共查询到20条相似文献,搜索用时 0 毫秒
1.
An efficient method for the simultaneous determination of methyl tert.-butyl ether, tert.-butyl alcohol, benzene, toluene, ethylbenzene and xylene isomers in groundwater by purge-and-trap-gas chromatography-mass spectrometry was developed and validated. Experimental design was used to investigate the effects of temperature of extraction, time of extraction and percentage of salt added to the water samples. Regression models and desirability functions were applied to find the experimental conditions providing the highest global extraction yield. Validation was carried out in terms of limits of detection (LOD), limits of quantitation (LOQ), linearity and precision. LOD values ranging from 2.6 to 23 ng l(-1) were achieved, whereas linearity was statistically verified over two orders of magnitude for each compound. Precision was evaluated testing two concentration levels. Good results were obtained both in terms of intra-day repeatability and intermediate precision: RSD% lower than 4.5% at the highest concentration and lower than 13% at the lowest one were calculated for intra-day repeatability. A groundwater sample suspected of contamination by leaking underground petroleum storage tanks was analysed and some of the analytes were detected and quantitated. 相似文献
2.
Pérez Pavón JL del Nogal Sánchez M Fernández Laespada ME Moreno Cordero B 《Journal of chromatography. A》2007,1175(1):106-111
A sensitive method is presented for the fast analysis of seven fuel oxygenates (methanol, ethanol, tert-butyl alcohol (TBA), methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), tert-amyl methyl ether (TAME) and diisopropyl ether (DIPE)) and benzene, toluene, ethylbenzene and p-xylene (BTEX) in water samples. The applicability of a headspace (HS) autosampler in combination with a GC device equipped with a programmable temperature vaporizer (PTV) and a MS detector is explored. The proposed method achieves a clear improvement in sensitivity with respect to conventional headspace methods due to the use of the PTV. Two different packed liners with materials of different trapping strengths (glass wool and Tenax-TA) were compared. The benefits of using Tenax-TA instead of glass wool as packed material for the measurement of the 11 compounds emerged as better signal-to-noise ratios and hence better detection limits. The proposed method is extremely sensitive. The limits of detection are of the order of ng/L for six of the compounds studied and of the order of microg/L for the rest, with the exception of the most polar and volatile compound: methanol. Precision (measured as the relative standard deviation for a level with an S/N ratio close to 3) was equal to or lower than 15% in all cases. The method was applied to the determination of the analytes in natural matrixes (tap, river and sea water) and the results obtained can be considered highly satisfactory. The methodology has much lower detection limits than the concentration limits proposed in drinking water by the US Environmental Protection Agency (EPA) and the European Union for compounds under regulation. 相似文献
3.
A new protocol for the simultaneous determination of methyl tert-butyl ether (MTBE); its main degradation products: tert-butyl alcohol (TBA) and tert-butyl formate (TBF); other gasoline additives, oxygenate dialkyl ethers: ethyl tert-butyl ether (ETBE), tert-amyl methyl ether (TAME) and diisopropyl ether (DIPE); aromatics: benzene, toluene, ethylbenzene and xylenes (BTEX) and other compounds causing odour events such as dicyclopentadiene (DCPD) and trichloroethylene (TCE) in soils has been developed. On the basis of US Environmental Protection Agency (EPA) method 5035A, a fully automated closed-system purge-and-trap coupled to gas chromatography/mass spectrometry (P&T-GC/MS) was optimised and permitted to detect microg/kg concentrations in solid matrices avoiding losses of volatile compounds during operation processes. Parameters optimised were the sampling procedure, sample preservation and storage, purging temperature, matrix effects and quantification mode. Using 5 g of sample, detection limits were between 0.02 and 1.63 microg/kg and acceptable method precision and accuracy was obtained provided quantification was performed using adequate internal standards. Soil samples should be analysed as soon as possible after collection, stored under -15 degrees C for not longer than 7 days if degradation products have to be analysed. The non-preservative alternative (empty vial) provided good recoveries of the most analytes when freezing the samples up to 7 day holding time, however, if biologically active soil are analysed the preservation with trisodium phosphate dodecahydrate (Na(3)PO(4).12H(2)O or TSP) is strongly recommended more than sodium bisulphate (NaHSO(4)). The method was finally applied to provide threshold and background levels of several gasoline additives in a point source and in sites not influenced by gasoline spills. The proposed method provides the directions for the future application on real samples in current monitoring programs at gasoline pollution risk sites where till now little monitoring data for MTBE in soils are available. 相似文献
4.
