Gly-His, Gly-Lys, Lys-Lys, Gly-Gly-Gly, Gly-Gly-His) was attempted. A good separation was achieved under an isocratic elution with a mobile phase consisting of 35 mM phosphate buffer (pH 3.8) and 40% methanol.  相似文献   

15.
In this study, the thrombin receptor antagonistic peptide TRAP-1 and its alanine-scan analogues, TRAP 2-6, have been employed as probes to characterise the performance of C18/SCX mixed-mode capillary electrochromatographic (CEC) columns. It was found that the resolution of this group of peptides could only be achieved in a narrow pH range with phosphate-based running electrolytes. The influence of the running electrolyte composition, e.g. the buffer choice, the ionic strength, the pH and the organic solvent content, on the electroosmotic flow (EOF) of these mixed-mode CEC columns was investigated. In addition, the retention mechanism for this group of peptide probes in the electrochromatographic process was studied by examining the effect of varying the running electrolyte composition. As a result, it can be concluded that the electrochromatographic separation of this set of peptides was mediated by a combination of electrophoretic migration and chromatographic retention involving both hydrophobic as well as ion exchange interactions. By modulating the running electrolyte composition, the hydrophobic or ion exchange components of the interaction process could be made to dominate the chromatographic retention of the peptides. Based on this strategy, a high-resolution separation of six closely related synthetic peptides was demonstrated with this mixed-mode CEC system.  相似文献   

16.
Capillary columns with monolithic stationary phase were prepared from silanized fused-silica capillaries of 75 microns I.D. by in situ copolymerization of divinylbenzene either with styrene or vinylbenzyl chloride in the presence of a suitable porogen. The porous monolithic support in this study was used either directly or upon functionalization of the surface to obtain a stationary phase that was appropriate for the separation of peptides by capillary electrochromatography (CEC). The main advantages of monolithic columns are as follows. They do not need retaining frits, they do not have charged particles that can get dislodged in high electric field, and they have relatively high permeability and stability. Whereas such columns are designed especially for CEC, they find application in micro high-performance liquid chromatography (mu-HPLC) as well. Five different porogens were employed to prepare the monolithic columns that were examined for permeability and porosity. The flexibility of fused-silica capillaries was not adversely affected by the monolithic packing and the longevity of the columns was satisfactory. This may also be due to the polymerization technique, which resulted in a fluid-impervious outer layer of the monolith that precluded contact between the fused-silica surface and the liquid mobile phase. For the most promising columns, the conductivity ratios and the parameters of the simplified van Deemter equation, both in mu-HPLC and CEC, were evaluated. It was found that the efficiency of the monolithic columns in CEC was significantly higher than in mu-HPLC in the same way as observed with capillary columns having conventional particulate packing. This is attributed to the relaxation of band-broadening with electroosmotic flow (EOF) with respect to that with viscous flow. It follows then that the requirement of high packing uniformity to obtain high efficiency may also be relaxed in CEC. Angiotensin-type peptides were separated by CEC with columns packed with a monolithic stationary phase having fixed n-octyl chains and quaternary ammonium groups at the surface. Plate heights of about 8 microns were routinely obtained. The mechanism of the separation is based on the interplay between EOF, chromatographic retention and electrophoretic migration of the positively charged peptides. The results of the complex migration process, with highly nonlinear dependence of the migration times on the organic modifier and the salt concentration, cannot be interpreted within the framework of classical chromatography or electrophoresis.  相似文献   

17.
A humic acid stationary phase is evaluated for studying by capillary electrochromatography (CEC) the binding of four pesticides with humic acid (HA), the main organic component in soil. It was demonstrated that the humic acid capillary was stable in terms of efficiency and retention during a long period of time. It appeared that HA has a lower affinity for neutral than for charged pesticides. The influence of the mobile phase constitution on the pesticide retention was also investigated in order to provide valuable information about the binding mechanism. The results suggest that the interactions of the pesticides during CEC are solely based on chromatographic mechanisms and that electrophoresis only plays a minor role. As well, it was shown that the HA stationary phase was able to separate these pesticides by CEC with a low analysis time. This HA capillary column could soon become attractive to determining the risk assessment of pesticides.  相似文献   

18.
This review summarizes applications of CEC for the analysis of proteins and peptides. This "hybrid" technique is useful for the analysis of a broad spectrum of proteins and peptides and is a complementary approach to liquid chromatographic and capillary electrophoretic analysis. All modes of CEC are described--granular packed columns, monolithic stationary phases as well as open-tubular CEC. Attention is also paid to pressurized CEC and the chip-based platform.  相似文献   

19.
Bedair M  El Rassi Z 《Electrophoresis》2002,23(17):2938-2948
A novel monolithic stationary phase having long alkyl chain ligands (C17) was introduced and evaluated in capillary electrochromatography (CEC) of small neutral and charged species. The monolithic stationary phase was prepared by the in situ copolymerization of pentaerythritol diacrylate monostearate (PEDAS) and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) in a ternary porogenic solvent consisting of cyclohexanol/ethylene-glycol/water. While AMPS was meant to support the electroosmotic flow (EOF) necessary for transporting the mobile phase through the monolithic capillary, the PEDAS was introduced to provide the nonpolar sites for chromatographic retention. Monolithic columns at various EOF velocities were readily prepared by conveniently adjusting the amount of AMPS in the polymerization solution as well as the composition of the porogenic solvent. The monolithic stationary phases thus obtained exhibited reversed-phase chromatography behavior toward neutral solutes and yielded a relatively strong EOF. For charged solutes (e.g., dansyl amino acids), nonpolar as well as electrostatic interaction/repulsion with the monoliths were observed in addition to electrophoretic migration. Therefore, for charged solutes, selectivity and migration can be readily manipulated by changing various parameters including the nature of the monolith and the composition of the mobile phase (e.g., pH, ionic strength and organic modifier). Ultrafast separation on the time scale of seconds of 17 different charged and neutral pesticides and metabolites were performed using short capillary columns of 8.5 cm x 100 microm ID.  相似文献   

20.
A novel packing material, 3-(4-sulfo-1,8-naphthalimido)propyl-modified silyl silica gel (SNAIP), was prepared for the use as a stationary phase of capillary electrochromatography (CEC). The sulfonic acid groups on SNAIP stationary phase contributed to the generation of electroosmotic flow (EOF) at low pH and served as a strong cation-exchanger. In CEC with SNAIP, a mixed-mode separation was predicted, comprising hydrophobic and electrostatic interactions as well as electrophoretic migration process. In order to understand the retention mechanism on SNAIP, effects of buffer pH, concentration, and mobile phase composition on EOF mobility and the retention factors of barbiturates and benzodiazepines were systematically investigated. Moreover, the retention behavior of barbiturates on SNAIP was investigated and compared with those on octadecyl silica (ODS), phenyl-bonded silica, and 3-(1,8-naphthalimido)propyl-modified silyl silica gel to confirm the presence of pi-pi interaction on its retention mechanism. It was observed that a column efficiency was more than 85,000 N/m for retained compounds and the relative standard deviations for the retention times of EOF marker, thiourea, and five barbiturates were below 2.5% (n = 4). Under an applied voltage of 20 kV and a mobile phase consisted of 5 mM phosphate (pH 3.8) and 40% methanol, the baseline separation of five barbiturates was achieved within 3 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号