A method was developed to analyze methyl tert.-butyl ether (MTBE) and its degradation products by gas chromatography with mass spectrometry (GC-MS) or flame ionization detection (FID) with direct aqueous injection. The column had dimensions of 30 m x 0.25 mm with film thickness 0.25 microm and a stationary phase of FFAP (nitroterephthalic acid-modified polyethylene glycol). The optimized GC conditions for non-acid components were as follows: carrier gas flow-rate,l mL/min; oven temperature, 35 degrees C for 5.5 min, ramped to 90 degrees C at 25 degrees C/min, then ramped to 200 degrees C at 40 degrees C/min and held at 200 degrees C for 8 min. The conditions for the acid components were: carrier gas flow-rate, 1 mL/min; oven temperature, 110 degrees C for 2 min, ramped to 150 degrees C at 10 degrees C/min, then ramped to 200 degrees C at 40 degrees C/min. The injection port contained a silanized-glass reverse-cup liner filled with Carbofrit. The minimum concentrations for the linear range for the selective ion monitoring mode were 30 to 100 microg/L, depending on the analytes. The minimum detection limit was 1 mg/L for MTBE and tert.-butanol when using FID. More components could be analyzed with the FFAP-type column than with the cyanopropylphenyl-dimethyl polysiloxane-type column. 相似文献
5.
《Journal of separation science》2017,40(7):1508-1515
Benzene, toluene, ethylbenzene, and xylenes are some of the most hazardous constituents found in commercial gasoline samples; therefore, these components must be monitored to avoid toxicological problems. We propose a new routine method of ultrafast gas chromatography coupled to flame ionization detection for the direct determination of benzene, toluene, ethylbenzene, and xylenes in commercial gasoline. This method is based on external standard calibration to quantify each compound, including the validation step of the study of linearity, detection and quantification limits, precision, and accuracy. The time of analysis was less than 3.2 min, with quantitative statements regarding the separation and quantification of all compounds in commercial gasoline samples. Ultrafast gas chromatography is a promising alternative method to official analytical techniques. Government laboratories could consider using this method for quality control. 相似文献
6.
Analytical characteristics of the determination of benzene,toluene, ethylbenzene and xylenes in water by headspace solvent microextraction 总被引:3,自引:0,他引:3
Headspace solvent microextraction (HSM) is a novel method of sample preparation for chromatographic analysis. It involves exposing a microdrop of high-boiling point organic solvent extruded from the needle tip of a gas chromatographic syringe to the headspace above a sample. Volatile organic compounds are extracted and concentrated in the microdrop. Next, the microdrop is retracted into the microsyringe and injected directly into the chromatograph. HSM has a number of advantages, including renewable drop (no sample carryover), low cost, simplicity and ease of use, short time of analysis, high sensitivity and low detection limits, good precision, minimal solvent use, and no need for instrument modification. This paper presents analytical characteristics of HSM as applied to the determination of benzene, toluene, ethylbenzene and xylenes in water. 相似文献
7.
Anna Ledin Lotte Ask Reitzel Poul L Bjerg 《International journal of environmental analytical chemistry》2013,93(14):1075-1087
Benzylsuccinic acid (BSA) and methylbenzylsuccinic acids (mBSAs) are unambiguous indicators of anaerobic toluene and ethylbenzene/xylene degradation, and so the determination of these compounds in landfill leachates and contaminated groundwater is highly relevant. Samples were diluted to <0.8?mS?cm?1 in order to reduce their ionic strength, and subsequently extracted through strong anion exchange disks, followed by simultaneous in-vial elution and methylation. A detection limit of 0.1?µg?L?1 was obtained for 100?mL samples. Using this method, 19.3?µg?L?1 of BSA was measured in a landfill leachate, and low µg?L?1 levels of all of the mBSAs were measured in gasoline-contaminated groundwater. The results were compared with the findings of BSAs at 16 other contaminated sites, and BSAs as indicators of biodegradation were evaluated. The estimation of biodegradation rates based on parent hydrocarbons and BSA concentrations or ratios is questionable. However, the degradation products serve as good qualitative in situ indicators for anaerobic biodegradation in contaminated groundwater. 相似文献
8.
Headspace microdrop analysis--an alternative test method for gasoline diluent and benzene,toluene, ethylbenzene and xylenes in used engine oils 总被引:1,自引:0,他引:1
The primary standard test method used for the determination of gasoline diluent in used engine oils is method D 3525-93 of the American Society for Testing and Materials (ASTM), which involves direct injection of used oil onto a packed GC column and flame ionization detection. Recently, we have utilized a new headspace sampling method: headspace solvent microextraction (HSM), for GC and GC-MS analysis of gasoline diluent in used engine oils. High resolution capillary columns can be used without the necessity for the use of inlet cryogenic cooling or expensive sampling interfaces. This analytical method, which we generically refer to as headspace microdrop analysis yields results comparable to those obtained using the ASTM method, with the added benefit that it allows the quantification of individual volatile diluent components, including benzene, toluene, ethylbenzene and the xylenes. 相似文献
9.
Determination of benzene, toluene, ethylbenzene and xylenes in soils by multiple headspace solid-phase microextraction 总被引:4,自引:0,他引:4
Multiple headspace-solid phase microextraction (MHS-SPME) is a recently developed technique for the quantification of analytes in solid samples that avoids the matrix effect. This method implies several consecutive extractions from the same sample. In this way, the total area corresponding to complete extraction can be directly calculated as the sum of the areas of each individual extraction when the extraction is exhaustive, or through a mathematical equation when it is not exhaustive. In this paper, the quantitative determination of benzene, toluene, ethylbenzene and xylene isomers (BTEX) in a certified soil (RTC-CRM304, LGC Promochem) and in a contaminated soil by multiple HS-SPME coupled to a gas chromatography-flame ionisation detector (GC-FID) is presented. BTEX extraction was carried out using soil suspensions in water at 30 degrees C with a 75 microm carboxen-polydimethylsiloxane (CAR-PDMS) fibre and calibration was carried out using aqueous BTEX solutions at 30 degrees C for 30 min with the same fibre. BTEX concentration was calculated by interpolating the total peak area found for the soils in the calibration graphs obtained from aqueous solutions. The toluene, ethylbenzene, o-xylene and m,p-xylene concentrations obtained were statistically equal to the certified values. 相似文献
10.
In this study an atomic absorption spectrophotometer equipped with a selenium hollow-cathode lamp was used for analysis of BTEX (benzene, toluene, ethylbenzene and xylenes) in headspace of aqueous solutions. Initially effective factors on headspace such as volume of solution, stirring time, stirring speed, velocity of carrier gas, temperature, number of strippings, addition of salts and salt concentration were investigated and optimum conditions were selected. By addition of salt in different concentrations, different absorbances were obtained for headspace, therefore, binary mixtures of BTEX were analyzed with simultaneous equations. Obtained results agreed with actual amounts and repeatability was very good (RSD% < 3). Correlation coefficients (r) for calibration curves were about 0.999. This proposed method is comparable with absorbance determination of solution with respect to correlation coefficient, linear dynamic range, limit of detection (LOD) and relative standard deviation (RSD), but this method is less susceptible to interferences and more selective. 相似文献
11.
We have developed a modified method for the extraction and preconcentration of benzene, toluene, ethylbenzene and xylenes (BTEX) in aqueous samples. It based on dispersive liquid-liquid microextraction along with solidification of floating organic microdrops. The dispersion of microvolumes of an extracting solvent into the aqueous occurs without dispersive solvent. Various parameters have been optimized. BTEX were quantified via GC with FID detection. Under optimized conditions, the preconcentration factors range from 301 to 514, extraction efficiencies from 60 to 103 %, repeatabilities from 2.2 to 4.1 %, and intermediate precisions from 3.5 to 7.0 %. The relative recovery for each analyte in water samples at three spiking levels is >85.6 %, with a relative standard deviation of <7.4 %. Figure
A modified method based on dispersive liquid-liquid microextraction to preconcentrate benzene, toluene, ethylbenzene and xylenes was investigated. The method was rapid, precise, efficient, and sensitive. Experimental parameters affecting the extraction process were evaluated. The optimized procedure was validated according to the ICH guidance. 相似文献
12.
Use of in-tube sorptive extraction techniques for determination of benzene, toluene, ethylbenzene and xylenes in soft drinks 总被引:1,自引:0,他引:1
A comparison is made between static headspace analysis and headspace solid-phase dynamic extraction (HS-SPDE) for the quantitative determination of trace level BTEX solvents (benzene, toluene, ethylbenzene and o-, m-, and p-xylene) in soft drinks. Two non-polar extraction phases were investigated for SPDE using an automated sampler with a gas-tight syringe equipped with a special needle coated on the inside with the extraction phase. Following adsorption onto the phase, the analytes were thermally desorbed directly into a GC-MS. The techniques were optimised and evaluated by analysis of spiked soft drink samples. The use of the SPDE device gave comparable results to the static headspace method, with lower detection limits for some compounds, and also offers advantages for applications where lower temperatures are preferred. 相似文献
13.
Tumbiolo S Gal JF Maria PC Zerbinati O 《Analytical and bioanalytical chemistry》2004,380(5-6):824-830
The aim of the study was to analyse BTEX compounds (benzene, toluene, ethylbenzene, xylenes) in air by solid phase micro-extraction/gas chromatography/mass spectrometry (SPME/GC/MS), and this article presents the features of the calibration method proposed. Examples of real-world air analysis are given. Standard gaseous mixtures of BTEX in air were generated by dynamic dilution. SPME sampling was carried out under non-equilibrium conditions using a Carboxen/PDMS fibre exposed for 30 min to standard gas mixtures or to ambient air. The behaviour of the analytical response was studied from 0 to 65 g/m3 by adding increasing amounts of BTEX to the air matrix. Detection limits range from 0.05 to 0.1 g/m3 for benzene, depending on the fibre. Inter-fibre relative standard deviations (reproducibility) are larger than 18%, although the repeatability for an individual fibre is better than 10%. Therefore, each fibre should be considered to be a particular sampling device, and characterised individually depending on the required accuracy. Sampling indoor and outdoor air by SPME appears to be a suitable short-delay diagnostic method for volatile organic compounds, taking advantage of short sampling time and simplicity. 相似文献
14.
《Journal of separation science》2003,26(14):1225-1229
A method for determination of benzene, toluene, ethylbenzene, and xylenes (BTEX) in urine is described. Determination is performed by dynamic headspace (purge and trap) gas chromatography with photoionization detection. The features of the described method, i.e. detection limits of 15–35 ng L–1, relative standard deviations of 0.2–10%, accuracy of 80–100%, removal of interference of many compounds present in urine, sharp chromatographic peaks because of cryogenic refocusing, no sample preparation, make it convenient for biological monitoring of exposure to low levels of BTEX. However, the method is time‐consuming and sophisticated. 相似文献
15.
Development of a versatile,easy and rapid atmospheric monitor for benzene,toluene, ethylbenzene and xylenes determination in air 总被引:1,自引:0,他引:1
Francesc A. Esteve-Turrillas Saray Ly-VerdúAgustín Pastor Miguel de la Guardia 《Journal of chromatography. A》2009,1216(48):8549-8556
A new procedure for the passive sampling in air of benzene, toluene, ethylbenzene and xylene isomers (BTEX) is proposed. A low-density polyethylene layflat tube filled with a mixture of solid phases provided a high versatility tool for the sampling of volatile compounds from air. Several solid phases were assayed in order to increase the BTEX absorption in the sampler and a mixture of florisil and activated carbon provided the best results. Direct head-space-gas chromatography–mass spectrometry (HS-GC–MS) measurement of the whole deployed sampler was employed for a fast determination of BTEX. Absorption isotherms were used to develop simple mathematical models for the estimation of BTEX time-weighted average concentrations in air. The proposed samplers were used to determine BTEX in indoor air environments and results were compared with those found using two reference methodologies: triolein-containing semipermeable membrane devices (SPMDs) and diffusive Radiello samplers. In short, the developed sampling system and analytical strategy provides a versatile, easy and rapid atmospheric monitor (VERAM). 相似文献
16.
José Luis Pérez Pavón Sara Herrero MartínCarmelo García Pinto Bernardo Moreno Cordero 《Journal of chromatography. A》2009,1216(32):6063-6070
A methodology based on the coupling of a headspace autosampler with a GC and a MS detector operating in SIM mode has been developed for the determination of volatile organic compounds (THMs and BTEX) in soils. The GC device used is equipped with a programmable temperature vaporizer (PTV) packed with Tenax-TA® to introduce the samples (the injection mode used was solvent vent), and a modular accelerated column heater (MACH™) to control column temperature. The proposed measurement procedure reduces the sample pretreatment step to a minimum. Combined use of solvent vent injection mode and mass spectrometry detection allows a highly sensitive method to be proposed, with limits of detection of the order of ng/kg for all the target compounds. Furthermore, the capillary column used allows rapid separations of compounds in less than 4.60 min, affording a very short total analysis cycle time of 9 min. 相似文献
17.
Nardi L 《Journal of chromatography. A》2003,985(1-2):85-91
The suitability of "capillary extractors" is demonstrated for the "negligible depletion" extraction of benzene, toluene, ethylbenzene and xylenes in a clean-water matrix. Extraction set-up and major extractor parameters (length, internal diameter, and film thickness) are chosen to allow rugged analysis by GC with flame ionization detection. With the selected negligible extraction conditions, the efficiency for every consecutive extraction is about 2-3% of the dissolved amount. 相似文献
18.
Jiemin Liu Guibin Jiang Qunfang Zhou Jingfu Liu Meijuan Wen 《Analytical sciences》2003,19(10):1407-1411
A laboratory-made micro-cryogenic chromatographic oven was mainly improved in size, which was controlled at 6 x 6 x 2.5 cm. A thermoelectric system was used to cool the capillary column instead of the traditional liquid cryogen. A cold block connected to the cryogenic module was directly solidified at room temperature with thermally conductive adhesive so that the uniformity of transferring heat was greatly improved, and the size of the system was reduced. Moreover, this system was inexpensive and convenient for both operation and control. The newly developed device coupled with headspace solid-phase microextraction (SPME) was successfully applied to the determination of methyl tert-butyl ether (MTBE) and its degradation products. During the analysis procedure, a 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used to extract MTBE and its degradation products. The extraction was controlled at 50 degrees C for 30 min and the NaCl content in the sample was maintained at 35%. The limits of detection (LODs) ranged from 0.006 microg mL(-1) (for MTBE) to 0.206 microg mL(-1) (for methyl acetate) and the relative standard deviations (RSD%) were below 4%. The spiked recoveries for the developed method were evaluated using various water samples as a matrix. 相似文献
19.
Koffi Badjagbo Pierre Picard Serge Moore Sébastien Sauvé 《Journal of the American Society for Mass Spectrometry》2009,20(5):829-836
Real-time monitoring of benzene, toluene, ethylbenzene, and xylenes (BTEX) in ambient air is essential for the early warning
detection associated with the release of these hazardous chemicals and in estimating the potential exposure risks to humans
and the environment. We have developed a tandem mass spectrometry (MS/MS) method for continuous real-time determination of
ambient trace levels of BTEX. The technique is based on the sampling of air via an atmospheric pressure inlet directly into
the atmospheric pressure chemical ionization (APCI) source. The method is linear over four orders of magnitude, with correlation
coefficients greater than 0.996. Low limits of detection in the range 1–2 μg/m3 are achieved for BTEX. The reliability of the method was confirmed through the evaluation of quality parameters such as repeatability
and reproducibility (relative standard deviation below 8% and 10%, respectively) and accuracy (over 95%). The applicability
of this method to real-world samples was evaluated through measurements of BTEX levels in real ambient air samples and results
were compared with a reference GC-FID method. This direct APCI-MS/MS method is suitable for real-time analysis of BTEX in
ambient air during regulation surveys as well as for the monitoring of industrial processes or emergency situations. 相似文献
20.
Simultaneous determination of benzene,toluene, ethylbenzene,and xylene metabolites in human urine using electromembrane extraction combined with liquid chromatography and tandem mass spectrometry 下载免费PDF全文
Joon Hyuk Suh Hye Yeon Lee Unyong Kim Han Young Eom Junghyun Kim Hyun‐Deok Cho Sang Beom Han 《Journal of separation science》2015,38(24):4276-4285
For the first time, electromembrane extraction combined with liquid chromatography and tandem mass spectrometry was applied for the determination of urinary benzene, toluene, ethylbenzene, and xylene metabolites. S‐Phenylmercapturic acid, hippuric acid, phenylglyoxylic acid, and methylhippuric acid isomers were extracted from human urine through a supported liquid membrane consisting of 1‐octanol into an alkaline acceptor solution filling the inside of a hollow fiber by application of an electric field. Various extraction factors were investigated and optimized using response surface methodology, the statistical method. The optimum conditions were established to be 300 V applied voltage, 15 min extraction time, 1500 rpm stirring speed, and 5 mM ammonium acetate (pH 10.2) acceptor solution. The method was validated with respect to selectivity, linearity, accuracy, precision, limit of detection, limit of quantification, recovery, and reproducibility. The results showed good linearity (r2 > 0.995), precision, and accuracy. The extract recoveries were 52.8–79.0%. Finally, we applied this method to real samples and successfully measured benzene, toluene, ethylbenzene, and xylene metabolites. 相似文献